SCON INFRASTRUCTURE

PT DESIGN VERIFICATION SHEET

PROJECT NAME: DMRC-south block-tendon no 10

Note: Input data should be provide cell


mark with following colour only

DESIGN SECTION ID: Location Mid Span

SECTIONAL GEOMETRY DETAILS


B 800 mm wed width
D 600 mm web depth
L 8 m
fck 40 N/mm2 Grade of concrete
fy 500 N Grade of Non prestress steel
fp 1860 N Ultimate stress of tendon
fpe 1200 N Net stress of tendon
I 14400000000 mm4 Moment of inertia of section
A 480000 mm2 C/S area of section
Yt 300 mm C.G. distance from top fiber
Yb 300 mm C.G. distance from bottom fiber
drc 575 mm rc steel CG from top fiber
dpt 575 mm Tendon CG from top fiber

TENDON PROFILE GEOMETRY


a 140 mm #DIV/0!
b 0 mm
c 4000.0 mm
d 4000.00 mm
Wb 8.3 kN-m
Mp(total) 66.33 kN/m

PRESTRESS TENDON DETAILS


p 12.7 mm Tendon dia
Np 4 nos total no of tendon provided
Ap1 98.7 mm2 Area of single tendon
Ap' 394.8 mm2 Area of tendon
P 473.76 kN Tendon net force

NON PRESTRESS STEEL DETAILS


25 mm Non prestress steel dia
Nst 0 nos total no of non prestrss bar provided
Ast1 490.625 mm2 Area of single non prestress bar
Ast.eq 0.00 mm2 Equivalent area of non prestress steel

ANALYSIS DETAILS
Mg(mid) 3600 kN-m Unfactord moment due to SW+DL+LL
Mp(mid) 2028 kN-m prestress moment
Mhyp(mid) kN-m

STRESS CALCULATION
1) Direct Stress RESULTANT STRESS
P/A 0.99 N/mm2
Top fiber -33.74 N/mm2
2) Stress due to prestress eccentricity
Top fiber Bottom fiber 31.76 N/mm2
P.e.Yt/I 42.25 N/mm2
Sign Convention
Bottom fiber "-ve: compression"
P.e.Yb/I 42.25 N/mm2 "+ve: Tension"

3) stress due to gravity Loading


Top fiber
Mg.Yt/I 75.00 N/mm2

Bottom fiber
Mg.Yb/I 75.00 N/mm2
SCON INFRASTRUCTURE

PT DESIGN VERIFICATION SHEET

PROJECT NAME: DMRC-south block-tendon no 10

Note: Input data should be provide cell


mark with following colour only

DESIGN SECTION ID: Location Mid Span

SECTIONAL GEOMETRY DETAILS


B 2000 mm wed width
D 700 mm web depth
L 12 m
fck 45 N/mm2 Grade of concrete
fy 500 N Grade of Non prestress steel
fp 1860 N Ultimate stress of tendon
fpe 1200 N Net stress of tendon
I 166000000000 mm4 Moment of inertia of section
A 3500000 mm2 C/S area of section
Yt 350 mm C.G. distance from top fiber
Yb 350 mm C.G. distance from bottom fiber
drc 650 mm rc steel CG from top fiber
dpt 600 mm Tendon CG from top fiber

TENDON PROFILE GEOMETRY


h 250 mm 1.581139
h1 100 mm
L 1550.0 mm
L1 13690.00 mm
Wc(cantilever) 4929.9 kN-m
Mp(cantilever) 5922.00 kN/m
W(backspan) 101.1 kN-m
M(backspan) 2368.80 kN/m

PRESTRESS TENDON DETAILS


p 12.7 mm Tendon dia
Np 200 nos total no of tendon provided
Ap1 98.7 mm2 Area of single tendon
Ap' 19740 mm2 Area of tendon
P 23688 kN Tendon net force
NON PRESTRESS STEEL DETAILS
25 mm Non prestress steel dia
Nst 0 nos total no of non prestrss bar provided
Ast1 490.625 mm2 Area of single non prestress bar
Ast.eq 0.00 mm2 Equivalent area of non prestress steel

ANALYSIS DETAILS
Mg(mid) 12529 kN-m Unfactord moment due to SW+DL+LL
Mp(mid) 5922 kN-m prestress moment
Mhyp(mid) kN-m

STRESS CALCULATION
1) Direct Stress RESULTANT STRESS
P/A 6.77 N/mm2
Top fiber 7.16 N/mm2
2) Stress due to prestress eccentricity
Top fiber Bottom fib -20.70 N/mm2
P.e.Yt/I 12.49 N/mm2
Sign Convention
Bottom fiber "-ve: compression"
P.e.Yb/I 12.49 N/mm2 "+ve: Tension"

3) stress due to gravity Loading


Top fiber
Mg.Yt/I 26.42 N/mm2

Bottom fiber
Mg.Yb/I 26.42 N/mm2