Design of Deaerator

Ww = ( Ws + Wm ) (time of mixing)
time of mixing (1-3) min ; use 3min
Ww = (70.64887 + 1.41297)kg/s(3min)
Ww = 70.06185 x 60s/min
Ww= 4323.71
Allowance = 10%
VD = 1 (Ww)
Density water

VD = 1.1 (4323.71)
1000

VD = 4.752

L = (3-6)m ; L = 3D

VD = D2 x L

4
Ds =3 4 x VD
3
Ds =3 4 x 4.752
3
Ds = 1.2634 m

L = 3D = 3(1.2634)
L = 3.7902
ts = P6Ds
2Sd
From Design of Machine Elements by Virgil Moring Faires
Table 7 Material 1340 OQT 1200. Sy = 66000 psi F.S. = 6
ts = ( 145.0777)( 1.2634)(3.28ft)
2(66000/6)
ts = 0.008314 m
ts= 8.3314 mm or 0.328 in
DESIGN OF
DEAERATOR
Figure Deaerator

Feedwater to be supplied into steam boiler should pass deaerator


equipment. Deaerator has main functions as follow: to get rid of the
gasses contained in feedwater, in this case feedwater had been
processed and purified in water treatment plant and has function as
initial heater before supplied into steam boiler. Deaerator works based
on the nature of oxygen solubility in water decrease with an increase in
temperature.