You are on page 1of 4

[1] A. A. Pereira da Silva and J. M.

de Barros Bezerra, A Model for Uprating


Transmission Lines by Using HTLS Conductors, IEEE Transactions on Power
Delivery, vol. 26, no. 4, Oct. 2011.

[2] K. Dave, N. Mohan, X. Deng, R. Gorur, R. Olsen Analyzing Techniques for


Increasing Power Transfer in the Electric Grid, North American Power
Symposium (NAPS), Sept. 2012.

[3] CIGR WG C1/C2/C6.18, Coping with Limits for Very High Penetrations of
Renewable Energy. February 2013.

[4] Antonio Gmez Expsito, Fellow, IEEE, Jess Riquelme Santos, and Pedro
Cruz Romero, Planning and Operational Issues Arising From the Widespread
Use of HTLS Conductors, IEEE Transactions on Power Systems, vol. 22, no. 4,
pp. 1446-1455, November 2007.

[5] Electric Power Substations Engineering, Second Edition, J. D. McDonald,


Taylor & Francis (CRC Press), 2007.

[6] Connector Theory and Application. A Guide to Connection Design and


Specification. G. Di Troia, K. Woo, G. Zahlman, revised 4th ed., Burndy.

[7] A. NEMA, "ANSI / NEMA CC1," Electric Power Connection for Substation,
ed. Rosslyn, Virginia: NEMA, 2009.

[8] IEC 60694 Common specifications for high-voltage switchgear and


controlgear standards, IEC International Standard, 2002.

[9] IEC 61238-1 Compression and mechanical connectors for power cables
with copper or aluminum conductors - Part 1: Test methods and
requirements, IEC International Standard, 2003.

[10] ANSI C119.4 Connectors for use between aluminum to aluminum and
aluminum to cooper conductors designed for normal operation at or below
93 degree C and copper to copper conductors designed for normal operation
at or below 100 degree C., 2011.

[11] Guide for Qualifying High Temperature Conductors for Use on Overhead
Transmission Lines," CIGRE, 2010

[12] "Increasing Capacity of Overhead Transmission Lines Needs and


Solutions," CIGRE, 2010.

[13] High-Temperature, Low-Sag Transmission Conductors, EPRI


Rep.1001811, Jun. 2002.

[14] CIGRE WG B2.12, Conductors for the Uprating of Overhead Lines, Tech.
Brochure 244, 2004.

[15] 1283-2004 - IEEE Guide for Determining the Effects of High


Temperature Operation on Conductors, Connectors, and Accessories, 2005.

[36] M.H. Mulazimoglu, R.A.L. Drew and J.E. Gruzleski: "The Electrical
Conductivity of Cast Al-Si Alloys in the Range 2 to 12.6 Wt. Pet. Silicon."
Metallurgical Transactions A., Vol. 20A, 1989, pp. 383-389.
.

[38] H.E. House, P.D. Tuttle, Current-carrying capacity of ACSR, power


apparatus and systems. Part III Transactions of the American Institute of
Electrical Engineers, 77 (3) (1958), pp. 11691173.

[39] V.T. Morgan, The thermal rating of overhead-line conductors. Part I: The
steady-state thermal model Electric Power Systems Research, 5 (1982), pp.
119139.

[40] The thermal behaviour of overhead conductors. Section 1 and 2:


mathematical model for evaluation of conductor temperature in the steady
state and the application thereof, Electra, 144 (1992), pp. 107125

[41] Calculating the currenttemperature of bare overhead conductors, IEEE


Std 738-2006 (Revision of IEEE Std 738-1993) (2007), pp. c1c59

[42] A.A.P. Silva, J.M.B. Bezerra, Applicability and limitations of ampacity


models for HTLS conductors, Electric Power Systems Research, Volume 93,
December 2012, Pages 61-66.

[43] Buckingham, E., "On physically similar systems; illustrations of the use
of dimensional equations". (1914) Physical Review 4 (4): 345376.

[44] N.P. Schmidt, Comparison between IEEE and CIGRE ampacity standards
IEEE Transactions on Power Delivery, 14, 1999.

[45] Takahashi, T.; Ito, T.; Okamoto, T.; Imajo, T., "Development of calculation
system for transient temperature rise of power cables in protection pipe,"
Transmission and Distribution Conference and Exhibition 2002: Asia Pacific.
IEEE/PES , vol.3, no., pp.1899,1904 vol.3, 6-10 Oct. 2002.

[46] Li Yanmu; Liang Yongchun; Li Yanming; Si Wenrong; Yuan Peng; Li


Junhao, "Coupled Electromagnetic-Thermal Modeling the Temperature
Distribution of XLPE Cable," Power and Energy Engineering Conference,
2009. APPEEC 2009. Asia-Pacific , pp.1,4, 27-31 March 2009.

[47] Jeong-Hoon Yoon; Heui-Sub Ahn; Jongung Choi; Il-Sung Oh, "An
Estimation Technology of Temperature Rise in GIS Bus Bar using Three-
Dimensional Coupled-Field Multiphysics," Electrical Insulation, 2008. ISEI
2008. Conference Record of the 2008 IEEE International Symposium on ,
vol., no., pp.432,436, 9-12 June 2008.

[48] Kay Hameyer, Johan Driesen, Herbert De Gersem and Ronnie Belmans,
"The Classification of Coupled Field Problems," IEEE Transactions on
Magnetics, Vol. 35, No. 3, pp. 1618-1621, 1999.

[49] G. Buonanno, A. Carotenuto, M. Dell'Isola, D. Villacci, "Effect of radiative


and convective heat transfer on thermal transients in power cables," IEE
Proc.-Gener. Transm. Distrib., Vol. 142, pp. 436-444, 1995.

[50] S.W. Kim, H.H. Kim, S.C. Hahn, Member, IEEE, B.Y. Lee, K. Y. Park, Y.J. Shi
n, W.P. Song, J.B. Kim, and I.H. Shin, "Coupled Finite-Element-Analytic
Technique for Prediction of Temperature Rise in Power Apparatus," IEEE
Transactions on Magnetics, Vol. 38, No. 2, pp. 921-924, 2002.
[51] S.W. Churchill, H. Chu, Correlating equations for laminar and turbulent
free convection from a horizontal cylinder, Int. J. Heat Mass Transfer, 18
(1975), pp. 10491053

[52] Joan Hernndez-Guiteras, Jordi-Roger Riba, Lus Romeral, Improved


design of an extra-high-voltage expansion substation connector through
magnetic field analysis, Simulation Modelling Practice and Theory, Volume
43, April 2014.

[53] J. C. Maxwell, A dynamical theory of the electromagnetic field,


Philosophical Transactions of the Royal Society of London, no 155, p. 459
512, 1865.

[54] D. Cheng, Field and Wave Electromagnetics (Second ed.),


Massachusetts, USA: Addison-Wesley, 1991.

[55] 60287-1-1, Electric cables Calculation of current rating Part 1:


Current rating equations (100% load factor) and calculation of losses
Section 1: General, 2006.

[57] F.P. Incropera, D.P. DeWitt, Fundamentals of Heat and Mass Transfer,
fourth ed., John Wiley & Sons, Dearborn, Michigan, USA, 1996.

[58] H.T. Sabarez, Computational modelling of the transport phenomena


occurring during convective drying of prunes, J. Food Eng. 111 (2012) 279
288.

[59] W.H. McAdams, Heat Transmission (second ed.)McGraw-Hill, New York,


1942.

[60] R. Wilkins, T. Saengsuwan, L. OShields, Short-circuit tests on current-


limiting fuses: modelling of the test circuit, Generation, Transmission and
Distribution, IEE Proceedings C, vol. 140, no 1, pp. 30-36, 1993.

[61] J. C. Maxwell, A Treatise on Electricity and Magnetism, Clarendon Press ,


1973 .

[62] P. L. Kalantarov, Inductance Calculations, Moscow: National Power Press,


1955.

[63] H. B. Dwight, Electrical Coils and Conductors, New York : McGraw- Hill
Book Company, 1945.

[64] F. W. Grover, Inductance Calculations, New York, Dover, 1964.

[65] Shinkai, T.; Sakamoto, M.; Suzuki, K.; Toyoda, A study on proximity
effect of current distribution in conductors and improvement of GIS
arrangement, de Electric Power Engineering, Budapest, 1999.

[66] P. Dowell, Effects of eddy currents in transformer windings, Electrical


Engineers, Proceedings of the Institution of, vol. 113, no 8, pp. 1387- 1394,
1966.

[67] A. Ducluzaux, Extra losses caused in high current conductors by skin


and proximity effects."Cahier Technique, n.83", Cahier Technique Schneider
Electric, 1983.
[68] E. Mateescu, D. Marginean, G. Gheorghita, E. Dragan, St. I. A. Gal and
C. Matea, Uprating a 220 kV Double Circuit Transmission LINE in Romania;
Study of the Possible Solutions, Technical and Economic Comparison, Paper
presented at 2009 IEEE Bucharest Power Tech Conference, June 28th - July
2nd, Bucharest.

You might also like