You are on page 1of 2

Product data sheet 32896

Characteristics circuit breaker Compact NS630H - STR23SE -


630 A - 4 poles 4d

Main
Device short name Compact NS630H
Circuit breaker applica- Distribution
tion
Poles description 4P
Protected poles de- 3t
scription 3t + N/2
4t
Neutral position Left
Network type AC
DC
Network frequency 50/60 Hz
[In] rated current 500 A ( 65 C )
630 A ( 40 C )

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
[Ui] rated insulation 750 V AC 50/60 Hz conforming to IEC 60947-2
voltage
[Uimp] rated impulse 8 kV conforming to IEC 60947-2
withstand voltage
[Ue] rated operational 690 V AC 50/60 Hz conforming to IEC 60947-2
voltage 750 V DC conforming to IEC 60947-2
Circuit breaker rating H
code

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Breaking capacity Icu 100 kA at 220/240 V AC 50/60 Hz conforming to

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
IEC 60947-2
Icu 70 kA at 380/415 V AC 50/60 Hz conforming to
IEC 60947-2
Icu 65 kA at 440 V AC 50/60 Hz conforming to IEC
60947-2
Icu 50 kA at 500 V AC 50/60 Hz conforming to IEC
60947-2
Icu 35 kA at 525 V AC 50/60 Hz conforming to IEC
60947-2
100 kA at 240 V AC 50/60 Hz conforming to NEMA
AB1 HIC
65 kA at 480 V AC 50/60 Hz conforming to NEMA
AB1 HIC
[Ics] rated service Ics 50 kA 500 V AC 50/60 Hz conforming to IEC
breaking capacity 60947-2
Ics 65 kA 440 V AC 50/60 Hz conforming to IEC
60947-2
Ics 70 kA 380/415 V AC 50/60 Hz conforming to IEC
60947-2
Ics 100 kA 220/240 V AC 50/60 Hz conforming to
IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
Trip unit name STR23SE
Trip unit technology Electronic
Protection type Instantaneous short-circuit protection
Overload protection (long time)
Protection of the fourth pole
Short time short-circuit protection
Pollution degree 3 conforming to IEC 60947

Apr 28, 2017


1
Complementary
Control type Toggle
Mounting mode Fixed
Mounting support Backplate
Upside connection Front
Downside connection Front
Circuit breaker CT rating 630 A
Mechanical durability 15000 cycles
Electrical durability 8000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2
4000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2
Connection pitch 45 mm
Local signalling Positive contact indication
Neutral protection setting 0.5 x Ir
1 x Ir
No protection
Long time pick-up adjstment type Ir Adjustable 48 settings
Long time pick-up adjustment range 0.4...1 x In
Long time delay adjustment type Fixed
[Tr] long-time delay adjustment 3.2...5 s 7.2 x Ir
5...7.5 s 6 x Ir
90...180 s 1.5 x Ir
Short-time pick-up adjustment type Isd Adjustable 8 settings
[Isd] short-time pick-up adjustment range 2...10 x Ir
Short-time delay adjustment type Fixed
[Tsd] short-time delay adjustment range 0.04...0.06 s
Instantaneous pick-up adjustment type Ii Fixed
Instantaneous pick-up adjustment range 11 x In
Display type LED
Height 255 mm
Width 185 mm
Depth 110 mm

Environment
Standards IEC 60947-2
Product certifications ASEFA
ASTA
KEMA
LCIE
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to EN 50102
Ambient air temperature for operation -25...70 C
Ambient air temperature for storage -50...85 C
RoHS EUR conformity date 0911
RoHS EUR status Compliant