Addendum
2nd Edition
SERIES
3
MSZ-HJ25/ 35/50VA
MSZ-H
MSZ-HJ60/71VA
SERIES
Compact, high-performance indoor and outdoor units and advanced inverter
technologies provide superior energy savings and comfort in all rooms.
SEER
25/35
SCOP
50/60/71
SEER
50/60/71
SCOP
Efficient Operation All the Time A A A+ A+
Mitsubishi Electrics cutting-edge inverter technologies are adopted to provide automatic adjustment of operation load according to need. This
reduces excessive consumption of electricity, and thereby realises an Energy Rank A rating for 25/35 classes and A+ for 50/60/71 classes.
Silent Operation
Quiet, relaxing space is within reach. Operational noise is a low 22dB Noise Level
(25/35 classes). Operation is so silent you might even forget the air
Quiet passenger Human
conditioner is on. Subway car car interior Sound of hearing limits
Library interior
interior (40km/h) rustling leaves (Extremely quiet)
Compact Units
The widths of both indoor and outdoor units are compact, making Compared to previous models, width is down by 16%.
installation in smaller, tighter spaces possible.
Previous
Indoor Unit: MSZ-HJ25/35/50VA Outdoor Unit: MUZ-HJ25/35VA Indoor Unit:
MSZ-GF60/71VE
1100mm
16%
Down
New
Only 799mm width
Indoor Unit:
m width
Only 699m
MSZ-HJ60/71VA
923mm
4
A+++
A++
A+
A
B ErP
C
D
MSZ-H SERIES
SEER SCOP
Please fill out the requested information
Please fill out the requested information
A+ A+
MUZ-HJ25/35VA MUZ-HJ50VA
MSZ-HJ25/35/50VA
MUZ-HJ60/71VA
MSZ-HJ60/71VA
Silver-ion
Optional
MSZ-HJ SERIES
Type Inverter Heat Pump
Indoor Unit MSZ-HJ25VA MSZ-HJ35VA MSZ-HJ50VA MSZ-HJ60VA MSZ-HJ71VA
Outdoor Unit MUZ-HJ25VA MUZ-HJ35VA MUZ-HJ50VA MUZ-HJ60VA MUZ-HJ71VA
Refrigerant R410A(*1)
Power Source Indoor Power supply
Supply Outdoor ( V / Phase / Hz ) 230V/Single/50Hz
Design load kW 2.5 3.1 5.0 6.1 7.1
Annual electricity consumption (*2) kWh/a 171 212 292 354 441
SEER (*4) 5.1 5.1 6.0 6.0 5.6
Cooling Energy efficiency class A A A+ A+ A+
Rated kW 2.5 3.15 5.0 6.1 7.1
Capacity
Min-Max kW 1.3 - 3.0 1.4 - 3.5 1.3 - 5.0 1.7 - 7.1 1.8 - 7.1
Total Input Rated kW 0.730 1.040 2.050 1.900 2.330
Design load kW 1.9 (-10C) 2.4 (-10C) 3.8 (-10C) 4.6 (-10C) 5.4 (-10C)
at reference design temperature kW 1.9 (-10C) 2.4 (-10C) 3.8 (-10C) 4.6 (-10C) 5.4 (-10C)
Declared
at bivalent temperature kW 1.9 (-10C) 2.4 (-10C) 3.8 (-10C) 4.6 (-10C) 5.4 (-10C)
Capacity
at operation limit temperature kW 1.9 (-10C) 2.4 (-10C) 3.8 (-10C) 4.6 (-10C) 5.4 (-10C)
Heating Back up heating capacity kW 0.0 (-10C) 0.0 (-10C) 0.0 (-10C) 0.0 (-10C) 0.0 (-10C)
(Average Annual electricity consumption (*2) kWh/a 698 885 1267 1544 1854
(*5)
Season) SCOP (*4)
3.8 3.8 4.2 4.1 4.0
Energy efficiency class A A A+ A+ A+
Rated kW 3.15 3.6 5.4 6.8 8.1
Capacity
Min-Max kW 0.9 - 3.5 1.1 - 4.1 1.4 - 6.5 1.5 - 8.4 1.5 - 8.5
Total Input Rated kW 0.870 0.995 1.480 1.970 2.440
Operating Current (Max) A 5.8 6.5 9.8 12.5 12.5
Input Rated kW 0.020 0.021 0.037 0.055 0.055
Operating Current(Max) A 0.3 0.3 0.4 0.5 0.5
Dimensions H*W*D mm 290-799-232 290-799-232 290-799-232 305-923-250 305-923-250
Weight kg 9 9 9 13 13
Indoor
Air Volume (SLo-Lo- Cooling m3/min 3.8 - 5.5 - 7.3 - 9.5 3.8 - 5.7 - 7.8 - 10.9 6.3 - 9.1 - 11.1 - 12.9 9.3 - 12.2 - 15.0 - 19.9 10.0 - 12.2 - 15.0 - 19.9
Unit
Mid-Hi-SHi(*3)(Dry/Wet)) Heating m3/min 3.5 - 5.5 - 7.5 - 10.0 3.5 - 5.5 - 7.5 - 10.3 6.1 - 8.3 - 11.1 - 14.3 9.4 - 12.5 - 16.0 - 19.9 10.3 - 12.7 - 16.4 - 19.9
Sound Level (SPL) Cooling dB(A) 22 - 30 - 37 - 43 22 - 31 - 38 - 45 28 - 36 - 40 - 45 31 - 38 - 44 - 50 33 - 38 - 44 - 50
(SLo-Lo-Mid-Hi-SHi(*3)) Heating dB(A) 23 - 30 - 37 - 43 23 - 30 - 37 - 44 27 - 34 - 41 - 47 31 - 38 - 44 - 49 33 - 38 - 44 - 49
Sound Level (PWL) Cooling dB(A) 57 60 60 65 65
Dimensions H*W*D mm 538-699-249 538-699-249 550-800-285 880-840-330 880-840-330
Weight kg 24 25 36 55 55
Cooling m3/min 31.5 31.5 36.3 47.9 49.3
Air Volume 3
Heating m /min 31.5 31.5 34.8 47.9 47.9
Outdoor
Cooling dB(A) 50 50 50 55 55
Unit Sound Level (SPL)
Heating dB(A) 50 50 51 55 55
Sound Level (PWL) Cooling dB(A) 63 64 64 65 66
Operating Current (Max) A 5.5 6.2 9.4 12 12
Breaker Size A 10 10 12 16 16
Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7 6.35/15.88 9.52/15.88
Ext.
Max.Length Out-In m 20 20 20 30 30
Piping
Max.Height Out-In m 12 12 12 15 15
Guaranteed Operating Cooling C +15 ~ +46 +15 ~ +46 +15 ~ +46 +15 ~ +46 +15 ~ +46
Range (Outdoor) Heating C -10 ~ +24 -10 ~ +24 -10 ~ +24 -10 ~ +24 -10 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on Average Season.
(*5) Please see page 47 for heating (warmer season) specifications.
5
MSH-GF SERIES MSH-GF25/35VA
MSH-GF50/60/80VA
The unique product series: The perfect combination of cooling and heating
capability. MSH-GF series, featuring Easy Clean Design and a highly effective
Nano Platinum air purifying system, brings the most comfort to your room.
Furthermore, the perfect combination of cooling and heating capability in a deluxe
unit so much saves your investment expense.
Cool up to +46C
Cooling operation up to +46C for all MSH-GF serie.
6
MSH-GF SERIES SERIES SELECTION
Indoor Unit Outdoor Unit
MSH-GF25/35VA
MUH-GF25/35/50VA MUH-GF60/80VA
MSH-GF50/60/80VA
Remote Controller
MSH-GF SERIES
Type Fixed-Speed - Heat Pump
Indoor Unit MSH-GF25VA MSH-GF35VA MSH-GF50VA MSH-GF60VA MSH-GF80VA
Outdoor Unit MUH-GF25VA MUH-GF35VA MUH-GF50VA MUH-GF60VA MUH-GF80VA
Refrigerant R410A
Power Source Outdoor Power Supply
Supply Outdoor ( V / Phase / Hz ) 230 V/ Single / 50
Capacity Rated kW 2,65 3,40 4,90 6,20 7,70
Min-Max kW - - - - -
Cooling Total Input Rated kW 0,82 1,07 1,77 2,00 2,80
EER 3,23 3,18 2,77 3,10 2,75
SPL Indoor Unit (Low/High) dBA 25 - 36 26 - 40 34 - 42 37 - 45 39 - 47
Capacity Rated kW 3,00 3,70 5,10 6,70 8,50
Min-Max kW - - - - -
Heating Total Input Rated kW 0,82 1,08 1,50 2,10 2,82
COP 3,66 3,43 3,40 3,19 3,01
SPL Indoor Unit (Low/High) dBA 25 - 36 26 - 40 37 - 45 34 - 45 37 - 47
Operating Current (Cool) A 3,9 4,8 8,1 9,1 12,6
Operating Current (Heat) A 3,9 5,0 6,9 9,5 12,7
Dimensions HxWxD mm 295 - 798 - 232 295 - 798 - 232 325 - 1100 - 238 325 - 1100 - 238 325 - 1100 - 238
Indoor
Weight kg 9 9 16 16 16
Unit
Air Volume Indoor Unit (High) m3/min 7,9 8,8 14,1 16,7 18,7
Outdoor Dimensions HxWxD mm 550 - 800 - 285 550 - 800 - 285 550 - 800 - 285 880 - 840 - 330 880 - 840 - 330
Unit Weight kg 33 39 40 67 76
Diameter Liquid/Gas mm 6,35 / 9,52 6,35 / 9,52 6,35 / 12,7 6,35 / 15,88 9,52 / 15,88
Ext.
Max. Length Out-In m 20 25 30 30 30
Piping
Max. Height Out-In m 10 10 10 10 15
Guaranteed Operating Cooling C 21 ~ 46 21 ~ 46 21 ~ 46 21 ~ 46 21 ~ 46
Range (Outdoor DryBulb ) Heating C -10 ~ 24 -10 ~ 24 -10 ~ 24 -10 ~ 24 -10 ~ 24
7
MS-GF18/24/30VC
MS
MS-GF10/13VC
SERIES MS-D36VC
MS
+21 [C] +52 [C]
(18-24-30-36)
8
MS SERIES SERIES SELECTION
Indoor Unit Outdoor Unit
MS-GF10/13VC
MU-GF30VC
MU-GF10/13/VC
MS-GF18/24/30VC
Remote Controller
MS 10/13 MS 18/24/30/36
MS SERIES
Type Fixed - Speed
Indoor Unit MS-GF10VC MS-GF13VC MS-GF18VC MS-GF24VC MS-GF30VC MS-D36VC
Outdoor Unit MU-GF10VC MU-GF13VC MU-GF18VC MU-GF24VC MU-GF30VC MU-D36VC
Refrigerant R22
Power Source Indoor Power supply Outdoor Power supply
Supply V / Phase / Hz 230/Single/50
Rated kW 2,75 3,65 5,2 6,9 8,4 10,55
Capacity
Min-Max kW - - - - - -
Cooling Total Input Rated kW 0,85 1,24 1,81 2,64 3,1 3,40
EER 3,24 2,94 2,87 2,61 2,71 3,11
SPL Indoor Unit [Lo-High] dB(A) 26 - 39 29 - 42 33 - 42 37 - 45 37 - 45 39-50
Operating Current (Max) A 3,9 5,7 8,7 11,7 14 15,7
Dimensions HxWxD mm 295 - 798 - 232 295 - 798 - 232 325 - 1100 - 238 325 - 1100 - 238 325 - 1100 - 238 365 - 1170 - 295
Indoor
Weight kg 9 9 16 16 16 18
Unit
Air Volume Indoor Unit (High) m3/min 9,1 9,6 15,3 17,1 17,1 24,2
Outdoor Dimensions HxWxD mm 525 - 718 - 255 525 - 718 - 255 550 - 800 - 285 605 - 850 - 290 880 - 840 - 330 1258 - 870 - 295
Unit Weight kg 24 28,5 37 51 71 88
Diameter Liquid/Gas mm 6,35 / 9,52 6,35 / 12,7 6,35 / 12,7 6,35 / 15,88 9,52 / 15,88 9,52 / 15,88
Ext.
Max.Length Out-In m 20 20 30 30 30 30
Piping
Max.Height Out-In m 10 10 10 10 15 15
Guaranteed Operating
Cooling C +21 ~ +43 +21 ~ +43 +21 ~ +52 +21 ~ +52 +21 ~ +52 +21 ~ +52
Range (Outdoor)
9
SERIES
10
PLA SERIES
A complete line-up including deluxe units that offer added energy savings. The in-
corporation of wide air-outlet and the i-see Sensor enhances airow distribution
PLA-SP71/100/125/140
control, achieving an enhanced level of comfort throughout the room. The synergy
of higher energy efciency and more comfortable room environment results in the
utmost user satisfaction.
Optimum Airow
Individual Vane Settings Wide Airflow Image of multi-directional
Optimum airflow settings provide maximum Wide-angle outlets distribute airflow air conditioning
Individual Vane
Wide Airflow
Horizontal
New 4-Way Ceiling Cassette Setting
Airow direction at
each vane can be set
using the wired remote The combination of individual vane setting,
controller. Fixed which enables the optimal outlet setting for
Adjustable
Downward each room layout, and the wide airflow function
works to ensure even temperature distribution
throughout each room. The result is uniformly
72 airflow patterns comfortable air conditioning.
2 A more
Height (m)
horizontal airflow
Horizontal is achieved using
1 Airflow the new mode.
When the room temperature reaches
0 the desired setting, the airflow speed
5 4 3 2 1 0
Floor distribution (m) is decreased automatically for stable
] Smudge spots on the ceiling may form where the airow is not evenly distributed. comfortable heating/cooling operation. Gentle
11
DOES HAVING COLD FEET BOTHER YOU?
The i-see Sensor is the answer to your problems!
Heating Cooling
Mode Mode
Warm air rises Legs and feet
to the ceiling! feel cold!
or
The i-see Sensor is an innovative Mitsubishi Electric technology Corner Panel Only (Option)
90 90 90
rotation rotation rotation
that uses a radiation-based sensor to monitor temperature through-
out an entire room. When connected to the air conditioner control 5 sec
measurement
5 sec
measurement
5 sec
measurement
5 sec
measurement
Room air
25C 25C
warmed to
floor level
13C 13C
Temperature gap Temperature gap minimized
Temperature felt: 17C (floor level 14C) Temperature felt: 20C (floor level 20C)
Warm air rises to the ceiling. This causes poor heating at floor level, The i-see Sensor detects the temperature at the floor while the
leaving legs and feet feeling cold. Automatic Air-speed Adjustment eliminates uneven temperature
distribution by thoroughly warming the air down to the floor.
14C
14C
Temperature felt: 26.5C
The temperature felt drops according to the drop in floor-level Temperature Felt: 28C
temperature. If the floor-level temperature is not monitored during Air temperature is adjusted according to the floor temperature to
long cooling operation, the temperature felt becomes chilly. keep the temperature felt at 28C.
12
A+++
A++
ErP
A+
A
B
C
D
Optional
PLP-6BA - Panel only
PLP-6BALM - Panel with wireless remote controller
PLP-6BALME - Panel with i-see Sensor + wireless remote controller
PLA SERIES
SERIES
Type Inverter Heat Pump
Type Inverter Heat Pump
Indoor Unit PLA-SP71BA PLA-SP100BA PLA-SP100BA PLA-SP125BA PLA-SP140BA
Indoor Unit PLA-SP71BA PLA-SP100BA PLA-SP125BA PLA-SP140BA
Outdoor Unit SUZ-SA71VA2 SUZ-SA100VA PUHZ-SP100YHA PUHZ-SP125VHA (YHA) PUHZ-SP140VHA (YHA)
Outdoor Unit SUZ-SA71VA PUHZ-SP100VHA (YHA) PUHZ-SP125VHA (YHA) PUHZ-SP140VHA (YHA)
Refrigerant R410A(*1)
Refrigerant R410A *1
Power Source Outdoor power supply
Power Source Outdoor Power supply
Supply Outdoor ( V / Phase / Hz ) V: 230 / Single / 50 / (Y: 400/Three/50)
Supply Outdoor ( V / Phase / Hz ) V: 230 / Single / 50 / (Y: 400/Three/50)
Rated kW 7,1 9,4 9,4 12,3 13,0
Capacity Rated kW 7,1 9,4 12,3 13,0
Capacity Min-Max kW 3.2 - 8.1 5.0 - 9.9 4.9 - 9.9 5.5 - 13.0 5.5 - 14.0
Min-Max kW 2.8 - 8.1 4.9 - 9.9 5.5 - 13.0 5.5 - 14.0
Total
TotalInput
Input Rated
Rated kW
kW 2,222.21 3,12 3,12 3,12 4,08 4,08 4,984,98
EER
EER 3,203,01 3,01 3,01 3,01 3,01 3,01 2,612,61
Cooling
Cooling Design load
Design load kW
kW 7,1 7,1 9,4 9,4 9,4 - - - -
Annual
Annualelectricity
electricityconsumption
consumption*2 *2 kWh/a
kWh/a 387 443 610 644 522 - - - -
SEER
SEER 5,6 5,6 5,1 5,1 5,1 - - - -
Energy
Energyefficiency
efciencyclassclass A+ A+ A A A - - - -
Rated
Rated kW
kW 8,0 8,0 11,2 11,2 11,2 13,5 13,5 15,515,5
Capacity
Capacity Min-Max
Min-Max kW
kW 3.5 -2.6
8.9- 8.9 5.1 - 11.5 4.5 -11.5 4.5 -11.5 5.0 - 15.0 5.0 - 15.0 5.0 - 17.0
5.0 - 17.0
Total Input
Total Input Rated
Rated kW
kW 2,492,49 3,48 3,49 3,49 4,0 3,96 4,04,83
COP
COP 3,21 3,2 3,21 3,21 3,21 3,4 3,41 3,23,21
Design
Designload
load kW
kW 5,8 5,8 8,0 8 8,0 - - - -
Heating
Heating atatreference
(Average referencedesign
designtemperature
temperature kWkW 4.7 (-10C)
4.7 (-10C) 5,9 (-10C) 6.3 (-10C) 6.3 (-10C) - - - -
(Average Declared
Declared at bivalent temperature kW 5.2 (-7C) 7,1 (-7C) 7.1 (-7C) -
Season)
Season) Capacity at bivalent temperature kW 5.1 (-7C) 7.1 (-7C) - - -
Capacity
atatoperation
operationlimit
limittemperature
temperature kW
kW 4.7 (-10C)
4.7 (-10C) 5,9 (-10C) 5.0 (-15C) 5.0 (-15C) - - - -
Back
Backupupheating
heatingcapacity
capacity kW
kW 1,1 1,1 2,1 1,7 1,7 - - - -
Annual electricity consumption
Annual electricity consumption *2 *2 kWh/a
kWh/a 15212131 2800 2945 2511 - - - -
SCOP
SCOP 3,9 3,8 3,8 3,8 3,8 - - - -
Energy
Energyefficiency
efciencyclassclass A A A A A - - - -
Operating
OperatingCurrent
Current(Max)
(Max) AA 16,616,6 28,9 28,9 (13,9) 13,9 29 (14) 29 (14) 30,530.5
(14)(14)
Input
Input Rated
Rated kW
kW 0,070,07 0,140,14 0,15 0,15 0,20,15
Operating Current(Max)
Operating Current(Max) AA 0,510,51 0,940,94 1 1,00 1,01,00
Dimensions
Dimensions HxWxD
HxWxD mm
mm 258-840-840 258-840-840
<35-950-950><35-950-950> 298-840-840 <35-950-950> 298-840-840 <35-950-950>298-840-840 <35-950-950>
Indoor
Indoor Weight
Weight kg
kg 23 <6>23 <6> 25 <6> 25 <6> 25 <6> 27 <6>
27 <6>
Unit
Unit
Air
AirVolume
Volume(Lo-Mi2-Mi1-HI)
(Lo-Mi2-Mi1-HI) mm33/min
/min 14-16-18-21
14-16-18-21 20-23-26-30
20-23-26-30 22-25-28-31 22-25-28-31 24-26-29-32
24-26-29-32
Sound Level (SPL) (Lo-Mi2-Mi1-Hi)
Sound Level (SPL) (Lo-Mi2-Mi1-Hi) dB(A)
dB(A) 28-30-32-34
28-30-32-34 32-34-37-40
32-34-37-40 34-36-39-41 34-36-39-41 36-39-42-44
36-39-42-44
Sound
SoundLevel
Level(PWL)
(PWL) dB(A)
dB(A) 58 56 62 62 63 63 70,0 70
Dimensions
Dimensions HxWxD
HxWxD mm
mm 880 - 840 - 880
330 - 840 - 330 943-950-330(+30) 943-950-330(+30) 1350-950-330(+30) 1350-950-330(+30) 1350-950-330(+30)
1350-950-330(+30)
Weight
Weight kg
kg 52 53 56 75 (77) 77 99 (101) 99 (101) 99 (101)
99 (101)
33
Cooling
Cooling mm /min
/min 58,250,1 57,1 60,0 60,0 100 100 100100
Air
AirVolume
Volume
Heating
Heating mm33/min
/min 49,248,2 54,6 60,0 60,0 100 100 100100
Outdoor
Outdoor Cooling
Cooling dB(A)
dB(A) 55 55 55 50,0 50 51 51 52 52
Unit
Unit Sound
SoundLevel
Level(SPL)
(SPL)
Heating
Heating dB(A)
dB(A) 55 55 55 54,0 54 55 55 56 56
Sound
SoundLevel
Level(PWL)
(PWL) Cooling
Cooling dB(A)
dB(A) 65 69 70 70,0 70 71 70 73 70
Operating
OperatingCurrent
Current(Max)(Max) AA 16,116,1 28 28 (13) 13 28 (13) 28 (13) 29,529,5
(13)(13)
Breaker
BreakerSize
Size AA 20 20 20 32 (16) 16 32 (16) 32 (16) 40 (16)
40 (16)
Diameter
Diameter Liquid/Gas
Liquid/Gas mm
mm 9.52 9.52
/ 15.88
/ 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.889.52 / 15.88 9.529.52 / 15.88
/ 15.88
Ext.
Ext.
Max.Length
Max.Length Out-In
Out-In mm 30 30 30 30 30 40 40 40 40
Piping
Piping
Max.Height
Max.Height Out-In
Out-In mm 30 30 30 30 30 30 30 30 30
GuaranteedOperating
Guaranteed Operating Cooling
Cooling CC -10 ~-10+43~ +46 -10 ~ +46 -15 ~~ +46
-15 +46 -15 ~ +46 -15 -15
~ +46
~ +46
Range(Outdoor)
Range (Outdoor) Heating
Heating CC -10 ~-10+24~ +24 -10 ~ +24 -15 ~~ +21
-15 +21 -15 ~ +21 -15 -15
~ +21
~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to
the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming
would be 1975 times higher than 1 kg of CO2 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
13
PL SERIES
The incorporation of wide air-outlet enhances airflow distribution control, achiev-
ing an enhanced level of comfort throughout the room. The synergy of higher
PL-2/2.5/3/4/5/6 BAK
energy efficiency and more comfortable room environment results in the utmost
user satisfaction.
*This feature will not activate when the vane is set at the fixed position.
Automatic air-
Low Medium 2 Medium 1 High speed adjustment
(When using the wireless remote controller, an extra setting is required.)
14
PL SERIES SERIES SELECTION
Indoor Unit Outdoor Unit
Panel Variety
PLP-6BAMD - Wired remore control included (PAR-21MAA)
PAR-21MAA
PL SERIES
Type Fixed - Speed
Indoor Unit PL-2BAK PL-2.5BAK PL-3BAK PL-4BAK PL-5BAK PL-6BAK
Outdoor Unit PU-2VAKD PU-2.5VAKD PU-3VAKD PU-4V/YAKD2 PU-5YAKD PU-6YAKD
Refrigerant R22
Source Indoor / Outdoor Separate Power Supply
Power
Supply 230 / Single / 50 230 / Single / 50 230 / Single / 50 230 / Single / 50; 400 / Three / 50 400 / Three / 50
V / Phase / Hz
400 /Three / 50
Capacity Rated kW 5,3 6,7 7,9 10,3 13,1 15
Cooling Total Input Rated kW 1,96 2,36 3,34 (V)3,71 (Y) 3,64 4,35 5,38
EER 2,70 2,84 2,37 (V) 2,78(Y) 2,83 3,01 2,79
Dimensions 258 x 840 x 840 258 x 840 x 840 258 x 840 x 840 298 x 840 x 840 298 x 840 x 840 298 x 840 x 840
HxWxD mm
(Panel) <35 x 950 x 950> <35 x 950 x 950> <35 x 950 x 950> <35 x 950 x 950> <35 x 950 x 950> <35 x 950 x 950>
Indoor Weight (Panel) kg 22 <6> 23 <6> 23 <6> 25 <6> 27 <6> 27 <6>
Unit Air Volume m3/min 12 - 13 -14 - 16 12 - 14 - 16 - 18 14 - 16 - 18 - 20 20 - 22 - 25 - 28 22 - 24 - 27 - 30 24 - 26 - 29 - 32
External Static Pressure Pa 0 0 0 0 0 0
Sound Level dB(A) 28-29-30-32 28-29-31-33 28-30-32-34 33-35-38-41 35-37-39-42 37-39-41-44
Dimensions HxWxD mm 605 x 850 x 290 605 x 850 x 290 850 x 840 x 330 1258 x 870 x 295 1258 x 970 x 345 1258 x 970 x 345
Outdoor Weight kg 45 52 69 83 111 112
Unit Air Volume Cooling m3/min 38 39 49 95 100 100
Sound Level Cooling dB(A) 50 52 53 54 55 56
Diameter Liquid/Gas mm 9,52 / 15,88 9,52 / 15,88 9,52 / 15,88 9,52 / 19,05 9,52 / 19,05 9,52 / 19,05
Ext.
Max. Length Out-In m 30 30 30 40 50 50
Piping
Max. Height Out-In m 10 10 15 30 50 50
Guaranteed Operating
Cooling C +21 +46 +21 +46 +21 +52 +21 +46 +21 +46 +21 +46
Range (Outdoor)
15
PC SERIES
PC-3/4/5/6KAK
A stylish new indoor unit design and airflow settings for both high and low ceiling
interiors expand installation possibilities. Together with exceptional energy-saving
performance, these units are the solution to diversified air conditioning needs.
Strong Gentle
16
PC SERIES SERIES SELECTION
Indoor Unit Outdoor Unit
Remote Controller
PAR-21MAA included
PC SERIES
Type Fixed - Speed
Indoor Unit PC-3KAK PC-4KAK PC-5KAK PC-6KAK
Outdoor Unit PU-3VAKD PU-4V/YAKD2 PU-5YAKD PU-6YAKD
Refrigerant R22
Source Indoor / Outdoor Separate Power Supply
Power
Supply V / Phase / Hz 230 / Single / 50 230 / Single / 50; 400 / Three / 50 400 / Three / 50
400 /Three / 50
Capacity Rated kW 7,9 10,3 12,8 14,4
Cooling Total Input Rated kW 3,31 (V) 3,61/ (Y) 3,54 4,2 5,22
EER 2,39 2,85/2,91 3,05 2,76
Dimensions
HxWxD mm 230 x 1280 x 680 230 x 1600 x 680 230 x 1600 x 680 230 x 1600 x 680
(Panel)
Indoor Weight (Panel) kg 32 36 38 39
Unit Air Volume m3/min 16-22 24-30 25-32 27-34
External Static Pressure Pa 0 0 0 0
Sound Level dB(A) 34-42 39-45 40-46 42-48
Dimensions HxWxD mm 850 x 840 x 330 1258 x 870 x 295 1258 x 970 x 345 1258 x 970 x 345
Outdoor Weight kg 69 83 111 112
Unit Air Volume Cooling m3/min 49 95 100 100
Sound Level Cooling dB(A) 53 54 55 56
Diameter Liquid/Gas mm 9,52/15,88 9,52/19,05 9,52/19,05 9,52/19,05
Ext.
Max. Length Out-In m 30 40 50 50
Piping
Max. Height Out-In m 15 30 50 50
Guaranteed Operating
Cooling C +21 +52 +21 +46 +21 +46 +21 +46
Range (Outdoor)
17
PEAD SERIES
PEAD-SP71/100/125/140JA(L)
The thin, ceiling-concealed indoor units of this series are the perfect answer for the air
conditioning needs of buildings with minimum ceiling installation space and wide-
ranging external static pressure. Energy-saving efficiency has been improved, reduc-
ing electricity consumption and contributing to a further reduction in operating cost.
Reduction of
250 mm 75mm
(models 100 140)
compared to PEAD-EA
PEAD-SP JA(L)
18
A+++
A++
ErP
A+
A
B
C
D
PEAD-SP JA
SUZ-SA71VA2 PUHZ-SP100YHA PUHZ-SP125/140VHA/YHA
SUZ-SA100VA
PEAD-SP SERIES
Type Inverter Heat Pump
Indoor Unit PEAD-SP71JA(L) PEAD-SP100JA(L) PEAD-SP100JA(L) PEAD-SP125JA(L) PEAD-SP140JA(L)
Outdoor Unit SUZ-SA71VA2 SUZ-SA100VA PUHZ-SP100YHA PUHZ-SP125VHA (YHA) PUHZ-SP140VHA (YHA)
Refrigerant R410A(*1)
Power Source Outdoor power supply
Supply Outdoor ( V / Phase / Hz ) V: 230 / Single / 50, Y: 400/Three/50
Rated kW 7,1 9,4 9,4 12,3 13,0
Capacity
Min-Max kW 3.5 - 8.1 5.0 - 9.9 4.9 - 9.9 5.5 - 13.0 5.5 - 14.0
Total Input Rated kW 2,35 3,12 3,12 4,38 4,32
EER 3,02 3,01 3,01 2,81 3,01
Cooling
Design load kW 7,1 9,4 9,4 - -
Annual electricity consumption *2 kWh/a 446 593 602 - -
SEER 5,2 4,6 4,6 - -
Energy efficiency class A B B - -
Rated kW 8,0 11,2 11,2 13,5 15,5
Capacity
Min-Max kW 3.5 - 8.9 5.1 - 11.5 4.5 - 11.5 5.0 - 15.0 5.0 - 17.0
Total Input Rated kW 2,21 3,10 3,10 3,74 4,55
COP 3,61 3,61 3,61 3,61 3,41
Design load kW 6,0 8,0 8,0 - -
Heating at reference design temperature kW 5.2 (-10C) 6,4 (-10C) 6.3 (-10C) - -
(Average Declared
Season) Capacity at bivalent temperature kW 5.4 (-7C) 7,1 (-7C) 7.1 (-7C) - -
at operation limit temperature kW 5.2 (-10C) 6,4 (-10C) 5.0 (-15C) - -
Back up heating capacity kW 0,8 1,6 1,7 - -
Annual electricity consumption *2 kWh/a 1762 2627 2627 - -
SCOP 3,8 3,8 3,8 - -
Energy efficiency class A A A - -
Operating Current (Max) A 18,1 28,9 15,7 30.8 (15.8) 32.3 (15.8)
Input Rated kW 0.17 / 0.15 0.25 / 0.23 0.36 / 0.34 0.39 / 0.37
Operating Current(Max) A 1,97 2,65 2,76 2,78
Dimensions HxWxD mm 250-1100-732 250 - 1400 - 732 250 - 1600 - 732
Indoor Weight kg 33(32) 41(40) 43(42) 47(46)
Unit Air Volume (Lo-Mi2-Mi1-HI) m3/min 17.5 - 21.0 - 25.0 24.0 - 29.0 - 34.0 29.5 - 35.5 - 42.0 32.0 - 39.0 - 46.0
External Static Pressure Pa 35 / 50 / 70 / 100 / 150
Sound Level (SPL) (Lo-Mi2-Mi1-Hi) dB(A) 26 - 30 - 34 29 - 34 - 38 33 - 36 - 40 34 - 38 - 43
Sound Level (PWL) dB(A) 67 69 65 66
Dimensions HxWxD mm 880 - 840 - 330 943-950-330(+30) 1350-950-330(+30) 1350-950-330(+30)
Weight kg 52 56 77 99 (101) 99 (101)
Cooling m3/min 58,2 57,1 60,0 100,0 100,0
Air Volume 3
Heating m /min 49,2 54,6 60,0 100,0 100,0
Outdoor
Cooling dB(A) 55 55 50 51 52
Unit Sound Level (SPL)
Heating dB(A) 55 55 54 55 56
Sound Level (PWL) Cooling dB(A) 65 70 70 70 70
Operating Current (Max) A 16,1 28 13 28 (13) 29.5 (13)
Breaker Size A 20 20 16 32 (16) 40 (16)
Diameter Liquid/Gas mm 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Ext.
Max.Length Out-In m 30 30 30,0 40 40
Piping
Max.Height Out-In m 30 30 30,0 30 30
Guaranteed Operating Cooling C -10 ~ +46 -10 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46
Range (Outdoor) Heating C -10 ~ +24 -10 ~ +24 -15 ~ +21 -15 ~ +21 -15 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to
the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming
would be 1975 times higher than 1 kg of CO2 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
19
PE-3EAK2 PE-4EAK
PE
PE-5EAK2
PE-6EAK2
SERIES
For elegance and style, the PE Series compliments the room environment with an
aesthetically pleasing ceiling installation and a vast line-up of performance functions.
Long pipe work installation is supported, increasing freedom in the placement of
indoor units.
Room with
fixed ceiling
L- shaped room fixtures
20
PE SERIES SERIES SELECTION
Indoor Unit Outdoor Unit
PE-3EAK2 PE-4EAK
PU-3VAKD PU-4V/YAKD
PE-5EAK2
PU-5YAKD / PU-6YAKD
PE-6EAK2
Remote Controller
PAR-21MAA
Included
PE SERIES
Type Fixed - Speed
Indoor Unit PE-3EAK2 PE-4EAK PE-5EAK2 PE-6EAK2
Outdoor Unit PU-3VAKD PU-4V/YAKD2 PU-5YAKD PU-6YAKD
Refrigerant R22
Source Indoor / Outdoor Separate Power Supply
Power
Supply V / Phase / Hz 230 / Single / 50 230 / Single / 50; 400 / Three / 50 400 / Three / 50
400 /Three / 50
Capacity Rated kW 7,3 9,8 12,1 14
Cooling Total Input Rated kW 3,33 (V) 3,77/ (Y) 3,70 4,94 5,93
EER 2,19 2,60/2,65 2,45 2,36
Dimensions
HxWxD mm 200 x 1190 x 700 428 x 1055 x 690 400 x 1180 x 634 400 x 1180 x 634
(Panel)
Indoor Weight (Panel) kg 27 58 56 56
Unit Air Volume m3/min 12-21 27-34 40-50 40-50
External Static Pressure Pa 50 63,5 100 100
Sound Level dB(A) 32-42 54-58 45-49 45-49
Dimensions HxWxD mm 850 x 840 x 330 1258 x 870 x 295 1258 x 970 x 345 1258 x 970 x 345
Outdoor Weight kg 69 83 111 112
Unit Air Volume Cooling m3/min 49 95 100 100
Sound Level Cooling dB(A) 53 54 55 56
Diameter Liquid/Gas mm 9,52/15,88 9,52/19,05 9,52/19,05 9,52/19,05
Ext.
Max. Length Out-In m 30 40 50 50
Piping
Max. Height Out-In m 15 30 50 50
Guaranteed Operating
Cooling C +21 +52 +21 +46 +21 +46 +21 +46
Range (Outdoor)
21
Centro Direzionale Colleoni
Viale Colleoni, 7 - Palazzo Sirio
20864 Agrate Brianza (MB)
tel. 039.60531 - fax 039.6053211
e-mail: clima@it.mee.com
NOTICE
Do not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate compounds and formaldehyde is known
to be high as this may result in a chemical reaction.
Our air-conditioning equipments and heat pumps contain flourinated greenhouse gasses R410A; R22.
When installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A or R22) to charge the refrigerant lines.
Do not mix it with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result in an explosion and other hazards.
The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit breakdown. In the worst case, this
could lead to a serious impediment to securing product safety.
14356