SCOPE




This equipment is mainly used for cavity of sanitary and water purifier products
air-tightness test, which takes the form of a smart air-tightness test to judge the quality of
the product, test parameters can be easily read. The device test can avoid wrong analysis of
visual observation of test with water.

INSTALLMENT
1 220V 50Hz
Power supply is 220V 50Hz, equipment must be securely grounded!
2 0.70.05Mpa
There must be clean (0.7 0.05) Mpa gas supply source through the air filter
after treatment.

MACHINE OPERATION AND


PARAMETER USAGE
1
Check the power supply, see if connect perfectly
2 1(0.750.05)Mpa 1
(0.60.01)Mpa,
Check the filter regulator (Figure 1) total pressure (recommended transferred (0.7
0.05) Mpa; check the test pressure gauge (Fig. 1) (recommended hyperbaric transferred
(0.6 0.01) Mpa.)

filter regulator test pressure gauge


3 1

2 19

Press the touch screen power button (Figure 1), click (green) button, enter the device
information interface, click on any part of the equipment information interface, with the
following main menu interface:

3 19
4


Put the product which need test with clamp to the fixture base, click manual adjust into
adjust fixture interface, and then click "next page" into another page; this interface main
function is testing the new fixture seal in order to make modify to the leak part on the
fixture. You also can test the clamp or fixture in water in the water tank.


:
1#
Working position 1 clamp adjust
Click: pressure downclampingair inletair outletreset (after click, light
turn from red to green), after adjust, press 1#reset button


:
2#
Working position 2 clamp adjust
Click: pressure downclampingair inletair outletreset (after click, light
turn from red to green), after adjust, press 2#reset button


:
3#
Working position 3 clamp adjust
Click: pressure downclampingair inletair outletreset (after click, light
turn from red to green), after adjust, press 3#reset button


:
4#
Working position 4 clamp adjust

4 19
Click: pressure downclampingair inletair outletreset (after click, light
turn from red to green), after adjust, press 4#reset button


:
5#
Working position 5 clamp adjust
Click: pressure downclampingair inletair outletreset (after click, light
turn from red to green), after adjust, press 5#reset button


:
6#
Working position 6 clamp adjust
Click: pressure downclampingair inletair outletreset (after click, light
turn from red to green), after adjust, press 6#reset button

:
7#
Working position 7 clamp adjust
Click: pressure downclampingair inletair outletreset (after click, light
turn from red to green), after adjust, press 7#reset button


:
8#
Working position 8 clamp adjust
Click: pressure downclampingair inletair outletreset (after click, light
turn from red to green), after adjust, press 8#reset button

5 19
5

Click the button "main menu" to enter the main menu interface, and then click "count"
to enter the count information interface. As follows:

6 19
6

Click the button "main menu" to enter the main menu interface, then click "parameter
settings" to enter the parameter settings interface. As follows:

7 19
name
ITCITC888

password


password input


Enter interface

Enter parameter
set interface after
password input

8 19

Slow up button

Fast up button

Fast down button

Slow down button

Parameter
Parameter save as
password
delete button Parameter save

Parameter
download

Parameter delete

9 19
7 12345678

After set above parameters 1, 2, 3, 4, 5, 6, 7, 8, click the button of parameter


save, and then click the transfer parameter download button, and then click
the test button to enter the test interface.

Pressure Clamp Second


down choose clamp
choose button choose
button button
10 19
a
bc
Note: before press the test button, you should select the action of the sealing fixture on the
automatic test screen to test. Such as: A, select pressure down; B, select pressure down, clamp on;
C, select pressure down, second clamp on.

8

Enter the testing interface, one hand press the start test button, test machine will according to the
setting of the parameters test. After the test, the test result will show "qualified "and" unqualified ",
and show all parts of which leakage alarm display.

9
1

After testing a product, and then test the next product, the product should be well placed and then
press the "test start button" (Figure 1) to test. Please turn off the gas supply and power supply
when not testing. If machine not used for a long time, the air pressure should be complete release
on the equipment.

PARAMETER SET AND MODIFY

1

Click on the button "main menu" to enter the main menu interface, and then click "parameter
settings" to enter the parameter settings:

11 19
Enter parameter
set interface after
password input

Slow up button

Fast up button

Fast down button

Slow down button

12 19
Parameter
Parameter save as
password
delete button Parameter save

Parameter
download

Parameter delete

2
Click on the above parameters so you can set and changed parameters

All parameters set


area

3 12345678

After set above parameters 1, 2, 3, 4, 5, 6, 7, 8, click the button of parameter save, and then click
the transfer parameter download button, and then click the test button to enter the test interface.

13 19



Pressure Clamp Second


down choose clamp
choose button choose
button button

a
bc
Note: before press the test button, you should select the action of the sealing fixture on the
automatic test screen to test. Such as: A, select pressure down; B, select pressure down, clamp on;
C, select pressure down, second clamp on.

14 19
4

Enter the testing interface, one hand press the start test button, test machine will according to the
setting of the parameters test. After the test, the test result will show "qualified "and" unqualified ",
and show all parts of which leakage alarm display.

5
1
After testing a product, and then test the next product, the product should be well placed and then
press the "test start button" (Figure 1) to test. Please turn off the gas supply and power supply
when not testing. If machine not used for a long time, the air pressure should be complete release
on the equipment.

REMARK AND MAINTENANCE


110%
the working voltage range allowed for the rated should be voltage of 10%.
2
must be grounded.
3
avoid dust and copper scrap go into the test holes, test holes need be prevented
4
the air source access into device for test must be filtered clean air (no oil, water, small
particles and other impurities).
5
The vacuum filter on the air path needs to check once each quarter year, replaced
accordingly.
6
After every day work, equipment should be made relief and release the gas inside the
remnants of compressed air.

TOUBLESHOOTING

REASON SOLUTION
CODE TROUBLE
Rubber pad damage Replace rubber pad

Connector loose take off pipe and cut one part and
connect again
AIR Connector damaged Change connector
1
LEAKAGE product not placed place it again
well before test
0.70.05Mpa
Low inlet air pressure Make sure air pressure 0.7
0.05Mpa
2 change filter

15 19
AIR Copper dust enter the air pipe
STOCK blocked filter
Parameter mixed restart machine
CAN NOT
3 change a new start
POWER Start bottom broken
button
ON

GARANTEE
1

2

1, when user uses this machine according to the requirements of this specification, if the
machine has any damage within one year because of quality problem, the company will
provide free repair service according to the invoice.
2, for the damage caused not meet the requirements of the manual are not the scope of the
warranty.

ACCESSORIES OF DIAGRAM, PARAMETER


AND REMARK
1-8# working position
parameter set1-8 EXW PARAMETER
1#
1 3000
Minimum operate pressurembar

2 1# cavity leak valuembar 50

3 1# cavity compensatormbar 0

4 1#T clamping time*S 2

5 1#T press down time*S 2

6 1# cavity air inlet time*S 15

7 1# cavity test time*S 5

8 1# cavity air keep time*S 10

16 19
9 1# air outlet time*S 5

10 1# alarm time*S 10

11 1# total time*S 200

other working position the same

REMARK
1# 2#
3#
4# 5#
6#
7#
8#
1 10-500mbar
2 10-500mbar

1500mbar

0.33cm3/s10S

.5S

10S

3S

1# station, 2# station, 3# station, 4# station, 5# station, 6# station, 7#


station, 8# station":
Setting of the maximum leakage pressure difference 1 of the cavity: usually
the pressure difference can be bettween 10-500mbar. According to your own
standards
Setting of the maximum leakage pressure difference 2 of the cavity: usually
the pressure difference can be bettween 10-500mbar. According to your own
standards
The "minimum operate pressure" means that the air pressure cannot be less than
1500mbar. Otherwise, the testing machine does not work or show serious leakage
or low working pressure.
"air inlet time": the larger valve body will be, the more time it need for
air inlet. On the contrary, the smaller valve body will be, the less time it
need for air inlet. In short, to make the cavity filled with air. The

17 19
calculation method of the air inlet time of the cavity can be determined
according to the size of the air inlet of the cavity: 0.33cm3/s. Generally,
cavity air inlet time are more than 10S.
4. The test time refers to the time for pressure sensor get a value.
Generally it is more than 5S time.
air keep time" is refers to the time when it have finish air inlet and holding
pressure inside, if the cavity have leak, the pressure sensor test pressure
value will be smaller than the air inlet pressure value (larger than the set
pressure difference value). The longer air keep, the higher test precession
will be. Generally at least more than or equal to 10S.
The "air outlet time" refers to the time of air outlet after test. usually
more than or equal to 3S.