97105 NAMUR

3/2, 5/2 & 5/3 spool valves


electromagnetic actuated, indirectly controlled
G 1/4, 1/4 NPT, G 1/2, 1/2 NPT or flanged with NAMUR interface

For single and double operated actuators


Exhaust air recirculation at 3 way function
Use of monostable valves for safety systems
up to SIL 4 (IEC 61508)
Add-on manual override
Suited for outdoor use under critical
environment conditions (see solenoid list)
The solenoid valves are applicable in the
protection classes Ex emb, Ex dmb, Ex mb,
Ex ia for zones 1 & 2 (gas), 21 & 22 (dust),
ATEX cat. II 2GD
DIN EN 61508
International approvals: IECEx, FM, CSA IEC 61508
bis SIL 4
others on request Approval depends on magnetic
system, see page 5 and 6!

Technical features
Medium: Orifice: Fluid/Ambient temperature: Materials:
Filtered, non-lubricated and DN 6 or DN 8 Valve: Body: aluminium 3.0615 with
dried compressed air, instru- Port size:: -40 ... +65C (NBR) (-40...+149F) surface treatment for critical
ment air, G 1/4, 1/4 NPT, G 1/2, 1/2 NPT, -25 ... +80C (HNBR) environmantal conditions
nitrogen and other non- NAMUR-Flange (-13...+176F) (approved according to DIN 50018:
flammable neutral, dry fluids Operating pressure: Depending on solenoid system Condensate test with alternating
Operation: 2,5 ... 8 (36 ... 116 psi) Air supply must be dry enough temperatures in sulphuric
Indirect solenoid operated with internal air supply to avoid ice formation at atmosphere,
spool valves 0 ... 8 bar (0 ... 116 psi) with ex- temperatures below +2C DIN 50021/ASTM B117-73:
Mounting position: ternal air supply (G1/2, 1/2 NPT (+35F). Salt spray test with different
Optional, impuls valves or low power pilot system only) Installed in the open protect all sodium chloride solutions,
preferably horizontally connections against the tested in ammonia atmosphere),
penetration of moisture! brass 2.0401 (Ms 58)
stainless steel 1.4404 (316 L)
Seals:
NBR (special perbunan) or
HNBR

11/12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en/en 5.4.335.01
97105 NAMUR

3/2, 5/2 and 5/3 way valves with seals NBR -40 ... +65C*3
Housing: aluminium anodized
Symbol Ports Actuation Operating pressure Flow *6) Test certification Weight Dimension Model *1)
1, 3, (5) 2, 4 (bar) (l/min) IEC 61508 *2) (kg) No.
G 1/4 Flange Solenoid/spring 2,5...8 1300 x 0,45 1 9710505
4 2 4 2
1/4 NPT Flange Solenoid/spring 2,5...8 1300 x 0,45 1 9710515

5 13 513 G 1/2 Flange Solenoid/spring (0) 2,5...8 2600 0,80 7 9710595


1/2 NPT Flange Solenoid/spring (0) 2,5...8 2600 0,80 7 9710596
4 2 4 2 G 1/4 Flange Solenoid/solenoid 2,5...8 1300 0,65 2 9711505
1/4 NPT Flange Solenoid/solenoid 2,5...8 1300 0,65 2 9711515
5 13 513
4 2 G 1/4 Flange Solenoid/solenoid (APB) 2,5...8 950 0,7 3 9712505
1/4 NPT Flange Solenoid/solenoid (APB) 2,5...8 950 0,7 3 9712515
513

Housing: brass
5 13

Symbol Ports Actuation Operating pressure Flow *6) Test certification Weight Dimension Model *1)
1, 3, (5) 2, 4 (bar) (l/min) IEC 61508 *2) (kg) No.
G 1/4 Flange Solenoid/spring 2,5...8 1300 x 1,00 1 9710605
4 2 4 2
1/4 NPT Flange Solenoid/spring 2,5...8 1300 x 1,00 1 9710615

5 13 513

4 2 4 2 G 1/4 Flange Solenoid/solenoid 2,5...8 1300 1,40 2 9711605


1/4 NPT Flange Solenoid/solenoid 2,5...8 1300 1,40 2 9711615
5 13 513

4 2 G 1/4 Flange Solenoid/solenoid (APB) 2,5...8 950 1,50 3 9712605


1/4 NPT Flange Solenoid/solenoid (APB) 2,5...8 950 1,50 3 9712615
513

Housing: stainless
5 13
5 1 steel

Symbol Ports Actuation Operating pressure Flow *6) Test certification Weight Dimension Model *1)
1, 3, (5) 2, 4 (bar) (l/min) IEC 61508 *2) (kg) No.
G 1/4 Flange Solenoid/spring 2,5...8 1300 x 1,00 1 9710705
4 2 4 2
1/4 NPT Flange Solenoid/spring 2,5...8 1300 x 1,00 1 9710715

5 13 513

4 2 4 2 G 1/4 Flange Solenoid/solenoid 2,5...8 1300 1,40 2 9711705


1/4 NPT Flange Solenoid/solenoid 2,5...8 1300 1,40 2 9711715
5 13
513

4 2 G 1/4 Flange Solenoid/solenoid (APB) 2,5...8 950 1,50 3 9712705


1/4 NPT Flange Solenoid/solenoid (APB) 2,5...8 950 1,50 3 9712715
513

*1) When ordering please indicate solenoid, voltage and current (frequency)
*2) Since May 2008, Date code A8192
*3) For operation in plants according to IEC 61511/61508 -40 ... +40C see test certificate (on request)
*6) Flow characteristics conforms to ISO6358 [6 5 bar]
Note for *6): Connecting pipe/fitting: In order to ensure and a pressure collapse avoid the flow, the supply air cross section should with 1/4: 8 mm; with
1/2: 10 mm. With smaller cross section the inlet (A1) should more largely, however at least equally large line at the port (A2; A1).

Valve function: APB = All Ports Blocked


3/2 or 5/2 way function (Conversion instructions see page 14)

N/en/en 5.4.335.02 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
11/12
97105 NAMUR

3/2, 5/2 and 5/3 way valves with seals HNBR -25 ... +80C *3)
Housing: aluminium anodized
Symbol Ports Actuation Operating pressure Flow *6) Test certification Weight Dimension Model *1)
1, 3, (5) 2, 4 (bar) (l/min) IEC 61508 *2) (kg) No.
G 1/4 Flange Solenoid/spring 2,5...8 1300 x 0,45 1 9710205
4 2 4 2
1/4 NPT Flange Solenoid/spring 2,5...8 1300 x 0,45 1 9710215

5 13 513 G 1/2 Flange Solenoid/spring (0) 2,5...8 2600 x 0,80 7 9710295


1/2 NPT Flange Solenoid/spring (0) 2,5...8 2600 x 0,80 7 9710296
4 2 4 2 G 1/4 Flange Solenoid/solenoid 2,5...8 1300 0,65 2 9711205
1/4 NPT Flange Solenoid/solenoid 2,5...8 1300 0,65 2 9711215
5 13 513
4 2 G 1/4 Flange Solenoid/solenoid (APB) 2,5...8 950 0,7 3 9712205
1/4 NPT Flange Solenoid/solenoid (APB) 2,5...8 950 0,7 3 9712215
513

M M
Housing: aluminium anodized, Inlet
V filter
B EM and exhaust guard
-53A EMH

Symbol Ports Actuation Operating pressure Flow *6) Test certification Weight Dimension Model *1)
1, 3 (5) 2, 4 (bar) (l/min) IEC 61508 *2) (kg) No.

4 2 4 2 G 1/4 Flange Solenoid/spring 2,5...8 1300 x *4) 0,45 8 9710901

5 1 3 5 1 3

4 2 4 2 G 1/4 Flange Solenoid/solenoid 2,5...8 1300 0,65 9 9711901

5 1 3 5 3
1

Housing: brass
Symbol Ports Actuation Operating pressure Flow *6) Test certification Weight Dimension Model *1)
1, 3, (5) 2, 4 (bar) (l/min) IEC 61508 *2) (kg) No.
G 1/4 Flange Solenoid/spring 2,5...8 1300 x 1,00 1 9710305
4 2 M4 2
1/4 NPT Flange Solenoid/spring 2,5...8 1300 x 1,00 1 9710315

5 13 513

4 2 4 2 G 1/4 Flange Solenoid/solenoid 2,5...8 1300 1,40 2 9711305


1/4 NPT Flange Solenoid/solenoid 2,5...8 1300 1,40 2 9711315
5 13 513
4 2 G 1/4 Flange Solenoid/solenoid (APB) 2,5...8 950 1,50 3 9712305
1/4 NPT Flange Solenoid/solenoid (APB) 2,5...8 950 1,50 3 9712315
513

Housing: Stainless
5 3 51
steel
Symbol Ports Actuation Operating pressure Flow *6) Test certification Weight Dimension Model *1)
1, 3, (5) 2, 4 (bar) (l/min) IEC 61508 *2) (kg) No.
G 1/4 Flange Solenoid/spring 2,5...8 1300 x 1,00 1 9710405
4 2 4 2
1/4 NPT Flange Solenoid/spring 2,5...8 1300 x 1,00 1 9710415

5 13 513

4 2 4 2 G 1/4 Flange Solenoid/solenoid 2,5...8 1300 1,40 2 9711405


1/4 NPT Flange Solenoid/solenoid 2,5...8 1300 1,40 2 9711415
5 13 513
4 2 G 1/4 Flange Solenoid/solenoid (APB) 2,5...8 950 1,50 3 9712405
1/4 NPT Flange Solenoid/solenoid (APB) 2,5...8 950 1,50 3 9712415
513

*1) When ordering please indicate solenoid, voltage and current (frequency)
*2) Since May 2008, Date code A8192
*3) For operation in plants according to IEC 61511/61508 61508 -25 ... +65C or 0...+80C see test certificate (on request)
*4) Test certificate without inlet filter and exhaust guard
*6) Flow characteristics conforms to ISO6358 [6 5 bar]
Note for *6): Connecting pipe/fitting: In order to ensure and a pressure collapse avoid the flow, the supply air cross section should with 1/4: 8 mm; with
1/2: 10 mm. With smaller cross section the inlet (A1) should more largely, however at least equally large line at the port (A2; A1).

Valve function: APB = All Ports Blocked


3/2 or 5/2 way function (Conversion instructions see page 14)

11/12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en/en 5.4.335.03
97105 NAMUR

Option selector 971...


Function Substitute Air supply Substitute
5/2 way with spring return 0 Internal 0
(3/2 way with adapter plate for
Externa Z
NAMUR flange)
Voltage Substitute
5/2 way impuls (3/2 way with 1
adapter plate for NAMUR flange) 24 V d.c. 024.0
5/3 way with spring return (ABP) 2 230 V a.c. 230.5
Material: Housing/seals Substitute Solenoid Substitute
Aluminium/HNBR (-25 ... + 80C) 2 see solenoid table
Brass/HNBR (-25 ... + 80C) 3
Stainless steel/HNBR (-25 ... + 80C) 4
Aluminium/NBR (-40 ... + 65C) 5
Brass/NBR (-40 ... + 65C) 6
Stainless steel/NBR (-40 ... + 65C) 7
Ports size Substitute
G 1/4 0
1/4 NPT 1
G 1/2 9
1/2 NPT (in connection with version 9
code 6 below described)
Version Substitute
Without manual override (retrofit) 5
Semi automatic (on request) 7
Low power pilot (see page 5) 9
For 1/2 NPT only + NAMUR 6
(manual override retrofit)
Valve function:
APB = All Ports Blocked

N/en/en 5.4.335.04 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
11/12
97105 NAMUR

Solenoid operators
Power consumption Rated current ATEX- Protection class *7)/ Temperature Electrical Weight Dimension Circuit Model
Category Ex-Protection class Ambient/ connection diagram
24 V d.c. 230 V a.c. 24 V d.c. 230 V a.c. Fluid
(W) (VA) (m A) (m A) (C) (kg) No. No.
1,9 2,1 *5) 78 10 IP00 without connector *5) -25 ... +60 DIN EN 175 301-803 0,3 7 1/5 0763
IP65 with connector *5) Form A

3,6 - 150 - II2G Ex mb II T4 *1) -20 ... +70 3 m Cable 0,4 9 4 0298 *8)
II2D
Ex tD A21 IP66 T110
- 4,6 - 18 II2G Ex mb II T4 *1) -20 ... +70 3 m Cable 0,4 9 7 0299 *8)
II2D
Ex tD A21 IP66 T110
0,8 - 33 - II2G Ex e mb IIC T5/T6 Gb -40 ... +80 T5 M20 X 1,5 *6) 0,6 10 4 4200 *8)
II2D -40 ... +70 T6
Ex tb IIIC T130C Db IP66 *2), *10) -40 ... +80

- 1,3 - 6 II2G Ex e mb IIC T5/T6 Gb -40 ... +80 T5 M20 X 1,5 *6) 0,6 10 7 4201 *8)
II2D -40 ... +70 T6
Ex tb IIIC T130C Db IP66 *2), *10) -40 ... +80

0,8 - 33 - II2G Ex d mb IIC T5/T6 Gb -40 ... +80 T5 1/2 NPT *6) 0,8 17 20 4600 *8)
II2D Ex e mb IIC T5/T6 Gb -40 ... +70 T6
Ex tb IIIC T130C Db IP66 *3), *10) -40 ... +80

0,8 - 33 - II2G Ex d mb IIC T5/T6 Gb -40 ... +80 T5 M20 X 1,5 *6) 0,8 17 21 4602 *8)
II2D Ex e mb IIC T5/T6 Gb -40 ... +70 T6
Ex tb IIIC T130C Db IP66 *3), *10) -40 ... +80

- 1,3 - 6 II2G Ex d mb IIC T5/T6 Gb -40 ... +80 T5 1/2 NPT *6) 0,8 17 20 4601 *8)
II2D Ex e mb IIC T5/T6 Gb -40 ... +70 T6
Ex tb IIIC T130C Db IP66 *3), *10) -40 ... +80

- 1,3 - 6 II2G Ex d mb IIC T5/T6 Gb -40 ... +80 T5 M20 X 1,5 *6) 0,8 17 21 4603 *8)
II2D Ex e mb IIC T5/T6 Gb -40 ... +70 T6
Ex tb IIIC T130C Db IP66 *3), *10) -40 ... +80

Stainless steel 0,8 33 II2G Ex mb d IIC T4/T6 -40 ... +50 T4 M20 X 1,5 *6) 1,2 19 4 4802
II2D Ex mb e II T4/T6 -40 ... +40 T6 *8), *11)
Ex tD A21 IP66 -40 ... +80
T100 *2), *12)
1,3 6 II2G Ex mb d IIC T4/T6 -40 ... +50 T4 M20 X 1,5 *6) 1,2 19 7 4803
II2D Ex mb e II T4/T6 -40 ... +40 T6 *8), *11)
Ex tD A21 IP66 -40 ... +80
T100 *2), *12)
1,4 - 59 - XP/DIP, Div. 1 & 2 -20 ... +60 Flying leads 0,4 18 1 3720
Cl. I, Gr. A-D 450 mm long
Cl. II / III, Gr. E-G
T3 (160C) *4)
NEMA
4, 4X, 6, 6P, 7, 9
Standard voltages 24 V d.c., 230 V a.c., other voltages on request. *8) Suitable for outdoor installation
Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *10) IECEx Certificate of Conformity IECEx KEM 09.0068X
*1) EG-Type-Examination-Certificate KEMA 02 ATEX 1347 X *11) EG-Type-Examination-Certificate PTB 06 ATEX 2054 X
*2) EG-Type-Examination-Certificate KEMA 98 ATEX 4452 X *12) IECEx Certificate of Conformity IECEx PTB 07.0039X
*3) EG-Type-Examination-Certificate PTB 02 ATEX 2085 X Attention: The protection class for coil series 46xx and 48xx is determined by
the choice of cable gland.
*4) CSA-LR 57643-6, FM Approvals
Example: if an ATEX-certified cable gland is used that has Ex d type of protection,
*5) Required connector: type 0570275 the solenoid will have the protection class Ex dmb; if a cable gland with Ex e
*6) Connector cable gland not supplied, see table Accessories type of proteciton is used, the solenoid will have protection class Ex emb.
*7) IP-Protection class according to EN60529

Solenoid actuators for intrinsically-safe circuits


Nominal Min. required Resistance Required Protection Temperature Weight Dimension Circuit Model
resistance switching current Rw 60 coil voltage at class Ambient/Fluid diagram
RN coil terminal
() (mA) () Rw 60 (V) (C) (kg) No. No.
200 33 240 8 Ex ia IIC T6 -40 ... +60 0,85 6 10 2050
391 24 460 11 Ex ia IIC T4 -40 ... +80 0,85 6 10 2051
736 17 880 15 Ex iaD 21 T80C -40 ... +60 0,85 6 10 2052
1220 13 1460 19 Ex iaD 21 T100C -40 ... +80 0,85 6 10 2053
EG-Type-Examination-Certificate PTB 07 ATEX 2019 (Kat. II 2 GD) When selecting an intrinsically safe power supply, the permissible maximum
IECEx Certificate of Conformity IECEx PTB 07.0017 values according to the Certificate of Conformity should be taken into acount.
Cable gland is included in delivery Ui = 45 V, Ii = 500 mA according to Tab. A. 1, EN 60079-11
Pi = 2,0 W, Li and Ci can be ignored.

11/12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en/en 5.4.335.05
97105 NAMUR

3/2, 5/2 and 5/3 way valves, indirect solenoid actuated using low-power pilot system in protection class
Ex ia IIC T4/T6,
seals NBR -40 ... +65C (-40...+149F)
Symbol Ports Actuation Material Operating pressure Flow *6) Weight Dimension Model *1)
1, 3, (5) 2, 4 (bar) (l/min) (kg) No.
4 2 4 2 G 1/4 Flange Solenoid/spring Aluminium 2,5...8 1300 0,45 4 9710509
V 52-
1/4 NPT -Flange Solenoid/spring Aluminium 2,5...8 1300 0,45 4 9710519
5 13 513

4 2 4 2 G 1/4 Flange Solenoid/solenoid Aluminium 2,5...8 1300 0,65 5 9711509


V-52-
1/4
52NPT- H-F
Flange Solenoid/solenoid Aluminium 2,5...8 1300 0,65 5 9711519
5 13 5 51 13

4 2 G 1/4 Flange Solenoid/solenoid (APB) Aluminium 2,5...8 950 0,7 6 9712509


1/4 NPT
V5252 Flange
H F Solenoid/solenoid (APB) Aluminium 2,5...8 950 0,7 6 9712519
513

3/2, 5/2 and 5/3 way 32spec-EMR-EMR


valves, indirect
V-53A- solenoid
V 5MH
B
actuated using low-power pilot system in protection class
Ex ia IIC T4/T6,
5 3
seals HNBR -25 ... +80C
Symbol Ports Actuation Material Operating pressure Flow *6) Weight Dimension Model *1)
1, 3 (5) 2, 4 (bar) (l/min) (kg) No.
4 2 4 2 G 1/4 Flange Solenoid/spring Aluminium 2,5...8 1300 0,45 4 9710209
V-52-
1/4 NPT -Flange Solenoid/spring Aluminium 2,5...8 1300 0,45 4 9710219
5 13 513

4 2 4 2 G 1/4 Flange Solenoid/solenoid Aluminium 2,5...8 1300 0,65 5 9711209


V-52-
1/4 NPT
52B- H-F
Flange Solenoid/solenoid Aluminium 2,5...8 1300 0,65 5 9711219
5 13 5 51 13

4 2 G 1/4 Flange Solenoid/solenoid (APB) Aluminium 2,5...8 950 0,7 6 9712209


1/4
52NPT
V-52- Flange
H-F Solenoid/solenoid (APB) Aluminium 2,5...8 950 0,7 6 9712219
513

*1) When ordering 2please indicate solenoid, voltage and electrical connection, see below
2
*6) Flow characteristics conforms
V 2spe to ISO6358
EM EMR [6 5 bar]
- 2B-EMR
Note for *6): Connecting pipe/fitting: In order to ensure and a pressure collapse avoid the flow, the supply air cross section should with 1/4: 8 mm; with
1/2: 10 mm.
5 With
3 smaller cross section
5 1 3 the inlet (A1) should more largely, however at least equally large line at the port (A2; A1).

Valve function: APB = All Ports Blocked


3/2 or 5/2 way function (Conversion instructions see page 14)

Low-power pilot system in protection class Ex ia IIC T4/T6


Power Switch-on Switch-on Switch-off Switch-off Rated Resistance Protection Temperature Circuit Model
P (+20C) voltage voltage voltage voltage current coil class Ambient diagram *4)
U on (+20C) U on (+80C) U off (+20C) U off (-25C) I on R (+20C) No.
6,3 mW 4,3 V 5,2 V 1,44 V 1,2 V 1,45 mA 2800 Ex ia IIC T4 -40 bis +80C 11 2085
23,2 mW 16 V 16,8 V 5,4 V 4,7 V 1,45 mA 10900 Ex ia IIC T6 -40 bis +60C 11 2086

Max. values Ex i Ordering example


Ui Ii Pi *5) 9710509. 2085. 005. 00
(V) (mA) (mW)
25 150 250 Valve Pilot 6,3 mW Electrical connection 00 internal air supply
27 125 250 005 M16 x 1,5 cable gland 0Z external air supply
28 115 250
30 100 250
32 85 250
*4) Category II2G, EG-Type-Examination-Certificate PTB 06 ATEX 2001U
Air consumption: home position 60 l/h, operating position 15 l/h
*5) Model 2086 without Pi limiting. Ci and Li can be ignored.

N/en/en 5.4.335.06 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
11/12
97105 NAMUR

Accessories
Cable gland Connector
Protection class Ex e, Ex d (ATEX),
Nickel plated brass/
stainless steel

Page 1
Thread Cable Material Protection class (ATEX) Model
M 20x1,5 5,0...8,0 mm Nickel plated brass II2GD Ex e 0588819 0570275
M 20x1,5 10...14 mm Nickel plated brass II2GD Ex d 0588851 0663303 (with rectifier)
1/2-14-NPT 7,5...11,9 mm Nickel plated brass II2GD Ex d 0588925
M 20x1,5 9,0...13 mm Stainless steel 1.4571 (316 Ti) II2GD Ex e 0589385
M 20x1,5 7,0...12 mm Stainless steel 1.4404 (316 L) II2GD Ex d 0589395
M 20x1,5 10...14 mm Stainless steel 1.4404 (316 L) II2GD Ex d 0589387

Adaptor complete Inlet filter Silencer (plastic) *1) Exhaust guard *2) Silencer (stainless steel) *1) Manual override Manual override
(Adaptor, inlet filter and (for start-up only)
seal ring)

Page 17 Page 17 Page 17 Page 17 Page 17 Page 16 Page 16


0613487 0681173 (G1/4, 1/4 NPT) M/S2 (G1/4) 0613422 (G1/4, 1/4 NPT) 0014613 (G 1/4) 0553886 (without detent) 0613379 (without detent)
C/S2 (1/4 NPT) 0613423 (G1/2, 1/2 NPT) 0613678 (1/4 NPT) 0553887 (with detent)
M/S4 (G1/2) 0014813 (G 1/2)
C/S4 (1/2 NPT) 0613679 (1/2 NPT)
*1) For indoors use only
*2) For outdoors use

Throttle control plate Flange plate, for G1/4 only Yoke Distance plate for coils Mounting plate
90 and 270

Page 15 Page 15 Page 15 Page 15 Page 15


4040239 (only for G1/4) 0612790 (NAMUR single connection plate) 0540593 0540109 0613453 (90)
0612791 (NAMUR-rip use in combination with 0612790) 0613556 (270)

11/12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en/en 5.4.335.07
97105 NAMUR

Dimensions Dimensions shown in mm

Valves Projection/First angle

1 2
5 1 3 5 1 3

95,5
124
71,5

3,5

3,5
4 2 4 2
45

32

45

32
6 15,2 6 15,2
19,7 19,7 1
1
51 24

3 3

~ 106
~ 106

41 22 22

46
4,5
4,5

27,5
27,5

13,5
13,5

5/2 5/2
7

138 61,5
7

6
83,5
105,5
162
3
5 1 3

113,5

89,5
3,5

4 2
45

32

6 15,2
19,7 1

3
~ 106
46
4,5
27,5

13,5

5/2
7

79
6
101
123
175,5

1 Solenoid dimensions on page 13


3 Port G 1/4 or 1/4 NPT
6 NAMUR connection plate 3/2 or 5/2 way function

N/en/en 5.4.335.08 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
11/12
97105 NAMUR

Dimensions shown in mm
4 5
Projection/First angle

89,5
89,5
89,5

67
67

13,5
67

4,5
45

27,5
4,5
27,5
27,5

13,5
13,

5/2

7
5/2
5/2
77

35 3 6 2
3
3 6
6 2
2

163

A
140
125
35 24
51 24

2
1,2
4
4 2

45
32
45

32

5 1 3

4,5
74

5 1 3
9

101
25 22 22
41 22 22

4
4

2 External control pressure connection G1/8 or 1/8 NPT


3 Port G1/4 or 1/4 NPT
4 Electrical connection 005
6 NAMUR connection plate 3/2 or 5/2 way function
9 Position of gasket internal pilot air
10 Position of gasket external pilot air

Electrical connection
C C
005

C-C
P ext.

27

P int.
9

10

11/12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en/en 5.4.335.09
97105 NAMUR

Dimensions shown in mm
6 7
Projection/First angle

32 32 21 3

89,5
61
27,5

40
62
13,5

36
5/2

7
5/2

16
4,5

92 11 6 2

9
4 2 6
M6
2

24 30

70
4 2 45
32

45

3 1 5
74

25 22 22 5 1 3
40 36 40,5
82
128 19
202,5

4
180,5
1 Solenoid optional turnable
2 External control pressure connection G1/8 or 1/8 NPT
3 Port G1/2 or 1/2 NPT
4 Electrical connection 005
6 NAMUR connection plate 3/2 or 5/2 way function
9 Position of gasket internal pilot air
10 Position of gasket external pilot air
11 Port G1/4 or 1/4 NPT

C C

C-C
P ext.

P int.
9

Electrical connection

005
10

27

N/en/en 5.4.335.10 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
11/12
97105 NAMUR

Dimensions shown in mm
8
Projection/First angle
5 1 3

41 22 22
19,5
16

54,5
10
4 2
32

15,2
19,7
49,5 24
~204
107
42

1
40,5

G1/4
92,5
~106
5 1 3
27,5

33

M5
6
7,5

~124 1 Solenoid turnable


4 2 137,5 6 NAMUR connection plate 3/2 or 5/2 way function

11/12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en/en 5.4.335.11
97105 NAMUR

Dimensions shown in mm
9
Projection/First angle

5 1 3

61,5 22 22

19,5
16

54,5
10

62,5
4 2

15,2
19,7
70 24

290
42 130,5
107
1 1
40,5

G1/4

~106
92,5

5 1 3
27,5

33
M5
6

7,5
158
4 2 214,5

1 Solenoid turnable
6 NAMUR connection plate 3/2 or 5/2 way function

N/en/en 5.4.335.12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
11/12
97105 NAMUR

Dimensions shown in mm
Dimensions
Projection/First angle
Solenoid operators

7 86,5 9
53,5 1
49

41
17
40,5

43 82,5
89

M16 x 1,5 12

33
43

28
34

19,5
63,5
27
73

10 2 17
107
70,5 2
40,5
64,5

41,5
91,5

27

53
20

M 20 x 1,5 3 59
42
54,5

56

29 43
122

18 19
68 2
2
1/2 - 14 NPT
41
40,5

45
43

53
84 5

63 2
33,5

56
43

1 Connector 4 x 90 turnable
2 13 (with spacer tube)
26 4 3 M20 x 1,5 or 1/2 - 14 NPT 28 35
4 Flying leads 450 mm long
5 112
M20 x 1,5

11/12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en/en 5.4.335.13
97105 NAMUR

Circuit diagrams

1 4 5 7

10 11 20 21

NAMUR hole pattern (driving side)


Port size G1/4 Port size G1/2
45
32
M6 4
M5 4

2 2
24

40
2 3 2
3
3
3

5
5

2 Port 2 (A) NAMUR quick exhaust module for a better


kv-value by exhaust see data sheet 5.4.820
3 Hole for coding stud
4 M5 & M6 (10 deep)
5 Port 3 (R)

Conversion instructions of 5/2 into


3/2 way function

5/2 way function (original mode of supply) 3/2 way function

5/2 3/2

7 6 7 6

3/2 resp. 5/2 way function according to version 6 Arrow


by swapping or turning enclosed adaptor plates. 7 Marker
Make sure Marker and Arrow do match as shown
on above drawing.

N/en/en 5.4.335.14 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
11/12
97105 NAMUR

Single connection plate Dimensions shown in mm

Model: 0612790 Projection/First angle

19 25,5 M 5 (4x) NAMUR slot (in connection


with 0612790 only)
Model: 0612791
19

25,5
G 1/4

35
19

41

16
11,5
30

16

51
12 12

9,5
34,5
104

5,5
9,5 19
41
5,5 G 1/4

5,5
29

12
19
12
10

5
11
9 27 21
14,5 60

Yoke Throttle control plate


Model: 0540593 Model: 4040239

19,5
15,5

2x
65
45
32

12
M5

12
50

41

76 4

5 20
8
25

12

M5
7,5

B B
15,5
15,5

A A

11/12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en/en 5.4.335.15
97105 NAMUR

Dimensions shown in mm
Projection/First angle

90 Mounting plate 270 Mounting plate Distance plate for


Model: 0613453 Model: 0613556 solenoids
Model: 0540109
19,5
32 32
15,5
16 9 16 9

3
12

3
12
12

12

45

58
32
24

12
1 2 24
12
1 2
12
24
26
20

20

50
7

M5 M5

20
24 20 24 9

7
12 12
M5

1 12

2 3
16

16
32

32
55

55
43,5

43,5

3 2
12 1
55 55

Manual override
Model: 0553886 Model: 0553887
14 14

~11 ~11
M10 x 0,5

M10 x 0,5

Model: 0613379
60
M10 x 0,5

17

77

N/en/en 5.4.335.16 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
11/12
97105 NAMUR

Silencer (plastic) Exhaust guard Dimensions shown in mm

Model: M/S2, M/S4, C/S2 & C/S4 Model: 0613422 & 0613423 Projection/First angle

C C
G G
D

B
B G C D Weight (g) Model B Suitable for G C D Weight (g) Model
G1/4 7 35,5 15,5 2,9 M/S2 1/4 G1/4, 1/4 NPT 10 26,5 21 5 0613422
1/4 NPT 7 35,5 15,5 2,9 C/S2 1/2 G1/2, 1/2 NPT 12 33,5 29 11 0613423
G1/2 12 67 23 11,5 M/S4
1/2 NPT 12 67 23 11,5 C/S4

Silencer (stainless steel)


Model: 0014613, 0014813, 0613678 & 0613679
B

G
C

B C G Weight (g) Model


G 1/4 36 8 16 23 0014613
1/4 NPT 36 8 16 67 0613678
G 1/2 49 12 24 81 0014813
1/2 NPT 49 12 24 235 0613679

Adaptor complete Inlet filter


Model: 0613487 Model: 0681173
4
3
1,5
G1/4

G1/4

10,5

13
8,5
19

60

21 14,5 8,5
28,5 5
60

Thread pitch diameter max. 11,85 mm

11/12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en/en 5.4.335.17
97105 NAMUR

Dimensions shown in mm
Cable gland
Projection/First angle

C C A B C D Model
B D B D M20 x 1,5 9 36 5 ... 8 22 0588819
M20 x 1,5 6,5 27,5 9 ... 13 22 0589385
M20 x 1,5 14 39 10 ... 14 24 0588851
A

A
1/2-14 NPT 15 58 7,5 ... 11,9 24 0588925
M20 x 1,5 14 39 7 ... 12 24 0589395
0588925 only M20 x 1,5 10 34 10 ... 14 24 0589387

Warning
These products are intended for use in industrial compressed air equipment in the event of such failure.
systems only. Do not use these products where pressures and System designers must provide a warning to end users in the system
temperatures can exceed those listed under Technical features. instructional manual if protection against a failure mode cannot be
adequately provided.
Before using these products with fluids other than those specified,
for non-industrial applications, life-support systems, or other ap- System designers and end users are cautioned to review specific
plications not within published specifications, consult NORGREN. warnings found in instruction sheets packed and shipped with these
Through misuse, age, or malfunction, components used in fluid products.
power systems can fail in various modes. Functional safty according to DIN EN 61508 SIL:
The system designer is warned to consider the failure modes of Suitable for certain applications can only be evaluated through
all component parts used in pneumatic systems and to provide examination of each safety-related overall system with regard to the
adequate safeguards to prevent personal injury or damage to requirements of IEC 61508 / 61511.

N/en/en 5.4.335.18 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
11/12

You might also like