Synchronous Machines
Author: BNSS Shankar, M.Tech (IITK), MIE
Special Note:
No part of this publication may be reproduced, stored in a retrieval system, or transmitted
in any form or by any means, electronic, mechanical, photocopying, digital, recording or
otherwise, without the written permission of the author.
If you find any mistakes, please write me an email. If I satisfy with your explanation, I
will update the document. Key will be available in this blog on 30/06/2016.
The following test will carry 30 marks and you can complete in one hour. You can also
use scientific calculator.
impedance method is 25%. The value of voltage regulation by using mmf method is
(A) < 25% (B) > 25% (C) 25% (D)Any of the above
10.
Consider the statements:
I1 0.1 0.2 2
2.0 j 3.2 j 1
E1 = 10000 E 2 = 1000 10 0
f f
13.
Pm C A
E C
Psh A B E
D
max
B
0 max t
14.
A 3, Y connected 45 kVA, 220 V, 118 A, 1200 rpm, 50Hz salient pole synchronous machine
potier triangle is shown below. a
The value of ab = 50
The value of potier reactance is _______. b c
15.
R R
Supply Alternator
phase La phase
Sequence Sequence
B Y
RBY & RYB &
Lb
Frequency Frequency
Y B
f1 Hz f2 Hz
Lc
The lamps (La, Lb & Lc) connection is shown in figure. The sequence of brightness and darkness
for frequency f2 < f1 are
(A) La Lb Lc & La Lb Lc (B) La Lc Lb & La Lb Lc
(C) La Lb Lc & La Lc Lb (D) Lc Lb La & Lc Lb La
16.
A 3- Y connected turbo alternator feeds power to 11 kV infinite bus, through parallel
transmission line each having a reactance of 4 and the generator synchronous reactance is 2 .
The mechanical input to the alternator and its excitation are adjusted so that the operating power
factor at alternator terminals is unity and rated current of 500 A is delivered. The reactive power
(in kVAr) delivered to the infinite bus is ______.
17.
Three alternators, operating in parallel at a bus frequency of 50 Hz, share a load of 150 MW as
follows.
iB
A
iC iA
5
iA = Im sin(t + ), iB = Im sin(t ), iC = Im sin(t + )
6 2 6
The rotating mmf would be directed along the axis of phase B when t equals to
(A) (B) (C) (D)
3 6 3
20.
A 75-MVA, 13.8kV, 3-phase, eight-pole, 60Hz salient pole synchronous machine has the
following d-axis and q-axis reactance: Xd = 1.0 p.u. and Xq = 0.6 p.u. The synchronous generator
is delivering rated MVA at rated voltage and 0.866 power factor lagging. Choose a power base
of 75 MVA and voltage base of 13.8 kV. If the machine is connected to 3-phase system having
1.0 p.u. voltage, the maximum power (in p.u) that generator can deliver _______.