This document is to accompany the Canadian National Report for the Convention on Nuclear
Safety Fifth Report.
Catalogue number CC172-18/2010E-PDF
ISBN 978-1-100-16813-5
CNSC Catalogue number INFO-0805
April 2011
This document supplements the Canadian National Report for the Fifth Review Meeting of the
Convention on Nuclear Safety. By offering additional and detailed information in response to
113 specific questions received from 15 Contracting Parties, the document demonstrates how
Canada has implemented its obligations under the Convention on Nuclear Safety. This
document is produced by the Canadian Nuclear Safety Commission on behalf of Canada.
Contributions to the document were made by representatives from Ontario Power Generation,
Bruce Power, New Brunswick Power Nuclear, Hydro-Qubec, Natural Resources Canada,
Foreign Affairs and International Trade Canada and Atomic Energy of Canada Limited.
This page intentionally left blank
Table of Content
i
This page intentionally left blank
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
GENERAL COMMENTS
1 Ireland General N/A Ireland would like to thank Thank you for the comment.
Canada for preparing a
comprehensive national report
on the implementation of its
obligations under the CNS.
2 Korea, General Page 9 It is stated that calandria tube The CNSC reviewed the Point Lepreau replacement fuel
Republic of installation began at Point channel design description and design requirements
Lepreau as a part of documents very early in the project before the work began.
refurbishment and Gentilly-2 These documents included high level installation, test and
also plans the refurbishment. acceptance criteria for the calandria tubes. The CNSC also
Reportedly, many failures in reviewed the calandria vessel pressure test procedures,
the tests after new calandria which included the calandria tube rolled joint installation
tubes installation work and leak testing procedures.
occurred in your country. Does
CNSC review and approve the The detailed inspection and test plan for the calandria tube
calandria tubes installation installation were reviewed and approved by the Authorized
procedure before the work Nuclear Inspector (ANI). It was through the delivery of this
begins? Or does CNSC regard testing that the licensees contractor determined that the
it acceptable if the calandria tube installation was not adequate. A very close oversight
tubes pass the tests regardless of the installation of the calandria tubes was maintained by
of the calandria tube CNSC site officers and CNSC engineering specialists
installation methods? through a Type 2 inspection (audit) and meetings with the
licensee on the problems with the installation, the root cause
investigations, and options for resolution of the problems.
Original Reference in
Ser Country Question/Comment Response
Reference Report
Original Reference in
Ser Country Question/Comment Response
Reference Report
Pickering B reactor units, the economic benefits of
continued operation of the units to the end of their service
life, and the overall Province of Ontario electricity
supply/demand situation over the potential refurbishment
period.
Original Reference in
Ser Country Question/Comment Response
Reference Report
refrain from engaging into any political or partisan activity
during their mandate. They hold office during good
behaviour for up to 5-year terms (renewable), meaning that
they can only be removed for cause (as opposed to being
appointed at pleasure).
Original Reference in
Ser Country Question/Comment Response
Reference Report
8 Switzerland Article 7.1 Page 24 The report says that the CNSC Refer to Serial 7 for response.
has a Commission Tribunal.
This Commission Tribunal is a
quasi-judicial administrative
tribunal that establishes
regulatory policy and makes
independent licensing
decisions as well as legally
binding regulations. Please
outline the requirements
regarding the professional
background and nuclear safety
know-how of the members of
this tribunal.
9 United Arab Article 7.1 Page 46 It is stated that in the new Since the publication of the Canadian report to the fifth
Emirates licence format the licensee CNS review meeting, the wording of the two first General
must obtain prior written Conditions was changed to read as follows:
approval from the Commission
Tribunal before making any 1. General
change to the licensing basis 1.1. The licensee shall conduct the activities described in
that could adversely affect the Part IV of this licence in accordance with the licensing basis
safe conduct of the licensed described in the associated LCH for the nuclear facility.
activities. Please describe any (i) Changes to the safety and control measures described in
criteria by which the licensee the application and the documents needed to support that
and Commission staff decide application are permitted provided that the objective of the
which changes are safety licensing basis is met.
related and trigger the (ii) Changes that are outside of the boundary conditions set
requirement for prior approval. by the licensing basis are not permitted without the prior
Please cite a few examples if written approval of the Canadian Nuclear Safety
available. Commission (hereinafter the Commission).
Original Reference in
Ser Country Question/Comment Response
Reference Report
Original Reference in
Ser Country Question/Comment Response
Reference Report
DC power supplies; in this case, CNSC staff recommended
against the acceptance of such a proposal.
10 United Arab Article 7.1 Page 49 Please give details of a typical The Compliance Baseline is a pre-defined 5-year schedule
Emirates baseline set of inspections of compliance activities that cover all Safety Areas and
for a typical operating plant. Programs and which represents the minimum set of
compliance activities required to verify licensee compliance
with Regulatory Requirements.
7
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
Refer to Question #18 for additional information and on the
distinction between Type I and Type II inspections.
11 United Arab Article 7.1 Page 36 It is noted that Canada has The outline for procedures published so far is explained and
Emirates made progress in developing can be found at the CNSC website using the following link:
review procedures that foster a
consistent and transparent http://www.nuclearsafety.gc.ca/eng/licenseesapplicants/pow
approach for oversight of erplants/newapplicants/staff_review_procedures/index.cfm
regulated facilities. Please
outline the topics addressed by The topics addressed were based on consideration of IAEA
the CNSCs review GS-G-4.1 the Nuclear Safety and Control Act and its
procedures. regulations, the Canadian Environmental Assessment Act,
and the content of Environmental Impact Statement
Guidelines
12 Argentina Article Article 7.2.i - Regarding the regulatory Regardless of the size of a reactor the CNSC uses a risk
7.2.1 Annex 7.2 (i) framework for small reactors, informed review approach recognizing that additional
- Page 21 the report says (Article 7.2.i - review effort will be needed for novel approaches, and
Annex 7.2 (i) - page 212) that when alternative approaches to meet regulatory
the extent and rigour of the requirements are proposed. Particular attention is paid to
demonstration that the the proponents supporting research and development work
fundamental safety functions to support the proposed novel or alternative approaches.
are fulfilled during and
following a postulated Specific to small reactors, two new draft regulatory
initiating event vary depending documents RD-367 Design of Small Reactors and RD-308
on the reactor design. What are Deterministic Safety Analysis for Small Reactors allow for a
the general criteria used to graded approach to both design and safety analysis in
decide the extent and rigour of certain areas. This is a risk-informed approach that, without
such demonstration according compromising safety, allows safety requirements to be
the reactor design features? implemented in such a way that the level of design,
analysis, and documentation are commensurate with the
potential hazards posed by the facility.
13 India Article 7.2, Para 5, Can you please clarify, The CNSC frequency of document revision is needs-based.
7.2.1 Page 27 whether CNSC has a fixed Documents are reviewed, and revisions are planned and
frequency for revision of the scheduled, in accordance with their priority and the
regulatory documents or the availability of resources. Recent initiatives with respect to
8
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
revision is need based? the management of the CNSC's regulatory framework
include the establishment of a five-year review cycle for all
CNSC documents where these would be withdrawn and
archived, retained as is for continued use, or scheduled for
revision, depending on the outcome of the review.
14 United Article Page 26 The report states that During Formal surveys of stakeholders have not been undertaken to
Kingdom 7.2.1 the reporting period, Canada date. The CNSC makes a consistent effort to identify
continued its efforts to enhance stakeholders, including non-governmental groups,
transparency and engage as environmentalists, residents of host communities and
many interested stakeholders potential host communities, provincial and municipal
as possible in the regulatory officials, Aboriginal groups, as well as the public at large,
process. Has the approach and provides them with the opportunity to participate in the
been to identify all stakeholder regulatory process. For example, as part of the process for
groups and, since developing or amending regulatory documents or
communication is a two way legislation, stakeholders registered with the CNSC are
process, survey them for their notified in writing of the consultation and the draft
opinion of CNSC and the documents are posted on the CNSC Web site for public
regulatory process? If so, what comment. Comments received are dispositioned and the
are the questions asked of draft documents adjusted accordingly. All Commission
them, and how often are Tribunal hearings and meetings are open to the public.
surveys made, and with what Tribunal hearings are announced well in advance and the
size of sample? Are they agendas are posted on the CNSC Web site. Tribunal
carried out by an independent documents are available to stakeholders upon request. Any
organisation? stakeholder or member of the public may request the
opportunity to intervene in a Tribunal hearing either in
person on in writing. As well, all Tribunal hearings and
meetings are Web cast and transcripts are posted to the Web
site shortly after each hearing/meeting.
15 United Arab Article Page 38 The discussion of License to As discussed in Article 17, the Licence to Prepare Site
Emirates 7.2.2 prepare a site (7.2(ii)b) application is the forum by which an applicant demonstrates
specifies that it is the site suitability for future development and the application is
applicants responsibility to expected to demonstrate how the criteria in RD-346 Site
demonstrate to the CNSC that Evaluation for New Nuclear Power Plants have been met,
the proposed site is suitable for refer to page 144 of the National Report for details.
9
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
further development, and that
the activities encompassed by RD-346 is a feed-in document to a new Licence
the license will not pose an Application Guide being developed by CNSC staff entitled
unreasonable risk to health, GD-368 Licence to Prepare Site for a Class I Facility:
safety, security and the Nuclear Power Plants and Small Reactors. This document
environment for the site and its goes into considerably more detail on how staff expects an
surrounding region. The fourth applicant to demonstrate site suitability for future
paragraph refers to CNSC development. This document is anticipated to be issued for
document RD-346 as public consultation in the summer 2011.
describing the general process
for evaluating an NPP site in
Canada, and the first bullet on
page 39, provides site
evaluation criteria (e.g. to
address the effect of the site on
the environment, emergency
planning, and natural and
human-induced external
hazards) There is no mention
of RD-346 provisions for
demonstrating that the site is
suitable for further
development; is this in fact
addressed? If so, recommend
reference to RD-346 in Article
17. If not, recommend adding a
reference to another
implementing document, if one
exists.
16 United Article Page 42 In order to accept the first Should a licensee propose, prior to the granting of a Licence
Kingdom 7.2.2 charge of fuel on the site and to Operate, to accept the first charge of fuel on the site and
store it, certain nuclear safety store it, an amendment to the Licence to Construct would be
and radiation protection required along with a demonstration that the facility to be
requirements have to be in used for accepting and storing that fuel will meet regulatory
10
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
place. Can Canada explain requirements. This amendment would likely require
how the regulation of this Commission approval.
activity is accommodated
within the Licence to operate In the interests of efficiency, the licensee should anticipate
arrangements as the licence this activity in their initial application for the Licence to
will not have been granted at Construct along with details of the commissioning program
this time? needed to demonstrate that the fuel acceptance and storage
facility meets requirements. The licence would then contain
a suitable hold point to permit fuel delivery only after
CNSC has confirmed the conditions of the hold point have
been satisfied.
17 United States Article 7.2, The report states that CNSC It is the CNSCs practice to develop and maintain
of America 7.2.2 Page 37 carries out its assessment of an Memoranda of Understanding (MOU) with government
applicants supporting bodies at the federal level having independent but related
information with input from responsibilities with the CNSC in relation to nuclear
other federal and provincial projects. While the overriding objective of these MOUs is
government departments and to reduce duplication of regulatory effort and streamline the
agencies responsible for regulatory process, these arrangements ensure that all
regulating health and safety, obligations contained in Canadian legislation continue to be
environmental protection, met. Consequently, information contained in an
emergency preparedness, and application, including protected information, may be shared
transportation of dangerous between federal departments and agencies to the extent
goods. What is the nature of necessary to evaluate the proposed projects compliance
arrangements between CNSC with legislation. Although the CNSC has several MOUs in
and the other governmental place with other federal bodies, the CNSC is obligated to
bodies for the sharing of comply with any federal legislation and therefore may
licensing information? consult with any department or agency in assessing an
application, even in the absence of an MOU, sharing any
information required to complete the analysis.
Original Reference in
Ser Country Question/Comment Response
Reference Report
12
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
Reactive inspections (Type I or II) are conducted based on
evidence of a potentially declining licensee safety
performance (Type I or II) or when major changes to a
licensee program are being implemented (Type I).
Original Reference in
Ser Country Question/Comment Response
Reference Report
Safety and Control act and associated regulations.
Typically, CNSC staff conveys written notices to licensee
by letter to arrange for the timely resolution of safety related
issues (e.g., a staff request to the licensee to develop and
execute a corrective action to address a deficiency identified
during a CNSC inspection). These types of written notices
are, in fact, issued to all NPP licensees on an ongoing basis;
many were issued during the reporting period.
ARTICLE 8: REGULATORY BODY
20 Ireland Article 8.1 Page 67 - 69 The report notes that while Some senior technical positions were more challenging to
CNSC has been successfully fill given the limited availability of qualified personnel but
maintaining and growing its the CNSC was ultimately successful in its recruiting. In
employee numbers there have some instances, the CNSC has recruited candidates with
been some skills sets that are specialized education at more junior levels and has focused
more challenging to fill. What on training of these employees as well as providing them
skill sets are these and what with various work terms within the organization.
steps are being taken to
address any emerging gaps? In the advent of resurgence in new builds, the CNSC would
How does CNSC anticipate the face increased pressures to retain staff as it would have to
need for the NPP operator to compete with industry for the same pool of qualified
recruit staff, whenever the individuals.
proposed new nuclear build
projects commence, will CNSC has been able to retain its staff over the last few
impact on its retention of staff? years and the turnover rate is minimal. At the moment, it is
focusing its HR strategies on retaining staff through
concerted efforts to be an Employer of Choice.
21 Korea, Article 8.1 60 It is stated that CNSC shall The CNSC is independent from outside influence, including
Republic of report to the Parliament the federal government, in the conduct of its activities. The
currently through the minister CNSCs decisions are not subject to review by the Minister
of Natural Resources Canada or other parts of the executive. The CNSC is accountable to
and also CNSC get support of the public and to the Parliament through an annual report
the minister of Natural that is submitted to Parliament, which is submitted through
Resources Canada when it the Minister of Natural Resources Canada. Conflict of
seeks incremental funding. interest guidelines also provide assurances that there is
14
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
Under this circumstance, how distance between the Commission and stakeholders.
does CNSC ensure the
regulatory independence from The CNSCs budget partially comes from Treasury Board
the Ministry of Natural through appropriation and over 70 percent of its budget is
Resources Canada which cost recoverable through the application of the Cost
controls the licensees such as Recovery Fees Regulations. Effective April 1, 2009, CNSC
NRU and also has primary receives its funding from two sources and they are:
interest in operating the
facilities? Fees paid by applicants, licensees and other special
project sponsors in accordance with the CNSC
Revenue Spending Authority approved by Parliament
and applied in accordance with CNSCs Cost
Recovery Fees Regulations. The Commission has the
statutory authority to prescribe and charge fees for the
services, products and information that it provides
under the NSCA, and the fees may not exceed the
costs to the CNSC of its regulatory activities (ss. 44
(1), (2) and (3), 21(1)(g), NSCA); and
Original Reference in
Ser Country Question/Comment Response
Reference Report
(1), (2) and (3), 21(1)(g), NSCA)
Original Reference in
Ser Country Question/Comment Response
Reference Report
employment with the CNSC.
23 United Arab Article 8.1 68 CNSC is to be commended for Thank you for the comment.
Emirates integrating succession
planning with its formal
Individual Learning Plan
process.
24 United Arab Article 8.1 55 Based on Canadas experience, The original legislation in Canada governing nuclear safety,
Emirates what measures has Canada the Atomic Energy Control Act of 1946, encompassed both
taken to preserve their regulatory and developmental aspects of nuclear activities.
independent nuclear safety When the new Nuclear Safety and Control Act (NSCA) was
authority in the face of enacted in 1997, the regulatory and developmental functions
political pressures, media were separated in law. The NSCA (section 8) denominates
attention or national interests? the CNSC as the regulatory body in Canada. It clearly
distinguishes its regulatory role from that of organizations
involved in development, marketing, or utilization of
nuclear energy or substances. No other authorities than the
CNSC are involved in the licensing and the regulation of the
safety aspects of nuclear activities.
25 United Arab Article 8.1 55 Please clarify from Canadas As mentioned in Section 8.1 of Canadas 5th report, the
Emirates experience how best to utilize CNSC no longer makes use of standing advisory bodies
the expertise of independent (although there are provisions to allow it). CNSC has, on
experts (e.g., TSOs) in staff, a large contingent of highly-qualified technical and
17
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
evaluating and making regulatory experts with expertise across many disciplines, as
recommendations on technical described in Section 8.1 b. Conflict of interest provisions,
or regulatory issues while still including ethics training, help reduce further the likelihood
maintaining independence? of undue outside influence on CNSC affairs. Although the
wide knowledge base allows most issues to be assessed by
staff in house, outside expertise is occasionally engaged
for certain technical or regulatory issues. In these cases, it
is still important to have a wide base of expertise within the
CNSC to properly maintain smart buyer capability.
Having adequate breadth and depth of knowledge to
critically assess all types of recommendations from the
outside is critical to assessing if the CNSCs purposes are
truly being served by the recommended position or course
of action.
Original Reference in
Ser Country Question/Comment Response
Reference Report
26 United Arab Article 8.1 66 In the directorate of safety The Divisions within the Directorate of Safety Management
Emirates management there is a provide specialist advice in the assessment and
Management Systems implementation of regulatory programs in the areas of:
Division. What is the role of human factors, human performance, organization and
this division with respect to the management, quality assurance, quality management and
the Personnel Certification management systems, personnel certification, examination
Division and the Human and and testing and personnel training.
Organizational Performance
Division? The three Divisions referred to are integrated within the
Directorate of Safety Management and provide specialist
advice in the assessment and implementation of regulatory
programs in the areas of: human factors, human
performance, organization and management, quality
assurance, quality management and management systems,
personnel certification, examination and testing and
personnel training.
Original Reference in
Ser Country Question/Comment Response
Reference Report
train newcomers. Has this been #22 for details) which outlines the necessary steps necessary
a one-off ad hoc process or has to qualify an individual to the requisite inspector
CNSC now established a certification through various formal courses and practical
formal competence hands on training. The training program includes regulatory
management system, within its core training and service line specific training as well as on-
overall management system, to the-job training experience. The CNSC is proactive in
deal with: using the overall ensuring staff competencies remain current and regularly
strategic plan to systematically compiles and analyzes information of learning needs and
assess competence needs, in gaps to plan learning activities across the organization. A
the near term and longer term similar process is in development for Regulatory Program
future; and planning and Officers.
delivering recruitment, training
and other elements of
competence development?
Section 11.2 a (page 93) refers
to the Systematic Approach to
Training for licensees, is this
approach used in CNSC?
28 United States Article 8.1 8.1, p 68 CNSC has been very The CNSC in its efforts to become an Employer of Choice
of America successful in recruiting new and increased its presence in various forums and focusing
staff over the past few years. on youth. In parallel, it has developed targeted recruitment
What lessons learned and good material, applied to Canadas Top 100 Employers
practices regarding recruiting competition, increased its participation in external awards
and hiring strategies can you and advertised in multiple job sites. It also developed a
share with other countries staffing framework to provide hiring managers with as
facing challenges in this area? much flexibility and accountability as possible while
respecting key values.
29 China Article 8.2 8, 55 What progresses did the CNSC During the reporting period, the CNSC continued to
make in respect to the maintain its well-established authority as the single,
independency of its independent nuclear safety regulator in Canada. This was
supervisory and regulatory enhanced by progress in areas that contribute to well-
within the time limit of the informed and transparent regulatory decisions. Progress in
report. achieving openness and transparency in regulatory
activities, as well systematically basing decisions on a
20
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
balanced approach to evaluation of all risks, are described in
Section 8.2 b of Canadas 5th report.
Original Reference in
Ser Country Question/Comment Response
Reference Report
the Department of Natural Resources Act, 1994 for the
development of nuclear policy by the Minister of
Natural Resources Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
provides under the NSCA, and the fees may not exceed the
costs to the CNSC of its regulatory activities (ss. 44 (1), (2)
and (3), 21(1)(g), NSCA)
23
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
review method to evaluate method was developed over several years in which it was
organizational influences on applied to a number of nuclear power stations and other
licensees safety culture . 1) facilities. Safety culture was one factor assessed by the
How using the above O&M review method but was revealed by Factor Analysis
mentioned method can be to be the best predictor of safety performance. In addition
assessed the organizational and the safety culture framework, which is based on 16
management attitudes and performance indicators linked to six distinct safety culture
behaviours related to licensees characteristics, is used to assess organization and
safety culture? Please, if it is management weaknesses which are involved in reportable
possible give some example of events.
the method application. 2)
Were developed/implemented See response to Question #32 for more information on
some performance indicators potential performance indicators for Safety Culture.
to measure specific plant
safety culture aspects?
31 China Article 10 10, 87 Would you please provide The CNSC encourages the NPPs to conduct their own
further explanations on the safety culture self-assessments (SCSAs). There were two
positive enhancement or notable assessments conducted during the period of the
impact brought by safety report. The first when an NPP identified a major weakness
culture reviews conducted by in its safety systems which had not been recognized for
Canada NPPs within the time several years. Some of the causes for this weakness were
limit of the report? ascribed to the organizations safety culture. A self-
assessment was conducted, the specific weaknesses
identified and a detailed corrective action plan developed to
deal with all the related issues. The second instance
occurred when the Commission requested that CNSC staff
conduct a separate safety culture assessment which was
done in collaboration with an independent contractor using
the CNSCs Organization and Management Review
method. The results of both the SCSA and the CNSC
assessments were compared. The comparison revealed
general agreement and specific opportunities for
improvement in both methods. The advantage of the self-
assessment clearly lies in the fact that since the NPP
24
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
conducted the assesment the results and outcome are likely
to be accepted more easily.
32 Germany Article 10 Page 89, 10.d It is stated This requires the Safety culture is a concept which refers to attitudes and
last development of performance perceptions but which cannot be regulated in themselves.
paragraph indicators to manage safety However, the safety policies, the behaviour of leadership,
culture improvement from the speed and depth of response to the raising of safety
current status to new targets. concerns are all behaviours which are both determined by
Please elaborate how the culture and which, in their turn affect the expectations
indicators can be used to and attitudes of others. The performance indicators
manage safety culture referred to in the document are leading signals of
improvements. perceived weakness and refer to observable performance of
people at different levels of the organization. Quantitative
counts and qualitative assessments of proactive leadership,
effective development and adhereance to safety procedures
by middle management and careful work practices by
workers can be used as indicators. However, it is important
to recognize the safety culture is more than one set of
attitudes or types of behaviour and can only be promoted,
strengthened and maintained by a concerted effort by staff
at all levels.
33 Germany Article 10 Page 89, It is stated The CNSC draft The CNSC examines documents describing the licensees
chap. 10 c, document Guidance for proposed self-assessment approach and reviews plans to
second last Licensee Self-assessment of conduct specific assessments, and critiques the results
paragra Safety Culture has been collected. The NPPs are provided feedback on planned
distributed to NPP licensees corrective action plans (CAPs) that may arise from the
for guidance, and was used as CNSCs reviews.
a framework for commenting
on selfassessments done by The CNSCs approach towards self-assessments is not
several facilities. Does CNSC prescriptive. This means CNSC does not apply
plan to follow the self- compliance per se to Safety Culture Self Assessments.
assessments of the NPPs? Is it The CNSC draft document Guidance for Licensee Self-
planned to perform regular assessment of Safety Culture outlines the key elements to
inspections or assessments of ensure that the method used conforms to some basic criteria,
these selfassessments? such as being able to withstand review by peers, being
25
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
practical etc.
34 Romania Article 10 section 10 c How does the CNSC regulate CNSC Staff reviews licensee management and
the management of organizational change procedures and conduct inspections
organisational change (i.e. has to evaluate the effectiveness of their implementation.
the CNSC issued any specific Guidance is provided through change control criteria
guidance to licensees on this established in the Canadian Standards Association (CSA)
matter)? Standard N286 Management System Requirements for
Nuclear Power Plants which is a licensing requirement
integrated into the NPPs operating licence. IAEA Standards
and Guides such as GS-R-3 The Management System for
Facilities and Activities and NS-G-2.4 The Operating
Organization for Nuclear Power Plants provide additional,
but non mandatory guidance.
Original Reference in
Ser Country Question/Comment Response
Reference Report
performance? approach to the qualification of inspectors through some
basic training on the topic of safety culture, some of the
signs of a weakening health in safety culture and some
guidance on when to involve specialist to enhance
inspections. Special training and checklists for site
inspectors is also being considered to allow them to more
easily detect indicators of the health of the safety culture
through regular inspections or in the course of surveillance.
36 Switzerland Article 10 89 The report says that the CNSC The CNSC Organization and Management (O&M) Review
is in the possession of a review method was developed in collaboration with an outside
process to evaluate contractor who used the results of several assessments to
organizational influences on identify the factors which best predicted the health of safety
licensees safety culture. The culture. The method also uses several concurrent but
method used to conduct this different methods to assess safety culture. The use of
process is indicated to be surveys, interviews and observations allowed cross
validated, objective and verification.
systematic. Which are the
criteria or method(s) this The use of an outside contractor to help conduct safety
process was validated against? culture assessments has provided an added level of
How do you ensure objectivity objectivity when reviewing the data collected and when
when CNSC staff is executing determining the wording of weaknesses we uncover.
this process and
analyzing/interpreting the data
gained from it?
37 United Arab Article 10 89 An event in 2009 identified The weaknesses in the organizations safety culture were
Emirates possible weaknesses in the identified in a safety culture self-assessment and in the root
organizations safety culture. cause analysis following a severe leak. The fact that these
Please provide the elements of two methods pointed to the same weaknesses stressed the
the corrective action plan. importance and validity of the issues. The CNSC asked for
What is the organization and both a prioritization of the actions and an itemized
management review method? corrective plan to address them.
Original Reference in
Ser Country Question/Comment Response
Reference Report
oversight of organization and management issues. The
method was developed over several years in which it was
applied to a number of nuclear power stations and other
facilities. Safety culture was one factor assessed by the
O&M review method but was revealed by Factor Analysis
to be the best predictor of safety performance along with the
safety culture framework used to assess organization and
management weaknesses which are involved in reportable
events.
38 United States Article 10 10c, p 89 The report references the The organization and management (O&M) review method
of America organization and management has not been used systematically and recurrently. It is not
review method as a means of part of an inspection plan since the approach of the CNSC
evaluating organizational towards Safety Culture is to promote and not to enforce a
influence on licensees safety compliance approach. An O & M assessment is performed
culture. Is this method used on when the CNSC identifies the need to perform it.
a recurring basis as part of a
routine inspection plan, or is it It is available and used as an element in the review of the
mainly employed in response NPP before license renewal, which in Canada is done every
to events where safety culture few years. As correctly identified in the question, the
is a causal factor? method is also employed in response to events where safety
culture is a possible causal factor.
Original Reference in
Ser Country Question/Comment Response
Reference Report
a succesfull Alumni Program and has created a corporate
succession planning fund to enable knowledge transfer and
sound succession planning.
40 United Arab Article 100 How does a good practice The question is not understood. There is no reference to
Emirates 11.1 become an important practice. important practices in the context of p. 100 of the report.
Please give an example.
41 Argentina Article Section 11.2a Related to training and Many licensees are still in the process of implementing
11.2 Page 93 certification of workers, it was criteria to measure training effectiveness, so its difficult to
reported that a criteria to comment on the experience of the industry as a whole.
measure training effectiveness However, as a specific example, Bruce Power uses the
are being put in place (Article Kirkpatrick Model for learning evaluation. To evaluate
11 - Section 11.2a page 93). training development requirements, a Training
Could be detailed each criteria Effectiveness Evaluation Worksheet is used to identify the
used and the corresponding issue driving the need for training and to determine specific
results/experience of their training topics, the expected results and the preferred
implementation? method to evaluate training effectiveness. There are a
number of criteria to measure the effectiveness of the
training. These could include: trainee knowledge evaluation
(written exam), trainee performance evaluation (lab, on the
job evaluation, etc), performance indicator reviews (i.e.
human performance), focus area self assessments, field
observations, interviews, supplemented assessments
(internal nuclear oversight, peer reviews) and others. These
criteria are set up during the development of the training
and will differ depending on the expected results and
behaviours that the training is designed to deliver. Forx
example, Bruce Power has seen some positive results since
instituting this method of training effectiveness evaluation
in 2008.
42 Germany Article Page 93, Common training courses Thank you for the comment.
11.2 chap. 11.2a, between regulatory body and
4th industry are a remarkably good
paragraphe practice.
43 United Arab Article 93 We have noticed that the The licensees training programs are not described in detail
29
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
Emirates 11.2 operating experience factor of in Section 11.2 of the report because they cover a very large
the training program is not number of technical and other areas. Certain broad
mentioned. Is that because in categories are briefly described operations, maintenance,
Canada the TSOs are handling radiation protection, and regulatory affairs. Although
the operation experience OPEX practices are not mentioned, they are, in fact, also
responsibility? And, if that is covered in the curriculum of licensee training courses.
the case, how do you as athe Furthermore, the contents of licensee training courses are
regulator ensure that the TSOs also updated regularly to reflect changes in experience,
are analyzing the pertinent information, practices, etc.
reports ?
ARTICLE 12: HUMAN FACTORS
44 India Article 12 12 c, Page What is the minimum time Following the first clear and unambiguous indication of the
104 considered for operator to take necessity for operator actions, such actions may normally be
action in case of any transient credited in safety analysis level-3 defence in depth no
or emergency conditions? sooner than:
30
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
31
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
45 Korea, Article 12 Section 12 c According to the descriptions The CNSC does not require that its licensees use a
Republic of of section 12 c, the human particular method to calculate the Human Reliability
reliability analysis is Analysis (HRA), but rather verifies that the HRA method
considered to estimate the chosen meets the requirements of CNSC Standard S-294,
probability that a system- Probabilistic Safety Assessment (PSA) for Nuclear Power
required human action, task, or Plants, and that they are done in an industry-recognized and
job required for safety will not systematic way. One method frequently used is the
be completed successfully Technique for Human Error Rate Prediction (THERP).
within the time period. And
licensees use industry-accepted
human reliability analysis
methods within their PSAs.
What are the regulatory
positions for assuring the
appropriateness of the results
of human reliability analysis in
the qualitative and quantitative
aspects which will be
performed by licensee?
46 Korea, Article 12 Section 12d According to the description of The CNSC requires the licensee to demonstrate the logic
Republic of section 12 d, to ensure that the behind its procedures and a well developed task analysis is a
operations and maintenance good way to demonstrate this. The word SHOULD is used
procedures are fit for purpose to indicate that a task analysis is not mandatory and no
and to develop technical steps method is specified although the method used is required to
in the procedures, the license be explained if it is conducted.
should use information from
task analyses. What are the
regulatory positions for
ensuring the appropriateness of
the scope and methodology of
task analysis which will be
performed by licensee?
47 Switzerland Article 12 224 (Annex The report says that in the From an industry point of view, AECL develops a Human
12b) Canadian nuclear industry, Factors review plan for each modification to a system or
32
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
HFE principles are applied in group of systems for a refurbishment project. The plan has
e.g. modifications to existing 12 elements and is based on the USNRC NUREG 0711
NPPs. Please describe these Human Factors Engineering Program Review model. The
principles as well as the elements that are included are: HFE Program Management,
proceeding to integrate them Operating Experience Review, Functional Requirements
into the plant modernisation Analysis and Function Allocation, Task Analysis, Staffing
process? and Qualification, Human Reliability Analysis, Human-
System Interface Design, Procedure development, Training
Program development, Human Factors Verification and
Validation, and Design Implementation (Integration) and
Human Performance Monitoring.
Original Reference in
Ser Country Question/Comment Response
Reference Report
is CNSCs approach to
considering human and The CNSC has emphasized human and organizational
organizational factors in new factors throughout CNSC Regulatory Guide, DRAFT
NPPs limited to consideration RD/GD-369 Licence Application Guide: Licence to
of human factors in design or Construct a Nuclear Power Plant and has also emphasized
are aspects such as the the importance of demonstrating the knowledge, skills and
development of the future abilities of the applicant, the vendor, major contractors, and
operating organization, their sub-contractors and safety culture.
consideration of human factors
during construction, The CNSC will continue to focus on human and
development and evolution of organizational factors throughout the whole project.
the project organization
throuout the whole project etc.
subject to CNSCs oversight
and formulation of
requirements as well?
49 United Article 12 Page 103 The Canadian Fourth Report With respect to the first question, the CNSC observed a
Kingdom (Page 69) stated In the next continuing difficulty of licensees being able to source
reporting period, CNSC staff suitably qualified Human Factors personnel to conduct the
will continue to monitor analysis of requirements and the creation of purchasing
closely the incorporation of requirements for modifications. The reference to
HFE in the design and expanding the approach to address human performance at
modification process, staffing an organizational level refers to improving licensees
levels and limits to hours of understanding of the breadth of human factors which can
work. These factors may influence human performance.
become even more important
because of the increased In regards to leading indicators, it is true that overtime
activity in the industry and a working can indicate a response to increasing time pressures
shortage of qualified personnel or can result from excessive delays. This can be a leading
in many disciplines. The measure of an increasing probability of risk or of decreasing
increasing reliance on the use safety.
of contracted staff at the NPPs,
and the necessary management In relation to the length of shifts worked by NPP staff, the
and oversight thereof, will also CNSC is currently developing its regulatory oversight
34
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
be an area of focus. Can regarding hours-of-work in an effort to reduce the
Canada explain what was the possibility of fatigue.
outcome of these monitoring
activites and how it relates to
the statement in the fifth
report, page 103 CNSC staff
is working with licensees to
expand the approach to address
human performance at an
organizational level? The
report also states CNSC staff
is also investigating useful
leading indicators of human
performance that accurately
reflect safety performance,
rather than relying on lagging
indicators (such as event-free
days). Is one of these
indicators related to overtime
working? Has CNSC required
from licensees a demonstration
that the lengths of shifts
worked by NPP staff do not
introduce deleterious fatigue?
ARTICLE 13: QUALITY ASSURANCE
50 Germany Article 13 Page 110, It is stated It is expected that The CNSC designed its compliance program to continually
chap. 13.c, new integrated management assess a licensees management systems. However, due to
last system requirements will be the size and complexity of licensee organizations,
paragraph gradually implemented over a compliance reviews and inspections only address specific
few years. How often will the elements of the management system over the licensing
regulatory body assess the period (currently, five-years typically) so that an overall
management system of the view is obtained prior to license renewal.
licensee? What are the
potential requests or sanctions, Major deficiencies are dealt with in the same way as other
35
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
if the assessments reveal major non-compliancees through the issuance of Action Notices or
deficiencies? Directives, depending on the nature of the deficiency,
requiring corrective and preventive actions implemented
consistent with an agreed timeline. For extreme cases, a
Designated Officer can issue an Order to a licensee for
immediate corrective actions, but to date this has not been
necessary. Shortened licensing periods and operating
restrictions are also additional options that may be
considered.
51 United Article 13 Page 111 The report states that The majority of NPP licensees have implemented a
Kingdom integrated management management system that integrates the various business and
systems are to be introduced in regulatory requirements consistent with CSA N286-05
NPPs aligned to GS-R-3 and Management System requirements for Nuclear Power
mentions the management of Plants. The phased-in approach relates more to the non-
organisational change and NPP (i.e. Class1A and 1B facilities and Uranium Mines and
continuous improvement. How Mills) where separate quality, environment, and health and
are these activities organised at safety programs tend to exist.
the moment and how does
CNRC judge the adequacy of NPP licensees have procedures for the management of
licensees arrangements? organizational changes and are expected to continuously
improve their management system. For example, OPG's
management system is aligned with Canadian Standards
Association CSA N286 "Management System requirements
for Nuclear Power Plants" standard as a condition of our
plant power reactor operating licences.
Original Reference in
Ser Country Question/Comment Response
Reference Report
improvement and evolution of licensees management
systems are evaluated over the course of the licensing
period.
Original Reference in
Ser Country Question/Comment Response
Reference Report
category1/2/3 and subsequent classified to a lower category, the licensee must
evaluation and disposal will be demonstrate that the risk control measures (or corrective
conducted based on category. actions) taken or committed in accordance with an accepted
This is very meaningful and schedule, are such that the risk significance level posed by
will contribute a lot to the issue is reduced. Activities vary from research and
increasing the safety development programs to more analyses aimed at reducing
confidence of the reactor, how uncertainties.
does it progress? Shall we
consider to share the results The CNSC report describing the Category III issues and the
and benefits among the candu required risk control measures was produced in August
reactors in some certain way? 2009 and is a publicly-available document. Copies of that
report were distributed to the CANDU Senior Regulators at
their 2009 meeting.
54 China Article 14.(), 119 There are several Canada An integrated safety review was completed as per
14.1 NPPs under refurbishment requirements of the CNSC Regulatory Document RD-360
which requires long working Life Extension of Nuclear Power Plants. This review
periods and big amount of ensures safety considerations are met. The economics were
funding, so how to make a assessed by performing a cost /benefit analysis, this analysis
good balance between the became part of the business case for the refurbishment
economics and safety? project to ensure that a balance between economics and
safety is attained.
55 Germany Article Page 115, For the licensing of The results of the application of C-006 Safety Analysis of
14.1 section 2 Darlington, the CNSC CANDU Nuclear Power Plants on a trial basis can be found
consultative regulatory in Part 3 of the Darlington Safety Report 'Accident
document Requirements for Analysis', the latest version of which was issued in 2009, it
the Safety of CANDU Nuclear having been updated every three years since its original
Power Plants (C-006) was used issue.
on a trial basis. What are the
results? Are there any results The Accident Analysis demonstrates that the requirements
for the other Canadian Nuclear for single and dual failures contained in C-006 are met. The
Power Plants? assumptions made in the safety analysis when
demonstrating that the requirements are met form the basis
for the safe operation of the Darlington NPP. The limits
and conditions associated with the safety requirements
38
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
constitute the Safe Operating Envelope.
Original Reference in
Ser Country Question/Comment Response
Reference Report
for the most part not anticipated to occur until at least 15
hours from the start of an event.
Original Reference in
Ser Country Question/Comment Response
Reference Report
documents it was required to events as LOCA with LOECCS deterministically.
be shown that event sequence Nevertheless, the contributions of such events to risk are
like LOCA with LOECCS evaluated through PSAs.
meet these dose limits. With
issue of RD-337 ( where dose
limits for AOO and DBA are
specified as 0.5 mSV and 20
mSV respectively) and RD
310 (where event classification
cut off frequency for AOO and
DBA are given as 10-02per
reactor year and 10-05 per
reactor year respectively),
what would be resolution of
event sequences like LOCA
with LOECCS while aligning
safety analysis of existing
reactors with these new
documents
58 India Article Annex 14 (i) It is stated that in 2009 RD-337 applies only to new reactors constructed after the
14.1 b, Page 230 revision of Pickering PSA issue date of RD-337, and hence does not apply to Pickering
level-1, the estimated severe or Darlington NPPs. However, OPGs current Risk and
core damage frequency is Reliability (R&R) program (N-PROG-RA-0016) sets both a
3.6x10-05 per year. It is noted target for SCDF (< 10-5 per year) and a limit for SCDF (<
that RD-337 was issued in 10-4 per year). Therefore the OPG target is consistent with
2008 where significant core RD-337. In situations where the estimated SCDF exceeds
damage frequency is stipulated the target, but meets the limit (such as the case with
to be lower than 1.0x10-05 per Pickering), the OPG R&R program requires us to
year. In view of this whether investigate the implementation of cost-effective measures to
any design improvement was meet the target. This evaluation will be completed as part
contemplated or whether for of the overall Operational plan to end of life for Pickering.
operating NPPs targets existing
prior to issue of RD-337 will
continue to be applicable.
41
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
59 India Article Para 3 (3rd Safety Analysis Methods and Certain combinations of PIEs with failures of mitigating
14.1 bullet) Page Acceptance Criteria for systems were required to be considered by the consultative
115 Operating NPPs: It is regulatory document C-006, which was used on a trial basis
mentioned that combinations for licensing of Darlington NPP. The approach adopted in
of postulated initiating events this document was deterministic rather than a probabilistic
with failures of mitigating one, since at the time when C-006 was issued PSA was not
systems (not just the classical viewed as a mature methodology. See also answer to
dual failures) were explicitly Question #60.
required to be considered.
What is the basis of
considering the combination of
PIEs with failure of mitigating
systems and whether it is based
on frequency of occurrence?
60 India Article Page 196, G.2. CANDU Safety Issues As part of the single-dual failure approach used previously,
14.1 Appendix-G: Associated with LBLOCA: It it is true that certain dual failures, such as LBLOCA
is mentioned that unlikely combined with the unavailability of ECC, had to be
combinations of events, such analyzed deterministically. The new regulatory approach,
as LBLOCA combined with which is based on RD-337 and RD-310 documents, allows
unavailability of ECC have re-classification of these events to BDBA, and analysis in
been considered in the design the the context of the periodic safety goals.. The previous
of the CANDU reactors. Even approach will be revisited along with the planned adoption
though these event of RD-310 for existing, operating NPPs in Canada. See also
combinations are considered answer to Question #59.
by other jurisdictions to belong
to the beyond design basis
accident (BDBA) category,
they are currently treated as
DBA in the Canadian
regulatory framework. Please
clarify i. Are these
combinations considered as
part of design basis? ii. Is there
any reason why events
42
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
belonging to BDBAs as per
other jurisdiction are
considered as DBAs for
CANDUs? Whether this
approach will be re-visited for
the new reactors in the light of
requirements given in RD-310,
which requires events with
occurrence frequency of <10-5
per year to be considered as
BDBA?
61 Pakistan Article Annex 14 Can Canada clarify why the Point Lepreau includes internal hazards, fire and flood in
14.1 (i)b , Page scope of PSAs of nuclear the PSA work. This is stated on page 231 of the Canadian
230 power plants at Bruce A and B, National Report.
Point Lepreau and Gentilly-2
does not include internal The PSAs for the Bruce A, B Point Lepreau and Gentilly-2
hazards (internal fires, internal stations do include internal flooding however; the PSAs for
floods etc) PSA. all Canadian facilities are being (or have been) updated to
meet the requirements CNSC Regulatory Standard S-294
Probabilistic Safety Assessment (PSA) for Nuclear Power
Plants.
Original Reference in
Ser Country Question/Comment Response
Reference Report
positive step. Is there any plan (Pickering), we do not foresee installation of on-line risk
to use PSA for online risk monitors in the main control room environment, but rather
monitoring for other NPPs in see the use of such tools in maintenance planning activities
Canada. Moreover, please and the like.
explain whether PSA model is
used with some specific Risk monitoring tools are implemented based on the PSA
changes for online risk with minimal changes to equipment modelling.
monitoring or used as it is.
63 Pakistan Article Annex 14 (i) Severe accidents are not shown A typical safety analysis report for an existing Canadian
14.1 a, Page 229 in the list. NPP does not include a specific section devoted to the
analysis of severe accidents. This analysis is conducted as
part of the Integrated Safety Review to decie on the scope
of refurbishment activity. However, the CNSC expects
severe accidents to be addressed in Level 2 PSA. When the
regulatory document RD-310 is adopted for existing NPPs,
its expectations with respect to severe accidents will be
required to be addressed in the safety analysis reports.
64 Ukraine Article Para 14.i Do you use Risk Monitors in The RIDM process does not use risk monitors. The process
14.1 Page 113 the RIDM process? uses risk notices to assess the overall additional risk posed
by an issue.
65 United Arab Article 112 The CNS National Report None of these initiatives resulted in the creation of new
Emirates 14.1 reports that three other requirements, per se, for any licensee. However, they have
regulatory initiatives helped clarify the requirements already in place.
licensing basis definition,
reformed licence, and licence Clarifying the definition of the licensing basis has helped to
condition handbook have distinctly identify the boundaries of the information on
helped improve the clarity of which the decision to licence a facility (in the past, present,
requirements and expectations or future) is based). The reformed licence and licence
for NPP licensees, and have condition handbook simply represent a restructuring and
also facilitated increased clarification of the information and requirements that were
regulatory efficiency and previously in all licences. In the current reporting period, it
effectiveness. Are these new is planned that all NPP operating licences will be replaced
requirements that did not have by a licence in the new format and a corresponding licence
to be met by previously condition handbook. These changes, in themselves, will not
44
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
licensed reactors? Will existing introduce new requirements. However, the new licence
NPPs be required to address contains generic licence conditions that refer to licensee
these new criteria (backfit)? program and references either a regulatory document or an
industry standard. In this way eight new standards were
introduced for the re-licensing of Bruce A and B reactors.
66 United Arab Article 112 In 2008, the CNSC document, Yes, RD-360 would be a useful reference for periodic safety
Emirates 14.1 Design of New Nuclear Power reviews (PSR) in Canada.
Plants (RD-337), was issued to
set out technology-neutral If Canada adopts PSRs, they will be conducted in the same
expectations for the design of way as integrated safety reviews (ISR) for life extension
new water-cooled NPPs. To a projects. The requirements for ISRs are described in CNSC
large degree, RD-337 document RD-360, which states that ISR includes a review
represents the CNSCs against modern standards and practices to assess the level of
adoption of the tenets in IAEA safety compared to that of modern NPPs. Modern standards
document Safety of Nuclear are those documents that define the set of high-level
Plants: Design (NS-R-1), and objectives and requirements for the siting, design,
the adaptation of those tenets construction, commissioning, operation and
to align with Canadian decommissioning of an NPP if it were to be built at the time
practices. Does the CNSC of the initiation of the life extension project. Clearly, RD
believe that this document 337 is such a document, and hence it is already being used
would be a useful reference for as a reference in an PSR.
Periodic Safety Reviews in
Canada?
67 United Arab Article 112 The IAEA Integrated An important factor in the success of the IRRS mission to
Emirates 14.1 Regulatory Review Mission Canada was the commitment, from the outset, of high-level
(IRRS) in 2009 reported that it CNSC management to all the arrangements and inputs that
was impressed with the were necessary. This commitment, and the importance of
extensive preparation of all the mission, was well communicated to all levels of
CNSC staff. What advice management and staff.
could CNSC provide to FANR
with regard to requesting and Prior to the IRRS mission, the CNSC developed the
scheduling an IAEA IRRS Harmonized Plan of Improvement Initiatives (HP) to
Mission to UAE, and taking consolidate responses to lessons learned from previous
the necessary steps to be audits and assessments. Consolidating the understanding of
45
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
prepared for the visit to make strengths and weaknesses, before the mission, is very
it as effective as it seems to important. During the mission, the CNSC provided input
have been in Canada? and feedback to the review team to ensure that the output
(e.g., the recommendations and suggestions) was organized
and detailed in such as way as to easily facilitate further
constructive efforts to improve. The HP was also developed
as a flexible, evergreen mechanism. When the IRRS
mission identified new issues or clarified CNSCs
understanding of other issues, it was relatively easy to
address any needed improvement efforts in the context of
the HP, thus ensuring the relevant initiative received the
appropriate priority and resources in the context of overall
CNSC operations.
Original Reference in
Ser Country Question/Comment Response
Reference Report
14(ii) e page 127). Are these
this can be done only with the prior written approval of the
requirements prescriptive or
Commission, or of a person authorized by the
non prescriptive? Could you
Commission. The basis for the judgement under which
give an example of such
this approval may be given is non-prescriptive, largely
verification related to a
because we do not expect such deviations to be requested,
proposed modification?
so any approval will be expert-based, not rule-based. The
basis for judgement is provided through the RIDM process,
used for example, in the Pickering B road based
guararanteed shut-down state (RBGSS).
69 India Article 14(ii)e Page It is stated that safety review of Regular regulatory review of the safety analysis report
14.2 127, 18(ii) the NPP is carried out at the (currently every three years) is necessary to provide
Page 155, Ap time of license renewal (i.e. at adequate oversight of analysis methodologies, computer
five years). The review of codes, etc. The licence period for an NPP in Canada,
safety systems reliability and although typically five years, has ranged from two to five
safety analysis report is carried years (and could exceed five years if periodic safety review
out at a frequency that is is adopted). At the time of licence renewal, the safety
higher than the plant safety analysis report is part of the information submitted by the
review at the time of license applicant and is reviewed by the CNSC. However, a
renewal. Please explain separate review of the updates to the safety analysis report,
reasons for higher frequency of on a regular basis, is needed (independent of the licence
review of safety systems application review, which could happen more or less
reliability and safety analysis frequently).
report, particularly when
design configuration is
reviewed at the time of
renewal of license and also not
much change in analysis
methodologies / computer
codes etc are expected every
three years?
ARTICLE 15: RADIATION PROTECTION
70 Germany Article 15 Page 128, Are dose limits defined for the There are no separate limits that apply specifically to
section 15 a occupational exposure of trainees and students in Canadian regulations. Occupational
trainees and students? dose limits for Nuclear Energy Workers (NEWs) and non
47
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
NEWs are prescribed in CNSCs Radiation Protection
Regulations. A copy is available publicly at
http://laws.justice.gc.ca/PDF/Regulation/S/SOR-2000
203.pdf.
71 Germany Article 15 Page 128, Does Canada intend to change Canada has no immediate plans to change the annual dose
section 15 a the dose limit for a nuclear limit for a nuclear energy worker to 20 mSv. Please note;
energy worker to 20 mSv in a however, that the current 5-year average exposure is 20 Sv
year, consistent with per year.
international standards such as
IAEAs Safety Standards,
Safety Series No. 115?
72 Germany Article 15 Page 131, What is the definition of the Members of the public with the greatest exposure refers to
section 15 c members of the public with individuals that receive the highest doses from a particular
the greatest exposure? source due to factors such as proximity to the release,
dietary and behavioural habits, age and metabolism, and
variations in the environment.
73 India Article 15 15.a Page Section 13 of the Radiation It should be noted that the Radiation Protection Regulations
no.128 (para Protection Regulations in in Canada came into force in 2000 and consultation on this
3, 2nd bullet) Canada requires that every issue was based on the ICRP 60 recommendations.
licensee ensure that the
following effective dose limits A dose limit of 4 mSv was adopted based on an assessment
are not exceeded: 50 mSv in of the risks of detriment to the embryo and foetus. The
a year and 100 mSv over 5 following key points led to the decision to deviate from
years for a nuclear energy ICRPs recommendation:
worker 4 mSv for a pregnant - The risk to the embryo and feotus associated with a
nuclear energy worker for the dose of 4 mSv to the mother is very small
balance of pregnancy 1 mSv - During consultations leading to the adoption of the
per year for a person who is new limit, workers affected by it indicated that the
not a nuclear energy worker risk implications were acceptable
(public) Radiation dose limit - Adoption of the ICRP 60 recommendation (2mSv)
prescribed for a pregnant could lead to discrimination against women because
nuclear energy worker (4 mSv) some employers might conclude that the only
in Canada is higher than the effective method of compliance with the very low
corresponding ICRP dose limit dose limit would be to remove a pregnant worker
48
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
of 1 mSv. Can Canada clarify from work with radiation, or would not hire women
the reasons for this? at all.
Original Reference in
Ser Country Question/Comment Response
Reference Report
dose limit for the embryo/fetus
in the CNSC Radiation
Protecion Regulations? If yes,
what is the dose limit?
ARTICLE 16: EMERGENCY PREPAREDNESS
76 Germany Article p. 138 Can you please comment on In Canada, the provincial emergency organization in
16.1 the different types of consultation with the Nuclear Power Plant (NPP) Operator
emergency planning zones and the regulator will set emergency planning zones (EPZ)
implemented in Canada based on studies and research for potential severe accidents.
including their area? For example, in Ontario, NPPs have a zone immediately
surrounding the boundary of the nuclear installation called
the "contiguous zone" and its radius is approximately 3 km.
The "primary zone" has a radius of approximately 10 km
and it includes the "contiguous zone". The "secondary
zone" is a larger zone used to plan and prepare against
possible exposure resulting from the ingestion of
radioactive material. It has a radius of approximately 50
km.
Original Reference in
Ser Country Question/Comment Response
Reference Report
information for emergency facilitys emergency planning zone (EPZ) expands across
planning and response. It is the border into the neighboring state. There are organized
noted that Canada collaborates scheduled meetings involving local, provincial and state
closely with the USA on officials as well as experts from the major nuclear facility to
emergency response plans; provide advice and updates to the existing contingency
what types of data/information plans.
on Canadian nuclear plants has
Canada shared with its
neighbours to allow them to
develop appropriate
emergency plans?
Korea, Article Emergency Explain the evaluation system Full scale exercises are usually coordinated by the
Republic of 16.1 Preparedness of emergency exercise 1. In Provincial Emergency Management Organization. All
case of a full scale exercise, intervening parties from all levels of government including
(i.e., when off-site institutions the Licensee will meet on a regular basis to design and
participate in the exercise - for develop the master scenario and events listing. The off-site
example, local government, evaluation component is done primarily by a team from the
regulatory bodies, emergency province.
first responders, etc.): a. Who
evaluates the regulatory body The CNSC has an interest in conducting its own off-site
and local government? b. Is evaluation which may involve Licensee personnel. The
there any kind of objective CNSCs main responsibility is to evaluate the Operators
evaluation criteria, including a (on-site) performance during such an exercise. The CNSC
check list? If so, explain and evaluators follow specific guidelines or criteria that are
describe in detail. c. Are there already in place.
any subjective evaluation
criteria? If so, explain and As for evaluating the federal regulatory body, criteria in the
describe in detail. d. Who form of checklists exist to assist evaluators. The criteria are
prepares the exercise scenario? based on specific prescriptive objectives which are derived
from the CNSC Emergency Response Plan. Evaluators can
be consultants who are hired for the job or they can be
employees from within the CNSC. In either case, an after
action report is produced and contains recommendations
and lessons learned etc.
51
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
78 United Arab Article 134 What is the public alerting In Canada public alerting systems will vary from one
Emirates 16.1 system? Licensee to the other. Some facilities will use sirens and
web based systems for informing individuals. Others will
use more conventional systems such as community
notification systems involving a warden service, first
responders and a broadcast media for the population living
in the emergency planning zones (EPZ).
79 United Arab Article 134 Are any instructional messages Yes, the public alerting system works with automatic
Emirates 16.1 sent over social mediums, such telephone dialing systems, cellular phones, pagers and some
as the Internet? include email messages.
80 United Arab Article 134 Is it possible to obtain a copy The Provincial Nuclear Emergency Response Plan
Emirates 16.1 of a Provincial (i.e. Ontario) (PNERP) is the Master Plan. It is a Cabinet (Government of
Nuclear Emergency Response Canada) approved document. It sets out the principles,
and Preparedness Plan? concepts, organization, responsibilities, policies, functions
and interrelationships to take charge of any nuclear and
radiological emergencies in the Province of Ontario.
81 United States Article 16,1e, p 137 (1) What is the frequency for The frequency of conducting emergency exercises at the
of America 16.1 conducting emergency nuclear power plants is defined in CNSC regulatory
exercises at the nuclear power document RD-353 Testing the Implementation of
plants? (2) How often do Emergency Measures, section 4.4 which states, Licensees
exercises involve other federal are directly responsible for training and exercising their
departments to evaluate personnel, and for appointing qualified personnel to their
national response? emergency teams. A schedule for both emergency drills
and emergency exercises should be established every year
to ensure that all responders, including alternates, have the
opportunity to practice the required skills on a regular basis.
All emergency exercise objectives contained in Section 5 of
the document should be brought into play over a five-year
period, with a full scale emergency exercise every three
years.
Original Reference in
Ser Country Question/Comment Response
Reference Report
Departments and Agencies, as listed under the Federal
Nuclear Emergency Plan are set by Health Canada and
Public Safety Canada and are based on risk and priorities.
An exercise of a major component is normally held every
two years at selected sites.
82 Germany Article Page 139 The public alerting system for In the Province of Ontario, NPPs are expanding their public
16.2 NPPs in Ontario is stated to be alerting systems to cover their emergency primary zones of
expanded to the primary zone 10 km. As for NPPs in the Province of New Brunswick and
(10 km). What is the situation Qubec, their emergency primary zones are 20 km and 7 km
for the other NPPs? respectively. These zone limits were based on various
studies conducted for CANDU single unit stations and the
actual population living in the vicinity of the plants.
83 Ireland Article Page 140 The report notes that The Convention on Assistance in the Case of Nuclear
16.2 ratification of the Assistance Accident or Radiological Emergency was signed by Canada
Convention is pending a in December 1986 and subsequently ratified by Parliament
review of domestic in August 2002.
implementing legislation;
when is it anticipated that this
review will be completed?
ARTICLE 17: SITING
84 Germany Article 17(i), Page In the draft guide for the The effects of climate change on the frequency and intensity
17.1 145; 17 (iii), application for a license to of extreme events have been widely recognized, and they
Page 148 prepare a site (c.f. 17 (i)) as have been undergoing extensive studies world-wide. There
well as in the framework of are still considerable uncertainties on the results and
reevaluations (c.f. 17 (iii) a)) methodologies. Nevertheless in engineering practice, they
the consideration of climate have been taken into account through the use of additional
change effects is mentioned. Is safety margins in important designs. CNSC considers it
there a sound scientific basis necessary and practical to have a bounding analysis of the
(i.e. data and methods) for a climate change effects in the new builds designs.
quantitative assessment of
climate change effects on the The assessment of climate change, for example as
frequency and intensity of rare performed for the New Nuclear Project at Darlington, uses
events? climate change predictions that have been developed by
53
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
Environment Canada, the International Panel on Climate
Change, and Natural Resources Canada. The studies
referenced include historical information as well as
predictions of continuing future trends in the specific area
being assessed; the Great Lakes Basin.
Original Reference in
Ser Country Question/Comment Response
Reference Report
prepare a site for a new NPP in Such Safety Goal Based (SGB) releases are expected to
Canada do not require a bound the releases from any credible accidents (i.e., within
proponent to select a specific 10-6/yr) for any of the reactor designs considered, should
design. However, the they become licensed in Canada.
consequences of postulated
accident in the selected design A core radionuclide inventory was selected from one of the
type should be within the reactor technologies considered, based on factors such as
approved EA. In view of this maximum reactor core size and maximum fuel burnup rate.
information i) How source A baseline release, the amounts of each radioisotope
term is selected for EA, released, was then determined based on the release fractions
particularly when it is also associated with a selected accident scenario from the safety
stated that for this assessment analysis of that reactor design (a severe accident involving
accidents having frequency damage to the reactor fuel, that was a high contributor to the
upto 10-06 per year are large release frequency).
considered, which is design
specific? ii) Up to what The SGB releases were then derived by adjusting the
distance EA is carried out as baseline release using scaling factors to reflect the RD-337
part of license for site SRF and LRF threshold release values, as follows:
Original Reference in
Ser Country Question/Comment Response
Reference Report
expected to be conducted.
86 India Article 17(i), Page In RD 346 and as part of For severe weather, flood or wind the return periods are not
17.1 145 license for site i) What are the prescribed; however, the applicant is expected to propose
return periods considered for adequate periods based on criteria identified in IAEA
severe weather/ flood/ wind for documents referenced in RD-346 Site Evaluation for New
deciding site grade elevation? Nuclear Power Plants, for example Safety Guide No NS-G
ii) Are there any guidelines for 3.4 and Safety Standards NS-G-1.5, NS-G-3.2, NS-G-3.4,
accounting for climate change NS-G-3.5.
during the design life/
extended operation? For new builds, the environmental assessment performed at
the beginning of the project requires the proponent to
consider climate change in areas such as external events,
and effects of the plant on the environment over the
projected lifespan of the project. The request by a licensee
to undertake a plant life extension project triggers an
environmental process which will examine the potential
environmental impacts of the undertaking. The effects of
climate change on the extended life are generally examined
as part of the process and would be reflected in the
Integrated Safety Review case put forward by the licensee
in their licensing proposal.
87 Korea, Article p.145 In Section 17 (i) Evaluation Intentional or unintentional aircraft crash is not explicitly
Republic of 17.1 of Site-Related Factors, it is prescribed in Canadian regulations; however, for new build
stated that flight paths for expectations are described in two regulatory documents:
major airports could be one of
the review items to check - RD-346 guides a proponent to perform a Site
possibility of airplane crashes. Selection Threat Risk Assessment which, as part of
Do you have any regulatory the investigation, examines threats due to aircraft.
requirements considering the This information would feed into the site suitability
intentional aircraft impact to decision as well as the plant design process.
NPPs after the 9/11 attack? If
yes, what is the detailed - RD-337 requires an proponent to ensure the design
regulatory requirements for the considers all natural and human-induced external
intentional aircraft impact? events that may be linked with significant
56
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
radiological risk. This includes potential aircraft
crashes, intentional or accidental.
88 United Arab Article 142 Based on Canadas CNS For new NPPs in Canada, the reactor designs considered are
Emirates 17.1 National Report, it is not limited to CANDUs. For instance, in its Environmental
understood that site evaluation Assessment (EA) and Application for a License to Prepare
in Canada is a regulated Site for a new NPP at Darlington, OPG has followed a
activity and is conducted using multi-technology approach in considering various reactor
NPP bounding design technologies, including non-CANDU designs. Specifically,
parameters to assess for the proposed Darlington new NPP, a Plant Parameter
environmental impacts and site Envelope (PPE) approach has been followed (similar to the
suitability and to determine a US-based PPE approach) encompassing the following
site envelop to which a range reactor designs: the AP1000 by Westinghouse; EPR by
of reactor designs can be Areva; ACR-1000 by AECL; and the Enhanced CANDU-6
compared. Since the reactor by AECL. This PPE has been used as part of a bounding
design of choice in Canada is framework for the EA and site evaluation studies of the
the CANDU design, can the proposed Darlington new NPP. Given the variety of reactor
value of using the bounding technologies taken into consideration, the value of the
approach for siting ever be bounding approach has indeed been realized through the
realized? Is Canada robustness of the performed EA and site evaluation studies.
considering using a non-
CANDU reactor technology?
89 United Arab Article 142 With respect to the application The new build site next to the existing Darlington site is
Emirates 17.1 for a licence to prepare the site considered to be a separate site per RD-346. As a result,
for a new-build project CNSC conducts its reviews of the EA, EIS and license
proposed for the Darlington application anew for the new build plant. However, the
site in Ontario, it would appear applicant has the advantage of existing data as well as any
that the new reactors location new data from investigations of the site and the surrounding
would be evaluated against the region. This data is used to support the applicants
identical parameters used for licensing case for the Licence to Prepare Site and in the
the site envelop to locate Environmental Impact Statement where the applicant
existing reactors at that same demonstrates it meets the Environmental Impact Statement
site. Could this site preparation Guidelines specific to the project.
license be granted more or less
57
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
by inspection, since it would
be a similar reactor design at
the same site; only with the
addition of one more source
term? or would CNSC conduct
its reviews of the EA, EIS and
license application anew?
90 China Article 14.(@), 114 What considerations have been The Nuclear Safety and Control Act (NSCA) requires that
17.2 made regarding public before the Commission makes a licensing decision, it must
participation during NPP give the applicant / licensee an opportunity to be heard. In
siting? the interest of fair play, the Commission must give the
person most affected by the decision the opportunity to
present their views to it before making its decision. With
respect to certain decisions made by the Commission, the
NSCA imposes an added obligation to hold a public
hearing. Before making a licensing decision under
subsection 24(2) (major nuclear facilities, including NPP
siting, construction and operation) or where it would be in
the public interest to do so, the Commission must hold a
public hearing. A public hearing is a hearing structured so
as to give affected parties and in most cases interested
members of the public a reasonable opportunity to make
submissions in relation to the matter to be decided by the
Commission. Public hearings are a highly visible
component of the work of the Commission.
Original Reference in
Ser Country Question/Comment Response
Reference Report
facility is located. The notice supplies information on the
duration of the hearing (one or two days), its purpose, dates,
time, place and the deadlines for filing documents prior to
the hearing.
Original Reference in
Ser Country Question/Comment Response
Reference Report
NSCA, is that all proceedings before the Commission shall
be dealt with as informally and expeditiously as the
circumstances and considerations of fairness permit.
Original Reference in
Ser Country Question/Comment Response
Reference Report
modification of the 37-element increases coolant flow past the inner surfaces of the inner
fuel bundle design is ring element sheaths. This small change in bundle
mentioned. Please, could you geometry results in a more balanced distribution of dry-out
give us more details of the margins throughout the modified fuel bundle elements and
reasons and the features of this increases the dry-out power of the modified bundle when
modification? compared to the current design.
Original Reference in
Ser Country Question/Comment Response
Reference Report
RD-337 and other documents. Means of shutdown
Please provide, the 16 specific Fuel design
topical areas covered and how ECCS and emergency feedwater system
do they cover the content and Reactor control system
intent of RD-337 and other Containment
documents. What are the Pressure-boundary design provisions for the PHTS
typical time frames for each
Severe Accident prevention and mitigation
phase of review?
Fire protection
Radiation protection
QA program
Human factors
Out-of-core criticality
Robustness, safeguards and security
Safety analysis
Original Reference in
Ser Country Question/Comment Response
Reference Report
terms of the I131 release that would require temporary
evacuation to mitigate health effects. To achieve a balance
between prevention and mitigation, a third goal is defined to
limit the frequency of Severe Core Damage. This ensures
that the designer does not place too much reliance on the
reactor containment.
96 United States Article 18, p 152 The report references an Since inception of the optional pre-project design review
of America 18.1 optional process for vendors to process for vendors, two have taken advantage of the
obtain CNSC pre-project process:
design reviews and states that
the conclusions of these Atomic Energy of Canada Limited (AECL)
reviews are non-binding and the ACR-1000 completed Phase 1, 2, and 3 as of
typically provided to the January 2011
vendor in a confidential report. the EC-6 design completed Phase 1 in March 2010 and
How often is this optional Phase 2 is currently in progress
process used?
Westinghouse, the AP-1000 design completed Phase 1 in
February 2010.
97 Argentina Article Section 18 Related to the criteria and An example where the design and construction of all
18.2 (ii) Page provisions for incorporation of components, systems and structures follow a best applicable
155 proven technologies in existing code or standard is the pressure-retaining systems and
NPPs (Article 18 - section 18 components standard, CSA N285.0 General requirements
(ii) page 155) it is mentioned for pressure-retaining systems and components in CANDU
that the CANDU design nuclear power plants. The Canadian regulatory practice is
criteria and requirements as follows:
include design and
construction of all 1. The licensee or an agent of the licensee prepares the
components, systems and design of a pressure-retaining system, structure or
structures to follow the best component, and proposes a code classification in
63
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
applicable code, standard or accordance with the rules in CSA N285.0.
practice and be confirmed by a
system of independent audit. 2. The licensee submits an application to the CNSC to
Could you give us information obtain approval of the code classification.
about the system of
independent audit utilized? 3. CNSC staff reviews that application and the design
information submitted in support of the application,
and if deemed to meet the requirements in the Nuclear
Safety and Control Act and its Regulations, approves
the code classification for the system, structure or
component.
Original Reference in
Ser Country Question/Comment Response
Reference Report
CNSC expects that the computer programs have been
validated in accordance with CSA N286.7 Quality
Assurance of Analytical, Scientific and Design Computer
Programs for Nuclear Power Plants. CNSC staff reviews
the submissions from the licensees, and conducts
compliance verification activities, i.e., inspections and
audits, on the licensees implementation of CSA N286.7.
98 Argentina Article Section 18 The report says that an The qualification program used is non-prescriptive in
18.2 (ii) Page adequate qualification program nature; and depends on the SSC being addressed. In view
156 is established to verify that the of the CNSCs performance-based approach, the applicant
new design meets all does have to demonstrate that the SSC will meet the
applicable safety expectations ( requirements of RD-337 Design for New Nuclear Plants,
Article 18 - section 18 (ii) and the expectations listed in RD/GD-369 Licence
page 156). Could you provide Application Guide: Licence to Construct a Nuclear Power
information about the content Plant for the SSC.
and features of the
qualification program used?
99 Belgium Article E, 15 Which kind of question should No response required. Not a question.
18.3 be submitted?
ARTICLE 19: OPERATION
100 United Article Page 160 Your report on the regulatory Licensing commissioning control points are regulatory hold
Kingdom 19.1 oversight of the points, requiring prior authorization by the Commission or a
commissioning activity person authorized by the Commission to proceed further in
mentions Commissioning the commissioning program.
control points (CCPs), non-
licensing CCPs and licensing Non-licensing CCPs are CNSC witness points, as observed
CCPs.. The distinction is not by CNSC staff.
clear, can Canada please
expand? Canada is requested All applicable non-licensing CCPs must be satisfactorily
to provide more detail on the completed as part of obtaining the release from licensing
following; - at a CCP, is a CCPs. Plant management is expected to have appropriate
review of the test results control of all CCPs.
completed before continuing?
If so, does the review enable a Test results are reviewed by the CNSC prior to release of
65
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
judgement to be made on the CCPs and proceeding with the commissioning program.
whether the commissioning
programme should continue, The review does enable a judgement to be made on whether
and whether the succeeding the commissioning program should continue. The CNSC
stages should be modified as a may request modification to succeeding stages as a
consequence of the test results consequence of the test results.
or because some tests in the
stage had not been undertaken
or had not been completed? - It is the responsibility of the licensee to submit a
Are commissioning tests comprehensive commissioning program that defines the
designed to be of sufficient tests to be performed, complete with acceptance criteria.
duration to allow the systems CNSC staff assesses compliance with the licensees
and components under test to program, taking into consideration the characteristics to be
reach their normal equilibrium inspected or tested, as well as the relevance of the tests to
conditions, and provide the proposed operational limits and conditions. The CNSC
enough duty hours to reduce will have site inspectors present at the facility and subject
the probability of failure in the matter experts as appropriate.
early stages of operation?
Please provide a description of Following the suspension of the Darlington New Build
the management structure for project in June 2009, the management structure for
commissioning. Please provide commissioning was disbanded. As a result, plans have not
more information on yet been established for detailed commissioning activities
regulatory oversight of each of for the new build project.
the above features.
The role of the CNSC is to review and assess selected
commissioning activities performed by the licensee and
ensure they meet defined acceptance criteria as well as all
pertinent regulatory and licensing requirements. Existing
governance requires the development of detailed
commissioning specifications to demonstrate that applicable
design, licensing and operational requirements are met.
101 China Article 19.(), 161 What is the essential difference The SOE defines a complete and comprehensive set of
19.2 between the limited condition limits derived from the Safety Analysis through controlled
of operation determined by processes, while the OP&P present only a subset of those
66
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
safe operating envelope project limits. For stations that are far advanced with their SOE
and the specifications in the projects, the SOE limits have been checked against OP&P
OP&P being used limits. Only minor discrepancies have been found to date.
presentlyWill the limited
condition of operation values Full implementation of the SOE project is not expected to
have a great many lead to significant changes to limits that are currently listed
modifications after the safe in the OP&P.
operating envelope project
102 India Article 19(iv) Pg With regard to the plant In Canada, all organizational aspects and criteria for
19.4 166,167, specific SAMGs, it is implementation of off-site protection measures for
Annex 19(iv) mentioned (Page-166) that population in the vicinity of a NPP fall within the
Pg 271 The measures to be responsibilities of the local authorities (i.e., the Provincial
implemented differ somewhat government) and differ from one Province to another. The
depending on the location and differences in the type of criteria triggering off-site
nature of NPP. Please explain protection measures may induce differences in the data
the aspects of SAMGs aquisition (i.e. measurements) and processing (i.e.
considered which depend on computational aids) in SAM. These differences are
location of NPP? reflected in the communications between the plant-specific
SAM organization and the authorities responsible for the
off-site management of the emergency.
103 India Article Annex 19(iv) It is mentioned that The scope of the validation exercise, conducted in 2009,
19.4 Page 272 implementation of key was the response to a major simulated event which will
elements of SAMG require entry into the Bruce Power Severe Accident
programme is in process for Management Guides (SAMG). Involvement was limited to
Bruce-A, which involves those Site Management Centre members including the
minor design changes also. It Technical Support and MCR / EOC who would be directly
is also mentioned that a involved in SAMG only. Other emergency response groups
validation exercise is and contacts, including some SMC members, were
completed in 2009. Please simulated or role-played as necessary to support the
explain i) What was the scope exercise. The scenarios and extents of play were designed
of this validation exercise? ii) to allow actual or simulated demonstration of activities
What is the acceptance criteria supporting the SAMG.
put forth by CNSC for these
validation exercises? iii) What There were no CNSC acceptance criteria for this validation
67
Fifth Review Meeting Responses to Questions to Canada
Original Reference in
Ser Country Question/Comment Response
Reference Report
design changes were involved exercise; however, the exercise was designed to meet CNSC
in implementing the SAMGs? expectations as defined in CNSC Regulatory Guide G-306
Severe Accident Management Programs for Nuclear
Reactors.
Original Reference in
Ser Country Question/Comment Response
Reference Report
procedures or expert type of events which should be investigated independently
judgement. Please explain the by Regulatory Staff is available. Procedural guidance on
difference in the regulatory the conduct of the different types of regulatory
activities according to the investigations is also available. The methodology used by
significance of events. Regulatory Staff during the conduct of these regulatory
investigations is based on TapRoot, a patented individual
and enterprise software designed to streamline and organize
the incident investigation.
106 Germany Article Page 167 After the event in the NPP A major difference between Pickering B and other NPPs in
19.7 Pickering of August 2003 a Canada was that Pickering B could not be cooled down
new auxiliary power system without Class IV power (i.e. the Class III service water
was installed. Do the other system could not provide suffcient cooling water to the
Canadian NPPs have such a shutdown cooling system to cool down the reactor). The
power station or are there any new Auxiliary Power Supply that was installed has
retrofit measures? Are there sufficient power to run the Class IV service water pumps to
Canadian requirements with allow cool down of the reactor in event of a loss of grid. At
regard to auxiliary power all other NPPs in Canada, the reactors can be cooled down
systems? using Class III power so there is no need for an APS.
107 Pakistan Article Appendix Does the Canadian industry Canadian plants that are undergoing or planning
19.7 E.2, Page follow the concept of sustained refurbishment must comply with RD-337 to the extent
184 steam flow critical/trace practicable. In LOCA and LOECCS with a trace flow, the
flow for hydrogen production hydrogen and radio-nuclide source terms experience step
assessment in case of LOCA increases and thus represent a specific challenge to the
with loss of ECCS? containment function. The accident needs therefore to be
addressed in the design of the containment mitigating
measures. However, in the framework of RD-337, this
accident could be classified as a Beyond Design Basis
Accident (BDBA) and realistic analysis and relaxed design
rules could be applied.
Original Reference in
Ser Country Question/Comment Response
Reference Report
108 France Article 2 - p171 "Could Canada provide details In Canada, all spent fuel (high-level waste) from nuclear
19.8 about the management of high power plants is stored in interim storage at the site where it
level radioactive waste was produced. When the fuel first exits a power reactor, it
produced by NPPs? Are the is placed in water-filled bays. Water cools the fuel and
waste stored on site like other shields the radiation. After several years in the bays six to
nuclear waste or have 10 years, depending on site-specific needs and
dedicated interim storages?" organizational administrative controls and when the
associated heat generation has diminished, the spent fuel
can be transferred to an onsite interim dry storage facility.
Original Reference in
Ser Country Question/Comment Response
Reference Report
expected that the appointment of the joint review panel
(JRP) will be announced in January 2011. The JRP will
assess the environmental assessment and the first stages of
licensing.
71