6GK52080BA102AA3
SCALANCEX208

Productdetails Technicaldata

Technicaldata
Producttypedesignation SCALANCEX208
SCALANCEX208,MANAGEDIESWITCH,8X10/100MBIT/SRJ45PORTS,LEDDIAGNOSTICS,ERRORSIGNALCONTACT
WITHSETBUTTON,REDUNDANTPOWERSUPPLY,PROFINETIODEVICE,NETWORKMANAGEMENT,INTEGRATED
REDUNDANCYMANAGER,INCL.ELECTRONICMANUALONCD,CPLUGOPTIONAL

(https://www.automation.siemens.com/bilddb/index.aspx?

objKey=P_IK10_XX_00825)
Transmissionrate
Transferrate 10Mbit/s,100Mbit/s
Interfaces/forcommunication/integrated
Numberofelectricalconnections
fornetworkcomponentsorterminalequipment 8
Numberof100Mbit/sSCports
formultimode 0
Numberof1000Mbit/sLCports
formultimode 0
forsinglemode(LD) 0
Interfaces/others
Numberofelectricalconnections
forsignalingcontact 1
forpowersupply 1
forredundantvoltagesupply 1
Typeofelectricalconnection
forsignalingcontact 2poleterminalblock
forpowersupply 4poleterminalblock
designoftheremovablestorage
CPLUG Yes
SignalInputs/outputs
Operatingvoltage/ofthesignalingcontacts
atDC/Ratedvalue 24V
Operatingcurrent/ofthesignalingcontacts
atDC/maximum 0.1A
Supplyvoltage,currentconsumption,powerloss
Typeofvoltage/ofthesupplyvoltage DC
Supplyvoltage
external 24V
external 18...32V
Productcomponent/fusingatpowersupplyinput Yes
Fuseprotectiontype/atinputforsupplyvoltage 0.6A/60V
Consumedcurrent/maximum 0.185A
Powerloss[W]
atDC/at24V 3.84W
Permittedambientconditions
Ambienttemperature
duringoperation 40...+60C
duringstorage 40...+70C
duringtransport 40...+70C
Relativehumidity
at25C/withoutcondensation/duringoperation/maximum 95%
ProtectionclassIP IP30
Design,dimensionsandweight
Design compact
Width 60mm
Height 125mm
Depth 124mm
Netweight 0.78kg
Mountingtype
35mmDINrailmounting Yes
wallmounting Yes
S7300railmounting Yes
S71500railmounting No
Productproperties,functions,components/general
Cascadinginthecaseofaredundantring/atreconfigurationtimeof<\~0.3\~s 100
Cascadingincasesofstartopology any(dependingonlyonsignalpropagationtime)
Productfunctions/management,configuration
Productfunction
CLI Yes
webbasedmanagement Yes
MIBsupport Yes
SiemensAG20092016 Imprint(http://www.siemens.com/corporate_info)
TRAPsviaemail Dataprotectionregulations(http://www.siemens.com/privacy)
Yes Cookiepolicy(http://www.siemens.com/cookiepolicyen)
ConfigurationwithSTEP7 DataprotectionTermsofuse(http://www.siemens.com/terms_of_use) Yes
DigitalID(http://www.siemens.com/digital_id_en) 0.0.0.0
Portmirroring Yes
multiportmirroring No
withIRT/PROFINETIOswitch No
PROFINETIOdiagnosis Yes
switchmanaged Yes
Protocol/issupported
Telnet Yes
HTTP Yes
HTTPS Yes
TFTP Yes
FTP Yes
BOOTP No
DCP Yes
LLDP Yes
Identification&maintenancefunction
I&M0devicespecificinformation Yes
I&M1higherleveldesignation/locationdesignation Yes
Protocol/issupported
SNMPv1 Yes
SNMPv2 Yes
SNMPv3 Yes
Productfunctions/Diagnosis
Productfunction
Portdiagnostics Yes
StatisticsPacketSize Yes
Statisticspackettype Yes
Errorstatistics Yes
Productfunctions/DHCP
Productfunction
DHCPclient Yes
Productfunctions/Redundancy
Productfunction
Ringredundancy Yes
HighSpeedRedundancyProtocol(HRP) Yes
highspeedredundancyprotocol(HRP)withredundancymanager Yes
highspeedredundancyprotocol(HRP)withstandbyredundancy No
Protocol/issupported/MediaRedundancyProtocol(MRP) Yes
Productfunction
mediaredundancyprotocol(MRP)withredundancymanager Yes
ParallelRedundancyProtocol(PRP)/operationinthePRPnetwork Yes
ParallelRedundancyProtocol(PRP)/RedundantNetworkAccess(RNA) No
Passivelistening Yes
Productfunctions/Security
Protocol/issupported
SSH Yes
Productfunctions/Time
Productfunction
SICLOCKsupport Yes
Protocol/issupported
NTP No
SNTP Yes
Standards,specifications,approvals
Standard
forFM FM3611:Class1,Divison2,GroupA,B,C,D/T4,CL.1,Zone2,GP.IIC,T4
forhazardouszone EN600790:2006,EN6007915:2005,II3GExnAIIT4KEMA07ATEX0145X
forsafety/fromCSAandUL UL609501,CSAC22.2No.609501
forhazardouszone/fromCSAandUL ANSI/ISA12.12.01,CSAC22.2No.213M1987,CL.1/Div.2/GP.A,B,C,DT4,CL.1/Zone2/GP.IIC,T4
foremittedinterference EN6100064(ClassA)
forinterferenceimmunity EN6100062
Certificateofsuitability/CEmarking Yes

Certificateofsuitability EN6100062,EN6100064
Certificateofsuitability/CTick Yes
Certificateofsuitability/RailwayapplicationinaccordancewithEN50155 No
Certificateofsuitability/RailwayapplicationinaccordancewithEN501241 No
Certificateofsuitability/KCapproval Yes

Marineclassificationassociation/AmericanBureauofShippingEuropeLtd.(ABS) Yes
Marineclassificationassociation/BureauVeritas(BV) Yes
Marineclassificationassociation/DetNorskeVeritas(DNV) Yes
Marineclassificationassociation/GermanischeLloyd(GL) Yes
Marineclassificationassociation/LloydsRegisterofShipping(LRS) Yes
Marineclassificationassociation/NipponKaijiKyokai(NK) Yes
Marineclassificationassociation/PolskiRejestrStatkow(PRS) Yes
Marineclassificationassociation/RoyalInstitutionofNavalArchitects(RINA) No
MTBF/at40C 83.71y
FurtherInformation/InternetLinks
InternetLink
towebsite:SelectorSIMATICNETSELECTIONTOOL http://www.siemens.com/snst(http://www.siemens.com/snst)
towebsite:Industrialcommunication http://www.siemens.com/simaticnet(http://www.siemens.com/simaticnet)
towebsite:IndustryMall https://mall.industry.siemens.com(https://mall.industry.siemens.com)
towebsite:InformationandDownloadCenter http://www.siemens.com/industry/infocenter(http://www.siemens.com/industry/infocenter)
towebsite:Imagedatabase http://automation.siemens.com/bilddb(http://automation.siemens.com/bilddb)
towebsite:CAxDownloadManager http://www.siemens.com/cax(http://www.siemens.com/cax)
towebsite:IndustryOnlineSupport https://support.industry.siemens.com(https://support.industry.siemens.com)
Securityinformation
Securityinformation Siemensprovidesproductsandsolutionswithindustrialsecurityfunctionsthatsupportthesecureoperationofplants,
solutions,machines,equipmentand/ornetworks.Theyareimportantcomponentsinaholisticindustrialsecurityconcept.With
thisinmind,Siemensproductsandsolutionsundergocontinuousdevelopment.Siemensrecommendsstronglythatyou
regularlycheckforproductupdates.ForthesecureoperationofSiemensproductsandsolutions,itisnecessarytotake
suitablepreventiveaction(e.g.cellprotectionconcept)andintegrateeachcomponentintoaholistic,stateoftheartindustrial
securityconcept.Thirdpartyproductsthatmaybeinuseshouldalsobeconsidered.Formoreinformationaboutindustrial
security,visithttp://www.siemens.com/industrialsecurity.Tostayinformedaboutproductupdatesastheyoccur,signupfora
productspecificnewsletter.Formoreinformation,visithttp://support.automation.siemens.com.(V3.4)
lastmodified: 15.02.2016

Technicaldatafortheproductisalsoavailableinthefollowinglanguages:
German
French
Italian
Spanish
Chinese
Russian

CommentforTechnicalData

Name

Phonenumber

email

Comment Numberofcharacters:0(max.500)

Sendcopyofcommenttosender Send

You might also like