RNC4> get uemeas timeToTrigger1b

170324-14:15:55 192.168.41.58 17.0d RNC_NODE_MODEL_V_7_1691 stopfile=/tmp/14475


================================================================================
=================================
MO Attribute Value
================================================================================
=================================
UeMeasControl=1 timeToTrigger1b 14
================================================================================
=================================
Total: 1 MOs

RNC4> mom . timeToTrigger1b


170324-14:16:14 192.168.41.58 17.0d RNC_NODE_MODEL_V_7_1691 stopfile=/tmp/14475
################################################################################
####################################################
MO Class Attribute Type
Flags
################################################################################
####################################################
ExternalUtranCell timeToTrigger1b long
--------------------------------------------------------------------------------
----------------------------------------------------
Time between detection of event 1b and sending of the measurement report.
Used by UE functions for intra-frequency measurement reporting in CELL_DCH.
-1 means that cell-level configuration for this cell is disabled.
Value mapping:
-1: UeMeasControl::timeToTrigger1b and UeMeasControl::reportingRange1b is used
0 : 0 ms
1 : 10 ms
2 : 20 ms
3 : 40 ms
4 : 60 ms
5 : 80 ms
6 : 100 ms
7 : 120 ms
8 : 160 ms
9 : 200 ms
10 : 240 ms
11 : 320 ms
12 : 640 ms
13 : 1280 ms
14 : 2560 ms
15 : 5000 ms
Dependencies: Used if the feature SoftHoCellConfig is active and the value is >=
0. Otherwise UeMeasControl::timeToTrigger1b in the SRNC is used.
Feature: SoftHoCellConfig
Change takes effect: Ongoing connections (next reconfiguration where a Measureme
nt Control message for Soft/Softer Handover purpose is sent)
Range: -1 to 15, Default=-1
********************************************************************************
****************************************************
RemoteUtranCell timeToTrigger1b long
--------------------------------------------------------------------------------
----------------------------------------------------
Time between detection of event 1b and sending of the measurement report.
Used by UE functions for intra-frequency measurement reporting in CELL_DCH.
-1 means that cell-level configuration for this cell is disabled.
Value mapping:
-1: UeMeasControl::timeToTrigger1b and UeMeasControl::reportingRange1b is used
0 : 0 ms
1 : 10 ms
2 : 20 ms
3 : 40 ms
4 : 60 ms
5 : 80 ms
6 : 100 ms
7 : 120 ms
8 : 160 ms
9 : 200 ms
10 : 240 ms
11 : 320 ms
12 : 640 ms
13 : 1280 ms
14 : 2560 ms
15 : 5000 ms
Dependencies: Used if the feature SoftHoCellConfig is active and the value is >=
0. Otherwise UeMeasControl::timeToTrigger1b in the SRNC is used.
Feature: SoftHoCellConfig
Change takes effect: Ongoing connections (next reconfiguration where a Measureme
nt Control message for Soft/Softer Handover purpose is sent)
Range: -1 to 15, Default=-1
********************************************************************************
****************************************************
UeMeasControl timeToTrigger1b long
--------------------------------------------------------------------------------
----------------------------------------------------
Time between detection of event 1b and sending of the measurement report.
Used by UE functions for intra-frequency measurement reporting in CELL_DCH.
Value mapping:
0 : 0 ms
1 : 10 ms
2 : 20 ms
3 : 40 ms
4 : 60 ms
5 : 80 ms
6 : 100 ms
7 : 120 ms
8 : 160 ms
9 : 200 ms
10 : 240 ms
11 : 320 ms
12 : 640 ms
13 : 1280 ms
14 : 2560 ms
15 : 5000 ms
Change takes effect: Ongoing connections (next switch to CELL_DCH)
Range: 0 to 15, Default=12
********************************************************************************
****************************************************
UtranCell timeToTrigger1b long
--------------------------------------------------------------------------------
----------------------------------------------------
Time between detection of event 1b and sending of the measurement report.
Used by UE functions for intra-frequency measurement reporting in CELL_DCH. -1 m
eans that cell-level configuration for this cell is disabled.
Value mapping:
-1: UeMeasControl::timeToTrigger1b and UeMeasControl::reportingRange1b is used
0 : 0 ms
1 : 10 ms
2 : 20 ms
3 : 40 ms
4 : 60 ms
5 : 80 ms
6 : 100 ms
7 : 120 ms
8 : 160 ms
9 : 200 ms
10 : 240 ms
11 : 320 ms
12 : 640 ms
13 : 1280 ms
14 : 2560 ms
15 : 5000 ms
Dependencies: Used if the feature SoftHoCellConfig is active and the value >= 0.
Otherwise UeMeasControl::timeToTrigger1b is used.
Feature: SoftHoCellConfig
Change takes effect: Ongoing connections (next reconfiguration where a Measureme
nt Control message for Soft/Softer Handover purpose is sent) . For cells that ar
e existing in the AS when the change is done, the old value will be used at Acti
ve Set update
Range: -1 to 15, Default=-1
********************************************************************************
****************************************************
Total: 4 MOs, 4 attributes

RNC4> get . maxactive


170324-14:16:26 192.168.41.58 17.0d RNC_NODE_MODEL_V_7_1691 stopfile=/tmp/14475
================================================================================
=================================
MO Attribute Value
================================================================================
=================================
Handover=1 maxActiveSet 4
================================================================================
=================================
Total: 1 MOs