CODEMASTER LED FACTORY SEALED LUMINAIRES

FEATURES Factory sealed. External seals not Typical applications include:


Fixture operates safely in high ambient required. Chemical
temperatures Lens, driver, and LED array are all field Oil, Gas, and Petrochemical
70 W equivalent: -40 C to +65 C replaceable. Pulp and Paper
(-40 F to +149 F) LED arrays generate light outputs from Foundries
100, 150, 400 W equivalent: -40 C to 2,300 to 12,850 lumens (an equivalent of Manufacturing
+55 C (-40 F to +131 F) 70 W HID to 400 W HID lamps) providing Waste and sewage treatment
175, 250, 350 W equivalent: -40 C to exceptional efficacy Pharmaceutical
+50 C (-40 F to +122 F) Universal, high efficiency, drivers cover Mining
60,000 hours rated life eliminates the voltage requirements for 120-277 Vac Power Generation
need for frequent relamping. and 347-480 Vac, 50/60 Hz, Volts +/-
Arrangement of heat-producing 10%. NEC/CEC RATINGS
components results in more efficient heat Standard surge suppression: Class I, Division 1 and 2, Groups B, C, D
dissipation for cooler fixture operation. 3KV for 347-480 Vac input Class I, Zone 1, Group IIB + H2
All threaded joints are flame-tight. 4KV for 120-277 Vac input Class II, Division 1, Group E, F, G
Aluminum body utilizes the same Class II, Division 2, Group F, G
CodeMaster HID mounting hoods, SUITABLE LOCATIONS Class III
and is an easy retrofit for existing Explosionproof fixtures suitable for use in: Simultaneous Exposure
CodeMaster HID installations; can A wide range of hazardous areas where Type 3R, 4X
be pendant, ceiling, wall, or stanchion ignitable vapors, dust, moisture and IP66/67
mounted. corrosive elements are present Suitable for Use in Wet Locations
Acme double-lead threads speed Areas where access to relamp is Marine Outside Type (Salt Water)
installation and fixture removal from difficult, reliability is essential, and
mounting hood only half as many environment is costly to maintain.
turns are required as for single-lead Consistent light levels maintained Use of a fuse voids Marine Outside Type (Salt
threads. The threads do not stick or gall, Water) rating.
regardless of cold temperatures
eliminating the troublesome problems Areas requiring frequent on-and-off of
often encountered with single lead lights or power cycling- no warm up
threads during fixture unit removal. time required
Safe, easy servicing without Type 4X, marine, wet locations and
disconnecting any wiring. Wireless hose-down environments
fixture unit easily threads off mounting Areas with high energy costs-
hood for convenient servicing or for CodeMaster LED consumes 50% less
immediate replacement with a stand- power than its HID equivalent
by unit.
Factory sealed. External seals not
required.

For product information:


www.appletonelec.com
1.800.621.1506
CODEMASTER LED FACTORY SEALED LUMINAIRES

STANDARD MATERIALS
Housing: copperfree (4/10 of 1% max.)
aluminum
Mounting hoods and bodies: cast copperfree
Efficient heat dissipation for optimum T rating and
(4/10 of 1% max.) aluminum safe operation in high and low ambient temperatures
All hardware and catch assemblies: stainless
steel
Gaskets: silicone
Globe: explosionproof glass Field replaceable array, delivering up to 110 lumens
per Watt, easily accessed with removal of the
threaded globe assembly
STANDARD FINISHES
NEMA 4x cast copperfree aluminum body with baked
Mounting hoods, bodies, and guards: baked epoxy powder coat finish for durability and corrosion
gray epoxy clad finish, electrostatically resistance
applied for complete uniform protection Choice of clear glass lens or diffused lens to reduce
glare in low ceiling applications
NEC/CEC CERTIFICATIONS AND COMPLIANCES
Optional lens guard to protect against breakage
UL Standard: UL 50, UL 50E, UL 844, UL 1598,
UL 1598A, UL 8750
CSA Standard: CAN/CSA-C22.2 No. 94.1-
07 (R2012), CAN/CSA-C22.2 No. 94.2-07
(R2012), CAN/CSA-C22.2 No. 137-M1981
(R2009), CAN/CSA-C22.2 No. 250.0-08
(R2013), CAN/CSA-C22.2 No. 250.13, CAN/
CSA-C22.2 No. 60529-05 (R2010)
ANSI Standard: ANSI/IEC 60529
cCSAus Certified: 70030675 Field replaceable driver to quickly
maintain your luminaire with
minimal downtime

Optional fuse to protect


circuits against power
quality problems

CMLED70 CMLED10 CMLED15 CMLED17 CMLED25 CMLED35 CMLED40


Equivalent to
70W 100W 150W 175W 250W 350W 400w
HPS/PSMH

Voltage BU: 120-277Vac, 50/60Hz BH: 347-480Vac, BU: 120-277Vac,


Range BH: 347-480Vac, 50/60Hz 50/60Hz 50/60Hz

LED Lumens 2582 3976 4838 6294 8982 11830 13732

Input Power 35/33 47.5/46 61/62 74/72 97/92


107/103 127/128
(W) 35/33 47.5/46 61/62 74/72 97/92
Efficacy 74 84 79 85 93 111 108
T-Rating T6 @ 55C T6 @ 50C T6 @ 55C

Ambient -40C to +65C -40C to +55C -40C to +55C -40C to +50C -40C to +50C -40C to +50C -40C to +55C
Temperature (-40F to +149F) (-40F to +131F) (-40F to +131F) (-40F to +122F) (-40F to +122F) (-40F to +122F) (-40F to +131F)
CCT/CRI 5650K/70
Fixture Weight 17 kg (38 lbs)
Standard
Baked gray epoxy clad finish, electrostatically applied for complete, uniform protection
Materials
Lifetime 60,000+ hours

United States: 1.800.621.1506 | Asia/Pacific: + 65.6891.7600 | Australia: + 61.3.9721.0348


Brazil: So Paulo/SP + 55.11.2122.5777 | Brazil: Camaari/BA + 55.71.3623.2028 | Canada: + 1.888.765.2226
China: + 86.21.3418.3888 | Europe: + 33.3.2254.1390 | Mexico/Latin America: + 52.55.5809.5049
Middle East/Africa/India: + 971.4.811.8100
www.appletonelec.com