You are on page 1of 2

UT118A/B Operating Manual

Replace the battery as soon as the battery 2. HOLD


indicator appears. With a low battery, the Meter Press HOLD to enter and exit hold mode (except
UT118A/B Pen Type Meters might produce false readings that can lead to electric
shock and personal injury.
under auto scan mode).
Press and hold the HOLD button more than 2
W h e n s e r v i c i n g t h e M e t e r, u s e o n l y t h e seconds, the meter automatically holds the value
Operating Manual same model or identical electrical specifications
replacement parts.
which obtains at 6 seconds later, at this time, is
displayed and flickering.
The internal circuit of the Meter shall not be If enter sleep mode under hold mode, the meter still
Overview altered at will to avoid damage of the Meter and any in the hold mode when it be turned on.
This Operating Manual covers information on safety accident. 3. MAX/MIN
and cautions. Please read the relevant information Soft cloth and mild detergent should be used to The MAX/MIN mode stores minimum (MIN) and
carefully and observe all the Warnings and Notes clean the surface of the Meter when servicing. No maximum (MAX) input values (except under auto scan
strictly. abrasive and solvent should be used to prevent the mode). Manual ranging comes when you select this
surface of the Meter from corrosion, damage and function.
Warning accident. Press MAX/MIN button MAX MIN MAX/MIN
To avoid electric shock or personal injury, read the Do not use or store the Meter in an environment and vice versa.
"Safety Information" and "Rules for Safe Operation" of high temperature, humidity, explosive, inflammable Under hold mode and max/min mode, should exit hold
carefully before using the Meter. and strong magnetic field. The performance of the mode first then press and hold MAX/MIN more than 1
Meter may deteriorate after dampened. second to exit max/min mode.
The Model UT118A and UT118B (hereafter referred
4.
to as the Meter) are 3000 counts pen type digits International Electrical Symbols Display Backlight and test lead light button, Press
millimeters. The Meter uses large scale of integrated
Deficiency of Built-In Battery once to turn the display backlight and test lead light
circuit with professional multimeter IC as its core and
on and press again to turn the display backlight and
has full range overload protection.
Grounding test lead light off. It will automatically off after around
The Meter measures or tests the following:
AC (Alternative Current) 1 minute.
AC/DC voltage
5. AUTO POWER OFF
EF Function (UT118B only) DC (Direct Current)
To preserve battery life, the Meter automatically goes
Resistance Double Insulated into a sleep mode if you do not press any button for
Diode
Continuity Test around 10 minutes. The Meter can be activated by
Continuity
pressing any button, then returns to the display for the
Capacitance AC or DC
function selected previously
Diode 6. BUZZER
Unpacking Inspection Conforms to Standards of European The buzzer phonate go with every time button be
Open the package case and take out the Meter.
Warning. Refer to the Operating Manual effectual pressed. When the meter will auto power off
Check the following items carefully to see any
in 20 seconds the buzzer beeps three times. Before
missing or damaged part:
power off there will be a long time buzzer beeps.
Item Description Qty The Meter Structure (see figure 1)
1 English Operating Manual 1 piece
2 Test Lead 1 pair Measurement Operation
In the event you find any missing or damage, please Before measurement, anticlockwise circumgyrate the
red cover and rock the input terminal.
contact your dealer immediately. When all themeasurement has been completed,
Figure 1 deasil circumgyrate the red cover then hide the input
terminal. (see figure 3)
Safety Information 1. Front Housing 2. Functional buttons
This Meter complies with standards EN61010: in 3. Switch 4. LCD Display
pollution degree 2, over voltage category (CATIII 5. Input Terminals
300V) and double insulation.
CATIII: Distribution level, fixed installation, with Display Symbols (see figure 2)
smaller transient over voltages than CAT IV.
Use the Meter only as specified in this operating Figure 3
manual, otherwise the protection provided by the 1. AC / DC Voltage auto Measurement.
Meter may be impaired.
Warning
In this manual, a Warning identifies conditions
To avoid harm to the Meter, never input higher than
and actions that pose hazards to the user, or may
300V voltage although it is possible to measure
damage the Meter or the equipment under test.
higher voltage.
A Note identifies the information that user should pay
To measure Voltage, connect the Meter as follows:
attention on. Figure 2 Set the switch to V .
1. Indicates auto scan mode Auto measuremeng mode is a default. Under this
Rules For Safe Operation 2. High voltage indicator mode can measure AC voltage and DC voltage.
3 Data hold is active Connect the test leads across with the object
Warning 4. Indicates negative reading being measured. The measured value shows on
To avoid possible electric shock or personal injury, 5. The meter is in the autorange mode the display.
and to avoid possible damage to the Meter or to the 6. Indicator for AC voltage When voltage measurement has been completed,
equipment under test, adhere to the following rules: 7. Indicator for DC voltage disconnect the connection between the testing
Before using the Meter inspect the case. Do not 8. The battery is low leads and the circuit under test, and remove the
use the Meter if it is damaged or the case (or part testing leads away from the input terminal of the
of the case) is removed. Look for cracks or missing Warning: To avoid false readings, which could
lead to possible electric shock or personal injury, meter.
plastic. Pay attention to the insulation around the Note:
connectors. replace the battery as soon as the battery indicator
appears. The threshold voltage of AC voltage is around 400mV.
Inspect the test leads for damaged insulation or
exposed metal. Check the test leads for continuity. 9. Minimum reading.
10. Maximum reading. 2. DC Voltage Measurement
Replace damaged test leads with identical model
number or electrical specifications before using the 11. The unit of Capacitance Warning
Meter. 12 Test of diode To avoid harm to the Meter, never input higher than
When using the test leads, keep your fingers 13. The continuity buzzer is on. 300V voltage although it is possible to measure
behind the finger guards. 14. V : Volts. The unit of voltage. higher voltage.
Do not apply more than the rated voltage, as mV : Millivolt. 1x10 -3 or 0.001 volts. Set the switch to V .
marked on the Meter, between the terminals or 15. : Ohm. The unit of resistance Press SELECT to select DC voltage measurement
between any terminal and grounding. k : kilohm. 1x10 3 or 1000 ohms. mode.
When the Meter working at an effective voltage M: Megaohm. 1x10 6 or 1,000,000 ohms Connect the test leads across with the object
over 60V DC or 30V AC, special care should be being measured. The measured value shows on
taken for there is danger of electric shock. Button function and auto power off the display.
Use the proper function, and range for your 1.SELECT When voltage measurement has been completed,
measurements. Press SELECT to switch between resistance, AC/DC disconnect the connection between the testing
Disconnect circuit power and discharge all high voltage, continuity buzzer and diode measurement leads and the circuit under test, and remove the
voltage capacitors before testing current, resistance, modes. Press and hold more than 2 seconds in or testing leads away from the input terminal of the
diodes or continuity. exit sleep mode. meter.
UT118A/B Operating Manual

3. AC Voltage Measurement 8. Diodes Test E. Continuity Measurement


Range Resolution Remark
Warning Warning
Open Circuit Voltage around
To avoid harm to the Meter, never input higher than To avoid damages to the Meter or to the devices
0.1 -1.2V;Buzzer beeps at resistance
300V voltage although it is possible to measure under test, disconnect circuit power and discharge all
10; Buzzer not sound when
higher voltage. the high-voltage capacitors before measuring diodes.
resistance > 70;
Set the switch to V . To measure diode, do the following:
Press SELECT to select AC voltage measurement Set he rotary switch to .
F. Diodes Measurement
mode Press SELECT to select measurement mode
Range Resolution Overload Protection
Connect the test leads across with the object being For better accuracy, it better separate the object
measured. The measured value shows on the being measured from the circuit before 1mV 300Vrms
display. measurement. Remark: Open Circuit Voltage around 3V, Displays
When voltage measurement has been completed, When diodes measurement has been completed, approximate forward voltage drop.
disconnect the connection between the testing disconnect the connection between the testing
leads and the circuit under test, and remove the leads and the circuit under test. G. Capacitance
testing leads away from the input terminal of the Range Resolution Accuracy Overload Protection
meter. 9. Capacitance Measurement 3nF 0.001nF
Note: 30nF 0.01nF
Warning
The threshold voltage of AC voltage is around 400mV. 300nF 0.1nF (3%+5)
To avoid damage to the Meter or to the equipment 300Vrms
under test, disconnect circuit power and discharge 3F 1nF
4. EF Measurement( UT118B only) 30F 10nF
all high-voltage capacitors before measuring
Warning capacitance. Use the DC Voltage function to confirm 300F 100nF (5%+5)
To avoid harm to the Meter, never input higher than that the capacitor is discharged. 3mF reference
300V voltage although it is possible to measure To measure capacitance, connect the Meter as Remarks:
higher voltage. follows: 1. Under auto scan mode the max range is 300F.
Set the switch to V EF and remove the test lead Set he rotary switch to . 2. There is a residual reading when the circuit is open.
from the input terminal. Press SELECT to select measurement mode To measure a small value of capacitance, subtract it
Press SELECT to select EF measurement mode. For better accuracy, it better separate the object to ensure accuracy.
Unconnected measurement. Place the red being measured from the circuit before
terminals towards the object being measured. measurement. Maintenance (see figure 4)
When diodes measurement has been completed, This section provides basic maintenance information
5. auto measurement disconnect the connection between the testing and battery replacement instruction.
Warning leads and the circuit under test.
To avoid damages to the Meter or to the devices
under test, disconnect circuit power and discharge all General Specifications
the high-voltage capacitors before measurement. Maximum voltage between red Terminals and
Set the switch to . Grounding: 300Vrms.
Auto measuremeng mode is a default, under this Maximum Display: 3000. Updates 4 times/second
mode can measure Resistance, Diode, Continuity Temperature:
and Capacitance automatically. Operating: 0~40 (32~104);
For better accuracy, it better separate the object Storage: -10~50( 14~122).
being measured from the circuit before Relative Humidity: 75% @ 0~30; Figure 4
measurement. 50% @ 31~40 Warning
When voltage measurement has been completed, Altitude: Operating: 2000m; Storage: 10000m. Do not attempt to repair or service your Meter unless
disconnect the connection between the testing Battery Type: 3V Li-MnO2 Button cell battery you are qualified to do so and have the relevant
leads and the circuit under test. Battery Deficiency: Display . calibration, performance test, and service information.
Note: Dimensions (HxWxL): 20.18x26.5x181.5mm To avoid electrical shock or damage to the Meter, do
Under auto measurement mode, when input: Weight: Approx.90g (battery included). not get water inside the case.
Resistance: <15 or >10M
Capacitance: <400pF or >1mF Accuracy Specifications A. General Service
Will get an irresponsible value. Periodically wipe the case with a damp cloth and
Accuracy:(a% reading+b digits)guarantee for 1 year.
mild detergent. Do not use abrasives or solvents.
Operating temperature: 18 ~ 28.
6. Resistance Measurement To clean the terminals with cotton bar with
Relative humidity: <75%.
detergent, as dirt or moisture in the terminals can
Warning affect readings.
To avoid damages to the Meter or to the devices A . AC Voltage
Turn the Meter off when it is not use and take out
under test, disconnect circuit power and discharge Range Resolution Accuracy Overload Protection
the battery when not using for a long time.
all the high-voltage capacitors before measuring 3V 0.001V Do not store the Meter in a place of humidity,
resistance. 30V 0.01V (1%+4) 300Vrms high temperature, explosive, inflammable and
To measure resistance, do the following: 300V 0.1V strong magnetic field.
Set he rotary switch to .
Remark: Input Impedance: 10M
Press SELECT to select measurement mode. B. Replacing the Battery
Frequency Response: 40Hz ~ 400Hz
Connect the test leads across with the object being
Warning
measured.
B. DC Voltage To avoid false readings, which could lead to possible
When resistance measurement has been
Range Resolution Accuracy Overload Protection electric shock or personal injury, replace the battery
completed, disconnect the connection between the
testing leads and the circuit under test, and remove 3V 0.001V as soon as the battery indicator appears.
the testing leads away from the input terminals of 30V 0.01V (1%+3) 300Vrms To replace the battery:
the Meter. 300V 0.1V 1. Turn the Meter off. Disconnect the connection
between the testing leads and the circuit under test,
Remark: Input Impedance: 10M
7. Continuity Test and remove the testing leads away from the input
terminals of the Meter.
Warning C. EF Test (UT18B Only)
2. Remove the screw from battery compartment and
To avoid damages to the Meter or to the devices Range Remarks
separate the battery compartment from the case
under test, disconnect circuit power and discharge all <10mm: buzzer beeps;
bottom.
the high-voltage capacitors before continuity test. 220V/50H 10~50mm: may and may not beeps;
3. Remove the battery from the battery compartment.
To measure resistance, do the following: >50mm: Buzzer not sound
4. Replace the battery with a new 3V battery
Set he rotary switch to . D. Resistance
5. Rejoin the case bottom and the battery
Press SELECT to select measurement mode. Range Resolution Accuracy Overload Protection
compartment, and reinstall the screw.
Connect the test leads across with the object being 300 0.1
measured. 3k 1
The buzzer sounds continuously if the resistance (1%+3)
30k 10
of a circuit under test is30, it indicates the circuit
is in good connection. 300k 100 300Vrms
Note: 3M 1k
(1.5%+5)
When continuity measurement has been completed, 30M 10k
disconnect the connection between the testing leads Remark: Under auto scan mode the max range is
and the circuit under test, and remove the testing 3M.
leads away from the input terminals of the Meter Development District,Hu Men Town,Dong Guan City,
Guang Dong Province,China

You might also like