A. Composite Slab
D. Composite column
B. Shear Connectors
a result of stiffness and/or mass eccentricity The structures considered here is a commercial complex
in the structure. Asymmetry may in fact exist building having G+9 storey model located in seismic zone
in a nominally symmetric structure because III. The plan dimension of the building is 32m X 30m.
of uncertainty in the evaluation of center of mass
and stiffness, inaccuracy in the measurement of
the dimensions of structural
Depth of foundation 3m 3m
Importance factor 1 1 70
60 res comp
Response reduction
5 5
Displacement in mm
factor 50
eqx comp
Zone factor 0.16 0.16 40
30
Damping ratio 5% 2% res rcc
20
Floor finish 1.0 kN/m2 1.0 kN/m2 10 eqx rcc
Live load at all 0
4.0 kN/m2 4.0 kN/m2
floors
90 6.3 Self-Weight
Displacement in mm
80
70
60
50 Table -5: Self Weight (in kN) For RCC and Composite
40 resy comp
Models
30 eqy comp
20 Type of Structure Self-weight (KN)
resy rcc
10
eqy rcc R.C.C. 74411.97
0
Composite 61764.702
storey
80000
70000
Fig -9: Displacements in Y direction 60000
Weight in kN
50000
40000
6.2 Base Shear 30000 Self-weight (KN)
20000
Table -4: Base shear in kN 10000
0
Type of structure Base shear (KN)
R.C.C. Composite
R.C.C. 1768.977
Type of structure
composite 1521.7031
1400 Table -6: Axial force (in kN) for corner column
1350
Base shear Axial force of corner columns in kN
(KN) RCC 645.16
COMPOSITE 351.17
Fig -10, Base shear
REFERENCES
Table 6 and Figure 12 represent axial force for the corner
columns of the structures. The axial force of Composite [1] D. R. Panchal, P. M. Marathe, Comparative study of
Structures is reduced by 45%. R.C.C., Steel and Composite building, Institute Of
Technology, Nirma University, Ahmedabad-382481,
6.5 Torsion
December, 2011, pp. 08-10.
Maximum torsion for corner columns kN-m
[2] Mahesh Suresh Kumawat And L.G.Kalurkar (May
RCC 3.521 2014) Analysis And Design Of Multistory Building
COMPOSITE 4.473 Using Composite Structure International Journal Of
Structural And Civil Engineering Research Vol. 3, No. 2
Maximum torsion for RCC building is found to 3.521
pp 126-137.
KN-m and for steel building it is found to be 4.473
[3] Pardeshi sameer And. N.G.Gore (Jan 2016) Study of
KN-m
seismic analysis and design of multi storey symmetrical
and asymmetrical building International Research
7. CONCLUSION Journal of Engineering and Technology Vol. 03
1. The plan configurations of structure has significant [4] IS 456:2000, Indian Standard code of practice for
impact on the seismic response of structure in terms of Plain and Reinforced concrete, Bureau of Indian
displacement, story drift, story shear Standards, New Delhi, India.
2. The displacement (deflection) and storey drift in R.C.C. [5] IS 11384:1985, Code of Practice for Design of
Structure is merely less than composite structure but are Composite Structure, Bureau of Indian Standards, New
in permissible limit as prescribed by the codal pro- Delhi, India.
visions. It is due to the flexibility of composite structure
[6] IS: 11384, Code of practice for composite
when compared to RCC structures
construction in structural steel and concrete, Bureau of
3. Large displacement was observed in the T shape Indian Standards, New Delhi, 1985.
building. It indicates that building with severe irregularity
shows maximum displacement and storey drift