BEAM REINFORCEMENT CALCULATION

Beam CB2

C/C span of slab panel (in meters) :


LENGTH, L = 3.00

Effective span of slab panel, L (in meters) :-


LENGTH, Ly= 3.00

Assuming depth of slab as (in mm)= 150

Self weight of slab (in KN/sqm) 3.75


6 mm Plaster (in KN/sqm) 0.250
50 mm of floor finishing (in KN/sqm) 1.500
Live load on slab (in KN/sqm) 4.000
Sunk load --- if any (in KN/sqm) 0.000
Partition Wall Load (in KN/sqm) 0.000
Total load, w (in KN/sqm) 9.5
TOTAL LOAD, W'= ( w) (in KN/sqm) 9.500

BEAM SHOULD BE DESIGN FOR LOAD ACTING OVER EFFECTIVE AREA, A


WHERE, A =
.'. A = 11.25 fy= 415
fck= 20
LOAD ON BEAM W = (W' x A) = 35.63 KN/M
SELF WEIGHT BEAM = 3.1625 KN/M Xu/d= 0.479107
WALL LOAD = 5.06 KN/M
.'. TOTAL UDL ON BEAM, (W) 43.85 KN/M
POINT LOAD = 0 KN
POINT LOAD MOMENT, Mp = 0 KNM
MOMENT DUE TO UDL, M = 197.31 KNM

Mu(limit) = 166.86 Kn-M


FACTORED MOMENT, Mu = 295.97 KN-M
Mua = (Mu-Mu(limit)) = 129.11 KN-M
AND,
BREADTH OF BEAM, b = 230 mm
OVERALL DEPTH OF BEAM, D = 550 mm
EFFECTIVE COVER, d' = 37.5 mm
DEPTH OF BEAM, d = 512.5 mm
LENGTH OF BEAM, L = 3000 mm
MU /Bd2 = 4.90 N/mm2
d'/d = 0.07 RATIO
DOUBLY REIN.
IF= REQUIRED AREA OF STEEL
Mu(limit) Total
=0.87*fy* As2=Mua/{ tensile
Ast1*d*{ (0.87*fy)*( Area(Ast)
THEN 1- d-d')} mm
1126.21 752.85 1879
TENSILE STEEL
COMPRESSION
799.44 799
STEEL

PROVIDED AREA OF TENSILE STEEL


OF STEEL area of 1 bar no.of total area
25 490.625 2 981.25
20 314 3 942.00
16 201 0 0.00
12 113 0 0
Total 1923.25
SHEAR CHECK
SHEAR FORCE, V = (W x L)/2 = 65.77125 KN
FACTORED SHEAR FORCE, VU = (1.5 Xv) = 98.656875 KN
tv = VU / (b x d)
100As/bd= 1.59
2
NOMINAL SHEAR STRESS, tv = 0.84 N/mm
FROM IS-456, TABLE- 23, PAGE No. 85(84)
2
PERMISSIBLE SHEAR STRESS, tC = 2 N/mm
CHECK FOR DEFLECTION
% age = 1.63
Fs = 235
mf1 = 0.90
L/D = 25.65
REQUIRED, d = 97
PROVIDED, d = 513
SAFE = BEAM SAFE