HVAC Basics Module 01

Multiple Choice Questions

Name: Date: 27th Dec. 2016

1) What does HVAC stand for? 7) HVAC is being used in Pharma to protect?
a. Humidification, Ventilation & Air
a. Product only
Cooling
b. Heat, Ventilation & Air Cooling b. Product & Personnel
c. Heating, Ventilation & Air
c. Product & Environment
Conditioning
d. Heat, Ventilation & Air Conditioning d. Product, Personnel & Environment
Which of the following are NOT related to
2) What does CFM stand for? 8)
HVAC?
a. Cubic foot per minute a. Avoid Fume Discharge to Environment
b. Cubic feet per minute b. Environment Protection
c. Cubic foot per meter c. Energy Efficiency
d. Cubic feet per meter d. None of these
In a "Bio-Pharma" facility, which of the
3) What does ADP stand for? 9) following is not recommended for personnel
movements in area classification?
a. Air Differential Pressure a. Movement across Class B to Class D
b. Air Dew Point b. Movement across Class C to Class D
c. Apparatus Dew Point c. Movement across Class B to CNC
d. AHU Differential pressure d. None of these
Which of the following standard
In a "Bio-Pharma" facility, which of the
4) deals in Fresh Air Requirement in 10)
following is not required in HVAC
general facility?
a. ASHRAE 90.1 a. Fire & Smoke Management
b. ASHRAE 62.2 b. Fresh Air in Process Room
c. ASHRAE 189.1 c. Air velocity
d. None of these d. None of these
Which of the following are NOT
5) 11) Psychometric Chart does NOT deal with?
dealt by HVAC
a. Noise a. Humidity Ratio
b. Vibration b. Entropy
c. Fire Safety c. Sensible Heat Factor
d. None of these d. Heating Process
In Psychometric Chart, when DBT is equal to
6) What does IAQ stand for? 12)
WBT?
a. Internal Air Quality a. RH = 100 %
b. Indoor Air Quality b. RH = 90%
c. Internal Air Qualification c. RH = 55%
d. Indoor Air Qualification d. None of these

Page 1 of 2
HVAC Basics Module 01
Multiple Choice Questions

Name: Date: 27th Dec. 2016

In Psychometric Chart, which of In a "Bio-Pharma" facility, Air-cooled Chiller


13) 17)
the following cant be plotted? must be placed at
a. Fresh Air a. Any Floor
b. Supply Air b. Any enclosed area
c. Mixed Air c. Any open space
d. Exhaust Air d. Terrace
In a "Bio-Pharma" facility, which of the
14) What does "CNC" stand for? 18) following is most energy efficient pumping
system?
a. Classified but Not Controlled a. Constant Primary Pumping
b. Controlled but Not Classified b. Constant Primary Variable Secondary Pumping
c. Classified and Controlled c. Variable Primary Pumping
d. None of these d. All have the same energy consumption

Air Changes of a Cleanroom grade In a "Bio-Pharma" facility, the heat recovery in


15) 19)
is? a treated fresh air Unit shall be done by?

a. Calculated a. Heat Recovery Wheel


b. Constant b. Cross Plate Type Heat Exchanger
c. Depends on the process area c. Any of these
d. None of these d. Both of these
In a "Bio-Pharma" facility, the fire or smoke
In Cascade Type Airlock, Pressure
16) 20) sensor in Supply Air & Return air path shall be
in airlock is
located with reference to Fire/smoke damper?
Higher than corridor, lower than
a. a. Before in supply air path. After in return air path
process room
Higher than process room, lower
b. b. After in supply air path & return air path
than corridor
Higher than both the process room
c. c. Before in supply air path & return air path
& corridor
Lower than both the process room
d. d. After in supply air path. Before in return air path
& corridor

Feedback:

Which topic you will like to include in next module?

Page 2 of 2