You are on page 1of 14

Cooling water flowrate 11

Temperature of water in 25
Temperature of water out 35
Average temperature of water 30

Physical property data of water 30


Thermal conductivity 0.000616
Heat capacity 4.179
Viscosity 0.000803
Density 995

Temperature of syngas in 52
Temperature of syngas out 28
Average temperature of tube walls on water side 40

Shell inside diameter 0.584


Number of tubes 384

Tube arrangement staggered

Tube outside diameter 0.019


Tube cross sectional area 0.000283529

Percent clearance between tubes 33.00


Clearance between tubes 0.00627

Baffles 5
Baffle cut 25
Baffles spacing 0.15

Length of heat exchanger 3.66

Tube pitch 0.02527


Pitch ratio 1.33

Cross-flow area of water in shell 0.02174

Crossflow diameter of water in shell 0.023792435

Mass flowrate of water per area 506.0882801

Reynolds number 16631.31575

Prandtl number 4.856494382

Heat transfer coefficient 3424.119129

bo 0.594248381

f 0.138302177

Pressure drop 10195.59719


Unit Symbol
kg/s

C
C
C

35 40 C / 1bar
0.000623 0.000632 kJ/ (s m K)
4.179 4.179 kJ/ (kg K)
0.000724 0.000657 Pa s
995 995 kg/ m3

C
C
C

%
m

%
m

m2

kg/ (m2 s)

W/ (m2 K)

Pa 0.1019559719
Note

WORK OUT TEMPERATURE INSIDE TUBES THEN TEMPERATURE OF OUTSIDE OF WALLS

Guess/use previous iteration


Guess/use previous iteration

Same as triangular

(% of tube diameter)
Look at standard lengths in coulson and richardson

outside diameter of tube + tube spacing


tube pitch/tube outside diameter, minimum 1.25

bar
Constant

Constant
you can change
changes based on 'temperature of water in and water out'

find from tables


find from tables
find from tables
find from tables

Constant
Constant
Constant

you can change


you can change

you can change


changes based on 'percent clearance between tubes'

you can change


you can change
you can change

you can change


Physical property data of water
Thermal conductivity
Heat capacity
Viscosity
Density
22C / 6bar 23 24 25 26 27 28
HYSYS DATA

29 30 31 32 33 34 35

You might also like