You are on page 1of 6

HIGH-PRESSURE

RELIEF VALVES
H-900HP SERIES

VALVES & ACTUATORS


FEATURES GENERAL
n H-900HP is available as CE/PED products H-900 HP is a series of relief valves for high-pressure service.
n 316St.St. Construction The valve is normally closed.
n Service up to 6000 psi It will open when the system pressure reaches the set level.
n Set Pressure from 50 psig to 6000 psig ( 3.50 to 414 bar) It will re-close when the system pressure falls below the set level.
n Identifying colored springs for each pressure range
1
n Replaceable springs for a variable pressure range
n Available in all pipe threads and LET-LOK connectors
n Sizes: 1/4" or 6mm

2
3
MATERIALS OF CONSTRUCTION
Item No. Components Qty. Valve Body Material
1 Cap Plug 1 PTFE
4
2 Label 1 Polyester
3 Adjustment Cap 1 St.St 316
4 Spring 1 St.St. 302,17-7PH
5 Lower Spring Button 1 St.St 316 5
6 Locking Nut 1 St.St 316
7 Bonnet 1 St.St 316
6
8 O-Ring 1 Fluorocarbon FKM
9 Quad Ring 1 Fluorocarbon FKM
10 Retaining Ring 1 PH15-7Mo
11 Poppet 1 St.St 316
12 Clamps Screw 1 St.St 316
13 O-Ring 1 Fluorocarbon FKM
7
14 Insert 1 St.St 316
15 Body 1 St.St 316

STANDARD CONFIGURATION DIMENSIONS 8


VALVES & ACTUATORS

Connection / size Dimensions 9


Description A B C D
inlet outlet 10
mm inch mm inch mm inch mm inch
H-900HP 1/4 LET-LOK
1/4 LET-LOK
37 1.45 39 1.53 50 1.97 96.0 3.78
H-900HP 6MM LET-LOK 6MM LET-LOK 37 1.45 39 1.53 50 1.97 96.0 3.78
H-985HP 1/4 Male NPT 1/4 Female NPT 32 1.26 30 1.18 40 1.57 88.6 3.49
11
H-995HP 1/4 Male NPT 1/4 LET-LOK 32 1.26 39 1.53 50 1.97 88.6 3.49

12

13

14

Lock Wire
Holes
15
D

B
C

294 HIGH-PRESSURE RELIEF VALVES H-900HP SERIES


CLEANING & PACKAGING TESTING
Every H-900HP series Relief valve is cleaned in accordance with The Ham-Let H-900HP Relief Valves design has been tested for
Standard Cleaning and Packaging (procedure 8184). Oxygen Proof and Burst.
Clean & Lubricant Free Cleaning and packaging, in accordance Every H-900HP Relief Valve is factory tested for proper set and
with Special Cleaning and Packaging (procedure 8185), is avail- resealing performance.
able as an option.

NOMINAL CRACKING PRESSURE RANGE


Spring
psig Bar Color
Designator
50-350 3.4 - 24 A White
350-750 24 - 51.5 B Blue
750-1500 51.5 - 103 C Gold
A B C D E F G H
1500-2250 103 - 155 D Turquoise
2250-3000 155 - 206 E Green
3000-4000 206 - 275 F Red
4000-5000 275 - 344 G Silver
5000-6000 344 - 413 H Black

PRESSURE TEMPERATURE RATING

Series H-900HP Size: 1/4"

Seal Meterial Fluorocarbon FKM Buna N Polychloroprene (CR) EPDM


TEMP
MAX SET PRESSURE psig (bar)
C (F)
-40 (-40)

VALVES & ACTUATORS


-
-34 (-30) -
-23 (-10) -
-
-18 (0)
-12 (10) 6000
6000 (413)
-4 (25)
(413)
6000
-1 (30) 6000
(413)
10 (50) (413)

65 (150) 5600 (386) 5600 (386) 5600 (386) 5600 (386)


93 (200) 5200 (358) 5200 (358) 5200 (358) 5200 (358)
121 (250) 4900 (338) 4900 (338) 4900 (338) 4900 (338)
135 (275)
- - 4700 (324) -
148 (300)

SETTING AND RESEALING PRESSURE


H-900HP RESEAL PRESSURE
n Upstream set pressure is the first indicator of flow process. Min Resealing Pressure
Every pressure relief after the first is repeatable within Test Set Pressure as a
a deviation of 5% at room temperature. Series
psig (bar) Percentage of set
n Blocked upstream set pressure is the first indicator of a stopped
pressure, %
flow process and is always lower than the set pressure. 100 - 200 (6.8 to 13.7) 50
H-900HP
850 - 1000 (58.5 to 68.9) 84

HAM-LET ADVANCED CONTROL TECHNOLOGY 295


FLOW DATA AT 70F (20C)
Orifice in fully open mode is 3.6mm (0.14 inch)

A B

SPRING 50-350psig SPRING 350-750psig

AIR FLOW WATER FLOW

Air Flow (SLPM) Water Flow (LPM)


0 500 1000 1500 2000 2500 0 1 2 3 4 5 6 7
1000 70 1000 70

si
800 700 p 55 800 700 psi 55
Inlet Pressure (Psig)

Inlet Pressure (bar)

Pressure Drop (Psi)

Pressure Drop (bar)


i
550 ps
600 600
550 psi
s i 41 41
400 p
400 psi
400 300 psi 27 400 300 psi 27

150 psi
200 14 200 150 psi 14
50 psi 50 psi
0 0
0 10 20 30 40 50 60 70 80 90 100 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2
Air Flow (SCFM) Water Flow (US.GPM)
VALVES & ACTUATORS

C D

SPRING 750-1500psig SPRING 1500-2250psig

AIR FLOW WATER FLOW

Air Flow (SLPM) Water Flow (LPM)


0 500 1000 1500 2000 2500 0 0.2 0.4 0.6 0.8 1.0
2400 165 2400 165

si
psi 2000 p
2000
Inlet Pressure (Psig)

Inlet Pressure (bar)

Pressure Drop (Psi)

Pressure Drop (bar)

2000 138 2000 138

psi 160 0 psi


1600
1600 110 110
1400 psi
1600 1400 psi

si
1200 83 1200 1000 p 83
1000 psi
i 800 psi
800 ps
800 55 800 55
0 10 20 30 40 50 60 70 80 90 100 0 0.04 0.08 0.12 0.16 0.2 0.24 0.28 0.32
Air Flow (SCFM) Water Flow (US.GPM)

296 HIGH-PRESSURE RELIEF VALVES H-900HP SERIES


FLOW DATA AT 70F (20C)
Orifice in fully open mode is 3.6mm (0.14 inch)

E F

SPRING 2250-3000psig SPRING 3000-4000psig

AIR FLOW WATER FLOW

Air Flow (SLPM) Water Flow (LPM)


0 1000 1500 2000 2500 0 0.2 0.4 0.6 0.8 1.0
500
4500 310 4500 310

psi psi
3800 3800
4000 275 4000 275
Inlet Pressure (Psig)

Inter Pressure (bar)

Pressure Drop (Psi)

Pressure Drop (bar)


psi
i 3200
3500 32 00 ps 240 3500 240
i
0 ps
280
psi
2800 i
3000 206 3000 0 ps 206
250
250 0 psi

2500 172 2500 172


0 10 20 30 40 50 60 70 80 90 100 0 0.04 0.08 0.12 0.16 0.2 0.24 0.28 0.32

Air Flow (SCFM) Water Flow (US.GPM)

VALVES & ACTUATORS


G H

SPRING 4000-5000psig SPRING 5000-6000psig

AIR FLOW WATER FLOW

Air Flow (SLPM) Water Flow (LPM)


0 100 200 300 400 500 0 0.2 0.4 0.6 0.8 1.0
6000 413
6200 427

550 0 psi i
5600 386 0 ps
5800 550 400
Inlet Pressure (Psig)

Pressure Drop (bar)


Inter Pressure (bar)

Pressure Drop (Psi)

5200 359 372


psi 5400 si
4800 0p
480
4800 330 5000 345

psi 0 ps
i
4400 4200 303 420
4600 317

4000 276 4200 290


0 2 4 6 8 10 12 14 16 18 20 0 0.04 0.08 0.12 0.16 0.2 0.24 0.28 0.32
Air Flow (SCFM) Water Flow (US.GPM)

HAM-LET ADVANCED CONTROL TECHNOLOGY 297


APPLICATIONS OPERATION
H-900HP relief valves gradually open when pressure increases. H-900HP relief valves open when system pressure gets to the set
As such, they are not certified to ASME due to not having pressure and close when system pressure drops below the set
capacity rating at a given pressure rise (accumulation). pressure.

Warning
n Valves that were not actuated for some time may contain
pressure higher than the set pressure.
n System designer and users shall determine what system
applications require using relief valves for meeting
specific safety codes and which valves conform to such codes.

H-900HP ORDERING INFORMATION

OPTIONAL

H-9 00 - HP - SS - L - 1/4 - A - - -

Valve Series Body Material End Connection Size Seal Material

SS - 316 St.St. 1/4 6MM BLANK - Fluorocarbon FKM


BU - Buna N

Valve Type End Connection Spring Designator EP - EPDM


NE - Polychloroprene (CR)
00 - LET-LOK Ends L - LET-LOK A, B, C, D, E, F, G, H
85 - Male to Female End N - NPT See table:
95 - Male to LET-LOK End R - ISO Tapered "NOMINAL CRACKING
PRESSURE RANGE" CE/PED Certification
NL - NPT to LET-LOK
For other end connections, BLANK - Standard testing
please contact HAM-LET
representative. CE - Certification PED
VALVES & ACTUATORS

Factory Calibration 97/23/EC


Designator
50-6000 Psi Treatment
Example: H-900-HP-SS-L-1/4-A120
Will be Calibrated to 120 Psi
BLANK - Standard Cleaning &
Passivation
OC - Oxygen Clean
ORDERING INFORMATION FOR SPARE KITS LF - Lubricant Free
SPRING KIT SEAL KIT
Includes: Includes: O-Rings and label
Spring (specific to desired set pressure range) and label.

Z - 900 - HP - SPK - 1/4 - A Z - 900 - HP - SK - 1/4 - VI

Body Designator Spring Designator Body Designator


Seal Material
per End Connection per End Connection

1/4 for all end connections A, B, C, D, E, F, G, H 1/4 for all end connections VI - Fluorocarbon FKM
See table above BU - Buna N
EP - EPDM

n For oxygen applications work shall be carried out according to procedures for
NE - Polychloroprene (CR)
working with oxygen. In case spare kits are ordered for oxygen clean valves, such
kits have to be ordered as oxygen clean by adding "-OC" designator.
Example: Z-900-HP-SK-1/4-VI-OC
Warning!
The system designer and user have the sole responsibility for selecting products suitable for their special
application requirements, ensuring their safe and trouble-free installation, operation, and maintenance. Ap-
plication details, material compatibility and product ratings should all be considered for each selected product.
Improper selection, installation or use of products can cause property damage or personal injury.

H-900HP, Rev.09, January 2014

298 HIGH-PRESSURE RELIEF VALVES H-900HP SERIES