You are on page 1of 3

For mezanee floor panel P-3, P-4, P-5 and P-6

It an exhibition area the live load is 5kn/m2


Dead load =5.63KN/m2 x 1.3 = 7.32 KN/m2
Live load =5KN/m2 x 1.6 = 8 KN/m2
Pd = 15.32KN/m2

In order to limit crack width at the top side hillerberge (1996) propose to adopt a
band width equal to minimum 1/10 to 1/5 of the length of the free edge.
= (6.52/10 + 6.52/5 )/2 =1m
Assumption use 1m strip width strong band , in the main slab portion k1=0.45
Slab load in short direction 0.45 x 15.32 = 6.89KN/m
Slab load in long direction 0.55 x 15.32 = 8.426KN/m
Mys in the short direction is 0.
2
1+

k 1 =strong band width/total length of lx , =1/5=0.2 , k1= 0.45
k 2=

K2= 0.32
Uplift in the strong band for y direction strip 0.36x15.32 = 5.52KN/m
Moment at support mys=29.86KNm
Moment at span mxf=19.85KNm
Myf = 14.93KNm
Moment at strong band mys 73.83KNm
Myf= 36.91 KNm