Slab geometry
Span of slab in x-direction; Spanx = 7200 mm
Span of slab in y-direction; Spany = 7200 mm
Column dimension in x-direction; lx = 400 mm
Column dimension in y-direction; ly = 400 mm
External column dimension in x-direction; lx1 = 250 mm
External column dimension in y-direction; ly1 = 250 mm
Edge dimension in x-direction; ex = lx1 / 2 = 125 mm
Edge dimension in y-direction; ey = ly1 / 2 = 125 mm
Effective span of internal bay in x direction; Lx = Spanx lx = 6800 mm
Effective span of internal bay in y direction; Ly = Spany ly = 6800 mm
Effective span of end bay in x direction; Lx1 = Spanx lx / 2 = 7000 mm
Effective span of end bay in y direction; Ly1 = Spany ly / 2 = 7000 mm

ex A B C
Span x Span x
ey l y1
1
lx1
lx lx
y
an
Sp

2 ly
y
an
Sp

3 ly

Slab details
Depth of slab; h = 250 mm

1
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

2
Characteristic strength of concrete; fcu = 35 N/mm
2
Characteristic strength of reinforcement; fy = 500 N/mm
2
Characteristic strength of shear reinforcement; fyv = 500 N/mm
Material safety factor; m = 1.15
Cover to bottom reinforcement; c = 20 mm
Cover to top reinforcement; c = 20 mm
Loading details
2
Characteristic dead load; Gk = 7.000 kN/m
2
Characteristic imposed load; Qk = 5.000 kN/m
Dead load factor; G = 1.4
Imposed load factor; Q = 1.6
2
Total ultimate load; Nult = (Gk G) + (Qk Q) = 17.800 kN/m
Moment redistribution ratio; b = 1.0
Ratio of support moments to span moments; i = 1.0

DESIGN SLAB IN THE X-DIRECTION

SAGGING MOMENTS
End bay A-B
Effective span; L = 7000 mm
Depth of reinforcement; d = 200 mm
2 2
Midspan moment; m = (Nult L ) / (2 (1 + (1 + i)) ) = 74.823 kNm/m
Support moment; m = i m = 74.823 kNm/m
Design reinforcement
2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.053
Compression reinforcement is not required
z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 187.3 mm
2
Area of reinforcement designed; As_des = m / (z fy / m) = 919 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 919 mm /m
Provide 20 dia bars @ 150 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 2094 mm /m
PASS - Span reinforcement is OK
Check deflection
2
Design service stress; fs = 2 fy As_req / (3 As_prov b) = 146 N/mm
2 2 2
Modification factor; k1 = min(0.55+(477N/mm -fs)/(120(0.9N/mm +(m/d ))),2) = 1.545
Allowable span to depth ratio; 0.9 26 k1 = 36.151
Actual span to depth ratio; L / d = 35.000

2
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

PASS - Span to depth ratio is OK


Internal bay B-C
Effective span; L = 6800 mm
Depth of reinforcement; d = 202 mm
2 2
Midspan moment; m = (Nult L ) / (2 ((1 + i) + (1 + i)) ) = 51.442 kNm/m
Support moment; m = i m = 51.442 kNm/m
Design reinforcement
2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.036
Compression reinforcement is not required
z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 191.9 mm
2
Area of reinforcement designed; As_des = m / (z fy / m) = 617 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 617 mm /m
Provide 16 dia bars @ 200 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 1005 mm /m
PASS - Span reinforcement is OK
Check deflection
2
Design service stress; fs = 2 fy As_req / (3 As_prov b) = 204 N/mm
2 2 2
Modification factor; k1 = min(0.55+(477N/mm -fs)/(120(0.9N/mm +(m/d ))),2) = 1.601
Allowable span to depth ratio; 0.9 26 k1 = 37.469
Actual span to depth ratio; L / d = 33.663
PASS - Span to depth ratio is OK

HOGGING MOMENTS INTERNAL STRIP


Penultimate column B3
Consider the reinforcement concentrated in half width strip over the support
Depth of reinforcement; d = 200 mm
Support moment; m = 2 i m = 149.646 kNm/m
2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.107
Compression reinforcement is not required
z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 172.5 mm
2
Area of reinforcement required; As_des = m / (z fy / m) = 1996 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 1996 mm /m
Provide 20 dia bars @ 150 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 2094 mm /m
PASS - Support reinforcement is OK

3
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

Internal column C3
Consider the reinforcement concentrated in half width strip over the support
Depth of reinforcement; d = 200 mm
Support moment; m = 2 i m = 102.884 kNm/m
2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.073
Compression reinforcement is not required
z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 182.1 mm
2
Area of reinforcement required; As_des = m / (z fy / m) = 1300 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 1300 mm /m
Provide 20 dia bars @ 200 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 1571 mm /m
PASS - Support reinforcement is OK

HOGGING MOMENTS EXTERNAL STRIP


Penultimate column B1, B2
Consider one and a half bays of negative moment being resisted over the edge and penultimate column
Width of span; B = 7200 mm
Edge distance; e = 125 mm
Depth of reinforcement; d = 200 mm
Support moment; m = m i (e + B + B / 2) / ((0.5 B) + (0.2 B) + e) = 158.265
kNm/m
2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.113
Compression reinforcement is not required
z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 170.5 mm
2
Area of reinforcement required; As_des = m / (z fy / m) = 2134 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 2134 mm /m
Provide 20 dia bars @ 125 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 2513 mm /m
PASS - Support reinforcement is OK
Internal column C1, C2
Consider one and a half bays of negative moment being resisted over the edge and penultimate column
Width of span; B = 7200 mm
Edge distance; e = 125 mm
Depth of reinforcement; d = 200 mm
Support moment; m = m i (e + B + B / 2) / ((0.5 B) + (0.2 B) + e) = 108.810
kNm/m

4
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.078
Compression reinforcement is not required
z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 180.9 mm
2
Area of reinforcement required; As_des = m / (z fy / m) = 1383 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 1383 mm /m
Provide 20 dia bars @ 200 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 1571 mm /m
PASS - Support reinforcement is OK
Corner column A1
Depth of reinforcement; d = 206 mm
Total load on column; S = ((Spanx / 2) + ex) ((Spany / 2) + ey) Nult = 247 kN
2
Area of column head; A = lx ly1 = 0.100 m
1/3
Support moment; m = S (1 (Nult A / S) ) / 2 = 99.639 kNm/m
2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.067
Compression reinforcement is not required
z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 189.3 mm
2
Area of reinforcement required; As_des = m / (z fy / m) = 1211 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 1211 mm /m
Provide 16 dia bars @ 150 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 1340 mm /m
PASS - Support reinforcement is OK
Edge column A2, A3
Depth of reinforcement; d = 202 mm
Total load on column; S = Spanx (Spany / 2 + ey) Nult = 477 kN
2
Area of column head; A = lx1 ly = 0.100 m
1/3
Support moment; m = S (1 (Nult A / S) ) / 5.14 = 78.476 kNm/m
2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.055
Compression reinforcement is not required
z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 188.8 mm
2
Area of reinforcement required; As_des = m / (z fy / m) = 956 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 956 mm /m
Provide 16 dia bars @ 175 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 1149 mm /m

5
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

PASS - Support reinforcement is OK


Between columns 1-2, 2-3
Around the perimeter between the column heads provide a minimum of 50% of the required end span bottom
reinforcement.
2
Area of reinforcement required; As_req = Asx1 / 2 = 1047 mm /m
Provide 16 dia bars @ 150 centres - 'U' bars with 1600 mm long legs
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 1340 mm /m
PASS - Edge reinforcement is OK
Distribution reinforcement
Provide 12 dia bars @ 300 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 377 mm /m

DESIGN SLAB IN THE Y-DIRECTION

SAGGING MOMENTS
End bay 1-2
Effective span; L = 7000 mm
Depth of reinforcement; d = 220 mm
2 2
Midspan moment; m = (Nult L ) / (2 (1 + (1 + i)) ) = 74.823 kNm/m
Support moment; m = i m = 74.823 kNm/m
Design reinforcement
2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.044
Compression reinforcement is not required
z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 208.6 mm
2
Area of reinforcement designed; As_des = m / (z fy / m) = 825 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 825 mm /m
Provide 20 dia bars @ 200 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 1571 mm /m
PASS - Span reinforcement is OK
Check deflection
2
Design service stress; fs = 2 fy As_req / (3 As_prov b) = 175 N/mm
2 2 2
Modification factor; k1 = min(0.55+(477N/mm -fs)/(120(0.9N/mm +(m/d ))),2) = 1.579
Allowable span to depth ratio; 0.9 26 k1 = 36.942
Actual span to depth ratio; L / d = 31.818
PASS - Span to depth ratio is OK
Internal bay 2-3
Effective span; L = 6800 mm

6
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

Depth of reinforcement; d = 222 mm


2 2
Midspan moment; m = (Nult L ) / (2 ((1 + i) + (1 + i)) ) = 51.442 kNm/m
Support moment; m = i m = 51.442 kNm/m
Design reinforcement
2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.030
Compression reinforcement is not required
z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 210.9 mm
2
Area of reinforcement designed; As_des = m / (z fy / m) = 561 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 561 mm /m
Provide 16 dia bars @ 200 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 1005 mm /m
PASS - Span reinforcement is OK
Check deflection
2
Design service stress; fs = 2 fy As_req / (3 As_prov b) = 186 N/mm
2 2 2
Modification factor; k1 = min(0.55+(477N/mm -fs)/(120(0.9N/mm +(m/d ))),2) = 1.798
Allowable span to depth ratio; 0.9 26 k1 = 42.062
Actual span to depth ratio; L / d = 30.631
PASS - Span to depth ratio is OK

HOGGING MOMENTS INTERNAL STRIP


Penultimate column C2
Consider the reinforcement concentrated in half width strip over the support
Depth of reinforcement; d = 220 mm
Support moment; m = 2 i m = 149.646 kNm/m
2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.088
Compression reinforcement is not required
z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 195.7 mm
2
Area of reinforcement required; As_des = m / (z fy / m) = 1758 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 1758 mm /m
Provide 20 dia bars @ 150 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 2094 mm /m
PASS - Support reinforcement is OK
Internal column C3
Consider the reinforcement concentrated in half width strip over the support
Depth of reinforcement; d = 220 mm

7
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

Support moment; m = 2 i m = 102.884 kNm/m


2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.061
Compression reinforcement is not required
z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 204.0 mm
2
Area of reinforcement required; As_des = m / (z fy / m) = 1160 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 1160 mm /m
Provide 20 dia bars @ 200 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 1571 mm /m
PASS - Support reinforcement is OK

HOGGING MOMENTS EXTERNAL STRIP


Penultimate column A2, B2
Consider one and a half bays of negative moment being resisted over the edge and penultimate column
Width of span; B = 7200 mm
Edge distance; e = 125 mm
Depth of reinforcement; d = 220 mm
Support moment; m = m i (e + B + B / 2) / ((0.5 B) + (0.2 B) + e) = 158.265
kNm/m
2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.093
Compression reinforcement is not required
z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 194.1 mm
2
Area of reinforcement required; As_des = m / (z fy / m) = 1875 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 1875 mm /m
Provide 20 dia bars @ 150 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 2094 mm /m
PASS - Support reinforcement is OK
Internal column A3, B3
Consider one and a half bays of negative moment being resisted over the edge and penultimate column
Width of span; B = 7200 mm
Edge distance; e = 125 mm
Depth of reinforcement; d = 220 mm
Support moment; m = m i (e + B + B / 2) / ((0.5 B) + (0.2 B) + e) = 108.810
kNm/m
2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.064

8
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

Compression reinforcement is not required


z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 203.0 mm
2
Area of reinforcement required; As_des = m / (z fy / m) = 1233 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 1233 mm /m
Provide 20 dia bars @ 200 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 1571 mm /m
PASS - Support reinforcement is OK
Edge column B1, C1
Depth of reinforcement; d = 222 mm
Total load on column; S = (Spanx / 2 + ex) Spany Nult = 477 kN
2
Area of column head; A = ly1 lx = 0.100 m
1/3
Support moment; m = S (1 (Nult A / S) ) / 5.14 = 78.476 kNm/m
2
Lever arm; K = 0.402 (b 0.4) 0.18 (b 0.4) = 0.176
2
K = m / (d fcu) = 0.045
Compression reinforcement is not required
z = min((0.5 + (0.25 (K / 0.9))), 0.95) d = 210.1 mm
2
Area of reinforcement required; As_des = m / (z fy / m) = 859 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 859 mm /m
Provide 16 dia bars @ 175 centres
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 1149 mm /m
PASS - Support reinforcement is OK
Between columns A-B, B-C
Around the perimeter between the column heads provide a minimum of 50% of the required end span bottom
reinforcement.
2
Area of reinforcement required; As_req = Asy1 / 2 = 785 mm /m
Provide 16 dia bars @ 200 centres - 'U' bars with 1600 mm long legs
2 2
Area of reinforcement provided; As_prov = D / (4 s) = 1005 mm /m
PASS - Edge reinforcement is OK

PUNCHING SHEAR
Corner column A1
Design shear transferred to column; Vt = ((0.45 Spanx) + ex) ((0.45 Spany) + ey) Nult = 202 kN
Design effective shear transferred to column; Veff = 1.25 Vt = 252 kN
2
Area of tension steel in x-direction; Asx_ten = Ascorner = 1340 mm /m
2
Area of tension steel in y-direction; Asy_ten = Ascorner = 1340 mm /m
Column perimeter; uc = lx1 + ly = 650 mm
Average effective depth of reinforcement; d = h c - p = 214 mm

9
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

2
Maximum allowable shear stress; vmax = min(0.8 (fcu), 5) = 4.733 N/mm
2
Design shear stress at column perimeter; v0 = Veff / (uc d) = 1.811 N/mm
PASS - Maximum concrete shear stress not exceeded at column perimeter
Shear reinforcement at a perimeter of 1.50d - (321 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 1292 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 1731 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.707 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.911 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 119 mm
Shear reinforcement at a perimeter of 2.25d - (482 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 1613 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 2161 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.707 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.730 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 16 mm
Shear reinforcement at a perimeter of 3.00d - (642 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 1934 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 2592 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.707 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.609 N/mm
v < vc no shear reinforcement required
Penultimate edge column A2
Design shear transferred to column; Vt = ((0.45 Spanx) + ex) (1.05 Spany) Nult = 453 kN
Design effective shear transferred to column; Veff = 1.4 Vt = 634 kN
2
Area of tension steel in x-direction; Asx_ten = Asx_edge = 1148 mm /m

10
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

2
Area of tension steel in y-direction; Asy_ten = Asy1e = 2094 mm /m
Column perimeter; uc = (2 lx1)+ ly = 900 mm
Average effective depth of reinforcement; d = h c - p = 214 mm
2
Maximum allowable shear stress; vmax = min(0.8 (fcu), 5) = 4.733 N/mm
2
Design shear stress at column perimeter; v0 = Veff / (uc d) = 3.292 N/mm
PASS - Maximum concrete shear stress not exceeded at column perimeter
Shear reinforcement at a perimeter of 1.50d - (321 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 2184 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 3588 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.757 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 1.356 N/mm
1.6 vc < v <= 2 vc
2
Shear reinforcement required at perimeter; Asv_req = 5 ((0.7 v) - vc) u d / (0.95 fyv) = 947 mm
Shear reinforcement at a perimeter of 2.25d - (482 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 2826 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 4628 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.756 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 1.048 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 372 mm
Shear reinforcement at a perimeter of 3.00d - (642 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 3468 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 5669 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.756 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.854 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 154 mm

11
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

Shear reinforcement at a perimeter of 3.75d - (803 mm)


Length of shear perimeter; u = uc + (2 (kx ky) k d) = 4110 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 6710 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.755 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.721 N/mm
v < vc no shear reinforcement required
Internal edge column A3
Design shear transferred to column; Vt = ((0.45 Spanx) + ex) Spany Nult = 431 kN
Design effective shear transferred to column; Veff = 1.4 Vt = 604 kN
2
Area of tension steel in x-direction; Asx_ten = Asx_edge = 1148 mm /m
2
Area of tension steel in y-direction; Asy_ten = Asye = 1570 mm /m
Column perimeter; uc = (2 lx1)+ ly = 900 mm
Average effective depth of reinforcement; d = h c - p = 214 mm
2
Maximum allowable shear stress; vmax = min(0.8 (fcu), 5) = 4.733 N/mm
2
Design shear stress at column perimeter; v0 = Veff / (uc d) = 3.135 N/mm
PASS - Maximum concrete shear stress not exceeded at column perimeter
Shear reinforcement at a perimeter of 1.50d - (321 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 2184 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 2989 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.712 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 1.292 N/mm
1.6 vc < v <= 2 vc
2
Shear reinforcement required at perimeter; Asv_req = 5 ((0.7 v) - vc) u d / (0.95 fyv) = 945 mm
Shear reinforcement at a perimeter of 2.25d - (482 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 2826 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 3862 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.712 N/mm

12
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.998 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 365 mm
Shear reinforcement at a perimeter of 3.00d - (642 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 3468 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
As_ten = 4734 mm2
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.712 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.814 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 159 mm
Shear reinforcement at a perimeter of 3.75d - (803 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 4110 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 5607 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.711 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.686 N/mm
v < vc no shear reinforcement required
Penultimate edge column B1
Design shear transferred to column; Vt = (1.05 Spanx) ((0.45 Spany) + ey) Nult = 453 kN
Design effective shear transferred to column; Veff = 1.4 Vt = 634 kN
2
Area of tension steel in x-direction; Asx_ten = Asx1e = 2513 mm /m
2
Area of tension steel in y-direction; Asy_ten = Asy_edge = 1148 mm /m
Column perimeter; uc = lx + (2 ly1) = 900 mm
Average effective depth of reinforcement; d = h c - p = 214 mm
2
Maximum allowable shear stress; vmax = min(0.8 (fcu), 5) = 4.733 N/mm
2
Design shear stress at column perimeter; v0 = Veff / (uc d) = 3.292 N/mm
PASS - Maximum concrete shear stress not exceeded at column perimeter
Shear reinforcement at a perimeter of 1.50d - (321 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 2184 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 4066 mm

13
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

Design concrete shear stress;


1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.789 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 1.356 N/mm
1.6 vc < v <= 2 vc
2
Shear reinforcement required at perimeter; Asv_req = 5 ((0.7 v) - vc) u d / (0.95 fyv) = 789 mm
Shear reinforcement at a perimeter of 2.25d - (482 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 2826 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 5241 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.788 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 1.048 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 331 mm
Shear reinforcement at a perimeter of 3.00d - (642 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 3468 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 6416 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.788 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.854 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 104 mm
Shear reinforcement at a perimeter of 3.75d - (803 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 4110 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 7592 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.787 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.721 N/mm
v < vc no shear reinforcement required

14
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

Penultimate central column B2


Design shear transferred to column; Vt = (1.05 Spanx) (1.05 Spany) Nult = 1017 kN
Design effective shear transferred to column; Veff = 1.15 Vt = 1170 kN
2
Area of tension steel in x-direction; Asx_ten = Asx1e = 2513 mm /m
2
Area of tension steel in y-direction; Asy_ten = Asy1e = 2094 mm /m
Column perimeter; uc = 2 (lx + ly) = 1600 mm
Average effective depth of reinforcement; d = h c - p = 214 mm
2
Maximum allowable shear stress; vmax = min(0.8 (fcu), 5) = 4.733 N/mm
2
Design shear stress at column perimeter; v0 = Veff / (uc d) = 3.417 N/mm
PASS - Maximum concrete shear stress not exceeded at column perimeter
Shear reinforcement at a perimeter of 1.50d - (321 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 4168 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
As_ten = 9601 mm2
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.847 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 1.312 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 872 mm
Shear reinforcement at a perimeter of 2.25d - (482 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 5452 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 12559 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.847 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 1.003 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 382 mm
Shear reinforcement at a perimeter of 3.00d - (642 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 6736 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 15516 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25

15
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

2
vc = 0.847 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.812 N/mm
v < vc no shear reinforcement required
Internal central column B3
Design shear transferred to column; Vt = (1.05 Spanx) Spany Nult = 969 kN
Design effective shear transferred to column; Veff = 1.15 Vt = 1114 kN
2
Area of tension steel in x-direction; Asx_ten = Asx1i = 2094 mm /m
2
Area of tension steel in y-direction; Asy_ten = Asye = 1570 mm /m
Column perimeter; uc = 2 (lx + ly) = 1600 mm
Average effective depth of reinforcement; d = h c - p = 214 mm
2
Maximum allowable shear stress; vmax = min(0.8 (fcu), 5) = 4.733 N/mm
2
Design shear stress at column perimeter; v0 = Veff / (uc d) = 3.254 N/mm
PASS - Maximum concrete shear stress not exceeded at column perimeter
Shear reinforcement at a perimeter of 1.50d - (321 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 4168 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 7636 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.785 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 1.249 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 872 mm
Shear reinforcement at a perimeter of 2.25d - (482 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 5452 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 9988 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.785 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.955 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 418 mm
Shear reinforcement at a perimeter of 3.00d - (642 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 6736 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)

16
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

2
As_ten = 12340 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.785 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.773 N/mm
v < vc no shear reinforcement required
Internal edge column C1
Design shear transferred to column; Vt = Spanx ((0.45 Spany) + ey) Nult = 431 kN
Design effective shear transferred to column; Veff = 1.4 Vt = 604 kN
2
Area of tension steel in x-direction; Asx_ten = Asxe = 1570 mm /m
2
Area of tension steel in y-direction; Asy_ten = Asy_edge = 1148 mm /m
Column perimeter; uc = lx + (2 ly1) = 900 mm
(Library item: Flat slab shear map C1) Average effective depth of reinforcement; d = h c - p = 214 mm
2
Maximum allowable shear stress; vmax = min(0.8 (fcu), 5) = 4.733 N/mm
2
Design shear stress at column perimeter; v0 = Veff / (uc d) = 3.135 N/mm
PASS - Maximum concrete shear stress not exceeded at column perimeter
Shear reinforcement at a perimeter of 1.50d - (321 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 2184 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 2989 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.712 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 1.292 N/mm
1.6 vc < v <= 2 vc
2
Shear reinforcement required at perimeter; Asv_req = 5 ((0.7 v) - vc) u d / (0.95 fyv) = 945 mm
Shear reinforcement at a perimeter of 2.25d - (482 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 2826 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 3862 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.712 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.998 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 365 mm
Shear reinforcement at a perimeter of 3.00d - (642 mm)

17
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

Length of shear perimeter; u = uc + (2 (kx ky) k d) = 3468 mm


Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 4734 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.712 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.814 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 159 mm
Shear reinforcement at a perimeter of 3.75d - (803 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 4110 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
As_ten = 5607 mm2
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.711 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.686 N/mm
v < vc no shear reinforcement required
Internal central column C2
Design shear transferred to column; Vt = Spanx (1.05 Spany) Nult = 969 kN
Design effective shear transferred to column; Veff = 1.15 Vt = 1114 kN
2
Area of tension steel in x-direction; Asx_ten = Asxe = 1570 mm /m
2
Area of tension steel in y-direction; Asy_ten = Asy1i = 2094 mm /m
Column perimeter; uc = 2 (lx + ly) = 1600 mm
Average effective depth of reinforcement; d = h c - p = 214 mm
2
Maximum allowable shear stress; vmax = min(0.8 (fcu), 5) = 4.733 N/mm
2
Design shear stress at column perimeter; v0 = Veff / (uc d) = 3.254 N/mm
PASS - Maximum concrete shear stress not exceeded at column perimeter
Shear reinforcement at a perimeter of 1.50d - (321 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 4168 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 7636 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.785 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 1.249 N/mm

18
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

vc < v <= 1.6 vc


2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 872 mm
Shear reinforcement at a perimeter of 2.25d - (482 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 5452 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 9988 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.785 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.955 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 418 mm
Shear reinforcement at a perimeter of 3.00d - (642 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 6736 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 12340 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.785 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.773 N/mm
v < vc no shear reinforcement required
Internal column C3
Design shear transferred to column; Vt = Spanx Spany Nult = 923 kN
Design effective shear transferred to column; Veff = 1.15 Vt = 1061 kN
2
Area of tension steel in x-direction; Asx_ten = Asxi = 1570 mm /m
2
Area of tension steel in y-direction; Asy_ten = Asyi = 1570 mm /m
Column perimeter; uc = 2 (lx + ly) = 1600 mm
Average effective depth of reinforcement; d = h c - p = 214 mm
2
Maximum allowable shear stress; vmax = min(0.8 (fcu), 5) = 4.733 N/mm
2
Design shear stress at column perimeter; v0 = Veff / (uc d) = 3.099 N/mm
PASS - Maximum concrete shear stress not exceeded at column perimeter
Shear reinforcement at a perimeter of 1.50d - (321 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 4168 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 6544 mm

19
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

Design concrete shear stress;


1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.746 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 1.190 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 834 mm
Shear reinforcement at a perimeter of 2.25d - (482 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 5452 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 8560 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.746 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.910 N/mm
vc < v <= 1.6 vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) u d / (0.95 fyv) = 403 mm
Shear reinforcement at a perimeter of 3.00d - (642 mm)
Length of shear perimeter; u = uc + (2 (kx ky) k d) = 6736 mm
Area of tension steel at shear perimeter; As_ten = (ky (px + (kx k d)) Asy_ten) + (kx (py + (ky k d))
Asx_ten)
2
As_ten = 10576 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) 0.79min(100As_ten/(ud),3) max(400/d,1) /1.25
2
vc = 0.746 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u d) = 0.736 N/mm
v < vc no shear reinforcement required

CURTAILMENT OF REINFORCEMENT
Internal column
1/2 1/3
Radius of circular yield line; r = (lx ly / ) (1.05 Spanx 1.05 Spany / (lx ly)) = 1601
mm
Minimum curtailment length in x-direction; lint_x = Max(r + 12 D, 0.25 Spanx) = 1841 mm
Minimum curtailment length in y-direction; lint_y = Max(r + 12 D, 0.25 Spany) = 1841 mm
Corner column
1/2
Radius of yield line; r = (lx1 ly / ) ((0.45 Spanx + ex) (0.45 Spany + ey)/ (lx1
1/3
ly))
r = 863 mm
Minimum curtailment length in x-direction; lcorner_x = Max(r + 12 D, 0.2 Spanx) = 1440 mm

20
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

Minimum curtailment length in y-direction; lcorner_y = Max(r + 12 D, 0.2 Spany) = 1440 mm


Edge columns
1/2
Radius of yield line in x-direction; r = (lx1 ly / ) ((0.45 Spanx + ex) (1.05 Spany) / (lx1
1/3
ly))
r = 1130 mm
Minimum curtailment length in x-direction; ledge_x = Max(r + 12 D, 0.2 Spanx) = 1440 mm
1/2
Radius of yield line in y-direction; r = (lx ly1 / ) ((0.45 Spany + ey) (1.05 Spanx) / (lx
1/3
ly1))
r = 1130 mm
Minimum curtailment length in y-direction; ledge_y = Max(r + 12 D, 0.2 Spany) = 1440 mm

21
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

A B C
ex
Span x Span x
l x1
ey
1 n e f
l y1 s 0.2 x Spany
n r s r s

c
Span y

a b
q

p e f

0.5 x Spany
x x
2

ly
j j l
Span y

p g h

3
k k m

lx
0.5 x Spanx
0.2 x Spanx

When the effective span in the x direction, Lx, is greater than the effective span in the y direction, Ly, the
reinforcement in the outer layer is assumed to be that in the x direction otherwise it is assumed to be that in the y
direction.

22
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997

Section Sheet no./rev. 1


GEODOMISI Ltd. - Dr. Costas Sachpazis Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Date Chk'd by
Calc. by
Foundation Engineering & Retaining Structures. Date App'd by Date
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 -
Mobile: (+30) 6936425722 & (+44) 7585939944, costas@sachpazis.info
Dr. C. Sachpazis 18/01/2014

REINFORCEMENT KEY

2
a = 20 dia bars @ 150 centres - (2094 mm /m);
2
b = 16 dia bars @ 200 centres - (1005 mm /m)
2
c = 20 dia bars @ 200 centres - (1570 mm /m);
2
d = 16 dia bars @ 200 centres - (1005 mm /m)
2
e = 20 dia bars @ 125 centres - (2513 mm /m);
2
f = 20 dia bars @ 200 centres - (1570 mm /m)
2
g = 20 dia bars @ 150 centres - (2094 mm /m);
2
h = 20 dia bars @ 200 centres - (1570 mm /m)
2
j = 20 dia bars @ 150 centres - (2094 mm /m);
2
k = 20 dia bars @ 200 centres - (1570 mm /m)
2
l = 20 dia bars @ 150 centres - (2094 mm /m);
2
m = 20 dia bars @ 200 centres - (1570 mm /m)
2
n = 16 dia bars @ 150 centres - (1340 mm /m)
2
p = 16 dia bars @ 175 centres - (1148 mm /m);
2
q = 16 dia bars @ 150 centres - (1340 mm /m)
2
r = 16 dia bars @ 175 centres - (1148 mm /m);
2
s = 16 dia bars @ 200 centres - (1005 mm /m)

2
Distribution bars = 12 dia bars @ 300 centres - (377 mm /m)

Shear reinforcement is required - Refer to output above for details.