Professional Documents
Culture Documents
Basics
Joe Peebles
Sales Director
Welcome to Emerson Network Power!
Introductions
Registration
Agenda
Tour of the facility
Emerson
Confidenti
al2
Power Plant
Safety
General Safety Precautions
Training and awareness is of utmost
importance.
Precautions
Be aware of emergency exits and escape routes
Create and follow an MOP or DMOP
Keep a list of important telephone numbers
Notify appropriate office personnel before beginning work
in a Power Plant environment
Be able to locate the following: AC/DC Power Breakers,
First Aid Kit, Eye Wash Kit, Acid Clean Up Kit, Fire
Extinguisher and MSDS
Emerson
Confidenti
al4
First Aid
Emerson
Confidenti
al5
Personal Protection Equipment (PPE)
FACT:
When Personal
Protective Equipment
is worn, the chances
of eliminating a
disabling injury are
Emerson
Confidenti
al6
much greater!
Application
Engineering
Telecommunications Central Office
Westlake
Telephone
Training
Emerson
Confidenti
al8
DC Power Overview
Typical Central Office Power Plant (-48V)
COMMERCIAL
AC POWER
AC AC
INVERTER LOAD
DC
BATTERY TERM. BAR DC DC
LOAD
MAIN
HOUSE
CONVERTER
SERVICE
PANEL BATTERY DIST.
_ _
_ FUSE BOARD
BATTERY
BATTERY
TRANSFER MAIN POWER LOW
SWITCH SHUNT BOARD
24 24 VOLTAGE
AC
CELLS CELLS DISCONNECT
MCA
PCU PCU
PCU PCU
PCU PCU
PCU PCU
LOAD
#2
#1
#3
#4
AC Input to PCUs 1 - 4 + +
#6
#5
#7
#8
POWER
DIST. DISCHARGE/RETURN BAR
SERVICE +
AC Input to PCUs 5 - 8
PANEL
BATTERY TERM. BAR LOAD RETURN BAR
GROUND
WINDOW
ALTERNATIVE
GENERATOR SHUNT POSITION
CENTRAL OFFICE
GROUND BAR
Emerson
Figure 1, Typical Central Office Power Plant (-48V)
Confidenti
al9
Central Office Power Plant
Rectifiers
Batteries
Inverters
Converters
Power Boards
Emerson
Confidenti
10
al
Rectifier Considerations
AC Power Cost
Alarms Floor weight
Selecting the size, or Future growth
amperage rating,
needed Redundancy
Load Recharge Current
Type of technology Maintenance
Controls Space
Emerson
Confidenti
11
al
Battery Considerations
Battery capacity and aging
Cost
Floor Loading
Generator Availability
Distance from batteries to plant equipment
Life expectancy
Load
Maintenance
Required Voltage
Reserve time to Minimum Volts Per Cell (MVPC)
Environment, Space & Ventilation
Emerson
Confidenti
12
al
Inverter Considerations
Cost
Environment, Location & Space
Floor loading
Frequency
Future growth
Input voltage of AC and DC
Load & Output voltage
Transfer type
Emerson
Confidenti
13
al
Converter Considerations
Cost
Distribution
Environment & Space
Future Growth
Input and Output Fusing
Input and Output Voltage
Load
Emerson
Confidenti
14
al
Power Board Considerations
Cost
Controls
Distribution
Floor loading
Future growth
Monitoring
Ventilation
Voltages
Emerson
Confidenti
15
al
DC Power Overview
Central Office Application Engineering Drawing
+
+ MAIN
POWER DC
BATTERY BOARD _ LOAD
_
MCA
BTB MTB
AC
PDSC
AC DC
AC
INVERTER
AC LOAD
D
C
+
DC
CONVERTER DC LOAD
_
NOTE: THE ACTUAL NUMBER OF PCUs
MUST BE DETERMINED FOR THE POWER PLANT
Figure 2
Emerson
Confidenti
16
al
DC Power
Leading global manufacturer of -48V and +24V network power systems
Modular system architecture facilitates optimal investments
Low installation and commissioning cost with pre-assembled
and pre-tested units
NetSure solutions provide a DC power technology platform of indoor and
outdoor integrated systems
Industry-leading reliability with over 2M units deployed
Near 97% efficiency with eSure rectifiers
Products
10-120A
NetSure 211NNFB
19 or 23 inch mounting
Voltage: -48V
NetSure 211NMFB
Capacity: 3000W (or 60A @ -48Vdc)
19 or 23 inch mounting
1RU Tall
Voltage: -48V
Capacity: 4800W (or 100A @ -48Vdc)
2RU Tall
NetSure 211 2RU Solution
19 or 23 solutions
NetSure 211 - General Features
2.0KW (40A) or 3.0KW (60A) / -48V system
2 front access battery connectors
Front access load connection
500W or 1000W plug-in rectifiers (10A or 20A)
SCU+ Controller e/w Ethernet
Easily accessible, plug-in design
High power density (60A system in 1.75 H)
Wide AC input range (single phase)
UL & NEBS Level 3
EMI/EMC FCC Class B
NetSure 211 - Distribution
Supports up to (10) GMT Fuse postions
Fuse sizes available from 0.18A to 15A
60A max DC Output rating
Designed for front access load cabling with tie-
down support.
Available with no-LVD or Battery Side Disconnect
(BLVD)
Accepts DC Load cables from 20AWG to 12AWG
NetSure 211 - Modular rectifiers
R48-500, R48-1000
DC output: 500W (10A) or1000W (20A)
1R482000
NetSure 502 External Distribution
Panel
-48VDC Power System - 582136800
400A DC Output
(1) to (3) Rectifier Shelves (third shelf field expandable)
19 & 23 Rack Mounting
Rear AC Access
Wide AC input range (single phase)
M521B controller & connector board
4 RU Height
Safety - UL 1801
NEBS Level 3 - pending
NetSure 502 External Distribution
Panel
-48VDC Power System - 582136800
Up to (24) Load Breakers/Fuses (1-250A) 23
Up to (18) Load Breakers/Fuses (1-250A) 19
Up to (18) Load and (6) Battery Breakers/Fuses positions(1-250A) 23
Up to (14) Load and (4) Battery Breakers/Fuses positions (1-250A) 19
GMT Load Fuse Option
4 RU Panel Height
Available with BLVD, LLVD, no-LVD
20 position GMT panel coming
NetSure 502 Top Bulk Distribution
-48VDC Power System - 582136800
Up to 400A of -48VDC power
(1) to (2) Rectifier Shelves
19 & 23 Rack Mounting
Top Rear AC Access Options
Top DC output 1 C-C, 3/8 hard.
Wide AC input range (single phase)
M521B controller & connector board
Safety UL 1801