A

Seminar Report on
2*100 KW MEDIUM WAVES TRANSMITTER
At All India Radio Ajmer
Submitted
In partial fulfillment
For the award of the Degree of
Bachelor of Technology
In Department of Electronics and Communication Engineering

Submitted To: Submitted By:

Sanjeev Yadav Manish Kumar Sharma

Assistant Professor 10EEAEC041

Engineering College Ajmer

Department of Electronics and Communication Engineering

GOVT ENGINEERING COLLEGE AJMER September

2013
ACKNOWLEDGEMENT

It was not possible to prepare this training report without the assistance and guidance of other
people.

On the very outset of this report, I would like to extend my sincere and heartfelt obligation towards
all the personages who have helped me in this endeavor.

I am ineffably indebted to our principal, training and placement officer and teachers who infused
me with the spirit to work upon challenging field which has its inception in such a time when
there is a dire need for new orientation.

I am thankful to the management of All India Radio, Ajmer for allowing us to take training in their
concern.

I am greatly indebted to our supervision and guide Mr. K C Bhati who conceived detailed and
superior guidance throughout our training. Without their ungrudging cooperation it would not
have been possible to complete this training.

Last but not the least; our efforts could never meet this success without the blessing of God and
our families. We can never think of repaying their affection, care and encouragement without
which it would have been difficult to reach the shores.

Manish Kumar Sharma


10EEAEC041
VII SEM
ABSTRACT

Prasar Bharti is a statutory autonomous body established under the Prasar Bharti Act and came
into existence on 23.11.1997. It is the Public Service Broadcaster of the country.

All India Radio (AIR), is the radio broadcaster of India and a division of Prasar Bharti
(Broadcasting Cooperation of India), it is the sister service of Prasar Bhartis Doordarshan.

Report includes the description of all the departments of All India Radio, Lucknow.

First block includes the power supply arrangements of Akashvani. AIR L u c k n o w derives
power supply of 11kVA from two sources (one at a time):-

1. Madar Feeder

2. Gagvana Feeder

However a Diesel Generator is also present as an alternative. It includes the thyristor rectifiers
generally used for AC to DC conversion.

Next section was the cooling section. It included the transmitter cooling and Air conditioning
system. Water being used in transmitter cooling is deionized and purified in water purifier
plants.

AIR Ajmer has two 100kW transmitters connected in parallel. Combined output is of 200kW.
Each transmitter section includes the RF and AF chains and the circuits for removing
harmonics. Audio signal is obtained from Jaipur studio through C-Band. S-Band is used for
reception of short wave signals transmitted from Delhi and other capital stations.

The most important one was the mast/antenna along with the antenna tuning unit. ATU is
used for impedance matching purpose. Antenna used here is of BEL HMB 120. Its physical
height is of 200 m while electrical height is 248m. It is a self-radiating antenna.

We dealt with the basics of Satellite Communication and antennas.

ii
TABLE OF CONTENTS

CHAPTER CONTENTS PAGE


No. No.
Cover page
Certificate
Acknowledgement i
Abstract ii
Table of Contents iii-vi
List of Figures vii-viii
List of Tables ix

1. ALL INDIA RADIO: AN INTRODUCTION 1-5


1.1 Introduction 1
1.2 Prasar Bharti 2
1.3 Infrastructure 2
1.4 High Power Transmitters 3
1.5 ATU, Mast and Aerial Field 3
1.6 Land 3
1.7 Power Supply 3
1.8 Three tier broadcasting 4
1.9 Broadcast Coverage 5

2. POWER SUPPLY 6-9


2.1 Potential Transformer(PT) 6
2.2 Current Transformer(CT) 6

iii
2.3 Circuit Breaker 7
2.3.1 Air Circuit Breaker 7

iv
2.3.2 Oil circuit breaker 8
2.4 Line Isolator 9
2.5 Power Supply Arrangement Description 9

3. MODULATION 11-14
3.1 Modulation 11
3.2 Need for Modulation 11
3.3 Types of Modulation 11
3.3.1 Amplitude Modulation 11
3.3.2 Angle Modulation 12
3.3.3 Phase Modulation 14

4. SATELLITE COMMUNICATION 15-19


4.1 Satellites 15
4.2 Radio Networking Terminal 16
4.2.1 Outdoor unit 16
4.2.2 Indoor unit 19
5. MEDIUM WAVE TRANSMITTER 20-24
5.1 Introduction 20
5.2 Radio frequency chain 20
5.2.1 Crystal Oscillator 20
5.2.2 Transistor Power Amplifier 20
5.2.3 RF Driver 21
5.2.4 Various Pin Voltages 21
5.2.5 RF Power Amplifier 21
5.2.6 PA output circuit 22
5.3 AF Stage 22
5.3.1 High Pass Filter 23
5.3.2 AF Pre-amplifier 23
5.3.3 AF Pre-Corrector 23

v
5.3.4 AF Driver 23
5.3.5 AF Final Stage 23
5.4 Transmitter Salient Features 24

6. PARALLEL OPERATION OF TRANSMITTERS 25-27


6.1 Need for Parallel Operation 25
6.2 Requirements 25
6.3 Procedure for Tuning and Combining 27

7. TRANSMISSION LINES 28-31


7.1 Introduction 28
7.2 Basic Transmission Lines 28
7.3 Types of Feeder Lines 29
7.3.1 Open Wire Feeder Lines 29
7.4 Choice of Feeder Line Impedance 30
7.4.1 Measurement Of Characteristic Impedance, Zo 30
7.5 Power Transmission Capacity of Feeder Line 31

8. COOLING TECHNIQUES IN TRANSMITTER 32-36


8.1 Introduction 32
8.2 Cathodes 32
8.3 Screen Voltage 32
8.4 Cooling System Used in Transmitter 32
8.4.1 Air Cooling 33
8.4.2 Vapour cooling 33
8.4.2 Condensed Vapor Cooling in HMB-140BEL 100 34
kW MW XTR

9. ANTENNA TUNING UNIT 37-41


9.1 Introduction 37

vi
9.2 L Networks 37
9.3 Pi Networks 38
9.4 T Network 40

10. PRINCIPLES OF ANTENNA SYSTEM 42-50


10.1 Introduction 42
10.2 The Function of an Antenna 42
10.2.1 How an Aerial Works 43
10.3 Basic Aerials 44
10.3.1 Hertz Aerial 44
10.3.2 Marconi Aerial 45
10.4 Antenna Radiation Resistance 46
10.5 Radiation Efficiency 47
10.5.1 Field Regions 47
10.5.2 Isotropic Antenna 47
10.6 Radiation Pattern (Polar Diagram) 47
10.7 Half Power (3 dB) Beam Width 48
10.8 Polarizations 48
10.9 Aperture of an Antenna 'A' 49
10.10 Snapshot 50

11. EARTHING SYSTEM 51-56


11.1 Earthing 51

11.2 Methods of Earthing 51


11.3 Measurement of Earth Resistance 51

REFERENCES
57

vii
viii
LIST OF FIGURE

FIGURE No. TITLE PAGE No.

1.1 AIR Logo 1


1.2 Prasar Bharti 2
1.3 Three Tier System 4
2.1. Current and Potential Transformer 6
2.2 Air circuit Breaker 8
2.3 Oil Circuit Breaker 8
2.4 OCB & ACB 9
2.5 Transformer Setup 10
3.1 Amplitude Modulation 11
3.2 Frequency Modulation 12
3.3 Envelope detector 14
4.1 Satellite Communication 16
4.2 Block Diagram of S-Band RN Receive Terminal (RNT) 18
4.3 Snapshot of PDA 19
5.1 Block Diagram of RF Chain (HMB-140) 20
5.2 PA Output Circuit (HMB-140) 22
5.3 AF Stage (HMB-140) 22
6.1 Bridged T Networks 26
6.2 Series to Parallel conversion 26
7.1 Zo of a Feeder Line 29
7.2 Open wire transmission line 29
7.3 Transmission Lines On a Tower 31
8.1 Vapour Cooling System 34
8.2 Water Flow Circuit 100 kW MW XTR 35
8.3 Cooling Pipes 37
9.1 Phase lag (Rin> RL) 38
9.2 Phase lag (RL>Rin) 38
9.3 Phase lead (Rin> RL) 38
9.4 Phase lead (RL>Rin) 38
ix
9.5 Pi Network 39
9.6 T Network 41
10.1 The Aerial Converts Electrical Power Into Electro-magnetic 42
Waves
10.2 Half Wave Dipole Aerial 43
10.3 Electric Field Surrounding an Aerial 43
10.4 Magnetic Field Surrounding an Aerial 44
10.5 Basic Aerials 45
10.6 MW Antenna Isolated from ground 46
10.7 Antenna Radiation Pattern Top View and Side View 48
10.8 Antenna and Guy Wire Insulator 50
11.1 Typical Arrangement of Pipe Earthing 53
11.2 Typical Arrangement of Plate Earthing 54
11.3 Testing of Earth Electrode Resistance 55
11.4 Earth Tester 56

x
LIST OF TABLES

TABLE No. TITLE PAGE No.

5.1 Transmitter Salient Features 24

xi
xii
Chapter.1
ALL INDIA RADIO: AN INTRODUCTION

1.1 INTRODUCTION
All India Radio (AIR) ,one of the largest radio networks in the world is a division of Prasar
Bharti (Broadcasting Cooperation of India) currently working under the Chairmanship of
Smt. MRINAL PANDEY and Shri JAWAHAR SIRCAR as its Chief Executive Officer
Established in 1936, today it is the sister service of Prasar Bhartis Doordarshan, the national television
broadcaster.

All India Radio is also known as Akashvani. The head quarter is at the Akashvani Bhavan, New Delhi.

AIR today has a network of 237 broadcasting centers with 149 medium frequency (MW), 54 high
frequency (SW) and 177 FM transmitters. The coverage is 91.85% of the area, serving 99.18% of
the people in the largest democracy of the world. AIR covers 24 Languages and 146 dialects in
home services. In External services, it covers 27 languages; 17 national and 10 foreign languages

Fig.1.1 AIR Logo

1
1.2 PRASAR BHARTI

Prasar Bharti has mainly two mainly two branches-

PRASAR BHARTI

ALL INDIA DOORDARSHAN


RADIO

Fig.1.2 Prasar Bharti

1.3 INFRASTRUCTURE

All India Radio came to be known as Akashvani from 1957. From a meager 18 Transmitters in
1947 AIR acquired 46 by the end of 1st plan, 59 by 2nd plan, and 110 by the end of 8th plan. Total
number of transmitters has gone up to 337, consisting of 144 MW, 54 SW and 139 FM
transmitters.

The number of radio stations went up to from 6 in 1947 to 215 by Dec-2004.AIR took over radio
station being run by native states since British days such as Akashvani Mysore, Hyderabad radio,
Radio Kashmir etc.

2
1.4 HIGH POWER TRANSMITTERS

These stations are equipped with short wave/ medium wave transmitters together with extensive
aerial system to serve the external, home and news services of All India Radio. The main function
of these centers is to transmit the programs produced at nearby studios and also from Delhi studios.

1.5 ATU MAST AND AERIAL

There is a 200 m height ECIL makes Self Radiating Guyed Mast. There are six numbers of Guys
on different height segments of this mast. The feeder lines, ATU, mast and aerial field are being
maintained in proper condition. There is a permanent security wall with fencing around the
Transmitters Complex site .However, the Ariel field is separately fenced with security wall.

1.6 LAND

The Transmitters Land comprising of 140 bigha (approx. 23, 86,560sq.ft) is on lease from Government
for an amount of Rs.140/-annum. The land is on Jaipur-Ajmer national highway.

1.7 POWER SUPPLY

There are 2 numbers of 11KV Overhead HT Feeders from Rajasthan state Electricity Board,
namely Madar feeder and Gagwana feeder. These 11 KV overhead feeders comes to the
G.O.SWITCH,LOCATED NEAR THE MAIN GATE OF Transmitting complex the HT metering
panel is also located near this, and these are maintained by RSEB.From G.O.Switch the HT Power
Supply comes to the 2 independent 11 KV OCBs through underground cables. From these OCBs
the HT power supply is connected to the 2 nos.750KVA capacity HT transformers through
independent isolators. Here it may be mentioned that at one time anyone OCB with the
corresponding isolator can be connected to the 1HT transformer.

3
1.8 THREE-TIER BROADCASTING SYSTEM

AIR has a three-tier system of broadcasting. These three levels of programmes are the National,
Regional and Local each having distinct audiences.

Three-tier
Broadcasting System

National Regional Local

Fig.1.3 Three Tier System

National programmes are broadcast from Delhi for relay by the Capital, Regional and Local Radio
Stations. Some of these are the National Programme of Talks and Features in Hindi and English,
the National Programmes of Drama and Music.

The National Channel of All India Radio located in Delhi broadcasts programmes which are
heard on Medium Wave and also on Short Wave. Started on 18th May 1988, this channel
works as a night service from 6.50 PM to 6.10 AM the next morning. Broadcasting in Hindi,
Urdu and English, the programme composition of the channel has been designed to make it
representative of the cultural mosaic and ethos of the country.

The Regional Stations in different States form the middle tier of broadcasting. They originate
programmes in the regional languages and dialects. Regional Channels are located in the major
linguistic-cultural region of every state. 116 Regional Channels are spread over 29 states & 6
Union Territories including the North-Eastern Service at Shillong that projects the vibrant
cultural heritage of the North-Eastern region of this country. The Regional Channels, broadcast
largely on the Medium Wave frequency, follow a composite programme pattern comprising
of music - classical, light, folk and film, News and Current Affairs, Radio plays, features,
Farm and Home programmes, programmes on Health & Family Welfare and programmes
for Woman, Children etc.

4
Local Radio is relatively a newer concept of broadcasting in India. Local radio stations serve
small communities, showcase local culture and broadcast area specific programmes for the
benefit of the community. The transmission is in the FM mode. The programming is flexible
and spontaneous and the stations function as the mouth piece of the local community. At
present there are 86 Local Stations spread across the country.

1.9 BROADCAST COVERAGE

a) By area 91.42%
b) By Population 99.13%

Chapter.2

POWER SUPPLY

5
There are two 11KV Overhead HT Feeders from Rajasthan state Electricity Board, namely
Madar feeder and Gagwana feeder. Various terms related to the Power Supply
Arrangement are:

2.1 POTENTIAL TRANSFORMER (PT)

The PT has large numbers of turns in primary and a small number of turns in secondary. It is
connected across the line. Potential transformer is also used to step down from rated
voltage/1.732 to 110volts/1.732. It is connected between phase and neutral.

2.2 CURRENT TRANSFORMER (CT)


Current transformer is used for measuring and protection purpose. It is used to step down
from rated current (40 A) to 5A. It is connected in series across conductors. The CT has a
single turn primary and some few numbers of secondary turns, and it is ALWAYS kept
short circuited. Using two CTs and PTs measurement of power in a three phase system

l'
can be obtained correctly.
a HV CT a._v

JII[ _1E
bL
b' H' v
E
v


...L
II[ ...L
CL
CHV

1 JII fe V

Fig.2.1 Current and Potential Transformer

2.3 CIRCUIT BREAKER:

The devices used for making and breaking an electrical circuit under some predetermined
condition are called circuit breakers. The functions of a circuit breaker are as follows:

6
1. It must close on and carry full load currents for long period.
2. It must open automatically to disconnect the load, on over load under predetermined
condition.

3. It must rapidly interrupt the heavy current, which may flow under a short circuit
condition in any part of the system.

4. The circuit breaker must be capable of withstanding the effect of arcing at its contact
and the thermal conditions, which arise due to flow of current.

All circuit breakers consist essentially of pairs of matting contacts, each pair comprising
fixed and moving elements. Under normal conditions, these elements are in contact and
carrying full load current; but on receipt of a tripping signal initiated by hand or protective
gear, the circuit will be interrupted. At the start of the separation, an arc will be established
which is required to be extinguished as early as possible.

Generally, we come across two types of circuit breakers at medium and high voltage, for
indoor application. They are called Oil Circuit Breaker (OCB) and Air Circuit Breaker
(ACB).

2.3.1 Air circuit breakers


An air circuit breaker is that kind of circuit breaker which operates in air at atmospheric
pressure. In air circuit breakers, the arc exists in the mixture of nitrogen, oxygen and
metallic vapor and the successful arc interruption takes place due to cooling by diffusion.

Rated current up to 10,000 A. Trip characteristics are often fully adjustable including
configurable trip thresholds and delays. Often used for main power distribution in large
industrial plant.

7
An Splittl'rs

Arc
Moving
Contact
Fixed Contact
Opening

i
Air flow

Fig.2.2 Air circuit Breaker

2.3.2 Oil circuit breaker


In oil circuit breaker the fixed contact and moving contact are immerged inside the
insulating oil. Whenever there is a separation of current carrying contacts in the oil, the
arc is initialized at the moment of separation of contacts, and due to this arc the oil is
vaporized and decomposed in mostly hydrogen gas and ultimately creates a hydrogen
bubble around the arc. This highly compressed gas bubble around the arc prevents
restriking of the arc after current reaches zero crossing of the cycle.

ic....dGt

1--+---/lrC

Fig.2.3 Oil Circuit Breaker

'

Fig.2.4 OCB & ACB

2.4 LINE ISOLATOR:

The line isolator is used to isolate any RF (common mode) that may have worked its way back to
the station i.e. Keep that RF off of the outside of the transmission line and delivered to the antenna
where it belongs.

2.5 POWER SUPPLY ARRANGEMENT DESCRIPTION:

1. From the two incoming feeder lines, one of them is selected using the G.O.Switch.
2. The incoming high voltage (11 KV) is stepped down to 110 V using a Potential Transformer
(PT).

3. The Current Transformer further reduces the current from 40 A to 5 A.


4. Further the two incoming feeder lines are interlocked mechanically using Kassel key.
Oil Circuit Breakers are used in it.

9
Fig.2.5 Transformer Setup

Chapter.3

MODULATION

10
3.1 Modulation
Modulation is a process of superimposing information on a carrier by varying one of its parameters
(amplitude, frequency or phase).

3.2 Need for Modulation


Modulating the signal over higher frequency can reduce antenna size.
To differentiate among transmissions (stations)
Maximum to minimum frequency ratio can be reduced to minimum by modulating the signal
on a high frequency.


3.3 Types of Modulation
In general, there are three types of modulation:
a) Amplitude Modulation b) Angle Modulation
c) Pulse Modulation

3.3.1 Amplitude Modulation


If the amplitude of the carrier is varied in accordance with the amplitude of the modulating signal
(information), it is called amplitude modulation. This modulation has been shown in fig

3.1. We can see this on the screen of oscilloscope.

AAAAAAAAAAAAAAAAA
rv v v v v v v v v v vv vv v \
Carrier freq. fc
Amplitude Ac
Vc(t)

Vm(t
/\
~
/\ Modulating Signal freq. fm
amplitude Am

Amplitude Modulated
DSB Signal

Carrier amplitude corresponding to negative peak of signal is


zero for 100% modulation (Am=Ac)
Fig. 3.1 Amplitude Modulation

Bandwidth
BW 0 (f c 0 fm) 0 (fc 0 fm) 0 2fm

11
Angle Modulation

Variation of the angle of carrier signal with time results in angle modulation. It is of two types

a) Frequency Modulation
b) Phase Modulation

3.3.2 Frequency Modulation

If the frequency of the carrier is varied in accordance with the amplitude of the modulating signal
(information), it is called frequency modulation. This has been shown in figure 3.2.

Maximum frequency corresponding to positve peak amplitude of modulation signal

Minimum frequency corresponding to negative peak amplitude of mod. signal

Carrier freq. f c
V c(t)
Amplitude A c

V m (t Modulating Signal freq. f m


) amplitude A m

Freq. Modulated
V(t) signal

Fig . 3.2 Frequency Modulation

Power
1
This holds true for any type of a modulating signal and for any value of modulation index.

12
pc A2 2 c Power of the unmodulated carrier

Where, Ac = Amplitude of the carrier


Am = Amplitude of the modulating signal
f f
Band width of FM signal
mf Modulation Index fm fm Band width can be defined as that
Frequency deviation frequency range which
f
Frequency of the modulating signal
fm accommodates the carrier and the

closest side bands contributing at least 98% of the total signal power. (Carson rule).

BW = 2 (mf + 1) fm = 2 (mffm + fm) = 2 ( f + fm)

Detection of AM Signal

There are many types of detectors for detecting various form of AM signals. One such detector
is Envelope Detector, which is used for detection of DSB - FC signal. The operation of this
detector is discussed below:

Envelope Detector

The circuit diagram of envelope detector along with wave form is shown in Fig. 14 (a) and (b).
During positive half cycle of the input, capacitor C charges to almost the peak value of the half
cycle. When the level of input voltage starts falling, the diode D is reversed biased by the voltage
on the capacitor. The capacitor discharges through the resistance R with a time constant RC. The
discharging of the capacitor continues, till, in the next positive part of the carrier cycle, the input
voltage exceeds the capacitor voltage. Then, the diode conducts again and the whole process
repeats. Thus, in each carrier cycle, the capacitor charges to nearly the peak value of the cycle.

The practical circuit will be somewhat different from the circuit of fig. 3.3.

13
D
Diode
Current
AM Input
C R

Output
t

(a) Output
Voltage

Fig. 3.3 t Envelope Detector


(b)

3.3.3 Phase Modulation

If the Phase of the carrier is varied in accordance with the amplitude of the modulating signal
(information), it is called phase modulation.

Chapter .4

SATELLITE COMMUNICATION

There are various sources of programs in Akashvani Ajmer.


1. S-Band
2. C-Band
3. DTH

14
Programs are recorded in Jaipur studio. These recorded programs were previously transmitted
through Telephone lines. But these days S-Band and C-Band are generally used for transmission.

4.1 Satellites:

Satellites are basically reflectors in sky. Satellite Communication is the outcome of the desire of
man to achieve the concept of global village. Penetration of frequencies beyond 30 Mega Hertz
through ionosphere force people to think that if an object (Reflector) could be placed in the space
above ionosphere then it could be possible to use complete spectrum for communication purpose.
1st satellite named as Sputnik -1 was launched in 1957 by USSR from Bikonour Cosmodromme
in Kazakhstan. It was a low orbit passive satellite. It could only reflect the signals mechanically
and could not receive, amplify, or change the frequency before transmission. In 1962 Telstar was
launched from Cape Carnival by USA. It was also a low orbit satellite but active satellite.

Due to following advantages satellite communication is generally used:


- This is only means which can provide multi access two way communication. Within the
coverage area, it is possible to establish one way or two way communication between any
two points.

- Satellites are capable of handling very high bandwidth. Normally any satellite can
accommodate about 500 MHz in C Band. For example the bandwidth of INSAT-I is 480
MHz in C Band and 80 MHz in S Band. INSAT-II has a bandwidth of 720 MHz in C
Band and 80 MHz in S Band.

- It is possible to provide large coverage using satellite. For example geostationary satellite
can cover about 42% of earth surface using global beam.
- It is easy and quicker to establish new satellite link using SNG terminal or VSAT terminal
from any point to any other point as compared to any other means.

15
SE3te41ite-

Fig.4.1 Satellite Communication

4.2 Radio Networking Terminal


The various All India Radio stations spread throughout the nation are required to relay certain
programs which are originating from Delhi. Similarly there are certain programs which are
originating from capital stations are relayed by the other stations in that region. In order to link
Delhi and capital stations with other AIR stations, RN through INSAT is not only cost effective
but also provide the good technical quality as compared to DOT lines and SW linkage. Thus RNT
acts as the ground terminal for satellite signal reception. The block diagram of S-band RN
terminal is shown in figure 4.1.

The C-Band RNT has mainly two units: 1. Outdoor unit 2. Indoor unit.

4.2.1 Outdoor unit :


Outdoor unit has mainly two components. a.
PDA b. LNBC

a. Parabolic Dish Antenna :


PDA, 1.6 m Chicken mesh, is used to receive the downlink RF. The antenna assembly
collects and concentrates RF transmitted signals that are produced by communication
satellite (INSAT 3C, 74E) and converts them to an electronic signal. PDA is installed such
that it receives maximum signal. Its azimuthal (Az) and elevation angles (EL) are given by
following formulas as viewed to INSAT 3C.

16
EL = tan-1( cosD.cos - r/R )
( 1 (cosD.cos )2)1/2
AZ = 180 tan-1(tanD/sin)
Where, D = r s in degrees r = longitude
of the given s = longitude of the satellite
r = Radius of earth = 6367 kms

R = Radius of synchronous orbit = 42,165 kms

= latitude of given site

Coordinates of HPT Ajmer

Latitude () = 263107

Longitude (r) = 744300

Longitude (s) = 74 E

EL = 59 AZ = 181.61

17
LNA Feed

DA
---- Front End Convertor ---
Mixer 50Db

RF
:!: [> BPF
92MHz POCO DI 1----- ,

PCO DI POCO DI
Switch
Mixer 50Db BPF
POCO DI

:!: [> 52MHz

- Frequency Translator (Active) -

_, Synthesiser r ------1 IF Amplifier


Audio Demodulator
& Mixer &
5.5 MHz
Divider
- -1Synthesiser
Audio Demodulator
& Mixer
5.5 MHz IF Amplifier
I
rl4------1 Synthesiser-- &
Audio Demodulato
5.5 MHz & Mixer Divider
Audio
I
Audio Demodulato
5.5 MHz
9 dBm
I
rl4------1 Synthesiser i-_,----1
Audio Demodulator_. I& Mixer I- I IF Amplifier
(EDD ohms) 5.5 MHz --..... (Mixer & LO)
BPF
. --1 Synthesiser
Audio Demodulator
s
~ Mixer IF Amplifier
5.5 MHz

_,11 Synthesiser---- ~ (Mixer & LO)--

BPF
11 & Mixer ~

< Audio Demodulator> <Synthesised Translator> <Frequency Translator (Active) >

Fig. 4.2 Block Diagram of S-Band RN Receive Terminal (RNT)

The RF signals gathered by the antenna (PDA) are forwarded on the feed horn, which collects the
signals. The output of feed horn is then directed to the LNB down converter, which provides the
initial amplification of the C-Band downlink signals and converts the C-Band signals to LBand.
The output of LNB, down converter is routed to the IFL ( Interfaciality Link ) cable (RG 11)
18
Fig 4.3 Snapshot of PDA

4.2.2 Indoor unit :


Indoor unit has mainly satellite digital audio receivers. The ABR202 receive L-Band RF
and process it. After processing this satellite receiver provides analog L-R audio channels
and digital audio output also. The receiver is also connected with computer by data port.
This receiver chain is remotely controlled through computer command. It has mainly three
indication in front panel, power, sync, enable. If the power is ok green indication will be
displayed and if EB is greater than 7 sync will be locked and if EB is less than 4, receiver
will not respond to the system.

Chapter .5

MEDIUM WAVE TRANSMITTER

19
5.1 Introduction

A.M. Transmitter of any power in general will have a separate HF and AF stages. In the
conventional transmitters, vacuum tubes are used right from the first stage to the final stage and
the preliminary stages are solid state devices.

100 kW HMB 140 Medium Wave transmitter

5.2 Radio frequency chain

RF circuits consist of a crystal oscillator, transistor power amplifier, RF. Driver and Power Amplifier
of 100 kW HMB 140 MW transmitter are shown in Fig. 5.1

I CRYSTAL
OSCILATOR :
H :
TRANSISTOR
PA
H
:
RF H POWER
DR : . : AMP.

Fig.5.1 Block Diagram of RF Chain (HMB-140)

5.2.1 Crystal Oscillator

To oscillate at a consistent frequency, the crystal is kept in a oven. The temperature of the oven
is maintained between 68 to 72o C and the corresponding indication is available in the meter panel.
Crystal oven is heated by + 12 V. One crystal oscillator with a standby has been provided. It
gives an output of 5 V square wave which is required to drive the Transistor Power Amplifier.
The crystal oscillator works between 3 MHz and 6 MHz for different carrier frequencies.

5.2.2 Transistor Power Amplifier

Oscillator output is fed to the transistor Power amplifier (TRPA). It gives an output of 12 Watt
across 75 ohms. It works on + 20 V DC, derived from a separate rectifier and regulator. For
different operating frequencies, different output filters are selected. (Low Pass Filter).

5.2.3 RF Driver

A 4-1000 A tetrode is used as a driver which operates under class AB condition, without drawing
any grid current. About 7 to 10 Watts, of power is fed to the grid of the driver through75: 800

20
ohms RF Transformer, which provides proper impedance matching to the TRPA output and also
provides the necessary grid voltage swing to the driver tube.

5.2.4 Various Pin Voltages

The cathode of the driver : - 600 V.


Control grid : - 650 V. Screen
grid : - 100 V.

Plate Voltage : +1900 V

Because the cathode is at -600 V, the effective grid to cathode bias voltage (fixed) is -50V and the
effective plate voltage is 2500 V. The driver develops a peak grid voltage of 800 to 900 V at the
grid of PA and PA grid current of about 0.3 A to 0.4 Amps. The required wave form for operating
the PA as class -D operation is also developed at the output of the driver by mixing about 20%
third harmonic with the fundamental which is the operating frequency of the transmitter.

5.2.5 RF Power Amplifier

CQK - 50, condensed vapor cooled tetrode valve is used as a PA stage. High level anode
modulation is used, using a class B Modulator stage. The screen of the PA tube is also modulated
by a separate tap on modulation transformer. Plate load impedance of the PA stage is about 750
ohms and the output impedance is 120 ohms, and it is matched by L-C components.
5.2.6 PA output circuit
---1i--.----.--'
C2411

Fig. 5.2 PA Output Circuit (HMB-140)

The L-C combination of the output circuit provides the following:

21
1. The required load impedance for Class D operation that is there should be third harmonic
impedance in addition to the fundamental impedance.

2. Matches the plate impedance of 750 ohms to the feeder impedance of 120 ohms at the operating
frequency.

3. Filters all the 2nd and 3rd harmonic before the feeder.

5.3 AF Stage
PA
PRE AF
CORRECTOR DRIVER NLF.
IKXl.n. PRE
AF HIGH AMP
PASS
BALANCED FlLTER PRE AF
CORRECTOR DRIVER

HT

Fig. 5.3 AF Stage (HMB-140)

The AF stage supply the audio power required to amplitude modulates the final RF stage. The
output of the AF stage is superimposed upon the DC voltage to the RF PA tube via modulation
transformer. An Auxiliary winding in the modulation transformer, provides the AF voltage
necessary to modulate the screen of the final stage. The modulator stage consists of two CQK25
ceramic tetrode valves working in push pull class B configuration as shown in figure 5.3.

5.3.1 High Pass Filter

The audio input from the speech rack is fed to active High Pass Filter. It cuts off all frequencies
below 60 Hz. Its main function is to suppress the switching transistors from the audio input. This
also has the audio attenuator and audio muting relay which will not allow AF to further stage till
RF is about 70 kW of power.

5.3.2 AF Pre-amplifier

22
The output of the High Pass Filter is fed to the AF Pre-amplifier, one for each balanced audio line.
Signal from the negative feedback network from the secondary of the modulation transformer and
the signals from the compensator also are fed to this unit.

5.3.3 AF Pre-Corrector

Pre- amplifier output are fed to the AF Pre-correctors. As the final modulator valve in the AF is
operating as Class B, its gain will not be uniform for various levels of AF signal. That is the gain
of the modulator will be low for low level input and high for high level AF input because of the
operating characteristics of the Vacuum tubes. Hence to compensate for the non linear gain of the
modulator. The Pre-corrector amplifies the low level signal highly and high level signal with low
gain. Hum compensator is used to have a better signal to noise ratio.

5.3.4 AF Driver

Two AF drivers are used to drive the two modulator valves. The driver provides the necessary DC
Bias voltage and also AF signal sufficient to modulate 100%. The output of AF driver stage is
formed by four transistors in series as it works with a high voltage of about -400 V. The transistors
are protected with diodes and Zener diodes against high voltages that may result due to internal
tube flashovers. There is a potentiometer by which any clipping can be avoided such that the
maximum modulation factor will not exceed.

5.3.5 AF Final Stage

AF final stage is equipped with ceramic tetrodes CQK-25. Filament current of this tube is about
210 Amps. at 10V. The filament transformers are of special leakage reactance type and their short
circuit current is limited to about 2 to 3 times the normal load current. Hence the filament surge
current at the time of switching on will not exceed the maximum limit.
5.4 TRANSMITTER SALIENT FEATURES:-

Table no. 5.1

S. No Property Description
1 Make/ Type BEL HMB 140
I I

23
2 Radiated Power 2x100 KW
3 Frequency 603Khz
4 Wavelength 497.51 meters
5 MAST height 200 meters
6 Electrical Height 248 meters
7 MAST base Impedance 778+j50.30HMS
8 Site Area 2386565 Sq.mt, 140 BIGHA
9 Transmission Hours 05:55 09.30
12:00-15:00
17:00-23:10
10 Coverage AJMER-KOTA-JHALAWAR-UJJAIN
256Kms.

AJMER-CHITTOR-UDAIPUR-
BANSWARA 223Kms
AJMER-SIKAR-CHURU-BIKANER
197Kms
AJMER-JAIPUR-ALWAR-DELHI
215Kms.

AJMER-PALI-JODHPUR-POKRAN
221Kms.

11 Power Suppy Two 11kv overhead feeder from


MADAR and GAGWANA
12 Standby Power Supply 2*400KVA 3ph Alternator Kirloskar

Chapter.6

PARALLEL OPERATION OF TRANSMITTERS

6.1 Need for Parallel Operation


At times it may not be possible to get the required power from the single transmitter for the
required coverage of the broadcast service. In such conditions, it is essential to combine two or
more transmitters to get the required power. Besides combined operations also facilitate operation

24
of single transmitter in case of failure of one transmitter thereby achieving reliability of the
service.

6.2 Requirements
Like parallel operation of alternators/generators there are three conditions to be satisfied for parallel
operation of two transmitters. They are

Frequency of the transmitter should be the same.


The phase of the signal of the transmitters at combiner should be the same.
The power levels of both the transmitters should be such that the amplitude at the combiner is
equal.

In order to meet the first condition, it is possible to use one frequency source for both the
transmitters. Hence if there is any drift in the frequency, it will be common to both the
transmitters.

The phase of the signal of the transmitters depends upon the tuning stages which employ active
amplifiers.

Such a network used for combining shall be such that it should


Should offer equal load impedance to both the transmitters.
Shall be able to continue the operation even if one of the transmitter goes off the air.
Shall facilitate to dissipate the unbalanced power flowing through the combiner network.

The most common network which is used is a bridged T network. The figure 1 shows such a
network. It has four reactive networks. Two capacitive and two inductive and all are having
impedances equal to that of feeder line. These impedances can be interchanged as shown in figure
6.1 (a) & (b). The bridged arm also has got one resistive load equal to feeder impedance.

This shall take care of the unbalances in the network.

25
o------- o
-jRf T Feder
I
-
Transmitter
Rf

(a)BRIDGED ''T'' NETWORKS (b)

Fig. 6.1 Bridged T Networks

The break-up of impedances indicates how this network offers proper impedances to the transmitters
at all possible conditions.

Impedances can be converted into a parallel impedance and vice versa using the following formulae: -

Rp D Rs D 1oD Xs/Rs oD 2

Xp o Xs D 1 oD Rs/ Xs oD 2
, Rs O Rp DD 1 2
,

DD 1 DD Rp/ Xp DD

1
Xs D Xp

1oD Xp/Rp D 2

Rs Rp Xp
Xs

Fig. 6.2 SeSrieersietsotoPaPraarlalellel lconversion


Conversion

With the help of these equations we can break up the impedances as shown in figure 2. There are
two cases of possibilities. They are I) both transmitters are working in combined mode ii) One of

26
the transmitter failed in combined mode. In the previous case we see that both transmitters get
proper load. And in the later condition, the transmitter in working condition gets proper load, but
half the power is lost in combiner reject load.

6.3 Procedure for tuning and combining

Tune each arm of the network for impedance equal to load impedance.

Connect the network and terminate the load impedance.

Measure the load impedance offered at each of the transmitter. It should be equal to load impedance.
If not adjust the reactance.

Open and short-circuit the output point of one of the transmitter (in off condition) and measure the
load impedance at the other transmitter. It should not change.

Now put on the transmitters with a single oscillator source.

If there is unbalance try to adjust with the phase control of oscillator for minimum unbalance.

If the unbalance still persists try to adjust the power levels of the transmitters either by HT or AVR
variations.

Modulate the transmitter slowly to see whether there is unbalance. If so check the audio phase to
each of the transmitter.

27
Chapter.7

TRANSMISSION LINES

7.1 INTRODUCTION
R.F. Energy of a transmitter is guided up to radiator (mast) by the propagation of Trans-verse
Electro-magnetic waves along systems of parallel conductors called Transmission lines or feeder
lines. The input energy is stored in the field of conductors and is propagated along the system at
some finite velocity.

It is essential to keep the antenna at a distance from transmitter due to prevent


Radiation hazard
pick up from antenna and consequent problem with transmitter circuit

The feeder line should carry the power from the transmitter to Antenna with

Minimum loss
Minimum radiation.

7.2 BASIC TRANSMISSION LINES


There are three types of transmission lines used at RF. They are:
(i) Open wire feeder lines
(ii) Co-axial feeder lines
(iii) Wave guides

Characteristics Impedance of Feeder Lines


Characteristics impedance (Zo) is defined as the input impedance of an infinite line. A transmission
line can be represented as having R, L, and C.

28
Fig. 7.1 Zo of a Feeder Line

The inductance, resistance, capacitance and conductance of the line determine the characteristics
impedance.

The characteristic impedance is given by the following basic formula

Zo D R D j D L G
D
jD C
At higher frequencies R&G becomes negligiblewith respect to reactances of L &C. There fore
L
Zo D C

7.3 TYPES OF FEEDER LINES

1. On basis of circuit, they are :


Balanced lines : Where there are equal and opposite potential in both wires.

Unbalanced lines : Here one wire is at high potential and the other side is at low
potential.

2. Structurally there are two basic forms :


(I) Open wire line (ii) Enclosed line.

7.3.1 Open wire feeder lines

Z0 D 276log2S/d

29
Fig.7.2 open wire transmission line

In MW band, normally the feeder lines used are unbalanced and has following characteristics:

6 wires- 230 Ohms


16 Wires- 120 Ohms
24 Wires- 60 Ohms

In SW, normally the balanced feeder lines are used. The impedances are

300 Ohms- 4 wire


600 Ohms- 2 wire

7.4 CHOICE OF FEEDER LINE IMPEDANCE

When the feeder line impedance is chosen low, feeder current will be more, resulting increase in
copper loss and earth loss. When feeder line impedance is high, feeder voltage will be high
resulting in the use of higher voltage rating insulators. So the choice depends upon the availability
of components and technology in use.

120 ohm feeder line is now standardized for modern transmitters.

7.4.1 Measurement Of Characteristic Impedance, Zo

Zo of a feeder line is given by the relation

Zo Zoc.Zsc

Zoc = Open circuit Impedance, measured at input by keeping the feeder line end open.
Zsc = Short circuit Impedance, measured at input by keeping the feeder line end short. Generally
Zoc&Zsc are either capacitive or inductive depending upon the length of feeder line as multiple of
/4. .

30
7.5 POWER TRANSMISSION CAPACITY OF FEEDER LINE
The power handling capacity of a line depends upon :

Numbers of live wires used in parallel.


The charge density per unit surface of the wire.
Maximum allowable potential gradient to avoid flashover, and corona etc.

iffi"f..--1115
-
...---
DfilS

TWl)tca1 TransmfssJon Un
Fig.7.3 Transmission Lines On a Tower

31
Chapter.8

COOLING TECHNIQUES IN TRANSMITTER

8.1 Introduction
In modern A.M. transmitters power valves are used in the power amplifiers (PA)and modulator
stages, which are condensed vapour cooled ceramic tetrodes. In the old generation transmitters,
triodes are used in the PA, modulator and exciter stages. Both the tetrodes and triodes tubes are
capable of being operated at high voltages (11 kV DC) and large anode current of the order of
50 Amps. They also draw large filament current of about 620 Amps at 24 volt CQK-350.
Hence the tubes dissipate large amount of power which require effective cooling. The CQK
series of transmitting tubes are tetrodes, specially designed for transmitters and power
amplifiers used in broadcasting.

Slowly insert the tube in the connection head so that sudden impact is avoided. If the dead weight
of the tube is not sufficiently to overcome contact resistance in the connection head, apply gentle
pressure.

8.2 Cathodes
All the ceramic tetrodes used in AIR transmitters have directly heated thoriated tungsten cathode.
The filament voltage should not vary beyond +5% of the rated filament voltage. The filament
voltage must always be measured at the concentric contact rings using sub-standard volt meter.
The cathode cum filament has only a very small resistance when cold. Hence the filament voltage
is applied and increased smoothly as per the design of the transmitter.

8.3 Screen Voltage


The screen grid current can become dangerously high, even at normal screen grid voltage, when the
anode voltage is lower than that of the screen grid. Hence the screen grid supply will be switched ON
only when the anode voltage has become about 40%.

8.4 Cooling System Used in Transmitter


In high power A.M. transmitter, lot of power is dissipated in the valve as the input power is not
fully converted into output RF power due to the efficiency of the amplifier which never reaches
100%.Hence the valves have to be cooled. In addition filaments are drawing large current of the
order of 210 Amps at 10 volt for CQK valve. Hence they also have to be cooled. Hence some kind

32
of cooling has to be provided to the transmitting equipment. Different types of cooling are used
in AIR transmitter at present.

a) Air cooling
b) Vapour cooling system
c) Condensed vapour cooling

8.4.1 Air Cooling


At present forced air cooling is used in AIR transmitters. A blower sucks the air through an Air
filter and a guided duct system and the forced air is passed on to the required transmitting tubes.
There has to be minimum air flow to cool the valves. Hence there will be an air operated Air Flow
Switch (Relay) AFR : the AFR will close only when sufficient amount of air has been built up
with the blower. Otherwise, AFR will not close and filament cannot be switched on. Sometimes,
if the filter is not cleaned, sufficient air may not go out of the blower. Hence the blower needs
periodical cleaning.

Caution:

Do not by pass the AFR on any account. In case the AFR has failed but the blower is throwing the
required amount of air, the AFR may be shorted to bring the transmitter on air. But AFR should
be replaced at the earliest. At times if the 3 phase supply is phase reversed the blower may be
running. But air may not go to the valves and AFR will not close. On such rare occasions,
through Anemometer or by a paper flop the direction and the amount of air can be checked and
suitable steps can be taken to rectify the phase reversed. At present, transmitting tubes like BEL
3000, BEL 6000, BEL 25000 etc. are forced air cooled types of valves used in AIR transmitters.

8.4.2 Vapour Cooling System


This system is used in 100 kW BEL Transmitters. For very high power valves and efficient
cooling, air cooling is not sufficient. Hence some of the valves like BEL 15000, BEL 75000 etc.
are cooled by vapour cooling. (Hence called Vaptron). Here the principle of heat required to
convert water into steam at its boiling point is used (Latent heat of steam). The valves are kept in
a in-tight water container filtered and de-ionized water. This water has high resistivity and comes
in contact with anode. The water containers called "Boilers" are provided with inlet and outlet
pipes.

33
"------------, HEAT EXC>Wa:R t-----------AI

PRESSURE

li
EXII.W.lZN,
PIPE
NOTE:-
1. 'Im.ON PIPE
2. SPECIAL GLASS PIPE
J. RUBBER COUPUNG
4. COPPER PIPE

r lsERYO
TANK

CONTllOL BOX

r -,
I I
I I
I I
LEVEL L ..J
DETECTOR

Fig.8.1 Vapour Cooling System

The main features of this vapour cooling system are as follows:

This system is based on closed cycle operation and hence does not require large amount of
water.

The cooling efficiency is high. The amount of water flow required for water-cooling system
is about 2000 grams per minute to absorb 1 kW of heat whereas in this vapour cooling system
the amount of water flow required is only 20 grams per minute to absorb the same heat.

As water flows in a closed loop contamination due to atmospheric dust and dirt is eliminated
and hence the steam and water pipes are free of any deposition. The maintenance of this
system becomes easier and requires cleaning of anodes and associated piping assemblies only
periodically at long intervals.

Water level is maintained at the required normal level by the level monitor and water level
control mechanism. The system switches off the transmitter and gives as visual warning when
the water level goes down behind the empty level.

8.4.3 Condensed Vapour Cooling in HMB-140BEL 100 kW MW XTR:


In BEL/BBC solid state transmitter of 100 KW/300 kW MW and 50 KW/100KW/500KW SW
transmitters, condensed vapour cooling is used for the PA and modulator valves. Here a circulation of
fast flowing stream of de-mineralized water is used. A high velocity water flows through the valve

34
jacket and transforms into vapour due to the dissipation of power in anodes. The tubes are fitted with
a specially formed anode which sits in a cylindrical cooler. Due to the fast flow of water, the vapour
is condensed to water as soon as they are formed. Hence the cooling efficiency is much higher. The
temperature of water coming from the transmitter can theoretically reach about 90 0 C, but in practice,
it is desired to about 700 C in normal modulation.

The demineralized water is pumped by pumps (one in circuit and one as standby) from the water tank
to the PA and modulator tubes through the water piping.

DEIONIZER

GATE
VVE

GATE GATE !if.TE


VVE VVE VVE

If) II)
THERMOSTAT THERMOSTAT N THERMOSTAT N


CQl(-50 I
:!II:
0
u 8

WATER WI\TER
Ft.OW A.OW
SWITT:H SWITCH

PRESSURE CAUCE

Fig.8.2 Water Flow Circuit 100 kW HMB 140

The water flow rate is monitored by three flow switches at the outlet side of each tube. For PA
tube, the flow switch is set at 37.5 liters/minute and for modulator valve; it is set at 11.5
liters/minute.
The temperature of the water in the pipes is monitored by 3 thermostats one at the outlet of each
tube. These thermostats are set at an operating temperature of 900 C, the transmitter will trip

35
automatically to standby condition and WTR (Water Temperature High) indication comes up in
indicator panel.

Fig.8.3 Cooling Pipes

Chapter.9

ANTENNA TUNING UNIT

36
9.1 Introduction
Antenna Tuning Unit (ATU) is to match the feeder line impedance to the mast impedance of MW
Transmitters for maximum transmission of power. So ATU is located between the mast base and
the feeder line and is very close to the mast base. Commonly Feeder Unit which is located in
the aerial field, houses the ATU.

Generally the mast impedance (aerial impedance) is obtained in a complex form i.e. the real part
(resistive) and the imaginary part (reactive) component. When the mast impedance is expressed
in polar form then negative angle indicates the mast is capacitive and positive angle indicates the
mast is inductive. Whether the mast impedance is inductive or capacitive depends on the height
of the mast in terms of wave length ( D ). If the height is less than D /4, it will be capacitive and
inductive if more than D /4. This can be measured with impedance bridges.

Design of L Networks

9.2 L Networks

L networks consists of two elements of reactance. It could be inductance and capacitance in any
combination L-C, L-L, C-L, C-C. The network can be in the shape of L or inverted L
depending on impedance at the input and at output. If inductive reactance comes in series arm it is
a lagging network and when it is capacitive it is leading.

i. Phase lag (Rin> RL)

X L D RL (Rin D RL ) XL
XC Rin RL
RL
X C D Rin
Rin D RL
Fig. 9.1Phase lag (Rin> RL)
ii. Phase lag (RL>Rin)

37
X L D Rin (RL D Rin )
Rin XL XC RL
Rin

X C D RL
RL D Rin
Fig.9.2 Phase lag (RL>Rin)
iii. Phase lead (Rin> RL)

Rin D RL Rin XC
XL RL

X C D RL (Rin D RL )
Fig. 9.3 Phase lead
(Rin> RL)

iv. Phase lead (RL>Rin)

Rin XC
X L D RL RL D Rin Rin RL XL

X C D Rin (RL D Rin )

Fig. 9.4Phase lead (RL>Rin)

L networks are simple to implement and component losses are less. Phase angle D introduced
Rin . Therefore phase control is not possible with this network. is
equal to Cos
RL

9.3 Pi Networks

PI Networks can be designed in number of ways like

D By assuming phase shift

D By assuming the Q factor

D By splitting the network as two L networks

38
By assuming Phase shift

D Find the ratio n = R1/R2

D Assume the phase angle D from 0D to 180 D

XB

R1 XA Xc R2

Fig. 9.5 Pi Network

Then

n D Cos D
a =
nsin D

1
b =
D
n.Sin D

1
c = D n .Cos D
n .Sin D

Then XA = R2/a XB = R2/b XC = R2/c

In the above case for all phase angles the XB shall be positive and hence inductive , XA shall be
negative and hence capacitive. Whereas XC could be positive/negative depending on phase angle
selected. For some values of phase angle Pi network becomes L network.

39
By Assuming XB

For Stability XB2 D R1 . R2

Then ,

XXCA((XXBA DD XXCB)) D R1 /R2

XA = - R1.XB
R1 DD R1.R2 D XB2

XC = - R2.XB R2 DD R1.R2 D
XB2

Pi networks are flexible and can be designed for any phase shift. They can act as very good fitters
to suppress harmonics.

9.4 T Network

In some typical cases where L network is not possible it may be necessary to design T networks.
This can be designed as follows.

X1 X2

R1 R2
X3

40
Fig. 9.6 T Network

T Network between R1 and R2 is possibile only if X32 R1R2

X1 = R1 c, X2 = R1a , X3 =R1 b

n Cos
Where a =
nsin

1
b = -
n.Sin

1 n .Cos c
=
n .Sin

= Phase shift and n = R1/R2

Some times it is possible to design T networks with the load reactance as the X2 arm of the
above network. Therefore there will be only two components in the matching networks , means
it is an L network. T network can precisely control phase shifts and can tune wide range of
impedances.

41
Chapter.10

PRINCIPLES OF ANTENNA SYSTEM

10.1 Introduction

Antenna is usually a metallic device (as a rod or a wire) used for radiating or receiving
electromagnetic waves. The radio frequency power developed at the final stage of a transmitter
is delivered through cables/feeders, without themselves consuming any power to the transmitting
antenna. This travels in the free space in the form of radio waves (electromagnetic waves). The
receiving antenna picks up the radio waves and delivers useful signal at the input of a receiver for
reception of signals. The transmitting and receiving antennae are reciprocal in the sense, any
characteristics of the antenna in general applies equally to both.

10.2 The Function of an Antenna

The purpose of a transmitting aerial is to convert the power delivered by the transmission line into
a wave called an "Electro-magnetic wave." This electromagnetic wave is then radiated through
space. All aerials work on the same principle-the aerial current generates an electromagnetic field,
which leaves the aerial and radiates outwards as an electro-magnetic wave.

Fig.10.1 The Aerial Converts Electrical Power Into Electro-magnetic Waves

42
10.2.1 How an Aerial Works

If the wires of an open-ended transmission line are bent back at right angles to the line, at a point
one quarter wavelength back from the open end, a simple aerial is formed which is called either
a "half-wave dipole," a "doublet," or a "Hertz aerial." The voltage and current distribution on
this aerial are the same as on the original transmission line.

Fig. 10.2 Half Wave Dipole Aerial

Observe that the standing waves of voltage and current indicate that the aerial ends are points of
maximum voltage and minimum current; whereas the center of the aerial is a point of maximum
current and minimum voltage.

The voltage difference between the two wires of an aerial also generates an electrical field like a
charged capacitor which has a pattern and direction that you can see in the diagram (fig.3).

_,-::!-
llectrlc J'ield of a
Cbarled Condeuer
-
+
Electric Field Surroundin1
a# Al!lrld
'!

Fig. 10.3 Electric Field Surrounding an Aerial


Besides this electrical field, there is also a magnetic field, which is generated by the aerial current.
The plane of this magnetic field is at right angles to the direction of the current flow; and therefore

43
is at right angles to the aerial (see below). The electrical and magnetic fields are therefore at right
angles to each other.

Fig. 10.4 Magnetic Field Surrounding an Aerial

These electrical and magnetic fields alternate about the aerial building up reaching a peak
collapsing and building up again in the opposite direction, at the same frequency as the aerial
current. In the process of building up and collapsing a portion of these fields escape from the aerial
and become the electro-magnetic waves which radiate through space, conveying the transmitted
intelligence to distant receivers.

10.3 Basic aerials:

10.3.1 Hertz aerial:

The half wave dipole or Hertz aerial is used for Short Wave (SW) frequencies in All India Radio
network. This can be used at other high frequency also. Since at high frequency the overall length
becomes smaller. It can be made of metal tubing, which makes it self supporting.

10.3.2 Marconi aerial:

44
Another basic aerial is a vertical quarter-wave grounded aerial sometimes called a "Marconi
aerial." If one of the arms of a hertz aerial is removed, and the wire which went to that element is
earthed or grounded, the result is a Marconi aerial.

When a Marconi aerial is used the earth directly beneath the aerial must be a good electrical
conductor. To give good conductivity, the earth is simulated by placing metal rods or wire mesh
at the base of an aerial. This arrangement is called a "counterpoise earth." Since a
quarterwavelength dipole aerial is only half as long, it is often preferred at low frequencies (large
wavelength). In is used in medium wave frequencies in All India Radio.

VERTICAL }1./4 GROUNDID


AE1lAL (Marconi)

DIPOLI
ELEMEMT
.Y4
HALF-WAVE DIPOLE AERIAL
(Hertz)
I
_J

I
1
~4

I --
la-
I --- .Y2
I
I ;J
Fig.10.5 Basic Aerials

45
ruO
s11,,., CyllM,kall.Mllce
Vario," he tl teO.ffll

----- GU'f WIRE


GUY INSULATOR

AST BASE
INSUU\TOR

R
CUY ANCHO

Fig. 10.6 MW Antenna Isolated from ground

10.4 Antenna Radiation Resistance


The input impedance Zin of an antenna is the ratio of voltage to current at its input terminals where
the power is fed to the antenna.

Zin = Ra+jXa

Ra = Resistive part of impedance

Xa = Reactive part of impedance

Ra = Rr+Ri

Rr = Radiation resistance of the antenna

Ri = Ohmic loss resistance of the antenna.

It is through the mechanism of radiation resistance, power is transferred from the guided wave at
antenna input to the free space wave.

46
The reactive part of the input impedance is due to the storage of electric magnetic field (capacitive
and inductive reactance) in the near field of the antenna. The net reactive impedance of the
antenna can be matched with the conjugate impedance of the source driving the antenna.

Radiation Resistance is a fictitious term. It is equivalent of resistance which would dissipate the
same amount of power as being radiated by the antenna when fed with the same amount of power.

10.5 Radiation Efficiency


The radiation efficiency determines the effective transfer of power from the input to free space, and
given by

R
Radiation Efficiency = r

Ri Rr
10.5.1 Field Regions
D3
a) Reactive near field (induction field) up to a distance 0.62

2D2
b) Radiating near field (Fresnel field) beyond near field up to a distance of .

c) Far field (Fraunhofer field) beyond Fresnel field where 'D' is the largest dimension of the
antenna.

10.5.2 Isotropic Antenna


It is an imaginary (non-existent) point (dimensionless) antenna which radiates equally with unity
gain in all directions in three dimensional planes.

10.6 Radiation Pattern (Polar Diagram)


Graphical representation of the directional radiation properties of the antenna as a function of space
coordinates in three dimensions is called the radiation pattern. Such a representation will be
usually very complicated to interpret. It is usual practice to represent the same in two

47
dimensions for both horizontal and vertical planes. The length of vector from the centre or the
reference point is proportional to the power gain in that direction

""
:m

1 D

-D .
..:m ~.
...,
.... ,,_

Fig.10.7 Antenna radiation pattern

10.7 Half Power (3 dB) Beam Width


The angle between the two directions in which the radiation intensity is one half (3 dB below) the
maximum value of the beam.

Bandwidth of Antenna
The range of frequencies within which the performance of the antenna with respect to certain
characteristic (such as input impedance, pattern, beam width, polarization, side lobe level, beam
direction, gain)conforms to a specified standard. More commonly in broadcasting the
characteristics of importance are gain and input impedance.

10.8 Polarizations
The plane containing the electric vector in the electromagnetic wave describes the polarization of
the radiated wave. Ideally maximum signal is coupled if the antennae (both transmitting and
receiving) are oriented in the plane of polarization of the electro -magnetic wave. A vertical

48
radiator radiates/picks up vertically polarized wave, horizontal radiator radiates/picks up
horizontally polarized wave.

There are number of well defined polarizations such as horizontal (HP), vertical (VP), slant (+ 45o
(SP), circular (left or right) (LCP, RCP), dual (DP), mixed (MP), elliptical (left or right)
(LEP/REP) etc.

HP : The electric vector is in horizontal plane. TV broadcasting in India use horizontal


polarization.

VP : The electric vector is in the vertical plane. The self-radiating MW masts of AIR radiate VP
waves. Electric supply undertakings use vertical polarization for their VHF communications.

CP: The electric vector in circular polarization rotates in a circular motion. They may be
considered as the resultant of equal amplitude of vertical and horizontal polarized components
combined in phase quadrature (90o).

The polarization is said to be right or left circular polarized (RCP or LCP) depending on the
rotation of electric vector of the propagating wave clockwise or anti clockwise respectively, as
seen from the transmitting point or by an observer with his back to the transmitter.

INSAT down link signals are left hand circularly polarized.

10.9 Aperture of an Antenna 'A'


This term usually relates only to receiving antenna. Aperture (or effective area) of a receiving
antenna is the ratio of power delivered to the load (connected to the Antenna) to the incident power
density.

A G 2

4
where G is the gain with respect to the isotropic antenna.

49
10.10 SNAPSHOTS

' '

Fig.10.8 Antenna and guy wire insulator

50
Chapter.11

EARTHING SYSTEM

11.1 Earthing
Earthing is the connection of electrical equipment and wiring systems to the earth by a wire or
other conductor. The primary purpose of grounding is to reduce the risk of serious electric shock
from current leaking into uninsulated metal parts of an appliance, power tool, or other electrical
device. In a properly grounded system, such leaking current (called fault current) is carried away
harmlessly. Grounding is also used in manufacturing industries to prevent accumulation of
hazardous static electrical charges.

The function of earthing is two fold


1. It is for ensuring that no current carrying conductor rises to a potential with respect to
general mass of earth than its designed insulation.

2. It is for the safety of the human beings from the electric shocks.

11.2 Methods of Earthing


There are two popular methods of earthing :
i) Pipe Earthing (Fig. 1) ii) Plate
Earthing (Fig. 2)

11.3 Measurement of Earth Resistance


The determination of resistance between the earthing electrode and the surrounding ground is of
utmost importance. The resistance measurement is made by the potential fall method.

The resistance area of an earth electrode is the area of soil around the electrode within which a
voltage gradient measurable with commercial instrument exists.

In Fig. 11.3 E is the earth electrode under test and A is an auxiliary earth electrode positioned so
that two resistance areas do not overlap. B is a second auxiliary electrode placed half way between
E and A.

51
An alternating current of steady value is passed through the earth path from E to A and the voltage
drop between E and B is measured.

Then earth resistance R = V/I


V = Voltage drop between E and B
I = Current through the earth path.
To ensure that resistance areas do not overlap, the auxiliary electrode B is moved to positions B1&
B2 respectively. If the resistance values determined are of approximately same magnitude in all
the three cases, the mean of the three readings can be taken as the earth resistance of the earth
electrode. Otherwise the auxiliary electrode A must be driven in at a point further away from E
and the above test repeated until a group of three readings is obtained which are in good agreement.

The use of alternating current source is necessary to eliminate electrolysis effects.


The test can be performed with current at power frequency from a double wound transformer by
means of a voltmeter and an ammeter or by means of an earth tester.

The earth tester is a special type of meggar which sends AC through earth and DC through the
measuring instruments. It has got four terminals P1, C1, P2 and C2 outside. The terminals P1, and
C1 are shorted to form a common terminal which is connected to the earth electrode under test.
The other two terminals C2 and P2 are connected to the auxiliary electrodes A and B respectively
.

For measurement of earth resistance two electrodes A and B are driven into the ground at a distance
of 25 metres and 12.5 metres respectively from earth electrode E under test. The megger is placed
on a horizontal firm stand free from surrounding magnetic field. The range switch is set to a
suitable scale. The handle is then turned in proper direction at a slightly higher speed than rated
one and the reading on the scale is noted. The three readings are taken for different distance. If they
are practically the same, it is good otherwise average of these readings is taken as earth
resistance.

52
CEMENT CONCRLT J t11'1
(J!,f:8) lt1fl--

-,-
'

,scm

I?. !f) f!N} HOU -


SECT

Fig.11.1 Typical Arrangement of Pipe Earthing

53
lJOltm MS RtJO
Cl (OYEA' HINGE/)
T0(IFHAN

GROUNb
cers:

CEMENT Ctwt'A'ETE
(f:4:9)
'IIU1,GI

[
ism
(MIN)

-r
I

-fl

iox,4rmx&JQmm c1 ti 11'111,, GI A'N


Pt.ATE d G()ltQ/'111 X
JIS 111111 CdPPE,f Pt.ATE

ENLARCEO OETA!.

G()(!!J

15011

Fig.11.2 Typical Arrangement of Plate Earthing

54
SflFPI.Y
R/10$TAT

118
It '2
II
11
II
.,.,

tmv..
11 1I

EOUAl DISTAA'L l)ISTJtV!'E

Fig. 11.3 Testing of Earth Electrode Resistance

AAAAAAAAAAAAAAAAA
Vc(t) V V V VVVlJVV v vvv vv V\
v.(t ~

CRCUITS GfRRY/Nfi' DJRECT CURlilrNT---


,, "M.TERNAT/Nt; ,, ----

55
Fig.11.4 Earth Tester

REFERENCES

[1] http://prasarbharati.gov.in

[2] http://en.wikipedia.org/wiki/Mast_radiator

[3] http://en.wikipedia.org/wiki/Antenna_(radio)

[4] www.allindiaradio.org

[5] http://india.gov.in/knowindia/radio.php

56
[6] Electronic Communication Systems by George Kennedy

[7] Electronic Communication systems in advance by Wayne Tomasi

[8] Taubs Principles of communication by Herbert Taub, Donald L Schilling

[9] www.howstuffworks.com