You are on page 1of 2

VERTICAL THRUST-GUIDE BEARING

TECHNICL SPECIFICATION-BH70417015
This specification covers the supply of a vertical combined thrust - guide bearing support, including housing and
instrumentation.
A. Thesupply
This support is equipped
shall include:with device suitable to stand the transient upwards thrust, as specified in the
1 Complete bearing housing YES
2 Cooler YES (SS316 WITH Cu Fins)
3 Heater NO
4 Collar YES
5 Radial and axial Pads YES
6 Upward thrust pads YES
Two Nos RTDs on thrust pads and one RTD on
7 radial pad YES
8 One RTD on Oil bath YES
9 Oil level gauge & Oil level switch YES
One temerature gauage on oil bath (dial type with
10 capillary) YES
Two nos Vibration detectors (threaded holes) on
13 the housing at 90Deg apart PROVISION ONLY
15 Oil drain with Valve and extension pipe YES
16 Test with relevant certification dossier YES
Support drawing with dimensional data and
17 part/material list YES
18 Operation & Maintence Manual YES
19 Auto-cad & 3D-igs/STEP File YES
B. TECHNICAL FEATURES
1 Total Qty
Concrete Volute Pump (Qty
2 :-05 Nos.)
Drive machine CVP
3 Driven machine Electric Motor
4 Coupling Type Universal Shaft
5 Service Continuous
6 Shaft arrangement Vertical
7 Shaft Dia (Under Collar) 210 MM
ST ST ASTMA276-410
8 ANLD
Shaft material
9 Operating speed 330 RPM
10 Reverse Speed (Continues) 610 RPM
Direction of Rotation ( View from Top of Thrust Clockwise (Viewed from top
view)
11 Bearing) Bearing
Should Be Suitable for Both Service of Rotation
12 Thrust PAD type Central Pivot type
13 Continous axial load (DOWN) 524 kN
14 Transient axial load (DOWN) 10 minute 810 kN
15 Static load at speed zero (DOWN) 80 kN
16 Radial load Continus 50 kN
17 Transient Radial load (For 10 minuts) 100 kN
18 Transient load (UP) 30 seconds 80 kN
19 Cooling water temperature (MAX.) 35 C
20 Cooling water type River Water
Supplier shall submit following details after placing
21
of Order
1 Working temperature of thrust pad metal
2 Alarm temperature of thrust pad metal C
3 Trip temperature of thrust pad metal C
4 Working temperature of radial pad metal C
5 Alarm temperature of radial pad metal C
6 Trip emperature of radial pad metal C
7 Working oil temerature C
8 Alarm oil temerature C
9 Trip oil temerature C
10 Oil type
11 Oil quanity Liters
12 Cooling water flow rate Liters/Min
13 Cooling water DELTA temerature C
14 Cooling water DELTA pressure bar
15 Power loss in the bearing KW
D. TEST
Following certifiaction shall be supplied for the test carried out on rach support:
1 Material certifiaction for the main comonents.
2 White metal adhesion test certificate.
3 Cooler hydrostatic test certificate.
4 Housing tightness test certificate.
5 Visaual and dimensional test certificate.

You might also like