Owner: ACWA Agent: SEPCO-III Calculation Nr.: MU-001 Date: 28/04/2017 Amiantit-Company: Amiantit Fiberglass Industries Ltd. DRAFT The software is a free tool, which may used by persons with technical knowledge concerning the pipe statics, soil mechanics and construction analysis. The software can not replace a structural e ngineer. The calculations are valid for products of the Amiantit Group only. All input fo r the calculation have to be proved by the user to ensure that the data equals the condtitions on the construction site. Th e results of the calculation can be reached only if it is proved that the input suits the real values. Calculations are base d on values given by the user; data and experiences are added if necessary. The results of this structural analysis may be reached in practice only if the assumptions meet the conditions found on the construction site. Appliance, fitti ng and real loading are out of reach of the software provider; these are the user's area of responsibility. The user is resp onsible for the stability of a building and the necessary material quantities. Ami-Tools V. 4.8.1.3 - 28/04/2017 21:43:38 1 SOHAR THERMAL POWERPLAN Content 1 Burried Pipe Design according AWWA M45 second edition: BURRIED PIPE 3 1.1 Input 3 1.2 Values from database 3 1.2.1 Installation conditions 3 1.2.2 Load Parameters 3 1.2.3 Advanced deflection options 3 1.3 Results 4 1.3.1 Confirmation of pressure class 4 1.3.2 Checking working pressure 4 1.3.3 Checking surge pressure 4 1.3.4 Calculation of deflection at allowable long-term strain 5 1.3.5 Calculation of soil load 5 1.3.6 Calculation of live loads 5 1.3.7 Calculation of the composite constrained soil modulus 5 1.3.8 Calculation of the predicted deflection 6 DRAFT 1.3.8.1 At minimum cover depth 6 1.3.8.2 At maximum cover depth 6 1.3.9 Checking combined loading 6 1.3.9.1 At minimum cover depth 6 1.3.9.2 At maximum cover depth 6 1.3.10 Checking buckling 7 1.3.10.1 At minimum cover depth 7 1.3.10.2 At maximum cover depth 7 1.3.10.3 At minimum cover depth 7 1.3.10.4 At maximum cover depth 7 Ami-Tools V. 4.8.1.3 - 28/04/2017 21:43:38 2 SOHAR THERMAL POWERPLAN 1 Burried Pipe Design according AWWA M45 second edition: BURRIED PIPE 1.1 Input Caption: BURRIED PIPE Assumptions: AWWA M45 Conclusion: none Include sketch in output: Yes Pipe from database: Yes Selected pipe: PN16 SN5000 DN1000 Type of glassfibre pipe: Pressure Series (FP 2.1) Pipe is pressure pipe: Yes Nominal pressure: PN 16 [bar] Nominal stiffness: SN 5000 [N/m] Nominal diameter: DN 1000 [mm] 1.2 Values from database DRAFT Outer diameter: OD 1,025 mm Nominal reinforced wall thickness (ASTM D3567): t 12.3 mm Thickness of the liner: t L 1.0 mm Total wall thickness: t t 13.3 mm Hoop tensile modulus of elasticity: E H 21,248.6 N/mm Hydrostatic design basis: HDB 0.65 % Ring-bending strain, long term: SB 1.30 % 1.2.1 Installation conditions Maximum cover depth: H max 3.0 m Minimum cover depth: H min 1.2 m Groundwater: Yes Depth to water table: H max 1.0 m Depth to water table: H Wmin 0.5 m Trench width: B d 2.0 m Soil stiffness category (Table 6-1): SC1: Crushed rock, < 15% sand, < 5% fines Type of filling (Table 5-4): Compacted Backfill unit weight: 18.8 kN/m Specific weight below water: 11.5 kN/m Material and Compaction (Table 5-1): Sand; compaction: moderate to high Native soil type (Table 5-6): Granular Native soil (granular): Very, very loose (0 - 1 blows/ft) Bedding coefficient: Inconsistent haunch achievement (Kx = 1.2.2 Load Parameters Working pressure: P w 0,1) 2.40 bar Surge pressure: P s 3.20 bar Vacuum pressure: P v 1.00 bar Traffic load: HS 20 Truck load 1.2.3 Advanced deflection options Standard deflection coeffizient / lag factor: Yes Standard permitted deflection (5%): Yes Ami-Tools V. 4.8.1.3 - 28/04/2017 21:43:38 3 SOHAR THERMAL POWERPLAN 1.3 Results Traffic load: HS 20 Truck load Mean pipe diameter: D 1,012.67 mm D =OD - t 1.3.1 Confirmation of pressure class P c < HDB FS
2 t E H D (5-2) Pressure class: P c 16.00 bar Value for (HDB/FS)(2t EH / D): P c,max 18.69 bar The pressure class of the pipe is smaller than (HDB/FS)(2tEH/D). 1.3.2 Checking working pressure P c =P (5-3) Working pressure: P w w 2.40 bar Pressure class: P c 16.00 bar The working pressure is lower than pressure class of the pipe. 1.3.3 Checking surge pressure P c = P w + P s DRAFT 1.4 (5-4) Working pressure: P w 2.40 bar Surge pressure: P s 3.20 bar Pressure class: P c 16.00 bar Working pressure + surge pressure is lower than 1.4 times pressure class of the pipe. Ami-Tools V. 4.8.1.3 - 28/04/2017 21:43:38 4 SOHAR THERMAL POWERPLAN 1.3.4 Calculation of deflection at allowable long-term strain ?y t t a = S b D FS D =t + t L f 2 t t Shape factor: D f 5.5 [-] Maximum allowable Iong-term vertical pipe deflection (absolute): ?y a 121.22 mm Maximum allowable Iong-term vertical pipe deflection (relative): ?y a /D 11.97 % Maximum permitted long-term installed deflection: dd/D 5.00 % The maximum permitted long-term installed deflection is smaller than the maximum allowable Iong-term deflection. 1.3.5 Calculation of soil load W c =? s H (5-9) at minmum depth at maximum depth Cover height H 1.20 3.00 m Vertical soil load on the pipe W c 22.56 56.40 kN/m Vertical soil load on the pipe, considering buoyancy W c ' 17.45 41.80 kN/m 1.3.6 Calculation of live loads Traffic load: HS 20 Truck load at minmum depth at maximum depth I =1 + 0.33 [(2.44 m - h)/2.44 m] = 1 (5-11) Impact factor I f f 1.17 1.00 [-] Factor to account for live load distribution with depth of fill LLDF 1.15 1.15 [ -] Length of tire footprint t l 254 254 mm L 1 =t + LLDF H (5-12) Load width parallel to direction of travel L 1 l 1.63 3.70 m Width of tire footprint t w h int = (1.83 m - t ) LLDF w Depth at which load from wheels interacts h int L L 2 2 =t = t w w + LLDF H H = h + 1.83 m + LLDF H 2 int H > h int Load with perpendicular to direction of travel L 2 508 508 mm 1.1 1.1 m 1.86 2.89 m Wheelload at surface P 71.3 71.3 kN W L = 1.2 P I L 1 L 2 f Traffic load on surface W L 32.89 7.98 kN/m 1.3.7 Calculation of the composite constrained soil modulus M s =S c M sb DRAFT (5-19) at minmum depth at maximum depth Additional factor for the soil modulus due to vertical stress (note 7, table 5-4) f w 1.00 1.00 [-] Ami-Tools V. 4.8.1.3 - 28/04/2017 21:43:38 5 SOHAR THERMAL POWERPLAN (5-6) (5-15) (5-13) (5-14) (5-10) Constrained soil modulus of the pipe zone embedment M sb 19.11 24.90 N/mm Constrained soil modulus of the native soil at pipe elevation M sn 0.34 0.34 N/mm Soil support combining factor S c 0.18 0.16 [-] Composite constrained soil modulus M s 3.46 4.00 N/mm 1.3.8 Calculation of the predicted deflection ?y D = (D L W c + W L ) K 0.149 PS + 0.061 M x s Bedding coefficient K x at minmum depth 0.100 0.100 [-] Deflection lag factor D L 1.500 1.500 [-] Predicted vertical pipe deflection ?y/D 2.7 3.3 % Maximum permitted long-term installed deflection dd/D 5.00 5.00 % 1.3.8.1 At minimum cover depth The predicted deflection is lower than the permitted deflection. 1.3.8.2 At maximum cover depth The predicted deflection is lower than the permitted deflection. 1.3.9 Checking combined loading e pr HDB = e b r S b c 1 e = 1 - b r S FS b pr e pr HDB FS b c Pressure design factor FS pr at minmum depth 1.80 1.80 [-] Bending design factor FS b 1.50 1.50 [-] Rerounding coefficient r c 0.92 0.92 [-] Working strain due to internal pressure e pr 0.05 0.05 % Working strain due to maximum permitted deflection e b 0.36 0.36 % ?pr / HDB 0.07 0.07 [-] [1 - ((eb rc) / Sb)] / FSpr 0.41 0.41 [-] (eb rc) / Sb 0.26 0.26 [-] [1 - (epr / HDB)] / FSb 0.62 0.62 [-] 1.3.9.1 At minimum cover depth Combined loading (working strain due to internal pressure) is ok. Combined loading (working strain due to maximum permitted deflection) is ok. 1.3.9.2 At maximum cover depth DRAFT Combined loading (working strain due to internal pressure) is ok. Combined loading (working strain due to maximum permitted deflection) is ok. at maximum depth at maximum depth Ami-Tools V. 4.8.1.3 - 28/04/2017 21:43:38 6 SOHAR THERMAL POWERPLAN (5-8) (5-22) (5-23) 1.3.10 Checking buckling q a = 1 FS
1.2 C n ' 8 SN 0.33
(f s M s k ? ) 0.67 R h (5-24b) at minmum depth Design factor, buckling FS 2.50 2.50 [-] Scalar calibration factor to account for some nonlinear effects C n ' 0.55 0.55 [-] Factor to account for variability in stiffness of compacted soil f s ' 0.90 0.90 [-] Modulus correction factor for poisson's ratio of soil ? ? ' 0.74 0.74 [-] Correction factor for depth of fill R h ' 0.96 1.01 [-] Allowable buckling pressure q a (5-25) q v = ? w h w + R w W c + P v =q a Specific weight of water ? w at maximum depth 153.54 176.95 kN/m 9.80 9.80 kN/m Height of water surface above top of pipe h w 0.70 2.00 m Water buoyancy factor R W 0.81 0.78 [-] Buckling pressure, groundwater + soilload + vacuum q v 125.08 163.59 kN/m 1.3.10.1 At minimum cover depth The calculated buckling pressure due to groundwater, soil pressure and vacuum pr essure is lower than the allowable buckling pressure. 1.3.10.2 At maximum cover depth The calculated buckling pressure due to groundwater, soil pressure and vacuum pr essure is lower than the allowable buckling pressure. (5-26) q v = ? w h w + R w W c + W L =q a Buckling pressure, groundwater + soil + traffic q w 57.97 71.57 kN/m 1.3.10.3 At minimum cover depth The calculated buckling pressure due to groundwater, soil pressure and traffic l oads is lower than the allowable buckling pressure. 1.3.10.4 At maximum cover depth The calculated buckling pressure due to groundwater, soil pressure and traffic l oads is lower than the allowable buckling pressure. All necessary proofs are ok. DRAFT Ami-Tools V. 4.8.1.3 - 28/04/2017 21:43:38 7 SOHAR THERMAL POWERPLAN