Professional Documents
Culture Documents
SC
EN
IC
CONTRACTOR NOTE:
LO
TRENCH BACKFILL AND PAYING FOR THE TESTS TO BE PERFORMED BY A THIRD PARTY.
OP
RANCH BOUNDARY
COMPACTION TEST WILL BE DONE AT ONE LOCATION POINT RANDOMLY SELECTED OR AS
R
SITE
D
INDICATED BY SAWS INSPECTOR/TEST ADMINISTRATOR, PER EACH 12 INCH LOOSE LIFT
PER 400 LINEAR FEET AT A MINIMUM.THIS PROJECT WILL NOT BE ACCEPTED AND ROW
JAMES M MIDDLETON BE TO
FINALIZED BY SAWS WITHOUT THIS REQUIREMENT BEING MET AND VERIFIED BY TRANSFORMER LOT 41, BLOCK 2 AU UT
PROVIDING ALL NECESSARY DOCUMENTED TEST RESULT A
ANAQU S RE AN BOE
VOL. 9563 PG. 169 GA T R
B.C.P.R. SPRING RD STA NE
RD GE SCALE: 1"=50'
FIRE HYDRANT LEAD FREE NOTE: CURB RD.
SAWS REQUIRES GCPS AND COUNTER PERMITS TO USE LEAD FREE (<0.25% LEAD) FIRE
HYDRANTS. 0 25' 50' 75' 100'
W W W
LOT 9 WATER MAIN INTO EX. 12" WATER MAIN (SAWS PROPOSED DUAL WATER SERVICE
RY JOB NO. 04-1301) W/ 5 L.F. OF 12" WATER MAIN
NDA PROPOSED SINGLE WATER SERVICE
OU CUT AS REQUIRED
TB
UNI
CONTRACTOR SHALL TIE INTO EX 12" AC MAIN PROPOSED FIRE HYDRANT
30' (SAWS JOB NO. 04-1301) AFTER FIELD ACCEPTED ENSURE SMOOTH TRANSITION EXISTING WATER LINE Wx
BLOCK 2 2" BLOWOFF ASSEMBLY (PERM)
BY SAWS AND PROPOSED 12" WATER MAIN (SAWS
JOB NO 16-1204) IS DISINFECTED AND ACCEPTED
TO EXISTING PAVEMENT
LOT 998 12" X 2" THR DI. ECCENTRIC REDUCER, M.J. (PERM) EXISTING FIRE HYDRANT
BY SAWS
SEE SAWS STD, DWG DD-844-02
RESTRAINED LENGTHS 33*
PROPOSED STUB OUT
FOR FUTURE EXPANSION
1.004 AC LIMITS OF
LOT 8 CONSTRUCTION
DRAIN "A"
55 LF OF 12" WATER MAIN
LOT 2
W BLOCK1
1.001 AC W ANAQUA SPRINGS
RANCH UNIT 2
Wx
LOT 7
PLAT # 040466
W
BLOCK 2
C.B. 4671 VOL. 9643 PG. 2349
B.C.R.P.R.
W
4*
W 4* SAWS JOB # 04-1301
238 LF OF 12" WATER MAIN
43*
ET) 43* 1~12" M.J. X 2" THR. D.I. ECCENTRIC FINISHED GROUND
TRE 43* BLOWOFF(TEMP.)
10' ELEC., GAS, TELE, A TE S W.) 1~ 12" 1/32 BEND
IV . W 2" BLOWOFF ASSEMBLY (TEMP.)
CA. TV., WATER AND (PR (50' R.O SEE SAWS STD. DWG DD 844-01
INGRESS/EGRESS S W
EASEMENT W R I NG 94 LF OF 12" WATER MAIN PROPOSED WATER
SP
CAT
W
4* FRANKY L HAMILTON
FOR CHLORINATION INJECTION CB 4671A BLOCK 7 LOT 16
4* VARIABLE WIDTH
W 170 LF OF 12" WATER MAIN 2~1" CORP.STOP C.C.X.I.P VOL. 16232 PG. 643
DRAINAGE EASEMENT
1.188 AC
W 2~1 1/4" THD SOLID CAP FOR MACHINE B.C.O.P.R.
LOT 6 CHLORINATION. CONTRACTOR TO
SEPARATION
1~ 12" 1/32 BEND 1 ~ 12" X 12" TEE, M.J. PROVIDE A 2" JUMPER TO LOAD NEW MAIN
12" MIN.
W W
2 ~ 8" GATE VALVE, M.J. W/BOX 1~COPPER TUBING, CUT AS REQUIRED
1~12"X6" ANCHOR TEE, M.J. 2~1" COMP. X 1 1/4" COUPLING CURB STOP
1~6" X 1/4 BEND, M.J.
1~6" GATE VALVE, M.J. 2.120 AC ELECTIRC PRIMARY,
1~6" VALVE BOX,COMPLETE LOT 1 SECONDARY OR SERVICES.
* 1~STD. FIRE HYDRANT
1~12"X6" ANCHOR TEE, M.J. 18* 18 167 LF OF 12" WATER MAIN
1~6" D.I. PIPE, CUT AS REQUIRED
1~6" X 1/4 BEND, M.J. SEE SAWS STD. DWG DD-834-01
W
FOR
Y
LOT 5
UN DAR
UN IT BO
VARIABLE WIDTH
DRAINAGE EASEMENT (VOL 9583, PG 169) 1-3" PVC CONDUIT
VARIABLE WIDTH
DRAINAGE EASEMENT TYPICAL CONDUIT DETAIL
N.T.S.
2%
1":1' MAX
R
3:1 MA
ALL A
REMAINING PORTION X
OF THE PATRICIA H. WALLACE
NAQU DARY