You are on page 1of 8

PATENTED TECHNOLOGY

INTELLIGENT SOLAR INTERFACE SYSTEM

REDUCES ELECTRICITY BILL RUPEE SAVER SOLAR DISPLAY PANEL

AUTOMATIC CHANGE-OVER FIRST SOLAR, GRID AND THEN BATTERY

12V-24V / 20A
PWM Range - 12V/20A, 24V/20A
Su-Kams SolarCon hybrid Solar Charge Controller is an intelligent device with inbuilt intelligent
technology for utilization of solar power optimally. It can be connected with any existing HUPS/
Inverter so that your system gets converted into a solar powered system. SolarCon controls the
mains supply to the inverter. When the battery is fully charged and still solar power is available to
charge the battery, it automatically disconnects the mains from the inverter and the inverter starts
working in backup mode, now the power is supplied from battery and solar both. This helps in
utilizing the generated solar power optimally. When the battery is discharged below the pre-defined
user settable limit and mains is present, it is connected to the inverter so that the load is bypassed
to mains and the battery charging can take place.

UP TO 1000/12V INVERTER UP TO 1600/24V INVERTER

Saving Rs 750

Can be Used with any Existing Sine wave Inverter

LCD Display With Various Message


SAving Battery voltage
Solar charge on rs. 240 12.03 v (La)

PV VOLT.=12.04V Solar charge off main fail


DIP-SET: HHHLH PV voltage high grid charge off

Automatic Battery Switching

Saving Rs 750

12V
24V
Reverse protection: any combination of solar
module and battery

Saving Rs 750

Installation diagram

Sine Wave Inverter can be used as a solar inverter by using our unique
product SOLARCON. Solarcon is an intelligent converter that when
attached to the existing inverter and battery along with solar panels can
help the user to reap benefits from the power of sun.
DT-6S
Intelligent
6 STAGE 6-Stage Battery Charging
BATTERY CHARGING
TECHNOLOGY
DT-6S(Increases Battery provides effective de-sulphation of battery ensuring 10% faster charging and a
technology
Life Upto 30%)
battery life increment of at least 15% over existing technology.

EQUALIZATION CHARGING
High voltage shakes the battery electrolyte
Makes the electrolyte more efficient for charging
It is an automatic process and occurs only once in a month

FLOAT MAINTENANCE STAGE


Charging voltage is reduced to a level and held constant
Maintains full charge level of the battery

ABSORPTION CHARGING
Battery charger detects that the charging has slowed
down at about 80% of charge level
Charging current is fed slowly till the level reaches 100%

BULK CHARGING
Gives predefined high voltage and battery
current to the battery
Battery reaches about 80% of charge level

SOFT START CHARGING


Charges battery at low voltage and current
Waits till the battery gets charged by 10-15%

DE SULPHATION CHARGING
High voltage, low current helps micro pulses to detach
the Sulphate crystal from the plates
Battery produces optimum power

DT-6S
6 STAGE
BATTERY CHARGING
TECHNOLOGY
(Increases Battery
Life Upto 30%)
Automatic Temperature Compensation

0
Freezing Temperature
10
Low Temperature
25 40
Normal Temperature High Temperature

72% Charge 85% Charge 100% Full Charge 108% Charge

ATC involves a hi-tech sensor, which senses the outside ambient temperature and accordingly adjusts the charging of batteries.
The sensor automatically controls over-charging and under-charging, increases the battery life by at least 6 months and provides
excellent battery back-up.

> Su-Kams first Home UPS with INCREASES BATTERY LIF > ATC Sensor it kept close to the
ATC Technology senses the battery bank that determines
E UPTO 30%

outside temperature and battery temperature


accordingly adjusts charging of and automatically adjusts the
batteries. target charge voltages accordingly.

> This new charging system ADJUSTS > This automatic sensing controls
monitors the battery temperature BATTERY over charging and under
and automatically regulates the CHARGING TO charging thereby increasing
voltage. CLIMATE battery life by 30% and providing
CHANGE excellent battery back-up.

CONTROLS OVER/UNDER
CHARGING
INCREASES BATTERY LIFE BY ATLEAST 6 MONTHS
Front Side View

Saving Rs 750
Saving Rs 750
Key-Pad Used for Reset Rupees and LCD Back Light ON (Press any
key for 1 Sec to On back light of LCD)

Key-Pad

Back Side View

Inverter Solar Mains Fuse


Mains Input Connection

Led for
Solar/Battery
Reverse
Mains Input Battery
Connection
Salient Features of SolarCon Technology

30% MORE SAVING


WITH SOLARCON The in-built sensor in
SolarCon senses the outside SOLARCON STAGE
SolarCon charge controller temperature and regulates
tracks the maximum power battery charging I.E. DT-6S Six Stage Charging
generated by solar panels over-charging or under Technology For Efficient
and transfers the same to charging by controlling the
the battery with minimal Charging And Longer
boost voltage of the battery. Battery Life
internal losses

th
GENERATION
Microprocessor
EQUALISATION PV HIGH CURRENT
The advanced solar charging PROTECTION
technology in SolarCon The intelligent micro
processor in SolarCon The solar charge controlling
smartly generates voltage to device in SolarCon
shake he battery electrolyte controls all the internal
processes smoothly. regulates battery current and
to ensure efficient charging provides power voltage
high current protection

REVERSE BATTERY REVERSE BATTERY BATTERY HIGH


CURRENT FLOW CONNECTION VOLTAGE PROTECTION
PROTECTION AT NIGHT The micro-controller in Micro controller and digital
SolarCon charge controller SolarCon helps protect signaling processing
protects the reverse battery against reverse polarity technology in SolarCon
current flow from the battery of the battery saves battery during high
to solar array at night voltage condition

AUTOMATIC OUTPUT OVERLOAD/


BATTERY SWITCHING SHORT CIRCUIT
The SolarCon charge PROTECTION
controller enables the
customer to automatically The micro controller and
switch from one battery digital signaling processing
system to a double battery in Solar Con charge controller
system without changing provides overload and short
the charge controller. circuit protections.
Technical Specification of SolarCon
Nominal Battery Voltage 12V (Single Battery) 24V (Double Battery)
Recommended Home UPS / Inverter Range Upto 1000VA/12V Upto 1500VA/24V
Nominal Panel Wattage Typical: 350 Wp Typical: 600/700 Wp (60 Cells /72 Cells)
Maximum PV open circuit voltage 25 Voc 50 Voc
Power Conversion Efficiency 95 %
Charging Stages Three stage charging algorithm: Bulk, Absorption and Float
Bulk Charge Voltage in FPLA Mode 14.2 V 2% 28.4 V 2%
Bulk Charge Voltage in TUB Mode 14.6 V 2% 29.2 V 2%
Absorption period Held battery voltage at bulk voltage level for a cumulative period of 2 hour
Float voltage 13.7 V 2% 27.4 V 2%
Automatic Temperature compensation in Provided
Bulk Voltage only
(18 mV 3mV / C/12 V Battery) (25C Ref)
Battery Low Warning 10.7V 2% 21.4V 2%
Battery Low Warning Recovery 11V 2% 22V 2%
Battery High Shutdown 16V 2% 32V 2%
Battery High Shutdown Recovery 14V 2% 28V 2%
Max. Charging Current of SCC 24A1A
Regulation Current 17A1A
PV High Current (Initially when the system 30A 2A
boots, if it detects high current from PV, it will
go to PV high current shutdown)
Auto Restart after PV High Current 3.5 minutes. 20 sec
PV High Voltage shutdown/ recovery 30V / 25V 5% 60V / 50V 5%
Rupees saving reset Provided through keypad
Grid parameters
Input Range 90V - 300V 20V
Grid automatic connect to Inverter. Grid connects to inverter when battery voltage Grid connects to inverter when battery voltage
11.4 / 11.8 / 12.2 / 13V 2% (As per setting of 22.8 / 23.6 / 24.6 / 26V 2% (As per setting of
selection Switch) if grid is within the specified range. selection Switch) if grid is within the specified
range.
Grid automatic Disconnect from Inverter Grid disconnect automatic when battery reaches Grid disconnect automatic when battery reaches
float charge voltage 13.7V 2%. float charge voltage 27.4V 2%.

Protections
Short Ckt. (Mains Mode) Yes (through Fuse)
Reverse Battery Yes with LED indication
Reverse PV array Yes with LED indication
Surge/ spike potection Yes through MOV

LCD Display Messages


Backup Mode & Mains Mode Battery Voltage / Solar Status / Rupees Saving / Mains Low / Mains High / Battery Low / Battery High

General
Service type use Indoor
Operating Temperature Range 0C to + 55C
Humidity Up to 95 % RH (NC)
Storage Temp. 0C to + 40C
Cooling Natural
Dimensions (WxDxH) in mm 215mm X 156mm X 68mm
Weight () 100 gm. 1.3 Kgs
Enclosure MS Sheet metal

Su-Kam Power Systems Limited

Corporate Office: Plot No. 54,


Udyog Vihar, Phase VI, Sector-37,
Gurgaon - 122001, Haryana, INDIA
Tel: +91-124-4170500
Fax: +91-124-4038700/1/2
E-mail: info@su-kam.com
Website: www.su-kam.com Copyright 2015 Su-Kam Power Systems Limited.
Helpline No.: 1800-102-7555 (Toll Free) All rights reserved.

You might also like