Gas-Insulated Switchgear with Vacuum Circuit-Breaker 1, 2 or 3-phase
System configuration
Conditions of Delivery
The General Conditions of Delivery as amended shall apply.
Illustrations
The illustrations are not binding
WI Contents
Overview............................................................................................................... 4
Features.......................................................................................................... 4
Product description............................................................................................. 5
Technical description....................................................................................... 5
Components of the switching unit................................................................... 6
Modular design................................................................................................ 7
Single busbar WIA up to 36 kV...................................................................... 7
Double busbar WIB up to 36 kV.................................................................... 7
Single busbar WIA 52 kV, 250 kV BIL........................................................... 8
Double busbar WIB 52 kV, 250 kV BILL........................................................ 8
Operator interfaces......................................................................................... 9
Switchgear panels......................................................................................... 10
Current/voltage transformers........................................................................ 11
Busbar modules............................................................................................ 13
Modules......................................................................................................... 15
Interlocks....................................................................................................... 16
Gas compartment monitoring WIA, WIB....................................................... 17
Gas-filled compartments of the WIA/ WIB.................................................... 18
Selection tables................................................................................................. 22
WIA/WIB 12 kV............................................................................................. 22
WIA/WIB 17 kV............................................................................................. 24
WIA/WIB 24 kV............................................................................................. 26
WIA/WIB 36 kV............................................................................................. 28
WIA/WIB 38 kV............................................................................................. 30
WIA/WIB 40.5 up to 52 kV............................................................................ 32
WIA/WIB 1 and 2-pole, for stationary railway traction power supply 50/60 hz......34
Range of products............................................................................................. 36
Single busbar panels WIA............................................................................. 36
Double busar panels WIB............................................................................. 37
Disconnector panel....................................................................................... 38
Bus section coupler / riser panel................................................................... 38
Bus section coupler, Bus coupler, metering panel........................................ 39
Cable connections............................................................................................. 40
Ecological considerations................................................................................ 43
Design data........................................................................................................ 44
Space requirements - dimensions and weights............................................ 44
Busbar connection with fully insulated conductor bars................................. 48
Shipping instructions........................................................................................ 50
Delievery, packaging..................................................................................... 50
WI EN 3
WI Overview
Features
The gas-insulated and metal-enclosed switchgear WI has been designed
for operation in power plants, transformer substations and industrial
networks.
The WI switchgear with vacuum circuit-breaker features maximum
availability, optimum operator safety and clear design using SF6 gas as
insulating medium. The switchgear units are insensitive to environmental
influences, such as humidity, dust and aggressive gases, and offer
complete operator safety. Their clear design facilitates operation.
Essential features
Parts under medium voltage in SF6 atmosphere
insensitive to air humidity, air pollution and foreign matter
High degree of operator safety
complete metal enclosure for all system components under medium
voltage
Compact and clear design
No mechanically moved parts in the busbar section
No problems with SF6 decomposition products
currents are switched in the vacuum interrupter chamber
Single busbar WIA up to 36 kV
Inert insulating gas SF6 protects the switchgear against fire
Three-pole enclosure of the functional compartments
negligible sheath currents
small number of static and dynamic seals
few gas compartments, pressure relief devices and gas monitoring
devices
easy access
moderate pressure increase in case of internal arcs
straightforward kinematics between drive and circuit-breaker or
three-position switch
Steel used as enclosure material
high pressure proofness
good screening effect against X rays
Optimum security of operation
complete interlocking system
separate actuators for isolation and earthing
automatic circuit-breaker ON or OFF operation in case of earthing at
the outgoing feeder
High capacity current and voltage transformer
Delivery of prefabricated switchgear panels to the construction site
Fully shrouded terminals
pluggable, fully insulated cable end boxes
Switchgear extension possible
on both sides
from single to double busbar system.
4 WI EN
WI Product description
Technical description
WI panels are suitable for configuring single or double busbar switchgear in
conjunction with indoor installation.
WI switchgear units are completely metal-enclosed. The busbar
compartment which accommodates fixed parts only is segregated gas-tight
from the flange-mounted switching unit. The switching unit comprises the
three-position switch with isolating and earthing functions and the vacuum
circuitbreaker; in case of double busbar systems, there are two three-
position switches with isolating and earthing functions and the vacuum
circuit-breaker.
The busbar compartment and the switching unit feature three-pole
enclosure. Single-pole enclosure is provided in the area of the toroidalcore
current transformers which are located in an easily accessible position
outside of the SF6 atmosphere. The compact design results in a very clear
Gas-insulated double busbar switchgear WIB switchgear arrangement with low space requirement; it has the advantage
Rated voltage up to 36 kV; rated peak withstand that a switching unit can be mounted or removed very quickly without the
current up to 100 kA; rated current up to 2500 A busbar requiring isolation from the power supply.
The panels are equipped with a low-voltage cabinet for the required
measuring and protection relays or the terminal strips. The high
performance of the instrument transformers installed means that not only
electronic but also conventional protection relays can be deployed.
Thanks to its design, this panel series permits straightforward extension of
an existing switchgear on both sides, and extension from single to double
busbar models.
WI EN 5
WI Product description (contd.)
Earthing
The metal-enclosed WI series switchgear is equipped with a separate
earthing line running along the length of the switchgear.
Wiring
Wiring is effected with flexible cables (HO7V-K) in the technically required
cross-sections.
Corrosion protection
If desired, the indoor panels WIA and WIB can be provided optionally with
enhanced corrosion protection. To ensure optimum switchgear protection,
the environmental installation conditions, such as wind-borne sand,
aggressive dust (to be defined as salt dust, coke dust, cement dust etc.),
vermin (termites), increased humidity levels, aggressive atmosphere (type
of chemicals and their concentration to be defined) must be specified.
Installation locations
The switchgear has been designed for installation in closed electrical
operating facilities.
6 WI EN
WI Product description (contd.)
Modular design
A
C2
C1 Tank with busbar 1
C2 Tank with busbar 2
D Supporting structure with cable connection area
E Low voltage cabinet
B
C1
WI EN 7
WI Product description (contd.)
A
Single busbar WIA 52 kV, 250 kV BIL
A Tank with vacuum circuit-breaker and disconnector / earthing switch
C B Drive with control panel and pressure gauge for gas monitoring
C Tank with busbar
B D Supporting structure with cable connection area
E Low voltage cabinet
8 WI EN
WI Product description (contd.)
16
17 15
WI EN 9
WI Product description (contd.)
Switchgear panels
Single busbar Double busbar
Switchgear panel WIA up to 36 kV Switchgear panel WIB up to 36 kV
10
9
10
8
7 7
1
1
6 2
6
2
5
5
4
3 3
4
10
6
7
2
6
1
2
5
4
3 4
Current/voltage transformers
Current transformers
The current transformers are designed as toroidal-core transformers and
are put onto the cable outgoing feeder areas with single-pole enclosure.
The current transformers in line with the busbar consist of identical units.
There, they are slipped onto the busbar areas which also feature singlepole
enclosure. The capacity of the current transformers is designed in such a
way that supply of conventional protective devices is also possible.
Up to 3 transformers (3 cores) can be accommodated per phase and
outgoing feeder. The transformers can also be exchanged subsequently.
Three current transformers (3 cores) per phase can also be installed in line
with the busbar, in order to measure its currents.
A special current transformer arrangement is the bus coupler panel within
one panel width. In the double busbar top attachment tank, one core of
Current transformer in line max. 80 mm height with an ID of 135 mm and an OD of 195 mm can be
with the busbar installed for each phase. The low voltage is led out via a max. 7-pole line
which is SF6 proof.
Dimensions
Outgoing feeder:
Transformer ID 185 mm
Transformer OD 275 mm
Max. stacking height 160 mm
Measurement Protection
/dyn (kA) 100
Ith (3sec) (kA) 40
Class 0.5 M 5 10 P 40 10 P 10
Core rating (VA) (VA) up to 15 up to 5 up to 30
Primary rated current (A) 150 up to 2500
Secondary rated current (A) 1 or 5
WI EN 11
WI Product description (contd.)
Voltage transformer
The conventional solution for the inductive voltage transformer is a
separate single-phase metalenclosed module which can be connected via
cable connectors almost anywhere in the busbar area and on the outgoing
feeder cable, and thus arranged in practically any location as required.
in the outgoing feeder area
Another design comprises metal-enclosed inductive voltage transformers
directly flangemounted to the outgoing feeder block, with the isolating /
earthing device mounted upstream. An externally operated isolating
feature prevents the voltage transformer from being endangered/ put at
risk during DC tests on the cable.
on the busbar
A separate metering panel with a set of inductive voltage transformers is
provided to this effect. Taking account of the high priority of the busbar, a
disconnector enables isolation of the transformer section. Both
disconnector and transformer are located in separate compartments.
Thus, any damage which might occur in the vicinity of the transformer
does not affect the isolating area or the busbar.
Performance characteristic
Ratings: up to 50 VA
Class: 0.5
1 Multi-tank
2 Test cable connector
12 WI EN
WI Product description (contd.)
Busbar modules
Gas tank incl. installation parts
Busbar
Cover attachment on mounting flange with or without pressure relief.
All five busbar compartments require one pressure relief device. If it is not
possible to mount the device to the ends of the busbar tanks, e.g. if a tank
for voltage transformer connection or a busbar earthing switch is located
on the busbar end, or if the switchgear consists of over 10 panels, every
fifth panel is equipped with a pressure relief device on the mounting flange
Cover attachment on the stop flange of the left-hand and right-hand end
panel, with or without pressure relief, to connect metalenclosed voltage
transformers with cable connection to the front.
Gas lines incl. pressure gauges; preferably attached to the end panel.
(Only once for each gas compartment.)
Desiccant for 4 busbar tanks each, or for each gas compartment. (Cannot
be mounted on switchgear panels equipped with pressure relief device.)
Compensation element for busbar tanks. Required after 20 single busbar
panels, and after 10 double busbar panels.
Disconnector for bus sectionalizer
Earthing switch for bus sectionalizer to the left and right of the
disconnector
WI EN 13
WI Product description (contd.)
14 WI EN
WI Product description (contd.)
Modules
The modules and attachments shown on this page apply to
outgoing feeder panels
incoming feeder panels
panels with circuit-breaker in case of coupler panels and bus
sectionalizers.
Switching device module
Gas tank incl. pressure relief device, gas lines and pressure gauge
Switching devices with three-position switch and vacuum circuit-breaker,
desiccant
Drive section module
Drive casing with drive mechanisms incl. interlocks
Attachment of drive casing on switching device module incl. connecting
parts
Attachments for the vacuum circuit-breaker
Motor drive mechanism to charge the energy-storing device
Auxiliary switch, 8, 12 or 16 contacts; 8 contact elements are required for
the basic circuitry (material: silver [normal], gold, silver-palladium)
Passing contact for pulse contact time stretching (contacts normal or
gold-plated)
Push switch actuated by energystoring device. (Push switches for basic
circuitry included in basic design)
Push switch, actuated by ON-OFF pushbutton. (The basic design
includes 1 push switch for each)
Shunt closing release, 1 ea.
Shunt opening release, 1 or 2 ea. with or without auxiliary spring energy
store
Secondary release, 1 or 2 ea., or in case of design without undervoltage
release: 3 ea.
Undervoltage release, with or without time delay
Blocking coil on ON pushbutton. Always required on coupler switch in
case of bus section coupler and bus coupler, consisting of 2 panels
(switchgear panel + bus riser panel)
Blocking coil on OFF pushbutton. Always required on coupler switch in
case of bus section coupler and bus coupler, consisting of 1 or 2 panel(s)
(switchgear panel + bus riser panel)
Mechanical lock-out with lock (for vacuum circuit-breaker and three-
position switch)
Counter
Attachments for three-position switch
Motor-drive mechanism. In case of single busbar: 1 motor-drive
mechanism each for isolating and earthing movements. In case of double
busbar: 1 motor-drive mechanism for the isolating movement of busbar 1,
busbar 2 and earthing movement of busbars 1+2. The vacuum
circuitbreaker s ON button features a mechanical lock-out.
An auxiliary switch, 2-20 contact elements each, for disconnecting and
earthing movement. (Material: silver (normal), gold, silverpalladium)
Interlocking solenoid. Single busbar: only in circuit-breaker panel of
coupler and in bus riser panel of bus sectionalizer. Generally required in
case of double busbar. If the interlocking solenoids are not installed in
case of remote control (motor-drive mechanism) of the three-position
switch, the local actuation is not locked. In this case, mechanical lock-
outs (locks) are required on the ON button of the vacuum ircuit-breaker
and on the threeposition switch.
always required
optional
WI EN 15
WI Product description (contd.)
Interlocks
Actuation of the three-position switch and the continuous mechanical
interlock between circuitbreaker and three-position switch are designed in
such a way that the operator can proceed as usual. This means separate,
completely interlocked actuation for the switching procedures Establishing
isolating distance and Earthing. For the earthing procedure, which is only
possible with the three-position switch in isolated position, the circuit-breaker
switched off and the circuit-breaker energy-storing device pre-charged, the
circuitbreaker is connected positively after the contact blades have
beeninserted into the earthing contacts, and protected against immediate
mechanical or electrical switching OFF. Vice versa, on de-earthing, the
circuit-breaker is first switched off positively before the isolating distance to
the earthing contacts established. The interlocks ensure that each
switching operation is always performed completely. Thus, once the
switching operation has commenced, the motion cannot be reversed, if
applicable, and the operating lever cannot be removed before it reaches its
end position.
The description only refers to the single busbar. In the case of double
busbars, some of the internal interlocking functions of the panel, as well as
all inter-panel interlocking functions are performed by electro-mechanical
interlocks (blocking coil).
The following interlocking functions are provided:
Disconnector does not switch ON while the circuit-breaker or the earthing
switch are ON
None of the disconnectors switches OFF while the circuit-breaker or the
earthing switch are ON
Circuit-breaker only switches ON with the disconnector in its end position
No earthing with disconnector engaged
No earthing with circuit-breaker ON
No earthing without circuit-breaker being in ready-to-operate condition
Automatic connection of circuitbreaker during earthing
Automatic disconnection of circuit- breaker during de-earthing
The following has been ensured:
The operating crank cannot be removed from the disconnector or
earthing switch before it has reached its end positions completely
The circuit-breaker cannot be actuated while a switching operation is
being performed on the disconnector or earthing switch
The circuit-breaker cannot be switched off with the three-position switch
in earthing position
All interlocks act partly mechanically and partly electrically
An operating crank can only be inserted on the disconnector or earthing
switch once the insertion opening has been released via a manual
interrogation system.
All interlocks also effective when the three-position switch is
motor-actuated.
16 WI EN
WI Product description (contd.)
Gas-tight electrical
bushing
1 Gas-filled busbar compartments
2 Gas-filled circuit-br eaker compartments Check valve
Gas connector socket (disposal valve)
Pressure gauge
Gas-tight electrical
bushing
1 Gas-filled busbar2 compartments
2 Gas-filled busbar1 compartments Double check valve
3 Gas-filled circuit-br eaker compartments Gas connector socket (disposal valve)
Pressure gauge
WI EN 17
WI Product description (contd.)
busbar 1 compartment
busbar 2 compartment
18 WI EN
WI Standards
Regulations, provisions and standards
105 - T
At 25 0 C T < 40 0C INT = IN
65
105 - T
At 40 0 C < T 55 0C INT = IN 0.7
65
Ambient conditions
Temperature class "Minus 25 indoors 1)
Min./max. ambient temperature C -51) / 40 2)
Average value over 24 hours (max.) C 35 3)
Maximum installation altitude above sea m 1000 4)
level
Insulating gas
Type Sulphur hexafluoride (SF6)
Design pressure pre at 20 C MPa 0.03 - 0.05
1)
Optional: minus 25 indoors
2)
Optional up to 55 C in case of reduction of normal currents
3)
Optional up to 40 C in case of reduction of normal currents
4)
Higher installation altitudes possible on request
WI EN 19
WI Standards
Regulations, provisions and standards
(contd.)
Type designation
The type designation of the type-tested, prefabricated panels contains information about their design, rated voltage, insulation
level, panel width and panel height.
Example:
Prefabricated, type-tested WI
series panel with single busbar, for indoor installation, version A
Rated peak withstand current 100 kA
Rated voltage 12 kV; insulation level acc. to list 2
Panel width: 600 mm, panel height: 2100 mm
Type designation: WI A 10 / 12-2 / 621
Type designation Explanation
Series WI . . . /..- . Fully insulated (SF6) switchgear panels, primarily for distribution
substations, for very stringent requirements
Version A Single busbar, indoors
B Double busbar, indoors
20 WI EN
WI Standards
Regulations, provisions and standards
(contd.)
Applied norms
WI switchgear units meet the following standards and regulations:
WI EN 21
WI Selection tables
WIA/WIB 12 kV
Rated insulation level
withstand voltage
Rated frequency
Design pressure
making current
Pr at 20 0C 5)
Rated voltage
Panel width
component
current
1s 3s
mm kV kV kV kV/kV bar Hz A kA kA kA kA %
WIA 8/12-2/621 0.8 630 80 31.5 20 31.5
WIA 8/12-2/621 0.8 1250 80 31.5 31.5 31.5
WIA 8/12-2/621 600 12 75 28 85/32 0.8 50/60 1600 80 31.5 31.5 31.5 38
WIA 8/12-2/621 1.3 2000 80 31.5 31.5 31.5
WIA 8/12-2/621 1.3 25001) 80 31.5 31.5 31.5
WIB 8/12-2/627 0.8 630 80 31.5 20 31.5
WIB 8/12-2/627 0.8 1250 80 31.5 31.5 31.5
WIB 8/12-2/627 600 12 75 28 85/32 0.8 50/60 1600 80 31.5 31.5 31.5 38
WIB 8/12-2/627 1.3 2000 80 31.5 31.5 31.5
WIB 8/12-2/627 1.3 25002) 80 31.5 31.5 31.5
WIA 10/12-2/621 0.8 1250 100 40 40 40
WIA 10/12-2/621 0.8 1600 100 40 40 40
600 12 75 28 85/32 50/60 38
WIA 10/12-2/621 1.3 2000 100 40 40 40
WIA 10/12-2/621 1.3 25001) 100 40 40 40
WIB 10/12-2/627 0.8 1250 100 40 40 40
WIB 10/12-2/627 0.8 1600 100 40 40 40
600 12 75 28 85/32 50/60 38
WIB 10/12-2/627 1.3 2000 100 40 40 40
WIB 10/12-2/627 1.3 25002) 100 40 40 40
LS = Circuit-breaker
TS = Three-position switch, disconnector I/O
ES = Three-position switch, earthing switch I/O
1)
with cooling gas tank, panel height 2750 mm
2)
with motor-actuated fan
3)
possible limits and components fitted, refer to project planning documents WI no. 49 542
4)
adm. tolerance range, no manufacturing tolerance, current value of one specimen, see routine test report
5)
minimum service pressure 0.3 bar at a filling pressure of 0.8 bar; 0.7 bar at a filling pressure of 1.3 bar
22 WI EN
WI Selection tables (contd.)
O - 0.3 s - CO - 3 min - CO
mechanism, 160 W
Arc duration (max.)
4)
4)
breaking current
4)
CO - 15 s - CO
Opening time
Opening time
Closing time
mechanism
LS,
TS,
Off
Off
On
E
On Off
A A kA ms ms ms ms ms ms ms s s
8 10000
8 1000
25 10 1000 10000 100 45-65 33-50 40-70 12 50 20 20 12 18
8 10000
8 1000
25 10 1000 10000 100 45-65 33-50 40-70 12 50 20 20 12 18
10 10000
10 1000
25 10 10000 100 45-65 33-50 40-70 12 50 20 20 12 18
10 1000
10
10 10000
10 1000
25 10 10000 100 45-65 33-50 40-70 12 50 20 20 12 18
10 1000
10
WI EN 23
WI Selection tables (contd.)
WIA/WIB 17 kV
Rated insulation level
withstand voltage
Rated frequency
Design pressure
making current
Rated voltage
Pr at 20 0 C 5)
Panel width
component
current
1s 3s
mm kV kV kV kV/kV bar Hz A kA kA kA kA %
WIA 8/17-2/621 0.8 630 80 31.5 20 31.5
WIA 8/17-2/621 0.8 1250 80 31.5 31.5 31.5
WIA 8/17-2/621 600 17.5 95 38 110/45 0.8 50/60 1600 80 31.5 31.5 31.5 38
WIA 8/17-2/621 1.3 2000 80 31.5 31.5 31.5
WIA 8/17-2/621 1.3 25001) 80 31.5 31.5 31.5
WIB 8/17-2/627 0.8 630 80 31.5 20 31.5
WIB 8/17-2/627 0.8 1250 80 31.5 31.5 31.5
WIB 8/17-2/627 600 17.5 95 38 110/45 0.8 50/60 1600 80 31.5 31.5 31.5 38
WIB 8/17-2/627 1.3 2000 80 31.5 31.5 31.5
WIB 8/17-2/627 1.3 25002) 80 31.5 31.5 31.5
WIA 10/17-2/621 0.8 1250 100 40 40 40
WIA 10/17-2/621 0.8 1600 100 40 40 40
600 17.5 95 38 110/45 50/60 38
WIA 10/17-2/621 1.3 2000 100 40 40 40
WIA 10/17-2/621 1.3 25001) 100 40 40 40
WIB 10/17-2/627 0.8 1250 100 40 40 40
WIB 10/17-2/627 0.8 1600 100 40 40 40
600 17.5 95 38 110/45 50/60 38
WIB 10/17-2/627 1.3 2000 100 40 40 40
WIB 10/17-2/627 1.3 25002) 100 40 40 40
LS = Circuit-breaker
TS = Three-position switch, disconnector I/O
ES = Three-position switch, earthing switch I/O
1)
with cooling gas tank, panel height 2750 mm
2)
with motor-actuated fan
3)
possible limits and components fitted, refer to project planning documents WI no. 49 542
4)
adm. tolerance range, no manufacturing tolerance, current value of one specimen, see routine test report
5)
minimum service pressure 0.3 bar at a filling pressure of 0.8 bar; 0.7 bar at a filling pressure of 1.3 bar
24 WI EN
WI Selection tables (contd.)
O - 0.3 s - CO - 3 min - CO
4)
4)
CO - 15 s - CO
4)
Opening time
Opening time
Closing time
mechanism
LS,
TS,
On
Off
Off
E
On Off
A A kA ms ms ms ms ms ms ms s s
8 10000
8 1000
25 10 8 1000 10000 100 45-65 33-50 40-70 14 50 20 20 12 18
8
8
8 10000
8 1000
25 10 8 1000 10000 100 45-65 33-50 40-70 14 50 20 20 12 18
8
8
10 10000
10 1000
25 10 10000 100 45-65 33-50 40-70 14 50 20 20 12 18
10 1000
10
10 10000
10 1000
25 10 10000 100 45-65 33-50 40-70 14 50 20 20 12 18
10 1000
10
WI EN 25
WI Selection tables (contd.)
WIA/WIB 24 kV
Rated insulation level
withstand voltage
Rated frequency
Design pressure
making current
Rated voltage
Pr at 20 0C 5)
Panel width
component
current
1s 3s
mm kV kV kV kV/kV bar Hz A kA kA kA kA %
WIA 8/24-2/621 0.8 630 80 31.5 20 31.5
WIA 8/24-2/621 0.8 1250 80 31.5 31.5 31.5
WIA 8/24-2/621 600 24 125 50 145/60 0.8 50/60 1600 80 31.5 31.5 31.5 38
WIA 8/24-2/621 1.3 2000 80 31.5 31.5 31.5
WIA 8/24-2/621 1.3 25001) 80 31.5 31.5 31.5
WIB 8/24-2/627 0.8 630 80 31.5 20 31.5
WIB 8/24-2/627 0.8 1250 80 31.5 31.5 31.5
WIB 8/24-2/627 600 24 125 50 145/60 0.8 50/60 1600 80 31.5 31.5 31.5 38
WIB 8/24-2/627 1.3 2000 80 31.5 31.5 31.5
WIB 8/24-2/627 1.3 25002) 80 31.5 31.5 31.5
WIA 10/24-2/621 0.8 1250 100 40 40 40
WIA 10/24-2/621 0.8 1600 100 40 40 40
600 24 125 50 145/60 50/60 38
WIA 10/24-2/621 1.3 2000 100 40 40 40
WIA 10/24-2/621 1.3 25001) 100 40 40 40
WIB 10/24-2/627 0.8 1250 100 40 40 40
WIB 10/24-2/627 0.8 1600 100 40 40 40
600 24 125 50 145/60 50/60 38
WIB 10/24-2/627 1.3 2000 100 40 40 40
WIB 10/24-2/627 1.3 25002) 100 40 40 40
LS = Circuit-breaker
TS = Three-position switch, disconnector I/O
ES = Three-position switch, earthing switch I/O
1)
with cooling gas tank, panel height 2750 mm
2)
with motor-actuated fan
3)
possible limits and components fitted, refer to project planning documents WI no. 49 542
4)
adm. tolerance range, no manufacturing tolerance, current value of one specimen, see routine test report
5)
minimum service pressure 0.3 bar at a filling pressure of 0.8 bar; 0.7 bar at a filling pressure of 1.3 bar
26 WI EN
WI Selection tables (contd.)
O - 0.3 s - CO - 3 min - CO
4)
4)
CO - 15 s - CO
4)
Opening time
Opening time
Closing time
mechanism
LS,
TS,
On
Off
Off
E
On Off
A A kA ms ms ms ms ms ms ms s s
8 10000
8 1000
31.5 10 8 1000 10000 100 45-65 33-50 40-70 14 50 20 20 12 18
8
8
8 10000
8 1000
31.5 10 8 1000 10000 100 45-65 33-50 40-70 14 50 20 20 12 18
8
8
10000
1000
31.5 10 10000 100 45-65 33-50 40-70 14 50 20 20 12 18
1000
-
10000
1000
31.5 10 10000 100 45-65 33-50 40-70 14 50 20 20 12 18
1000
WI EN 27
WI Selection tables (contd.)
WIA/WIB 36 kV
Rated insulation level
withstand voltage
Design pressure
Rated frequency
making current
Rated voltage
Pr at 20 0C 5)
Panel width
component
current
1s 3s
mm kV kV kV kV/kV bar Hz A kA kA kA kA %
WIA 6/36-2/621 1.3 630 63 25 20 25 42
WIA 6/36-2/621 1.3 1250 63 25 25 25 42
WIA 6/36-2/621 600 36 170 70 195/80 1.3 50 1600 63 25 25 25 42
WIA 6/36-2/621 1.3 2000 63 25 25 25 42
1)
WIA 6/36-2/621 1.3 2500 63 25 25 25 42
WIB 6/36-2/627 1.3 630 63 25 20 25 42
WIB 6/36-2/627 1.3 1250 63 25 25 25 42
WIB 6/36-2/627 600 36 170 70 195/80 1.3 50 1600 63 25 25 25 42
WIB 6/36-2/627 1.3 2000 63 25 25 25 42
WIB 6/36-2/627 1.3 25002) 63 25 25 25 42
WIA 10/36-2/621 1.3 1250 100 40 40 40 31
WIA 10/36-2/621 1.3 1600 100 40 40 40 31
600 36 170 70 195/80 50/60
WIA 10/36-2/621 1.3 2000 100 40 40 40 31
1.3 1)
WIA 10/36-2/621 2500 100 40 40 40 31
WIB 10/36-2/627 1.3 1250 100 40 40 40 31
WIB 10/36-2/627 1.3 1600 100 40 40 40 31
600 36 170 70 195/80 50/60
WIB 10/36-2/627 1.3 2000 100 40 40 40 31
WIB 10/36-2/627 1.3 25002) 100 40 40 40 31
LS = Circuit-breaker
TS = Three-position switch, disconnector I/O
ES = Three-position switch, earthing switch I/O
1)
with cooling gas tank, panel height 2750 mm
2)
with motor-actuated fan
3)
possible limits and components fitted, refer to project planning documents WI no. 49 542
4)
adm. tolerance range, no manufacturing tolerance, current value of one specimen, see routine test report
5)
minimum service pressure 0.7 bar
28 WI EN
WI Selection tables (contd.)
O - 0.3 s - CO - 3 min - CO
4)
4)
CO - 15 s - CO
4)
Opening time
Opening time
Closing time
mechanism
LS,
TS,
On
Off
Off
E
On Off
A A kA ms ms ms ms ms ms ms s s
6.3 10000
6.3 1000
50 10 6.3 1000 10000 100 43-65 29-50 40-65 14 50 20 20 12 18
6.3
6.3
6.3 10000
6.3 1000
50 10 6.3 1000 10000 100 43-65 29-50 40-65 14 50 20 20 12 18
6.3
6.3
6.3 10000
6.3 1000
50 10 10000 100 43-65 40-65 14 50 20 12 18
6.3 1000
6.3
6.3 10000
6.3 1000
50 10 10000 100 43-65 40-65 14 50 20 12 18
6.3 1000
6.3
WI EN 29
WI Selection tables (contd.)
WIA/WIB 38 kV
Rated insulation level
3)
withstand voltage
Rated frequency
Design pressure
making current
Rated voltage
Pr at 20 0C 5)
Panel width
component
current
1s 3s
mm kV kV kV kV/kV bar Hz A kA kA kA kA %
WIA 8/38-2/621 1.45 630 80 31.5 20 31.5 31
WIA 8/38-2/621 1.45 1250 80 31.5 31.5 31.5 31
WIA 8/38-2/621 600 38 200 80 220/90 1.45 50/60 1600 80 31.5 31.5 31.5 31
WIA 8/38-2/621 1.45 2000 80 31.5 31.5 31.5 31
1)
WIA 8/38-2/621 1.45 2500 80 31.5 31.5 31.5 31
WIB 8/38-2/627 1.45 630 80 31.5 31.5 31.5 31
WIB 8/38-2/627 1.45 1250 80 31.5 31.5 31.5 31
WIB 8/38-2/627 600 38 200 80 220/90 1.45 50/60 1600 80 31.5 31.5 31.5 31
WIB 8/38-2/627 1.45 2000 80 31.5 31.5 31.5 31
WIB 8/38-2/627 1.45 25002) 80 31.5 31.5 31.5 31
WIA 8/40.5-2/621 1.45 1250 80 31.5 31.5 31.5 31
WIA 8/40.5-2/621 185 215/90 1.45 1600 80 31.5 31.5 31.5 31
600 40.5 85 50
WIA 8/40.5-2/621 (200) (220/90) 1.45 2000 80 31.5 31.5 31.5 31
1.45 1)
WIA 8/40.5-2/621 2500 80 31.5 31.5 31.5 31
WIB 8/40.5-2/627 1.45 1250 80 31.5 31.5 31.5 31
WIB 8/40.5-2/627 185 215/90 1.45 1600 80 31.5 31.5 31.5 31
600 40.5 85 50
WIB 8/40.5-2/627 (200) (220/90) 1.45 2000 80 31.5 31.5 31.5 31
WIB 8/40.5-2/627 1.45 25002) 80 31.5 31.5 31.5 31
LS = Circuit-breaker
TS = Three-position switch, disconnector I/O
ES = Three-position switch, earthing switch I/O
1)
with cooling gas tank, panel height 2750 mm
2)
with motor-actuated fan
3)
for possible limit values and components fitted, refer to the project planning documents WI no. 49 542
4)
adm. tolerance range, is not a manufacturing tolerance, for the current value of a specimen, refer to the routine test report
5)
minimum service pressure at 20 C = 1.0 bar (overpressure)
30 WI EN
WI Selection tables (contd.)
O - 0.3 s - CO - 3 min - CO
4)
4)
CO - 15 s - CO
4)
Opening time
Opening time
Closing time
mechanism
LS,
TS,
On
Off
Off
E
On Off
A A kA ms ms ms ms ms ms ms s s
10000
1000
50 10 1000 10000 100 43-65 40-65 14 50 20 12 18
10000
1000
50 10 1000 10000 100 43-65 40-65 14 50 20 12 18
10000
1000
50 10 10000 100 43-65 40-65 14 50 20 12 18
1000
10000
1000
50 10 10000 100 43-65 40-65 14 50 20 12 18
1000
WI EN 31
WI Selection tables (contd.)
WIA/WIB 40.5 up to 52 kV
2 vacuum interrupter chambers per conductor
Rated insulation level
3)
withstand voltage
Rated frequency
Design pressure
making current
Rated voltage
Pr at 20 0C 5)
Panel width
component
current
1s 3s
mm kV kV kV kV/kV bar Hz A kA kA kA kA %
WIA 10/40.5-2/626 1.45 1250 100 40 40 40
600 40.5 200 80 220/90 50 26
WIA 10/40.5-2/626 1.45 25001) 100 40 40 40
LS = Circuit-breaker
TS = Three-position switch, disconnector I/O
ES = Three-position switch, earthing switch I/O
1)
with cooling gas tank, panel height 3314 mm and with motor-actuated fans
2)
with motor-actuated fan
3)
possible limits and components fitted, refer to project planning documents WI no. 49 542
4)
adm. tolerance range, no manufacturing tolerance, current value of one specimen, see routine test report
5)
minimum service pressure at 20 C: 0.1 bar at a filling pressure of 1.45 bar; 1.8 bar at a filling pressure of 2.2 bar
32 WI EN
WI
O - 3 min - CO - 3 min - CO
WI EN
O - 0.3 s - CO - 3 min - CO
sequence
CO - 15 s - CO
Rated operating
O - 0.3 s - CO - 15 s - CO
50
50
50
50
Cable breaking current
A
Small indirect currents
kA
under out-of-phase conditions
E
LS,
TS,
1000
1000
1000
1000
1000
1000
1000
1000
mech.
10000
10000
10000
10000
with rated (normal) current
10000
10000
10000
10000
overhaul
cycles without
electrical
100
100
100
100
breaking current
4)
ms
Opening time
50-80
25 W
50-80
50-80
50-80
4)
ms
Opening time
with release
4)
ms
Closing time
40-65
40-65
40-65
40-65
Operating times
160 W 160 W
14
14
14
14
Arc duration (max.)
ms
50
50
50
50
Off
ms
Selection tables (contd.)
Off
ms
On
with release
Command times
Off
On
ms
20
20
20
20
25 W 160 W 160 W
12
12
12
12
mechanism
Operating time for disconnector
s
33
WI Selection tables (contd.)
WIA/WIB 1 and 2-POLE, for stationary railway traction power supply 50/60 Hz
with 2 vacuum interrupter chambers per conductor
Rated insulation level
Type
withstand voltage
Design pressur e
Rated frequency
Pr bei 20 0C 5)
king current
Panel width
component
EN 50 124
EN 60 694
current
1s 3s
mm kV kV kV kV kV/kV bar Hz A kA kA kA kA %
WIA 6/55-S/626 1250 65 25 25
600 27.5 52 250 95 290/110 2.2 50/60 26
WIA 6/55-S/626 2000 65 25 25
WIA-Z 600 17.5 36 170 70 195/110 2.2 16 2/3 1250 80 31.5 31.5 46
LS = Circuit-breaker
TS = Three-position switch, disconnector I/O
ES = Three-position switch, earthing switch I/O
S = 1-pole
T = 2-pole
3)
without cooling gas tank and heat sink
4)
adm. tolerance range, no manufacturing tolerance, current value of one specimen, see routine test report
5)
minimum service pressure at 20 C 1.8 bar
34 WI EN
WI
O - 3 min - CO - 3 min - CO
WI EN
O - 0.3 s - CO - 3 min - CO
sequence
CO - 15 s - CO
Rated operating
O - 0.3 s - CO - 15 s - CO
50
50
50
Cable breaking current
A
Small indirect currents
kA
12.5
12.5
under out-of-phase conditions
E
LS,
TS,
1000
1000
1000
1000
1000
1000
mech.
10000
10000
with rated (normal) current
haul
10000 10000
10000
10000
electrical
100
100
100
cycles without over -
breaking current
4)
ms
Opening time
25 W
50-80
50-80
4)
ms
Opening time
25-35
with release
4)
ms
Closing time
40-50
40-50
40-50
Operating times
160 W 160 W
14
14
Arc duration (max.)
ms
6-68
50
50
Off
ms
Selection tables (contd.)
20
Off
ms
On
with release
Command time
Off
20
20
20
On
ms
25 W 160 W 160 W
12
12
12
mechanism
Operating time for disconnector
s
35
WI Range of products
Disconnector panel
With inner cone-type cable connection for
rated voltage up to 52 kV
rated short-time current up to 40 kA
rated busbar and outgoing feeder (normal) currents up to 2500 A
Busbar attachments
Panel connection
Panel attachment
connection
variants
1)
1)
1)
not possible in case of 52 kV
36 WI EN
WI Range of products (contd.)
Metering panel
for
rated voltage up to 36 kV
rated busbar (normal) current up to 2500 A
Circuit-breaker panel
(Inner cone-type cable connection)
Busbar attachments
SS2
SS1
Panel connection
attachment
variants
1)
Voltage Current
transformer, transformer
pluggable
Plug-in cable
single
1)
1)
1)
not possible in case of 52 kV
WI EN 37
WI Range of products (contd.)
SS2 SS2
SS1 SS1
Panel
connection Panel connection
attachment attachment
1) 1)
Panel Panel
Voltage connection Voltage Current
connection transformer, transformer, transformer
variants variants
pluggable pluggable
1) 1)
1) 1)
1)
not possible in case of 52 kV
38 WI EN
WI Range of products (contd.)
Current Current
transformer transformer
Bus coupler
up to 2000 A
(1 panel width) 1)
SS2
SS1
Current
transformer
only up to 40.5 kV
1)
Abbreviations
SS1 = Busbar 1
SS2 = Busbar 2
WI EN 39
WI Cable connections
40 WI EN
WI Cable connections (contd.)
WI EN 41
WI Cable connections (contd.)
42 WI EN
WI Ecological considerations
Materials Wt. %
Metals Steel 7
Copper 6.5
Aluminium, brass 2
Plastics Thermosetting plastics 7
Thermo-plastics 2
Elastomers 0.5
Electronics Plastics 0.5
Metals 1
Insulating gas Sulphur hexafluoride 0.5
WI EN 43
WI Design data
Space requirements - dimensions and
weights
>500
>500
WIA up to 40.5 kV WIA up to 52 kV
>500
2400
>500
2964
>1500 1)
>1000
>1000
>1500 1)
View
view
>500
>500
>1500 1)
>500
Topview
Top view
1692
70 70 280 70
Spacer bars 673
600
460
70
Flooringducts
Flooring ducts
1)
smaller gap on request
Weights:
WIA up to 40.5 kV approx. 1000 kg
WIA 52 kV approx. 1350 kg
44 WI EN
WI Design data
Space requirements - dimensions and
weights (contd.)
WIA up to 52 kV
>500
WIA up to 52 kV
>500
WIA up to 40.5 kV
>500
2400
>500 >500
2964
>1500 1)
>1000
>1000
>1500 1)
View
view
>500
>500
>500
>1500 1)
>500
Top view
1692
70 70 280 70
Spacer bars 673
600
460
70
Flooring ducts
1)
smaller gap on request
Weights:
WIA up to 40.5 kV max. 1000 kg
WIA 52 kV approx. 1350 kg
WI EN 45
WI Design data
Space requirements - dimensions and
weights (contd.)
WIB up to 40.5 kV
WIB bis 52 kV
>500
WIB bis 40,5 kV
>500
3614
>500
3050
>500 >500
>1500 1)
>1000
>1000
>1500 1)
view
View
>500
>500
1)
>500
>1500
>500
Top view
1692
70 70 280
Spacer bars 673
70
600
460
1)
smaller gap on request
70
Weights:
WIB up to 40.5 kV approx. 1300 kg
WIB 52 kV approx. 1700 kg
Flooring ducts
46 WI EN
WI Design data
Space requirements - dimensions and
weights (contd.)
WIB up to 52 kV
>500
WIB up to 40.5 kV WIB up to 52 kV
>500
3050
3614
>500
>500
>1500 1)
>1000
>1000
>1500 1)
view
View
>500
>500
>1500 1)
>500
Top view
Top view
1692
70 70 280
Spacer bars 673
70
600
460
70
1)
smaller gap on request
Weights:
WIB up to 40.5 kV approx. 900 - 1000 kg
WIB 52 kV approx. 1100 - 1500 Kg
Flooring ducts
Flooring ducts
WI EN 47
WI Design data
Space requirements - dimensions and
weights (contd.)
48 WI EN
WI Design data
Space requirements - dimensions and
weights (contd.)
Transfer
Transfer line
line at bottom.
at the the bottom.
Phase Phase exchange
exchange required inrequired in transfer line
transfer line
Transferline
Transfer line
toptop
andand bottom
bottom by of
by means means of supplementary
supplementary gas tank gas tank
Direct transfer
Direct line.line.
transfer Phase exchange
Phase in terminal
exchange tank
in terminal tank
WI EN 49
WI Shipping instructions
50 WI EN
Appendices Notes
WI EN 51
2011 Schneider Electric - All rights reserved
Schneider Electric As standards, specifications and designs change from time to time, please ask for
35, rue Joseph Monier confirmation of the information given in this publication.
CS 30323
This document has been printed
92506 Rueil-Malmaison Cedex, France
on ecological paper
RCS Nanterre 954 503 439 Publishing: Schneider Electric
Capital social 896 313 776 Design: Schneider Electric
www.schneider-electric.com Printing:
WI EN 02-2011