CALCULATION REPORTS - GABION ANALYSIS


Input data
Project
Task : DISEO MURO EN GAVION
Descrip : PARCELA EL TEJAR - VEREDA ACAPULCO - M/PIO DE FLORIDABLANCA (S/DER)
t.
Author : ING. GUILLERMO GALINDO GUERRERO - Mat. 68202-259950 STD
Date : 18/07/2015
Settings
USA - Safety factor
Wall analysis
Active earth pressure calculation : Coulomb
Passive earth pressure calculation : Mazindrani (Rankin)
DISEO MURO DE CONTENCION EN GAVION- QUEBRADA LA RUITOCA SECTOR FINCA EL TEJAR

VEREDA ACAPULCO - MUNICIPIO DE FLORIDABLANCA DEPARTAMENTO DE SANTANDER

ING. GUILLERMO GALINDO GUERRERO Mat. 68202-259950 STD

Earthquake analysis : Mononobe-Okabe


Permitted eccentricity 0.333
Shape of earth wedge : Calculate as skew
Verification methodology : Safety factors (ASD)
Safety factors
Permanent design situation
Safety factor for overturning : SFo = 1.50 []
Safety factor for sliding resistance : SFs = 1.50 []
Safety factor for bearing capacity : SFb = 2.00 []
Safety factor for mesh strength : SFn = 1.50 []

Reduction coefficients
Permanent design situation
Reduction coeff. of friction between blocks : gf = 1.50 []
Material of blocks - filling
g j c
No. Name
[kN/m3] [] [kPa]
1 PIEDRA RAJON 17.00 35.00 0.00
Material of blocks - mesh
Strength Spacing of Bear.cap.
No. Name overh. vert. meshes of front joint
Rt [kN/m] b [m] Rs [kN/m]
1 PIEDRA RAJON 40.00 1.00 40.00
Geometry of structure
Width Height Offset
No. Material
b [m] h [m] a [m]
3 2.00 1.00 1.00 PIEDRA RAJON
2 3.00 1.00 1.00 PIEDRA RAJON
1 4.00 1.00 - PIEDRA RAJON
Gabion slope = 0.00
Overall height = 3.00 m
Overall wall volume = 9.00 m3/m
Soil parameters
RELLENO
Unit weight : g = 19.00 kN/m3
Stress-state : effective
Angle of internal friction : jef = 30.00
Cohesion of soil : cef = 0.00 kPa
Angle of friction struc.-soil : d = 30.00
Soil : cohesionless
Saturated unit weight : gsat = 20.00 kN/m3
DISEO MURO DE CONTENCION EN GAVION- QUEBRADA LA RUITOCA SECTOR FINCA EL TEJAR

VEREDA ACAPULCO - MUNICIPIO DE FLORIDABLANCA DEPARTAMENTO DE SANTANDER

ING. GUILLERMO GALINDO GUERRERO Mat. 68202-259950 STD

LIMO ARENOSO
Unit weight : g = 19.00 kN/m3
Stress-state : effective
Angle of internal friction : jef = 25.00
Cohesin of soil : cef = 20.00 kPa
Angle of friction struc.-soil : d = 25.00
Soil : cohesionless
Saturated unit weight : gsat = 20.00 kN/m3

Geological profile and assigned soils


Layer
No. Assigned soil Pattern
[m]

1 4.00 RELLENO

2 - LIMO ARENOSO

FUNDATION
Type of foundation: Strip of foundation
Unit Weight of foundation: g = 24 kN/m3

Geometry of Foundation
Thickness: h = 0.20 m
Left shift: L = 0.20 m
Right shift: R = 0.20 m

Parameter foundation soil contact


Coefficient of friction: f = 0.577
Cohesion:: c = 20.00 kPa
Additional resistance: F = 0.000 kN/m3

Terrain profile
Terrain behind construction has the slope 1: 1.29 (slope angle is 37.80 ).
Embankment height is 4.81 m, embankment length is 6.20 m.

Water influence
Ground water table is located below the structure.

Input surface surcharges


Surcharge Mag.1 Mag.2 Ord.x Length Depth
No. Action
new change [kN/m2] [kN/m2] x [m] l [m] z [m]
1 YES permanent 15.00 6.22 20.00 on terrain
DISEO MURO DE CONTENCION EN GAVION- QUEBRADA LA RUITOCA SECTOR FINCA EL TEJAR

VEREDA ACAPULCO - MUNICIPIO DE FLORIDABLANCA DEPARTAMENTO DE SANTANDER

ING. GUILLERMO GALINDO GUERRERO Mat. 68202-259950 STD

No. Name
1 CARGA#1
Resistance on front face of the structure
Resistance on front face of the structure is not considered.
Settings of the stage of construction
Design situation: permanent

Verification No. 1
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -1.28 153.00 2.39 1.000
Active pressure 72.99 -1.10 42.14 4.00 1.000
CARGA#1 12.36 -1.51 7.13 4.00 1.000

Verification of complete wall


Check for overturning stability
Resisting moment Mres = 562.59 kNm/m
Overturning moment Movr = 98.62 kNm/m

Safety factor = 5.70 > 1.50


Wall for overturning is SATISFACTORY

Check for slip


Resisting horizontal force Hres = 196.71 kN/m
Active horizontal force Hact = 85.34 kN/m

Safety factor = 2.30 < 1.50


Wall for slip is SATISFACTORY

Forces acting at the centre of footing bottom


Overall moment M = -59.42 kNm/m
Normal force N = 202.27 kN/m
Shear force Q = 85.34 kN/m
Overall check - WALL is SATISFACTORY

Bearing capacity of foundation soil


Forces acting at the centre of the footing bottom
Moment Norm. force Shear Force Eccentricity Stress
No.
[kNm/m] [kN/m] [kN/m] [m] [kPa]
1 -59.42 202.27 85.34 0.00 50.57
DISEO MURO DE CONTENCION EN GAVION- QUEBRADA LA RUITOCA SECTOR FINCA EL TEJAR

VEREDA ACAPULCO - MUNICIPIO DE FLORIDABLANCA DEPARTAMENTO DE SANTANDER

ING. GUILLERMO GALINDO GUERRERO Mat. 68202-259950 STD

Bearing capacity of foundation soil check


Eccentricity verification
Max. eccentricity of normal force e = 0.0 mm
Maximum allowable eccentricity ealw = 1320.0 mm
Eccentricity of the normal force is SATISFACTORY

Footing bottom bearing capacity verification


Max. stress at footing bottom s = 50.57 kPa
Bearing capacity of foundation soil Rd = 300.00 kPa
Safety factor = 5.93 > 2.00
Bearing capacity of foundation soil is SATISFACTORY

Overall verification - bearing capacity of found. soil is SATISFACTORY

Dimensioning No. 1
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -0.90 85.00 1.70 1.000
Active pressure 37.24 -0.68 21.50 3.00 1.000
CARGA#1 8.29 -1.00 4.79 3.00 1.000

Verification of construction joint above the block No.: 1


Check for overturning stability
Resisting moment Mres = 223.36 kNm/m
Overturning moment Movr = 33.59 kNm/m

Safety factor = 6.65 > 1.50


Joint for overturning stability is SATISFACTORY

Check for slip


Resisting horizontal force Hres = 77.92 kN/m
Active horizontal force Hact = 45.53 kN/m

Safety factor = 1.71 > 1.50


Joint for slip is SATISFACTORY

Forces acting at the centre of footing bottom


Overall moment M = -22.84 kNm/m
Normal force N = 111.29 kN/m
Shear force Q = 45.53 kN/m
Maximum pressure on the bottom block = 37.10 kPa
Red.Coeff. by offset of top block = 0.00
DISEO MURO DE CONTENCION EN GAVION- QUEBRADA LA RUITOCA SECTOR FINCA EL TEJAR

VEREDA ACAPULCO - MUNICIPIO DE FLORIDABLANCA DEPARTAMENTO DE SANTANDER

ING. GUILLERMO GALINDO GUERRERO Mat. 68202-259950 STD

Average value of pressure on face = 2.96 kPa


Shear force transmitted by friction = 51.95 kN/m

Bearing capacity against transverse pressure:


Joint bear.capacity = 40.00 kN/m
Computed stress-state = 1.48 kN/m

Safety factor = 26.99 > 1.50


Transverse pressure check is SATISFACTORY

Joint btw. blocks check:


Mesh material bear.capacity = 40.00 kN/m
Computed stress-state = 1.48 kN/m

Safety factor = 26.99 > 1.50


Joint between blocks is SATISFACTORY

Name Fhor App.Pt. Fvert App.Pt. Design


[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -0.50 34.00 1.00 1.000
Active pressure 9.51 -0.33 5.49 2.00 1.000
CARGA#1 4.17 -0.50 2.41 2.00 1.000

Verification of construction joint above the block No.: 2


Check for overturning stability
Resisting moment Mres = 49.79 kNm/m
Overturning moment Movr = 5.26 kNm/m

Safety factor = 9.47 > 1.50


Joint for overturning stability is SATISFACTORY

Check for slip


Resisting horizontal force Hres = 29.34 kN/m
DISEO MURO DE CONTENCION EN GAVION- QUEBRADA LA RUITOCA SECTOR FINCA EL TEJAR

VEREDA ACAPULCO - MUNICIPIO DE FLORIDABLANCA DEPARTAMENTO DE SANTANDER

ING. GUILLERMO GALINDO GUERRERO Mat. 68202-259950 STD

Active horizontal force Hact = 13.68 kN/m

Safety factor = 2.14 > 1.50


Joint for slip is SATISFACTORY

Forces acting at the centre of footing bottom


Overall moment M = -2.64 kNm/m
Normal force N = 41.90 kN/m
Shear force Q = 13.68 kN/m
Maximum pressure on the bottom block = 20.95 kPa
Red.Coeff. by offset of top block = 0.00
Average value of pressure on face = 2.96 kPa
Shear force transmitted by friction = 19.56 kN/m

Bearing capacity against transverse pressure:


Joint bear.capacity = 40.00 kN/m
Computed stress-state = 1.48 kN/m

Safety factor = 26.99 > 1.50


Transverse pressure check is SATISFACTORY

Joint btw. blocks check:


Mesh material bear.capacity = 40.00 kN/m
Computed stress-state = 1.48 kN/m

Safety factor = 26.99 > 1.50


Joint between blocks is SATISFACTORY