Professional Documents
Culture Documents
from AC&E. We trust that you will find this booklet helpful in sourcing the products you require.
Founded in 1967, Australian company AC&E has become a leading manufacturer and supplier of
connectivity and interface solutions to the telecommunications, networking, audio/video and
Broadcasting Industries. With sales in 64 countries around the world, AC&E catalogue and
customized solutions are well recognized.
Since its inception, AC&E has specialised in the development and manufacture of products such
as:
Please feel welcome to visit our web site, www.acande.com or contact our
office (address details on the back cover) with any enquiries you may have.
We look forward to assisting you with your requirements and providing a
solution to your connectivity and interface needs.
Page 2 www.acande.com
Table of Contents
Baluns 4
Introduction 4
Telecommunications Applications 5
Benefits in Converting DDF from Coax to Twisted Pair 5
Generic Single Balun Part Numbering 6
Generic Balun Panel Part Numbering 7
Electrical Characteristics of 2-8Mbits/s, 75/120 Balun 8
Electrical characteristics of 34-155Mbits/s 75/120 Balun 9
Standard Baluns 10
Standard Baluns Physical Characteristics 10
2-8 Mbits/s 75/120 Transmission Baluns 10
2,8 & 34 Mbits/s 75/120 Transmission Baluns 11
Standard Baluns Termination Procedure 12
Mini Baluns 13
2-8 Mbits/s 75/120 Transmission Baluns 13
2,8 & 34 Mbits/s 75/120 Transmission Baluns 14
34-155Mbits/s high speed Mini Balun 14
Mini Balun Termination Procedures 15
Dual Baluns 16
2-8 Mbits/s 75/120 Transmission Baluns 16
34-155Mbits/s high speed Mini Balun 16
Dual Balun Cables 17
Balun Panels 18
Ultra High Density Balun Panels 18
High density balun Panels 19
Medium Density Balun Panels 19
Telco Connector Balun Panels 20
Low Density Balun Panels 20
Patch Panels 21
Patch Panel Solutions 21
Blank Panels 21
BNC Panels & Accessories 21
1.6/5.6 Panels & Accessories 21
Customised Requirements 21
Balun Cables 24
DDF Solutions 25
Video Baluns 26
Broadband Distribution Systems 27
Notes 28
Glossary 31
www.acande.com page 3
Baluns - Introduction
An unmatched source and load in a transmission system causes poor energy transfer from
one part of the system to the next. Baluns are the ideal solution to this problem as they allow
two systems of different characteristic impedance to each see their ideal load and source
impedance. This avoids losses caused by mismatch and allows full coupling of the transmitted
energy from one part of the system to the next.
A common transmission impedance matching problem is interfacing systems with a 75:
impedance (typical of many coaxial cables) to systems with a 120: impedance (as in many
twisted pair cables). There are many other impedances used in transmission systems.
Many modern transmission systems are designed with twisted pair interfaces as they offer
higher density interfaces, smaller cable sizes and lower cable costs. The incompatibility with
older established 75: systems is overcome with Baluns allowing equipment with different
interfaces to co-exist without penalty.
AC&E is a company that specializes in connectivity and interface solutions. We design and
produce a wide range of Baluns that support transmissions from DC to 1GHz in a variety of
connectivity standards and physical configurations that are intended for many different
applications.
In addition AC&E manufacture baluns in six main housing styles with a wide variety of
coaxial and twisted pair interfaces. Coaxial connector types supported include BNC, 1.6/5.6,
BT43, 1.0/2.3, APT1000, SMB, PAL, F and BPO10 connectors in male (m), female (f) and a
variety attachment styles. Twisted pair terminations include Krone IDC, AC&Es clamp IDC,
Screw Terminal, Wire Wrap, Pin Header, Telco, D Connectors and RJ45s.
Reliable long life connections with impedance matching is our business. Our connectivity
and interface solution guarantees your signal integrity.
This document lists the range of AC&Es catalogue Balun products and is intended as a
selection guide. Its contents are subject to change without notice. Our design team is well
experienced in quickly producing products to solve a special connectivity and interface problem.
Balun Housing
The most common housings for AC&Es Catalogue Balun products are:-
x The Standard Balun which is intended for panel mounting and comes
with a variety coaxial interfaces and has an industry standard Krone
IDC for twisted pair connection. This product is used to house Baluns
for use in the 0 50Mhz signal range.
B13603010
x The Mini Balun, a fully shielded product which is intended for either
panel or cable mounting, comes with a variety coaxial interfaces and
AC&Es Clamp IDC for twisted pair termination. This product houses
Baluns for use in the 0 250Mhz signal range.
x The PCB Balun which is intended for use by equipment makers who
need a PCB mounting 75: coaxial interface on their system. The
benefit of this solution is that it incorporates impedance
transformation and isolation within the same connector footprint.
B04002060
x The Broadband Balun is a product whose packaging is optimized for
use in impedance matching 50 1,000MHz signals for CATV
networks.
Page 4 www.acande.com
x Dual Baluns. These products provide transformation of a 75:
coaxial Tx/Rx pair to two 120: twisted pair outputs on a single
RJ45 socket. The product is primarily aimed at interfacing T1/E1 to
T3/E3 transmissions.
M1300921R2
x Balun Panels. These products house multiple Standard or Mini Baluns for users who require
a high density of Baluns. The convenience and cost saving of a 19 or similar instrument
rack in large and professional systems makes these products a popular choice.
Telecommunications Applications
AC&Es range of Baluns for telecommunications supports data speeds up to 155Mbit/s and meets or
exceeds all the parameters of the ITUG.703 specifications. These Baluns comprise of three
Catalogue types:-
Conversion from coax to twisted pair cables enables the use of high density IDC (insulation
displacement connection) modules to be used for distribution frames, increasing the wiring density
by more than 5 times, effectively reducing the space requirement to 1/5 or less. This creates space
within the exchange for the installation of additional lines and facilities.
Australias major telecommunication carrier has accomplished the conversion of all their 2 and
8Mbit/s Digital Distribution Frames (DDF) from coaxial to twisted pair cabling using Baluns supplied
by AC&E. This has achieved substantial multi-million dollar savings. It is our understanding that this
carrier wishes to convert all their coaxial system within their exchanges to run on twisted pair cables
for data rates covering 34, 45, 140 and 155Mbit/s, and AC&E is providing the necessary components
for them to do so. AC&E is well acquainted with the technology to help any other telecommunications
organisation considering the advantages of such an exercise.
The maximum distances for twisted pair cables used in conjunction with the Baluns will depend on
the grade of cables being used and the number of twists per unit length. Typical distances on good
quality cables will be 300 metres and 160 metres respectively for 2Mbit/s and 8Mbit/s using the
existing Baluns and 60 metres for 155Mbit/s with the new high speed Baluns.
3. Use of smaller, low cost twisted pair cables enables easier cable routing and management.
4. Quick and easy termination of twisted pair wires saves material and labour cost.
6. Full solution for migrating from old technology to new 120: structure.
www.acande.com page 5
Generic Single Balun Part Numbering
AC&E single Baluns identified in this catalogue conform to the part numbering standard
identified on this page. Part numbers not defined generally are customer specific types. This
table is useful for quickly selecting products but please request a data sheet to check all
specifications and user data before purchasing products.
eg. B04 003 060 Balun 2,8,34Mbit/s, 1.6/5.6 (f), Clamp IDC 0.5 to 0.65 wire
B13 019 010 Balun 2,8Mbit/s, BNC (f) 75Ohm Bulkhead, 3 pole IDC (Krone)
B08 044 065 Balun 34 to 155Mbit/s, 1.0/2.3 (f) Bulkhead, Clamp IDC 0.3 to 0.4 wire
Page 6 www.acande.com
Generic Balun Panel Part Numbering
Panel Matrix - zz
96 Coax and Baluns to 48 Twisted Pair Connectors 98
48 Coax and Baluns to 24 Twisted Pair Connectors 44
32 Coax and Baluns to 16 Twisted Pair Connectors 36
32 Coax and Baluns to 2 Twisted Pair Connectors 32
16 Coax and Baluns to 8 Twisted Pair Connectors 18
2 Coax and Baluns to 1 Twisted Pair Connector 21
Configuration - pp
RJ45, 1 RU, 19 Rack Black, wired 1245, 2 sided R1
RJ45, 2 RU, 19 Rack, Black, wired 1245, all connectors one side R6
Telco connector, 2RU 19 Rack Black, fixed wiring, 2 sided T1
www.acande.com page 7
Electrical Characteristics of 2-8Mbit/s, 75/120: Balun
Page 8 www.acande.com
34Mbit/s pulse performance
and G.703 pulse spec mask
Typical return loss and G.703
minimum performance levels for
2, 8 and 34Mbit/s
www.acande.com page 9
Standard Baluns
Physical Characteristics
x Intended for panel mounting and can be supplied with a variety B04025010
of Coaxial Connectors BNC, 1.6/5.6, Type43, BPO10 etc
x Twisted pair termination via 3 pole Krone IDC 3
x The insertion loss from both sides is < 0.2dB for 2Mbit/s and < 0.3dB for 8Mbit service.
x Cross talk between any two baluns mounted on a DDF strip with 15mm centres is better than
-80dB in the frequency range of 0.1MHz to 12MHz.
x Return loss is 29dB(typ) for 2Mbit/s and 21dB(typ) for 8Mbit/s service
Page 10 www.acande.com
Black Balun Order Codes
Part No Description
B04 001 010/N 1.6/5.6 (m) snap to 3 pole Krone IDC
B13 002 010 1.6/5.6 (m) screw to 3 pole Krone IDC
B13 003 010 1.6/5.6 (f) to 3 pole Krone IDC
B04 025 010/N 1.6/5.6 (m) Rt. angle snap to 3 pole Krone IDC
B13 008 010 BNC (m) to 3 pole Krone IDC
B04 009 010 BNC (f) to 3 pole Krone IDC
B04 028 010 BNC (m) Rt. angle to 3 pole Krone IDC
B13 019 010 BNC (f) bulkhead to 3 pole Krone IDC
x The value of the impedance match is 75 10: resistive to 120 12: resistive, when
measured at 1 to 17MHz and with the unused end terminated into the respective resistive
load.
x The insertion loss less than 0.9dB is in the range 0.2MHz to 70MHz from both sides.
x Cross talk between any two baluns mounted on a DDF strip is better than -60dB with
vertical orientation of IDC connectors in the range of 1MHz to 70MHz
x Return loss is better than -15dB in the frequency range of 1MHz to 70MHz in both
directions of transmission conforming to ITU-G.703.
x Transmission losses for cable are excluded
APPROX. 25mm
Page 12 www.acande.com
Mini Balun Series
Mini Baluns are ideal in applications where size and space are
restricted due to their small dimensions. They are intended for panel
or cable mounting and feature AC&Es clamp IDC termination allowing
installation without special tools.
They are fully shielded and offer EMC compatibility and EMI
compliance as well as excellent high data rate performance. They are B04044060
available in three speed ranges, 2-8Mbit/s, 2-8-34Mbit/s or 34 to
155Mbit/s.
Order Codes
Part Number Description
B13 001 060 1.6/5.6 (m) Straight Snap Coupling
B13 002 060 1.6/5.6 (m) Straight Screw Coupling
B13 003 060 1.6/5.6 (f) Straight Bulkhead
B13 008 060 BNC (m) Straight
B13 019 060 BNC (f) Straight Bulkhead
B13 043 060 1.0/2.3 (m) Straight Posi-lock Coupling
B13 044 060 1.0/2.3 (f) Straight Bulkhead
B13 046 060 Type 43 (f) Straight Posi-lock Coupling
B13 048 060 Type 43 (m) Straight Bulkhead Fixed Mounting
B13 049 060 Type 43 (m) Straight Bulkhead Floating Mounting
B13 052 070 Type 43 HDC (m) Straight Floating Mounting
B13 078 060 SMB (f) In-line Coupling
B13 085 060 SMB (f) Rt. Angle Coupling
(0.50 to 0.65mm wire types listed, for 0.24 to 0.40 wire p/n last digit 0 becomes 5)
www.acande.com page 13
Customer Codes for 2-8Mbit/s Mini Baluns
Part No Specifier Description
NTUM98LA Nortel Mini Balun Pair, 1.6/5.6 (m) Straight Screw Coupling
NTQG41GA Nortel Mini Balun Pair , BNC (m) Straight
NTUM 98YA Nortel Mini Balun Pair, Type 43 (m) Str Bulkhead Floating Mounting
67356-10/196 Marconi Mini Balun, 1.0/2.3 (m) Straight Posi-Lock Coupling
5105189-0013 Marconi Type 43 (m) Straight Bulkhead Floating Mounting
5105191-0019 Marconi Type 43 HDC (m) Str Bulkhead Floating Mounting
CS73426.08 Nokia 1.0/2.3 (f) Straight Bulkhead
CS73426.09 Nokia BNC (M) Straight
Customer Codes
Part No Specifier Description
848 341 756 Lucent 1.6/5.6 (m) Straight Screw Coupling
848 341 722 Lucent 1.6/5.6 (f) Straight Bulkhead
848 341 780 Lucent BNC (m) Straight
848 341 798 Lucent BNC (f) Straight Bulkhead Mounting
848 341 673 Lucent APT 1000 (m) StrBulkhead Fixed Mtg with Locking Bush
848 341 806 Lucent 1.0/2.3 (m) Straight Posi-lock Coupling
848 341 814 Lucent 1.0/2.3 (f) Straight Bulkhead
848 341 822 Lucent Type 43 (f) Straight Posi-lock Coupling
848 341 830 Lucent Type 43 (m) Straight Bulkhead Fixed Mounting
848 536 793 Lucent 1.6/5.6 (f) Monitored Balun U Link 20dB
848 746 558 Lucent Type 43 (m) Straight Bulkhead Floating Mounting
848 746 566 Lucent Type 43 HDC (m) Straight Bulkhead Floating Mount
Order Codes
Part No. Description
B08 002 065 1.6/5.6 (m) Straight Screw Coupling
B08 003 065 1.6/5.6 (f) Straight Bulkhead
B08 008 065 BNC (m) Straight
B08 019 065 BNC (f) Straight Bulkhead
B08 043 065 1.0/2.3 (m) Straight Posi-lock Coupling B08044065
B08 044 065 1.0/2.3 (f) Straight Bulkhead
B08 046 065 Type 43 (f) Straight Posi-lock Coupling
B08 052 075 Type 43 (m) HDC Straight Floating Mounting
(0.24 to 0.40mm wire types listed, for 0.50 to 0.60
(0.32 0.65 wire p/n last digit 5
'5' becomes
becomes'0')
0)
Page 14 www.acande.com
Mini-Balun Termination Procedure
Cable examples
- 060 IDC 26-28AWG Filotex ET2PBB010 (8 pair or similar) or Lucent Technologies 848 317 673.
- 065 IDC 22-24AWG Belden JPMD06AAH0011
3. Strip the cable jacket to B from the end of the cable. Cut the drain
wire and foil A from the end of the cable.
4. Flare the foil and fold it and the drain wire back over the sheath.
Fit the grounding ring over the end of the cable.
5. Insert the wires into the holes in the small end of the stuffer cap
marked A and B.
7. Ensure that the end of each conductor is positioned behind the lip
and into the cavity at the end of the slot, as per illustration.
8. Fold the foil and the drain wire back over the outside of the stuffer cap.
Ensure the drain wire ends within the tapered section of stuffer cap.
9. Orient the tongue on the mini-balun to line up with the flat on the
stuffer cap and insert the stuffer cap onto the IDC terminals. Ensure
that the wires are correctly positioned in the slots (Refer to 7 above).
10. Pull the rear outer body forward and align the flat to the tongue in
the Mini-Balun body. Secure the retaining nut finger tight. Lightly
tighten using the spanners recommended.
www.acande.com page 15
Dual Balun
This module contains 2 Coaxial Connectors, 2 Baluns and 1 RJ45
socket housed in an insulated enclosure. It is intended to convert an
E1/T1 Channel consisting of 1 Transmit and 1 Receive signal from
75 coaxial to 2 x 120 twisted pair signals on an RJ45/Cat5 cable.
Order Codes
M1300921R2 Dual Balun, 2x BNC (f) to RJ45, 2 to 8Mbit/s, 75/120
M1300321R2 Dual Balun, 2x 1.6/5.6 (f) to RJ45, 2 to 8Mbit/s, 75/120
M1304921R2 Dual Balun, 2x BT43 (m) to RJ45, 2 to 8Mbit/s, 75/120
M1304421R2 Dual Balun, 2x 1.0/2.3 (f) to RJ45, 2 to 8Mbit/s, 75/120
Page 16 www.acande.com
PCB Baluns
Order Codes
A selection ofPart
AC&ENo Baluns are available
Description
housed in PCB mounting
B08 040 072
right angle coaxial connectors. Dual Balun, 2x BNC (f) to RJ45, 34 to 155Mbit/s, 75/120
B08 040 071 Dual Balun, 2x 1.6/5.6 (f) to RJ45, 34 to 155Mbit/s, 75/120
These products are intended for use by transmission equipment
B08 040 073 Dual Balun, 2x BT43 (m) to RJ45, 34 to 155Mbit/s, 75/120
designers who wish to take advantage
B08 040 080
of the space savings that an
Dual Balun, 2x 1.0/2.3 (f) to RJ45, 34 to 155Mbit/s, 75/120
integrated Connector/Balun provides.
Available in BNC, 1.6/5.6 and BT43 these PCB Baluns feature a
Dual
windingBalun
isolationCables
of 250V and are available with a 2-8Mbit/s,
Transmission Balun core. Other coaxial connectors and
AC&E's DualonBalun
impedances Cables provide the ideal
request.
connectivity and interface solution where space
is at a premium as they provide a solution with
or without a patch panel. Factory assembled
Mini Balun PCB
The AC&E CableBaluns
assemblies
offer theare supplied
following to
performance features:-
length as requested.
x Fully shielded
x Balun
Dual Available in BNC,
Cables 1.6/5.6 and BT43 coaxial connectors
Feature:
x Common PCB footprint
Compact
x DetaiIed panel less
electrical interface solution
characteristics on pages 8 and 9
Fully shielded interconnect
x 2-8Mbit/s Transmission Balun
Exceeds G.703 specified performance
x 75/120:
All Miniimpedance transformation
Baluns supported
Supplied
x Small size andwithrugged
cable boots for additional strain relief
construction
Catalogue types available
x Other Coaxial Connectors and from stock
impedances on request
Cables labeled TX & RX
x 2-8-34Mbit/s Transmission or Video Balun core on request
www.acande.com page 17
Dual
BalunBalun
Panels
This
AC&E'smodule
range contains
of Balun2 Coaxial Connectors,
panels are intended 2forBaluns and 1 RJ45
socket housed in an insulated enclosure.
converting 75 coaxial transmissions to 120 It is intended to convert an
balanced twisted pair signals. They are based on
E1/T1 Channel consisting of 1 Transmit and 1 Receive signal from
AC&E's
75: Mini
coaxial to 2Balun
x 120:technology
twisted pairwhich
signalsisonthe
an RJ45/Cat5 cable.
subject of a number of patent applications.
A common application is when new equipment
This module
designed withfeatures:-
twisted pair interfaces needs to be
connected to an established B04040072
x Fully shielded Circuitry coaxial environment.
AC&E's Balun Panels achieve such an interface
x Complies with EMC requirements.
with a minimum of electrical degradation and
x Insertion
exceed loss: for
ITU-G703 < 0.4dB
2-8Mbit/s transmissions (2-
x Return Loss: < -25dB on request).
8-34Mbit/s types available
Together with matching Patch Panels, Patch
x Interfaces two coaxial E1, 2Mbit/s paths into an RJ45 socket
Cables, U Links and Connectors AC&E offer a
x Specified
Complete for 2-8Mbit/s
Connectivity and use
Interface Solution.
x Other connectors available on request, e.g. SMB
The Provides
x extensive250Vrange of panels
isolation is available
from input to outputonterminals
short leadtime and features:- 19" Rack Mounted Balun Panels
x Insulated enclosures (BNC 37x37x28mm, Others 31x57x61mm)
x Matching
Up impedances
to 96 baluns in 1RU75 to 120:.
panel heightOthers
offers on request. limit packing density
mechanical
x 52-8-34Mbit/s versions
density varients and available on request
6 configurations available from stock range
Stocked types include BNC, 1.6/5.6, BT43, SMB and 1.0/2.3 coaxial connectors (others on request)
Order
Electrical Codes
Characteristics on page 8
B04 040 072 Dual Balun, 2x BNC (f) to RJ45, 2-8Mbit/s, 75/120:
Shielded construction gives excellent EMC performance
B04 040 071 Dual Balun, 2x 1.6/5.6 (f) to RJ45, 2-8Mbit/s, 75/120:
Internal shielding
B04 040 073gives low Dual
adacent channel
Balun, 2x BT43cross
(m) totalk < -80dB
RJ45, 2-8Mbit/s, 75/120:
Ultra thin
B04panel design (96 balun
040 080 45mm,
Dual Balun, 2x others
1.0/2.3 33mm) leaves
(f) to RJ45, more 75/120:
2-8Mbit/s, room for cable entry
Reversable panel allows coaxial or RJ45 side to be mounted to the front
Adjustable panel recess gives more cable entry space where required
High Speed Dual Balun 34 to 155Mbit/s
Zinc sealed, powder coated steel for rigidity and long life
Mounting brackets may be substituted to support other standards
This module offers two STM1 155Mbit/s paths (also
Matching Patch Panels and Blank Panels for a Complete Connectivity and Interface
140Mbit/s, 45Mbit/s or 34Mbit/s) into a single RJ45
Solution
socket from coaxial feeders. The module contains 2
Coaxial Connectors, 2 Baluns and 1 RJ45 socket
UltrainHigh
housed Density
an insulated enclosure.Balun Panel 96 Coax to 48 RJ45, 1RU, 75/120
Tx
Rx
Tx
Rx
Tx
Rx
Tx
x Pulse Shape: Meets ITU G.703 Mask at 34 and 155Mbit/s
Rx Rx Rx Rx
Page 18 www.acande.com
Order Codes
High Density
Part No
Balun Panel 48 Coax to 24 RJ45, 1RU, 75/120:
Description
B08 040 072 Dual Balun, 2x BNC (f) to RJ45, 34 to 155Mbit/s, 75/120:
B08 040 071 Dual Balun, 2x 1.6/5.6 (f) to RJ45, 34 to 155Mbit/s, 75/120:
B08 040 073 Dual Balun, 2x BT43 (m) to RJ45, 34 to 155Mbit/s, 75/120:
B08 040 080 Dual Balun, 2x 1.0/2.3 (f) to RJ45, 34 to 155Mbit/s, 75/120:
Rx Rx
Order codes
M13 009 36 R6 BNC (f) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
M13 003 36 R6 1.6/5.6 (f) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
M13 049 36 R6 BT43 (m) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
M13 044 36 R6 1.0/2.3 (f) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
www.acande.com page 19
Broadband
Telco Connector
Distribution
Balun Panel
System
32 Coax to 2x50way Telco, 1 RU, 75/120:
Home
Tx Tx
Order Code
Part No Description
VDS001 Broadband Distribution System with 4 outlets, 10 panel *
VDS002 Broadband Distribution System with 8 outlets, 10 panel *
VDS003 Broadband Distribution System with 4 outlets, 19 panel
Order Codes
VDS004 Broadband Distribution System with 8 outlets, 19 panel
M13 009 18 R6
VDPC01/2M BNC (f) to Broadband
RJ45, 1 Side, 2 RU,
Balun 75/120:,
patch 2-8Mbit/s
cord, 2m, PAL(m) to RJ45 UTP
M13 003 18 R6
VDPC02/2M 1.6/5.6 (f) to RJ45, 1 Side,
Broadband Balun2 patch
RU, 75/120:,
cord, 2m2-8Mbit/s
PAL (m) to RJ45 STP
VDSTERM
M13 049 18 R6 BT43 (m) to RJ45 Terminator
RJ45, 1 Side, 2 RU, 75/120:, 2-8Mbit/s
*10
M13 044 18 R6panel made according to Krone cabinet
1.0/2.3 (f) to RJ45, 1Side, 2 RU,sizes. Other 10
75/120:, sizes on request.
2-8Mbit/s
Page 20 www.acande.com
Patch Panel Solutions
AC&Es range of matching Patch Panels
complements the AC&E range of Balun panels
thus providing interconnect solution that is
highly functional and professional in
appearance. Constructed in zinc sealed, black
powder coated steel they are built for long life.
The Baluns, U Links, Through Adaptors and
Patch Cables listed on this page have been
designed with compatibility in mind and are
intended to be used in and on the patch panels
listed here to provide a complete connectivity
and interface solution.
Select your coaxial connectors from AC&Es
range of BNC, 1.6/5.6, BT43 and 1.0/2.3 listed
on the web for your total requirement.
STU D Y BE D R O O M BE D R O O M
Blank Panels
Order Codes - Blank Panels
Part No. Description
C o n c e a le d W irin g
JS1 Blank Blank Panel, 1 RU, 19, black powder coated steel
JS4 Blank Blank Panel, 2 RU, 19, black powder coated steel
10 RACK
M O U N TIN G
M O D U LE
BNC Panels & Accessories
LIVIN G A R E A K ITC H E N
Order Codes - BNC Panels
JS7/40 BNCU BNC panel,
BR O A2DxBA20,N2DRU,
D ISblack powder
TR IBU TIO N coated
SYSTEsteel,
M empty
JS3/20 BNCU BNC panel, 1 x 20, 1 RU black powder coated steel, empty
1.6/5.6
Size Panels & 88
Accessories
(2RU) x 254 x 185 (HxWxD)
Order
TypicalCodes
Cable 1.6/5.6 Panels
Lengths:
JS3/48
Cat. 5e 1656U 1.6/5.6 Panel, 2x24, 1 RU, black powder coated steel, empty, 15mm pitch
40m*
JS3P/48
Cat. 6 1656U 1.6/5.6
45m*Panel, 2x24, 1 RU, grey fibre reinforced plastic, empty, 15mm pitch
Order Codes
*Distance - 1.6/5.6
depends Panel
on the Accessories
input signal strength and the transmission characteristics of the cable used.
A001705 Through Adaptor 1.6/5.6 (f) to 1.6/5.6 (f) , uninsulated
Balun Select any 1.6/5.6 Standard or Mini Balun from this catalogue
A001702/15/1/N U Link 1.6/5.6 (m) - 1.6/5.6 (m) screw coupling, 15mm pitch
A001716/15/2/N U Link monitor Snap coupling rear entry monitor (f) 26db 15mm pitch
A001716/15/1/N U Link monitor Screw coupling rear entry monitor (f) 26db 15mm pitch
A001717/15/2/N U Link Bmonitor R J45coupling side TW
R O A D B A N DSnap ISTE D PA
entry IR
monitor (f) 26db R15mm
J45 pitch
BROAD BAND
C O AX IA L C A BL E A M PL IFIER B A LU N W ALL C AT 5e / 6 W ALL B A LU N
S250/1M/N Patch cable 1.6/5.6 (m)
SO C K ET - 1.6/5.6 (m), length
C A BLE 1m SO C K ET
www.acande.com page 21
Customised Balun Assemblies
Balun Panels
Following are examples of customer specific products that we have produced on request to solve
specific interface
AC&Es range needs.panels
of Balun You too can haveforyour specific needs addressed by AC&E, by
are intended
specifying
converting 75: coaxial transmissions to us
your own requirements. Contact by phone, fax or web to discuss your requirements.
120:
balanced twisted pair signals. They are based on
AC&Es Channel
Quad Mini Balun Balun technology which is the
Assembly
subject of a number
Order Code: B04 040 074 of patent applications.
Customer: Nokia
A common application is when new equipment
designed with twisted pair interfaces needs to be
Description:
connected
This Quad to an established
Channel coaxial environment.
Balun assembly has been developed for a
AC&Es
major Balun Panels
Worldwide achieve such an interface Equipment
Telecommunication
with a minimum of electrical
Manufacturer/Solutions degradation
Provider. and
The product features
exceed ITU-G703
miniature connectors for 2-8Mbit/s
(4x Type transmissions
SMB) and an(2-RJ45 socket.
8-34Mbit/s
This packagetypesis available
extremelyonsmall
request).
and is capable of handling
four channels at E1 (2.048Mbit/s)Panels,
Together with matching Patch Patch
or T1 (1.544Mbit/s) rates
and has an isolation voltage rating of 1.5KV DC. a
Cables, U Links and Connectors AC&E offer
Complete Connectivity and Interface Solution.
Features: B04040074
The extensive range of panels is available on
short leadtime 19 Rack Mounted Balun Panels
x The size is and
smallfeatures:-
for the purpose of converting 4 coaxial
transmission paths into one single RJ45 socket and
x packaging
Up to 96 baluns
these infunctions
1RU panel height
into offers mechanical
a volume of 31 x 33limitx packing density
x 43mm.
5 density varients and 6 configurations available from stock range
x
x Stockedcombinations
Various types include ofBNC,coaxial connector
1.6/5.6, BT43, SMB typesand
can be coaxial connectors (others on request)
1.0/2.3
incorporated into this design such as 1.6/5.6, Type 43,
x BNC,
Electrical Characteristics
1.0/2.3 on page 8of connector types can
and other variations
x be
Shielded construction gives
accommodated (size adjustment excellent isEMC performance
necessary to suit
size of coaxial connectors) upon request.
x Internal shielding gives low adacent channel cross talk < -80dB
x Corporate labeling can be arranged to suit major customer requirements. In addition, for the
x Ultra thin panel design (96 balun 45mm, others 33mm) leaves more room for cable entry
purpose of technician labeling an area for felt pen marking is provided.
x Low
x Reversable panel allows
losses. Insertion Loss:coaxial
< 0.5dBor and
RJ45 side to
Return be mounted
Loss: to the
better than front
20dB.
x Adjustable panel recess gives more cable entry space where required
x Zinc sealed, powder coated steel for rigidity and long life
x Mounting brackets may be substituted to support other standards
Connector, Integral Balun Pair
x Matching
Order Patch
Code: B04 023Panels
024 and Customer:
Blank Panels for Australia
Telstra a Complete Connectivity and Interface
Solution
Description:
Ultra High
Connector, Density
Integral Balun Pair, Balun Panel
75-120: (for 96 Coax
Ericsson ISDN to 48 RJ45, 1RU, 75/120:
PRA Interface) B04023024
Features:
x Allows unbalanced coaxial type 75: equipment to simply connect to 120: shielded twisted
pair. It provides interfacing to two separate circuits (a go and come path).
x Avoid more costly and space consuming 75: hardware for patching at the distribution frame.
x Minimal losses and distortion - refer Black Balun characteristics. (refer page 10).
Tx Tx Tx Tx
Rx Rx Rx Rx
x Low cost and optimal size form a simple design with minimal component count, being integral
Tx Tx Tx Tx
with existing connectors typically used in ISDN Interface Cards on AXE Systems.
Rx Rx Rx Rx
Page 22 www.acande.com
DB9 to Coaxial Connector
Highcode:
Order Density Balun
B10 003 Panelto 1.6/5.6
054 DB9(m) 48 Coax(f)to 24 Customer:
RJ45, 1RU,Lucent
75/120:
B10 048 054 DB9(m) to Type 43 (m) Customer: Lucent
Description:
A simple solution to the problem of converting a
2Mbit/s (E1) signal from twisted pair 120: to
coaxial 75: in one compact adaptor.
Description:
Panel assembly containing 16 x Type 43 male
Rx Rx Rx Rx
Single
Features:
Sided Balun Panel 32 Coax to 16 RJ45, 2RU, 75/120:
x Allows for earthing options for Tx and Rx paths.
x Identification strip which allows labelling of each
transmission path.
x A handle is provided on the assembly to allow it to be installed in a confined space as well as
provision for sealing the assembly within the System so that minimum exposure of the cables
is provided.
x The frame is only 155 x 45mm and 75mm deep. Refer to mini-baluns for mechanical and
electrical detail
Order codes
M13 009 36 R6 BNC (f) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
M13 003 36 R6 1.6/5.6 (f) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
M13 049 36 R6 BT43 (m) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
M13 044 36 R6 1.0/2.3 (f) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
www.acande.com page 23
Telco Connector
Balun Cable Assemblies
Balun Panel 32 Coax to 2x50way Telco, 1 RU, 75/120:
Tx Tx Tx Tx
Rx Rx Rx Rx
Order Codes
M13 009 32 T1 BNC (f) to 2x50way Telco, 1RU, 75/120:, 2-8Mbit/s
M13 003 32 T1 1.6/5.6 (f) to 2x50way Telco, 1RU, 75/120:, 2-8Mbit/s
M13 049 32 T1 BT43 (m) to 2x50way Telco, 1RU, 75/120:, 2-8Mbit/s
M13 044 32 T1 1.0/2.3 (f) to 2x50way Telco, 1RU, 75/120:, 2-8Mbit/s
Description:
A range of Balun Cable Assemblies are available with your selection of connector types at either
ends. Nominal Impedance ratios of 75 to 120: and bit rates are selectable from the Mini-baluns
Low Density
shown on page 13 of Balun PanelOn16the
this handbook. Coax to 8 RJ45,
balanced side1RU, 75/120: of single or multi-
a selection
connectors are available with various forms of mounting and/or shielding. The cable selection is
arranged in Characteristic Impedances and/or shielding cost benefits.
Optional cable labels and cable stress relief attachments are available
Order Codes
Examples:
M13 009 18 R1 BNC (f) to RJ45, 16x8, 1RU, 75/120:, 2-8Mbit/s
M13 003 18 R1 1.6/5.6 (f) to RJ45, 16x8, 1RU, 75/120:, 2-8Mbit/s
PtM13
No 049
S281/3M
18 R1 using
BT43B04
(m) 001 065 16x8,
to RJ45, to 1RU, 75/120:,
Pt2-8Mbit/s
No S440/1M using 2 x B04 003 065 to
Krone 4P on CBTP26301 RJ45 on STP Cat 5
M13 044 18 R1 1.0/2.3 (f) to RJ45, 16x8, 1RU, 75/120:, 2-8Mbit/s
Single Sided Balun Panel 16 Coax to 8 RJ45, single sided, 2RU, 75/120:
Order Codes
M13 009 18 R6 BNC (f) to RJ45, 1 Side, 2 RU, 75/120:, 2-8Mbit/s
M13 003 18 R6 1.6/5.6 (f) to RJ45, 1 Side, 2 RU, 75/120:, 2-8Mbit/s
M13 049 18 R6 BT43 (m) to RJ45, 1 Side, 2 RU, 75/120:, 2-8Mbit/s
M13 044 18 R6 1.0/2.3 (f) to RJ45, 1Side, 2 RU, 75/120:, 2-8Mbit/s
Page 24 www.acande.com
PatchSolutions
DDF Panel Solutions
AC&Es range of matching
DDF Temporary Patching Patch
UnitPanels
complements
PART No LSS PP2the AC&E range
4 x Port of Balun panels 2 x 510 Ohm
thus providing
PART No LSS PP3 interconnect
4 x Port (SI353/970) is 2 x 1K2 Ohm
solution that
highly functional and professional in
appearance. Constructed in zinc sealed, black
powder coated steel they are built for long life.
The Baluns, U Links, Through Adaptors and
Patch Cables listed on this page have been WITH OPTIONAL PATCH LEADS:
designed with compatibility in mind and are 4 Pole to 4 Pole Krone, lead 5m
intended to be used in and on the patch panels length. (S308/..M)
listed here to provide a complete connectivity 2 Pole to 2 Pole Krone, lead 30cm
and interface solution. length. (S332/..M)
Select your coaxial connectors from AC&Es
range of BNC, 1.6/5.6, BT43 and 1.0/2.3 listed
LSS993
on the web for your total requirement.
Description:
Blank Panels
Twisted Pair Frames (Digital Distribution Frame) are common in Telephone & Data Exchanges,
particularly where Krone IDC Block (modules) are used. For DDFs using 2 and 8Mbit/s services
there
OrderisCodes
often an emergency
- Blank need to deploy patching units at strategic positions on the frame.
Panels
Part No. Description
This unit allows theBlank
JS1 Blank insertion
Panel,anywhere on the
1 RU, 19, black frame
powder where
coated steellocalised patching is required.
Having placed
JS4 Blank the unit at the most appropriate position on the
Blank Panel, 2 RU, 19, black powder coated steelframe, looping in and out of the
unit is simple and live traffic can be readily patched through it. Monitor positions are immediately
set-up providing low risk to the main data flow (26dB or 20dB attenuation). A test access is
provided as well. Each of these units has a four circuit configuration installed. A Hitless data
BNC Panels & Accessories
flow situation is then provided.
S267/1M
Order
A rangeCodes - BNCleads
of patch Panels
are available for use with the unit, refer to AC&E for Technical
JS7/40 BNCU BNC panel, 2 x 20, 2 RU, black powder coated steel, empty
information.
JS3/20 BNCU BNC panel, 1 x 20, 1 RU black powder coated steel, empty
The unit features a standard Krone Block 8 position (or 10 position on request). The unit looks
Order Codes - BNC Panel Accessories
like a standard Block but has the necessary attenuators and wiring on the unit, which can be
Balun Select any BNC Standard or Mini from this catalogue
slotted into an emptyUposition
A000409
on the frame without interfering with the other Blocks.
Link BNC (m) - BNC (m) A000409
S267/1M Patch Cable BNC (m) - BNC (m) 1m length
Features:
A000410 BNC (f)-BNC (f) through adaptor (push on), insulated
xAC1291
26dB or 20dB Isolation Resistor
BNC (f)-BNC to avoid
(f) through interruption
adaptor riskinsulated
(bayonet), to data traffic (Hitless).
x Connection between the Test Point and Patch Point.
x Cross-Over at Patch position (allows the same cross patch cords for both normal and patch
positions).
1.6/5.6 Panels & Accessories A001705
x Use of 4 Pole polarised Krone plugs, which can prevent the plugs from causing inversion
connection.
Order Codes 1.6/5.6 Panels
xJS3/48
Minimises
1656U patch1.6/5.6
cord Panel,
congestion
2x24, 1on the
RU, DDF
black (by placing
powder these
coated steel, units15mm
empty, in the appropriate
pitch
position on
JS3P/48 1656U the frame).
1.6/5.6 Panel, 2x24, 1 RU, grey fibre reinforced plastic, empty, 15mm pitch
Circuit
Order Codes - 1.6/5.6 diagram
Panel of one module shown; there are 4 modules in one unit.
Accessories
A001705 Through Adaptor 1.6/5.6 (f) to 1.6/5.6 (f) , uninsulated
Balun Select any 1.6/5.6 Standard or Mini Balun from this catalogue
A001702/15/1/N U Link 1.6/5.6 (m) - 1.6/5.6 (m) screw coupling, 15mm pitch
A001716/15/2/N U Link monitor Snap coupling rear entry monitor (f) 26db 15mm pitch
A001716/15/1/N U Link monitor Screw coupling rear entry monitor (f) 26db 15mm pitch
A001717/15/2/N U Link monitor Snap coupling side entry monitor (f) 26db 15mm pitch
S250/1M/N Patch cable 1.6/5.6 (m) - 1.6/5.6 (m), length 1m
Customized Requirements
Should you have a requirement for a customized Patch Panel, U Link, Balun or Cable please
e-mail us at connect@acande.com with your requirement.
www.acande.com page 25
Customised
Video BalunsBalun Assemblies
A selectionare
Following ofexamples
analogue ofBaluns
customer
are specific
availableproducts
that arethat
designed
we have forproduced on request to solve
specific
use with interface needs.composite
DC to 6.5Mhz You too video
can have your
signals. Suchspecific
signalsneeds
are addressed by AC&E, by
specifying your own requirements. Contact us by phone, fax or web to discuss your requirements.
typically found originating from consumer and professional video
equipment.
Quad Channel Balun Assembly
Coupling signals from remote Video Cameras to recorders, display
Order Code: B04 040 074 Customer: Nokia B00019010
systems and monitors in broadcasting, surveillance and security
Description:are the most common uses.
applications
This
AC&E Quad Channel
Video BalunsBalun assembly
allow has been
long lengths of developed for a to be
coaxial cable
major Worldwide Telecommunication Equipment
replaced with lower cost twisted pair cable. They also allow the use
Manufacturer/Solutions Provider. The product features
of existingconnectors
miniature twisted pair(4x
infrastructure
Type SMB)such and asan telephone cable and
RJ45 socket. B00008010
This package is extremely small
Cat 5 computer networking cables. and is capable of handling
four channels at E1 (2.048Mbit/s) or T1 (1.544Mbit/s) rates
and has an isolation voltage rating of 1.5KV DC.
The AC&E Video Baluns offer the following performance features:-
x Available in Standard and Mini Balun Enclosures
Features:
x No power or batteries
x The size is small for the purpose of converting 4 coaxial
x IEC Standard
transmission paths BNC
into coaxial connection
one single RJ45 socket and
x IDC twisted
packaging pair termination
these functions into awith strainof
volume relief
31 x 33 x
43mm.
x 75/120: transformation
x Various combinations of coaxial connector types can be
x Small size and rugged construction
incorporated into this design such as 1.6/5.6, Type 43,
x 1.0/2.3
BNC, Minimaland
Lossother
distortion and reflection
variations per unit
of connector types can
bex accommodated (sizeand
Other Connectors adjustment
impedancesis necessary
on requestto suit
size of coaxial connectors) upon request.
x Panel solutions also available
x Corporate labeling can be arranged to suit major customer requirements. In addition, for the
purpose of technician labeling an area for felt pen marking is provided.
x Low losses. Insertion Loss: < 0.5dB and Return Loss: better than 20dB.
Electrical Performance
x Frequency Range: DC to 8MHz
Connector, Integral Balun
x Drive distance: 100mPair
recommended max. Twisted pair
Orderx Code: B04 023
Insertion 024
Loss Customer:
(Typ): Telephone Telstra
cable Australia
0.5dB (1m); 3dB (100m)
Features:
x Allows unbalanced coaxial type 75: equipment to simply connect to 120: shielded twisted
pair. It provides interfacing to two separate circuits (a go and come path).
x Avoid more costly and space consuming 75: hardware for patching at the distribution frame.
x Minimal losses and distortion - refer Black Balun characteristics. (refer page 10).
x Low cost and optimal size form a simple design with minimal component count, being integral
with existing connectors typically used in ISDN Interface Cards on AXE Systems.
x Electrically shielded between adjacent circuit.
Insertion Loss B00 019 010 Return Loss B00 019 010
Page 26 www.acande.com
DB9technology
As modern to Coaxial Connector
becomes more integral with our lives, many
www.acande.com page 27
notes Balun Cable Assemblies
Description:
A range of Balun Cable Assemblies are available with your selection of connector types at either
ends. Nominal Impedance ratios of 75 to 120: and bit rates are selectable from the Mini-baluns
shown on page 13 of this handbook. On the balanced side a selection of single or multi-
connectors are available with various forms of mounting and/or shielding. The cable selection is
arranged in Characteristic Impedances and/or shielding cost benefits.
Optional cable labels and cable stress relief attachments are available
Examples:
Pt No S281/3M using B04 001 065 to Pt No S440/1M using 2 x B04 003 065 to
Krone 4P on CBTP26301 RJ45 on STP Cat 5
S281/3M S440/1M
Page 28 www.acande.com
notes
www.acande.com page 29
notes Balun Cable Assemblies
Description:
A range of Balun Cable Assemblies are available with your selection of connector types at either
ends. Nominal Impedance ratios of 75 to 120: and bit rates are selectable from the Mini-baluns
shown on page 13 of this handbook. On the balanced side a selection of single or multi-
connectors are available with various forms of mounting and/or shielding. The cable selection is
arranged in Characteristic Impedances and/or shielding cost benefits.
Optional cable labels and cable stress relief attachments are available
Examples:
Pt No S281/3M using B04 001 065 to Pt No S440/1M using 2 x B04 003 065 to
Krone 4P on CBTP26301 RJ45 on STP Cat 5
Page 30 www.acande.com
Glossary of Terms
glossary of terms
IDC Insulation Displacement Connection.
ITU-G.703 International Telecommunication Union standard for Data Transmission between stations
1RU 1 Rack Unit height. 44mm height for Panels to fit into a rack cavity of 45mm
ISO 9001:2000 Quality Management System requirements for manufacturing, warehousing and design
DDF Digital Distribution Frame
RFI/EMC Radio Frequency Interference/Electromagnetic Compatibility
Krone Krone a manufacturer of IDC connectors
PAL Connector recognised connector used in the TV Industry.
Cat.5e and Cat.6 Two types of cable used extensively for computer networking.
RJ45 A type of modular plug and socket used with the above cables
1.6/5.6, 1.0/2.3
Type 43, SMB,
BNC Common Coaxial connector types used in the Telecommunication Industry.
ESD Electro-Static Discharge
ITU: K17 recognised pulse surge test (type test)
ISDN Integrated Systems Digital Network
AXE A type of Ericsson Switching System
ETSI European Rack System-specification
Telco a type of multi-terminal connector
D9, D15,
D25, D37 a type of multi terminal connector
UTMS a form of Mobile Telephone System (Cell phone System)
T1 1.544Mbit/s
T2 6.312Mbit/s T2 = 4 x T1
T3 44.736Mbit/s T3 = 7 x T2
General Conditions
AC&E reserves the right to change product specifications and availability without notice.
www.acande.com page 31