A = Anode, C = Cathode
IXYS reserves the right to change limits, test conditions and dimensions
120 0.8 30
A TVJ= 100C TVJ= 100C
VR = 100V A V = 100V
C R
100 Qr 25
0.6 IRM
IF IF= 15A
80 20 IF= 35A
IF= 70A
IF= 15A
60 0.4 IF= 35A 15
TVJ=150C IF= 70A
40 TVJ=100C 10
TVJ= 25C 0.2
20 5
0 0.0 0
0.0 0.4 0.8 1.2 V 10 100 A/s 1000 0 200 400 600 A/s800 1000
VF -diF/dt -diF/dt
Fig. 1 Forward current IF versus VF Fig. 2 Typ. reverse recovery charge Fig. 3 Typ. peak reverse current IRM
Qr versus -diF/dt
versus -diF/dt D1
1.6 70 6 1.8
TVJ= 100C TVJ= 100C
ns
VR = 100V V tfr IF = 35A s
1.4 60 5 1.5
trr VFR VFR
Kf tfr
50
1.2 4 1.2
40
1.0 3 0.9
30
IF= 15A
0.8 IF= 35A 2 0.6
IRM 20
IF= 70A
0.6 10 1 0.3
Qr
0.4 0 0 0.0
0 40 80 120 C 160 0 200 400 600 A/s
800 1000 0 200 400 600 A/s
800
TVJ -diF/dt diF/dt
Fig. 4 Dynamic parameters Qr, IRM Fig. 5 Typ. recovery time trr Fig. 6 Typ. peak forward voltage
versus TVJ versus -diF/dt VFR and tfr versus diF/dt
1.2
Dimensions Dim. Millimeter Inches
K/W Min. Max. Min. Max.
1.0 A 19.81 20.32 0.780 0.800
B 20.80 21.46 0.819 0.845
C 15.75 16.26 0.610 0.640
0.8 D 3.55 3.65 0.140 0.144
ZthJC
E 4.32 5.49 0.170 0.216
0.6 F 5.4 6.2 0.212 0.244
G 1.65 2.13 0.065 0.084
H - 4.5 - 0.177
0.4
J 1.0 1.4 0.040 0.055
K 10.8 11.0 0.426 0.433
0.2 L 4.7 5.3 0.185 0.209
M 0.4 0.8 0.016 0.031
DSEK 60-02 N 2.2 2.54 0.087 0.102
0.0
0.001 0.01 0.1 1 s 10
t
Fig. 7 Transient thermal impedance junction to case
831
Authorized Distributor
IXYS:
DSEK60-02A DSEK60-02AR