PILE DESIGN

GIVEN Ratio 0.99


Pile Diameter, dp 1200 mm
Pile Length, Lp 27 m
Working Compresion, Qwc 16700 kN
Working Tension, Qwt 4150 kN
Ultmate Compresion, Quc 22775 kN
Ultimate Tension, Qut 7089 kN
Concrete Strength, fcu 60 MPa
Steel Yield Strength, Fy 460 MPa
Concrete Cover, cc 75 mm
Mod. Elasticity of Conc., Ec 33000 MN/m
Mod. Elasticity of Steel., Es 210070 MN/m
Concrete Areac, Ac 1130973 mm * (dp) /4

CHECK FOR STRESS IN CONCRETE Ratio 0.98


Working Stress, sact 14.77 MPa Qwc/Ac

Allowable Stress, sall 15 MPa 0.25*fcu

CHECK FOR BENDING MOMENT Ratio 0.99


BENDING MOMENT DUE TO ECCENTRICITY (CASE 1)
eccentrictiy, e 75 mm
Working Moment, Me 1252.5 kNm Qwt * e
FOS 1.4
Utlimate Moment, Meu 1753.5 kNm Me * FOS

HORIZONTAL FORCE DUE TO OUR OF PLUMP TOLERANCE


BS8004 7.4.2.5.4
Horizontal, hor 1
Vertical, vert 75
Horizontal force, H1 222.67 kN Qwc*hor/vert
BENDING MOMENT DUE TO MAXIMUM HORIZONTAL FORCE (CASE-2)
Horizontal force, H2 835 kN min [Qwc *0.5]
Total horizontal force, H 1057.67 kN H1 + H2
Coef. Subgrade Modulus, nh 4 MN/m

Inertia of concrete, I 0.1018 m^4 * (dp)/64


Stiffness factor, T 3.84 m [EI/nh]^(1/5)
Zmax 7.02 Lp/T

Reese and Matlock curve from "Pile Design and Construction Practive 4th ed" by M.J. Tomlinson
PIle Length X
m Z = X/T Fm Moment, Mf = Fm * H * T
0 0.000 -0.92 -3741
-1 -0.260 -0.65 -2643
-2 -0.520 -0.4 -1626
-3 -0.780 -0.2 -813
-4 -1.040 -0.04 -163
-5 -1.301 0.1 407
-6 -1.561 0.2 813
-7 -1.821 0.24 976
-8 -2.081 0.26 1057
-9 -2.341 0.25 1017
-10 -2.601 0.21 854
-11 -2.861 0.17 691
-12 -3.121 0.12 488
-13 -3.382 0.08 325
-14 -3.642 0.04 163
-15 -3.902 0.02 81
-16 -4.162 0 0
-17 -4.422 0 0
-18 -4.682 0 0
-19 -4.942 0 0
-20 -5.202 0 0
-20 -5.202 0 0

Working Moment, Mf 3741.00


STEEL REINFORCMENT OF PILE DUE TO COMPRESSION LOAD
Max. Working Moment, M 4993.50 Mf + Me
FOS 1.4
Utlimate Moment, Mu 6990.90 kNm M * FOS
Utlimate Load, Qu 23380 kN Max [Qwc * FOS, Quc)
Stirrup diameter ds 12 mm
Vertical bar diameter, db 32 mm
Diameter of reinf Cage, hs 994 mm dp-2*(cc+ds+db/2)
hs/h 0.83 hs/dp
M/(hFcu) 0.067 M/(hFcu)
N/(hFcu) 0.271 N/(hFcu)
w 0.28
Area of steel req., As req 41305.11 mm w * Ac * Fcu / Fy
Min. As req 4523.89 mm 0.4% Ac

Actual Provided steel, As act 41808.00 mm Ratio 0.99

From BS8110 Part 3


CHECK FOR MAXIMUM AXIAL NORMAL FORCE Ratio 0.55
Allowable Compression, Nu 41567 kN 0.4 * Fcu * Ac + 0.75 * Fy * As act
Act. Ultimate Compression, Quc 22775 kN

STEEL REINFORCEMENT OF PILE DUE TO TENSION LOAD Ratio 0.55


Required Steel Area, As req 16221.96796 mm Qut / (0.95 * Fy)
Actual Provided steel, As act 29748.00 mm

DUE TO RESISTANCE OF CRACK WIDTH (DIRECT TENSILE STRENGTH OF STEEL) Ratio 1.00
From BS8007:1987 section 3 (Table 3.1)
Limit states
Direct Tensile Strenght Steel, Fst 140.00 Crack with 0.2mm
Area of steel req., As req 29642.86 mm w * Ac * Fcu / Fy
Actual Provided steel, As act 29748.00 mm

DUE TO RESISTANCE OF CRACK WIDTH (DIRECT TENSILE STRENGTH OF CONCRETE) Ratio 0.47
Percentage 10
Direct Tensile Strenght Conc, Fct 6 MPa Percentage * Fcu
Modular ratio, m 6.366 Es/Ec
Area of concrete req., Ac req 532046 mm
Actua area of concrete, Ac act 1130973 mm

CHECK FOR SHEAR RESISTANCE


Ultimate Shear Force, Hu 1480.733333 kN H * FOS
Ultimate Shear Stress, vu 1.64 MPa Hu*1000/(0.8* Ac)
Area of steel 41808.00 mm
(100As/Ac)^(1/3) 1.546 should not be tank greater than 3
(Fcu/25)^(1/3) 1.170 fcu should not be taken as greater than 40 MPa
(400/d)^(1/4) 1 should not be taken as less than 1
Vc 1.143
Vc + 0.4 1.543
0.5Vc 0.571
sv 100.00 mm

Asv 109.84 mm

Asv 135.55 mm