You are on page 1of 3

GHV30/10SV08F030T

Company Customer Date 2015-08-11


Contact Contact Item no.
Phone number Phone number Project
Email Email Project no.

Operating data
1 Pumpe ty pe Single-/Multi-pump set Fluid Water
2 No. of pumps / Reserv e 3 / 1 Operating temperature t A C 4
3 Nominal f low m/h 12 pH-v alue at t A 7
4 Nominal head m 85 Density at t A lb/f t 62.4
5 Static head m 0 Kin. v iscosity at t A mm/s 1.569
6 Inlet pressure bar 0 Vapor pressure at t A bar 0.0234
7 Env ironmental temperature C 20 Solids 0
8 Av ailable sy stem NPSH m 0 Altitude m 1000
Pump data
9 Pump designation Max. mm 96
10 GHV30/10SV08F030T Impeller designed mm 96
11 Design Electrical booster set Min. mm 96
12 Make Lowara Nominal m/h 12.1 ( 6 )
13 Flow Max- m/h 14
14 Speed 1/min 2900 Min- m/h
15 Number of stages 8 Nominal m 86.1
16 Max. working pressure bar 9.3 Head at Qmax m 44
17 Head H(Q=0) m 95 at Qmin m 95.3
18 Weight kg 330 Shaf t power kW 4.6 ( 2.3 )
19 Weight data include external package Max. shaf t power kW 5.8
20 Ef f iciency % 61.58
21 NPSH 3% m 1.2
Materials
22 Pump Motor data
23 Pump body AISI 304 Manuf acturer Lowara Electric v oltage 415 V
24 Pump outer sleev e AISI 304 Specif ic design IE3 Three phase surf ace motor
25 Manif olds Galv anized steel Ty pe PLM100.../330 E3 Electric current 5.82 A
26 On-of f v alv es Nickel-plated brass Rated power 3 kW Degree of protection IP 55
27 Non-return v alv es Brass Speed 2920 1/min Insulation class F
28 Pressure switches Chrome plated zinc alloy Frame size 100 Color RAL 5010
29 Pressure transmitters AISI 316 Weight 24 kg
30 Nipples/caps/plugs/f langes Galv anized steel
31 Bracket Painted steel
32
Standard options
33 Non return v alv e in deliv ery side
34 High pressure protection Without high pressure protection
35 Pipes ov ersize Standard
37 Suction side Standard
36 Panel protection degree IP 55
38 Voltometer Without v oltometer
39 Pressure gauge
40 Analogue dev ices Standard
41 Minimum pressure switch control Without pressure switch on suction side f or dry -running protection
42 No suction manif old Standard
43 Check v alv e Standard
44 Electrical panel Standard
45 :
46
47

Page 1 / 3
GHV30/10SV08F030T
Company Customer Date 2015-08-11
Contact Contact Item no.
Phone number Phone number Project
Email Email Project no.

Operating Data Specification Hydraulic data (duty point) Impeller design


Flow 12 m/h Flow 12.1 m/h Impeller R 96 mm
Head 85 m Head 86.1 m Frequency 50 Hz
Static head 0m Speed 2900 1/min

Power datas referced to:


Water [100%] ; 4C; 62.4lb/ft; 1.57mm/s
Perf ormance according to ISO 9906 - Annex A

[m] Head
Application range
104
100
96
92
88
86.1 m
84 1
80
76
72 Eff.
69.4%
68
64
60
56
52
48
44 10SV08 [Pump 1] 10SV08 [Pump 1+2]
40
36
32
28
24
20
16
12
8
4
0
[%] Efficiency
61.6 %
60 10SV08 [Pump 1] 10SV08 [Pump 1+2]
50
40
30
20
10
0
[m] NPSH-values 10SV08 [Pump 1] 10SV08 [Pump 1+2]
2.2
2.0
1.8
1.6
1.4
1.2 1.17 m
1.0
[kW] Shaft power P2
10SV08 [Pump 1+2] (P2)
5.5
5.0
4.5 4.59 kW
4.0
3.5
3.0 10SV08 [Pump 1] (P2)
2.5
2.0 12.1 m/h

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 [m/h]
GHV30/10SV08F030T
Company Customer Date 2015-08-11
Contact Contact Item no.
Phone number Phone number Project
Email Email Project no.

PLEASE NOTE:

Dimensions mm
A 301 H3 771
B 366 Weight (Include external package)
C 743 330 kg
D 1040
DNA R 2"1/2
DNM R 2"1/2
H 160
H1 748
H2 1132

You might also like