Professional Documents
Culture Documents
BOILER EFFICIENCY
Section: POG
Description Unit
(A) COAL DATA
(A1) PROXIMATE ANALYSIS OF COAL (As Fired Basis)
Moisture (+) %
Ash (+) %
Volatile Matter %
Fixed Carbon %
Unburnt Carbon in Fly Ash (+) %
Unburnt Carbon in Bottom Ash (+) %
Gross Calorific Value (+) KCAL/Kg
(A2) Values of Proximate Analysis (As Fired Basis) to Air Dried Basis
Moisture %
Ash %
Volatile Matter %
Fixed Carbon %
(A3)Proximate Analysis(ADB) to UItimate Analysis by Gebhard's Formula.
Carbon Content Of Coal %
Sulphur Content Of Coal %
Hydrogen Content Of Coal %
Oxygen Content Of Coal %
Nitrogen content Of Coal %
Moisture Content Of Coal %
(A4)UItimate Analysis (ADB) to Ultimate Analysis (AFB).
Carbon Content Of Coal (+) %
Sulphur Content Of Coal (+) %
Hydrogen Content Of Coal (+) %
Oxygen Content Of Coal (+) %
Nitrogen content Of Coal (+) %
AH-A gas inlet temp Deg C
AH-B gas inlet temp Deg C
AH-A gas outlet temp Deg C
AH-B gas outlet temp Deg C
% O2 at A/H-A inlet %
% O2 at A/H-B inlet %
% O2 at A/H-A outlet %
% O2 at A/H-B outlet %
(1) Loss Due To Unburnt Carbon %
(2) Loss Due To Dry Flue Gas %
(3) Loss Due To Moisture In Fuel %
(4) Loss Due To Burning Of Hydrogen %
(5) Loss Due To Moisture In AIR %
(6) Loss Due To Sensible Heat Of Bottom Ash %
(7) Loss Due To Sensible Heat Of Fly Ash %
(8) Loss Due To Radiation & Convection (predicted 0.19 %) %
(9) Loss Due To Mill Reject %
(10) Heat Credit %
BOILER EFFICIENCY (Operating) %
CORRECTED BOILER EFFICIENCY (Design Coal) %
Remarks:- 1) Boiler losses are more.
2) Coal GCV is 3333, 3286 ,3246 kcal/kg which is Lower than design CV of 3750,3750,3500 kcal/kg resp..
3) Hydrogen burning loss is more due to higher percentage of Hydrogen in coal.
4) Moisture is 15.42, 14.23, 14.10 % as against design value of 8 %,8% ,10%.
MSPGCL
FF - 8032(e)
Rev No: 01
Date: 29.04.2001
Unit-5 Unit-6 Unit-7
9/29/2016 9/6/2016 9/23/2016
cal/kg resp..