Professional Documents
Culture Documents
MG9 MG10
Stone wall sub structure QQ MG11
7'-11 11/16"
ACOUSTIC INSULATION TO 02
RAINWATER PIPES
2430
All information is to be read in
INS-3 conjunction with technical reference
03 sheet, specifications and Engineers
documentation.
4'-2 3/8"
[6'-0"] designed and confirmed by the
1280
Landlord Structural Engineer. All
[2'-8 1/4"]
05 information on these drawings is
819
indicative only for the sole purpose of
informing the Landlord for his Base
build works. Final structural
[8'-10 5/16"]
06
dimensions should be obtained by
2700
referring to the Landlords drawings.
MGF 07
All indicative design, elements,
finishes and materials outside the Line
08 of Demise (LOD) are indicative only
and should not be used for any other
purpose. It must not be used for
09 construction.
[1'-3 3/4"]
[10'-0"]
[10'-0"]
400
3048
3048
1
A-533
[6'-2 13/16"]
1900
MGE
Apple Inc.
1 Infinite Loop
MS 52-RD
Cupertino, CA
[5'-0"]
1524
95014
[3'-3 3/8"]
1000
E 1
45'-11 5/16"
[35'-4 1/2"]
45'-11 3/8"
Architect:
[10'-0"]
14005
14004
10782
5
3048
AVENUE
WATER FEATURE
Foster + Partners
F23.01
VOID ABOVE www.fosterandpartners.com
[3'-3 3/8"]
1000
www.eckersleyocallaghan.com
Structural Engineer:
Atkins
wwww.atkinsglobal.com
MGD
Mechanical and Electrical Engineer:
Foster + Partners
wwww.fosterandpartners.com
MEP ROOM
[10'-0"]
3048
3048
Signed: mm/dd/yyyy
Apple Store
4'-5 1/2"
1359
E 1
7'-11 11/16"
2430
RWP INSTALLED BY 2
LL. REFER TO F+P 2 A-510
SETTING OUT A-533
1
A-508 1897 1829 1829
6'-2 11/16" [6'-0"] [6'-0"]
3783 1771
Apple Approval Date
12'-4 15/16" 5'-9 3/4"
MG8
TECHNICAL AVENUES
SOUTH - DETAILED PLAN
SOUTH TECHNICAL AVENUE PLAN - LEVEL 1 N
L01
1 1 : 25
MG10 MG9
DUCT
1'-6"
457
NATURAL STONE SLAB INTERNAL
WALL LINING INCLUDING information on these drawings is
MECHANICAL FIXINGS 20 indicative only for the sole purpose of
13/16" informing the Landlord for his Base
ST-1 build works. Final structural
dimensions should be obtained by
STONE BALUSTRADE referring to the Landlords drawings.
ST-5
1
All indicative design, elements,
A-638 finishes and materials outside the Line
of Demise (LOD) are indicative only
and should not be used for any other
14620 purpose. It must not be used for
construction.
1 1/4"
FFL LEVEL 2
31
Retained building elements shown
indicatively to be surveyed and
verified by contractor.
.00
135 Architect:
Structural Engineer:
Atkins
wwww.atkinsglobal.com
Foster + Partners
wwww.fosterandpartners.com
11 13/16"
300
7 2
15 02
/1
6"
Signed: mm/dd/yyyy
12,760 [41' - 10 3/8"]
Apple Store
120 48 20 112
4 3/4" 1 7/8"
13/16" 4 3/8" Sands Cotai Central
Macau, China SAR
2
A-638 This set originated using
Apple Imperial Bulletin 6.0
Rev-04 - Date 12/09/2015
Printed Full (30"x42"), Half (15"x21")
Issued/Revised Date
80%CD CONSOLIDATE 22/12/16
90% CD 18/01/17
100%CD 02/02/17
.00
23300
FFL LEVEL 3
1829
6'-0"
Notes:
All dimensions and areas subject to
confirmation by a building survey.
CUSTOM FABRICATED GLAZED
STRUCTURAL ROOFLIGHT SYSTEM Any area indicated on this sheet are
G-4 approximate and indicative only.
NO SUB-STRUCTURE
PASSING THIS AREA, FREE
TRUSS SUBFRAME TO MINERAL WOOL ACOUSTIC FOR MECHANICAL DUCT
SUPPORT STONE INSULATION TO TECHNICAL RISER PASSING THROUGH, TO BE
4 CLADDING.REFER TO PCE COORDINATED WITH STONE
INS-2 WALL SUB STRUCTURE
A-638 DRAWING SET 1'- 5
10 60 ENGINEER
1/
16
MEP DUCTWORK " Apple Inc.
LAST STONE PANEL 300MM
EXTENDED BEYOND FCL 1 Infinite Loop
MS 52-RD
Cupertino, CA
95014
T.L. STONE PANEL 21,770 [71' - 5 1/8"]
1 35 SADDLER AIR DIFFUSER ABUT
3/
8" STONE WALL, INTEGRATED TO
THE COVER PLATE
Structural Engineer:
100 20 48 20 112
3 15/16" 13/16"
1 7/8"
13/16" 4 3/8" Atkins
wwww.atkinsglobal.com
2
A-638
.00
135
NATURAL STONE SLAB INTERNAL
WALL LINING INCLUDING
MECHANICAL FIXINGS
ST-1
Issued/Revised Date
80%CD CONSOLIDATE 22/12/16
90% CD 18/01/17
100%CD 02/02/17
100%CD Rev01 22/02/17
100%CD Rev02 30/03/17
1532
5'-0 5/16" Apple Approval Date
20 1798
13/16" 5'-10 13/16"
TECHNICAL AVENUE
TECHNICAL AVENUE CROSS SECTION - TYPICAL CONNECTION DETAILS L3 SECTION DETAIL
1 1:5