You are on page 1of 1

LEGEND : 1.

UN FORMED SURFACE CAST AGAINST EARTH - 3"


LAP SCHEDULE CONT. -
-
CONTINUOUS 2. CONCRETE NOT EXPOSED TO EARTH OR WEATHER
4000 PSI (CLASS-B) CASE - 1 ADDL. ADDITIONAL #5 OR SMALLER 1-1/2"
REINF. - REINFORCEMENT
REF. - REFER #6 OR LARGER 2"
LENGTHS 3. CONCRETE NOT EXPOSED TO EARTH OR WEATHER
FTG. - FOOTING
BAR# TOP OTHERS TYP. - TYPICAL SLABS, WALLS, JOISTS 3/4"
DWGS. - DRAWINGS BEAMS (STIRRUPS AND MAIN REINF.) 1-1/2''
#3 2'-0" 1'-7"
VERT. - VERTICAL 4. USED 40'-0" STOCK LENGTH
#4 2'-8" 2'-1" T & B. - TOP AND BOTTOM
B/FTG. - BOTTOM OF FOOTING A/E/C PLEASE VERIFY ALL DIMENSION(S)
#5 3'-4" 2'-7" ADDL - ADDITIONAL
DT - DATED AND/OR CLOUDED AREA(S) SHOWN.
#6 4'-0" 3'-1" NOTE:-
E.W. - EACH WAY
#7 5'-10" 4'-6" DWLS. - DOWELS THE CONTRACTOR WILL NEED TO
#8 6'-8" 5'-2" T/PIER - TOP OF PIER FIELD ADJUST TO SUIT. (TYP)
EL. - ELEVATION
#9 7'-7" 5'-10" BOT. -
COVENANT
BOTTOM
#10 8'-6" 6'-7" STPS. - STIRRUPS VA 23111
#11 9'-5" 7'-3" T/SOG. - TOP OF SLAB ON GRADE
SEC. - SECTION
ALL TOP BARS ARE DEFINED AS SW. - SHORT WAY NAGENDRA
LW. - LONG WAY
HORIZ BARS WITH MORE THAN
12" OF CONCRETE BELOW BARS.
FOR APPROVAL 0 FOR APPROVAL
--- --/--/-- R1

You might also like