Professional Documents
Culture Documents
Blue = Activated
1 UID switch and LED Flashing blue = Server being managed remotely
Off = Deactivated
Green = Normal (system on)
Flashing amber = System health is degraded
2 Internal system health LED
Flashing red = System health is critical
Off = Normal (system off)
Green = Normal (system on)
Flashing amber = System health is degraded
3 External system health LED
Flashing red = System health is critical
Off = Normal (system off)
4 NIC 1 link/activity LED Green = Linked to network
Flashing green = Linked with activity on the
network
Item Description Status
1 Fan X
2 Port 85 Codes
3 PCI X
4 SCSI BP
5 MEM
6 MEM BP
Item Description
7 FSB
8 PROC
9 OVER TEMP
10 No Boot
Common problems can be diagnosed by first looking at the external system health IDs and then by opening
the chassis and viewing the QuickFind Diagnostic Display. For troubleshooting, an amber LED will isolate
the failed or pre-failed component on any of the components represented on the Quick Find Panel shown
above.
The following table descibes possible failure conditions indicated by the amber light.
LED Description
LED
Item Status
Description
On = Drive activity
1 Activity status Flashing = High activity on the drive or drive is being configured as
part of an array
Off = No drive activity
On = Drive is part of an array and is currently working
2 Online status Flashing = Drive is actively online
Off = Drive is offline
LED
Item Status
Description
On = Drive failure
3 Fault status Flashing = Fault-process activity
Off = No fault-process activity
top
On, off, or A predictive failure alert has been received for this drive.
On or off Flashing
flashing Replace the drive as soon as possible.
On, off, or If the array is configured for fault tolerance and all other drives in
On Off the array are online, and a predictive failure alert is received or a
flashing
drive capacity upgrade is in progress, the drive could be replaced
online.
On or Flashing Off Do not remove the drive. Removing a drive may terminate the
flashing current operation and cause data loss.
Activity Online Fault
Interpretation
LED (1) LED (2) LED (3)
Status
Amber = Failed
Status
Off = No power
top
1 - LED 1 (Amber)
2 - LED 2 (Green)
LED 1 LED 2
Server Status Battery Module Status
(Amber) (Green)
Server is off and is in Flashing every User data held in the write cache is being backed
Off