Contents
XCEL 45 Specification Data 4
Hydraulic Circuit Explanation 5
Neutral Circuits: Open Center & Close Center 5
Neutral Circuits: Load Sensing 6
Work Circuits: Non-Load Reaction and Load Reaction 9
Steering Units with Integral Valves 10
Manual Steering 11
Dual Displacement 12
Eaton Patented Technology 13
Q-Amp Flow Amplification for Load Sensing Circuits 13
Cylinder Damping 14
STC Direct Porting 15
Model Code Customer Order Information 16
XCEL 45 Steering Control Unit 18
Installation Dimensions 18
Dual Displacement 19
Installation Drawing 19
XCEL 45 Steering Control Unit 20
Section Drawing and Integral Valves 20
Priority Valve Introduction 21
Description 21
Pressure Drop 22
Bolt on VLC Priority Valve (BOPV) 23
Dimension 23
Customer Order Information 23
VLC In-Line Priority Valves 24
Dimensions 24
Customer Order Information 24
VLE In-Line Priority Valves 25
Dimensions 25
Customer Order Information 25
VLC & VLE Relief Valve Pressure 26
VLH In-Line Priority Valves 27
Dimensions 27
Customer Order Information 27
Sizing and Application 28
Ackermann Type Steering 28
Articulated Type Steering 31
Articulated Vehicle Steering Analysis Form 33
Articulated Vehicle Steering Analysis Form 35

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 3


XCEL45 Steering Control Unit

Steering Control Units


The Steering Control Unit servo-type applications or XCEL45 Applications
(SCU) is fully fluid linked. any application where visual
positioning is required. The The XCEL45steering unit is Construction Machinery
This means there is no
close coupled, rotary action an innovative steering Agriculture Machinery
mechanical connection
valve performs all necessary platform that provides smooth
between the steering unit, Heavy-Duty Equipment
fluid directing functions and reliable steering.
the pump and the steering
cylinders. The unit consists with a small number of The XCEL45
is designed for Marine
of a manually operated moving parts. The manually mid-range flow applications. Forestry Machinery
directional control servo actuated valve is coupled The XCEL45 has robust Mining Equipment
valve and feedback meter with the mechanical drive to housing design which
element in a single body. the meter gear. The control provides 190 bar max
It is used principally for is lubricated and protected [2755 psi] system pressure
fluid linked power steering by the power fluid in the capability for all models
systems but it can be used system and can operate in
for some many environments.
Specification Data

Advantages Max.System Pressure 190 bar [2755 psi]


Max. Back Pressure 35 bar [500 psi]
Steering control units offer Provides a wide selection Rated Flow
the following advantages: of control circuits and 50 - 125cc/r 7.5-15 LPM [2-4 GPM]
Minimizes steering meter sizes. 160 - 250cc/r 15-30 LPM [4-8 GPM]
linkagereduces cost, Can work with many kinds 320 - 500cc/r 30-45 LPM [8-12 GPM]
provides flexibility of power steering pumps Input Torque
in design. or fluid supply. Powered Standard 1.7-2.8 Nm
Provides complete Powered Low Torque 1.3-2.2 Nm
isolation of load forces Features Powered Supper Low Torque <1.4 Nm
from the control Open Center Non-powered 136 Nm
stationprovides Max. System 93C [200F]
Load Sensing
operator comfort. Operating Temperature
Close Center
Provides continuous, Max. Differential Between 28C [50F]
unlimited control Q-amp Steering Unit and Other
action with very low System Temperature
Bolt on priority
input torque. Fluid
Dual Gerotor ATF Type A
and Most Petroleum Based Fluids
Integral Valves See Eaton Technical Bulletin 3-401
Cylinder Dampening Recommended Filtration:
ISO 20/18/13 cleanliness level

4 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014


Hydraulic Circuit Explanation
Neutral Circuits: Open Center & Close Center

Open Center
Simplest, most economical system
Uses a fixed displacement pump
L R
In neutral position pump and tank are connected
Most suitable on smaller type vehicles Gerotor

Applications
Lawn and Garden Equipment
Utility Vehicles

T P

Fixed
Displacement
Pump

Open Center System

Close Center
Uses a pressure compensated variable
displacement pump
In neutral position pump and tank are disconnected L R

Most suitable on large construction equipment

Applications
Construction Industry

T P

Pressure
Compensated
Pump

Closed Center System

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 5


Hydraulic Circuit Explanation
Neutral Circuits: Load Sensing

Load Sensing Circuits Pump-May be fixed System Main Relief


displacement, pressure Valve-A pressure relief valve
Load sensing power steering
compensated, or flow for the auxiliary circuit and/or
uses conventional or load
and pressure a main safety valve for the
sensing power supplies
compensated design. protection of the pump is
to achieve load sensing
Priority Valve-Sized for recommended and sized for
steering. The use of a load
design pressure drop at the maximum pump output
sensing steering unit and
maximum pump output flow rate. If a main relief
a priority valve in a normal
flow rate and priority flow valve is used, it must be
power steering circuit offers
requirements. The minimum set above the priority circuit
the following advantages:
control pressure must steering relief valve
Provides smooth pressure pressure setting.
assure adequate steering
compensated steering
flow rate and must be
because load variations in
matched with the steering
the steering circuit do not
control unit. A dynamic
affect axle response or Steering Cylinder
signal priority valve must be
maximum steering rate.
used with a dynamic signal
Provides true power steering control unit.
beyond system capability
Steering Control Unit-
by splitting the system Manual
Designed for specific Inputs L R
into two independent
rated flows and control
circuits. Pressure Load Sensing
pressures. It must be Steering Unit
transients are isolated in T P
matched with a control
each circuit. Only the flow High Pressure
pressure in the priority
required by the steering LS CF Carryover
valve to obtain maximum
maneuver goes to the Steering
steering rates. Higher flow
steering circuit. Flow not Relief EF
rates require higher control
required for steering is LS DS PP
pressures. Neutral internal
available for use in the T
bleed assures component
auxiliary circuits.
temperature equalization
Provides reliable operation Filter
LS Line-A LS line is always
because the steering
needed to sense pressure
circuit always has flow and P Priority Valve
downstream from the
pressure priority. Main
variable control orifice in the Relief
Dynamic Signal
Load sensing steering steering control unit. This
control units and priority is balanced by an internal
valves can be used with passage to the opposite side
open center, closed of the priority control spool. Filter

center or load sensing


The total system
systems. Use in an open
performance depends on Pump Prime Mover
center system with a fixed
careful consideration of the
displacement pump or a
control pressure chosen and
closed center system with
pressure drop in the CF line.
a pressure compensated
pump, offers many of the Steering Relief Valve-Must Tank

features of a load sensing be factory set at least 10


system. Excess flow is bar[145PSI] above the
available for auxiliary circuits. maximum steering cylinder
pressure requirement. Most
Listed below are the LS Load Sensing
of the flow will be directed
components of a typical load
to the auxiliary circuit (EF) DS Dynamic Signal
sensing control circuit and a
when the relief setting
brief application description. PP Pilot Pressure
is exceeded.
CF Control Flow
EF Excess Flow

6 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014


Hydraulic Circuit Explanation
Neutral Circuits: Load Sensing

Load Sensing Circuits: Signal Systems


Two types of load sensing signal systems are
available -Dynamic and Static
L R

Static Signal
In a Static Signal system, the pump and priority valve
senses a static pressure in the sensing line. The effective
control pressure is the pressure caused by the spring in the
Load Sensing
priority valve minus pressure losses in the control flow line. (Static Signal)
Steering Control Unit
Used for conventional applications where response or circuit (non-load reaction)
stability is not a problem. The load sensing pilot line should
not exceed 2 meters [6 feet] in length.

T LS P
Auxiliary
LS CF EF Circuit with
Open Center
Valve (s)

Proirity Valve
(Static Signal)
P

Fixed Displacement Pump

Load Sensing Steering System with


Fixed Displacement Pump
(Open Center Circuit)

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 7


Hydraulic Circuit Explanation
Neutral Circuits: Load Sensing

Dynamic Signal
In a Dynamic Signal system, the pump and priority valve senses a pressure in the load sensing line caused by the spring
and a small amount of flow through the dynamic signal orifice from the control flow line.
Used for more difficult applications. The Dynamic Signal systems offer the following benefits:
Faster steering response.
Improved cold weather start-up performance.
Increased flexibility to solve problems related to system performance and stability

L R

L R

Load Sensing
(Dynamic Signal)
Steering Control Unit
(non-load reaction)
Load Sensing
(Dynamic Signal)
Steering Control Unit
(non-load reaction)
T LS P
High Pressure
LS CF EF Carryover to
Auxiliary Circuit with T LS P
Open Center Valve(s) Auxiliary Circuit
LS CF EF with Load Sensing
T Valve(s)

Priority Valve T
(Dynamic Signal)
P Priority Valve
(Dynamic Signal)
P
Shuttle Valve Pilot Signal
from Auxiliary
Circuit
Fixed Displacement Pump
Pressure and Flow
Compensated Pump
Load Sensing Steering System with Fixed
Displacement Pump (Open Center Circuit) Load Sensing Steering System with Pressure and Flow
Compensated Pump (Closed Center, Load Sensing Circuit)

8 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014


Hydraulic Circuit Explanation
Work Circuits: Non-Load Reaction and Load Reaction

Non-Load Reaction
A non-load reaction steering unit blocks the cylinder ports
in neutral, holding the axle position whenever the operator
releases the steering wheel. L R

Gerotor Direct
Metering Mechanical
Mechanism Link

T P

Steering
Control Unit

Pressure and Flow


Compensated Pump

Non-Load Reaction Circuit

Load Reaction
A load reaction steering unit couples the cylinder ports
internally (in the neutral position) with the meter gear set.
Axle forces are then allowed to return the steering wheel to
L R
its approximate original position. Comparable to automobile
steering, gradually releasing the wheel mid turn will allow Gerotor Direct
Mechanical
the steering wheel to spin back as the vehicle straightens. Metering
Link
Mechanism
The cylinder system used with load reaction units must
have equal oil volume displaced in both directions. The
cylinders should be a parallel pair (as shown) or one double
rod end unit.
Do not use with a single unequal area cylinder system

T P
Steering
Control
Unit

Fixed
Displacement
Pump

Load Reaction Circuit

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 9


Steering Control Units with Integral Valve

Integral valves are available for the XCEL45 steering control


unit. Included are: Inlet Relief Valve, Cylinder Port Shock
Valves, LS-Relief Valve, and Anti-Cavitation Valves for
cylinder ports. In addition, a Manual Steering Check Valve for
1
limited manual steering is included.
The integral valves eliminate the need for a separate valve 2
block, and provides versatility to meet any steering
circuit standard.

Valve Description:
1 Anti-cavitation check valve for cylinder ports-
(R & L) protects steering circuit against vacuum
(cavitation) conditions.
2 Cylinder Port Relief Valves-R & L) protects hoses 3
against pressure surge created by ground forces on
the steered axle.
4
3 Manual Steering Check Valve**-converts unit to a
hand operated pump for limited manual steering.
**Steering units with displacements larger than 5
160 cc/r [9.8 in3/r] may require a separate power
source for limited operation.
4 Inlet Relief Valve-limits maximum pressure drop EF
across the steering unit protecting the
steering circuit.
5 Inlet Check Valve-prevents oil from returning through
the steering unit when pressure on the cylinder side
is greater than pressure on the inlet side to prevent
steering wheel kick.
6 LS-Relief Valve-Limits maximum pressure in the
steering circuit (LS units only)

10 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014


Manual Steering

Description 30-60 10-15 1-3


Displacement
RPM RPM RPM
c m 3/r [in 3/r]
The steering control unit can provide steering flow when
the pump or engine fails. It will pump oil through the meter [1000]
7 0

(gerotor) as the operator applies input or torque to the 40 63 80


steering wheel which provides limited manual steering. [2.4] [3.85] [4.88]
100
60
[6.1]
[ 800]
Use of Graph 125
50
1. Determine steering work port pressure required to [7.6]

preform the desired steer-ing maneuver from vehicle 160


[9.8]
test data. This defines the approximate manual steering [ 600]
40
pressure level required. Find this value on the vertical axis
[PSI] bar
and construct a horizontal line on the graph. 200
[12.2]
2. Find the input torque limit on the horizontal axis. Follow 30
this vertically until it crosses the required pressure [ 400]
250
line of step 1.
[15.2]
3. The maximum steering unit displacement is identified by 320 20
the first angled line to the left of this inter-section. [19.5]
[ 200]
400
[24.4] 10

0 0
0 27 54 81 108 136
[20] [40] [60] [80] [100]

Manual Input Torque


Nm [lb-ft]

1) Maximum flow less than 7,6 l/min [2 GPM].


2) Actual steering pressures required and manual steering capabilities must be verified with vehicle testing.
The above curves are intended as a design guide only.

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 11


XCEL45 Dual Displacement

Description and Features Manual steering


Capabilities in unpowered
The dual displacement Displacement Chart
mode
steering control unit allows
off road vehicles to retain Eliminates the need Gerotor 1 Gerotor 1 and 2
Manual displacement Powered displacement
manual steering capability of a back-up
while reducing the number emergency system. cm3/rev cm3/rev
of components in their 80 185
Engages the a small
system. By using two displacement in an
60 220
displacement in one unit unpowered mode and 60 260
the dual displacement allows manual steering. 60 310
offers a better solution to 80 205
manually steer a vehicle in Allows vehicles to meet
ISO/TUV road regulations 80 280
an unpowered mode without
the need of a back-up power 100 300
system. This simplifies the Performance in powered 125 285
design and provides a more mode 125 325
economical machine. Both gerotors are
The dual displacement engaged to steer
steering units use two the vehicle. Manual 60 cm3/r [3.6 in3/r]
gerotors and a pressure Same performance as Powered 244 cm3/r [14.9 in3/r]
controlled logic valve. The other Eaton steering units.
logic valve switches
between one displacement Additional Features 30
for manual steering and the 7.5
total of both displacements Steering circuit: Load 28
for powered operation. The Sensing Dynamic Signal 7.0
26
logic valve is spring returned Max. system 6.5
to the smaller manual pressure:190bar[2755 psi]. 24
displacement when inlet 6.0
pressure falls bellow 8 bar
Valve options and other 22

[120 psi].Above 8 bar[120psi] features: same as those 5.5


20
the logic valve connects available on other units 5.0
both gerotors to provide full Innovative low 18
4.5
powered displacement. noise design
16
4.0

Steering Flow l/min


e
od

14
dM

3.5
L R
rre

3.0 12
we
Po

2.5 10

2.0 8

1.5 6
de
1.0 ual Mo 4
Man
0.5 2

0 0

0 15 30 45 60 75 90 60 105 120

Input Speed RPM

Flow vs RPM (for each operating mode)


T LS P

12 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014


Eaton Patented Technology
Q-Amp (Flow Amplification) for Load Sensing Circuits

Description and Advantage Conventional Steering Control Unit

Q-Amp steering units have A typical Q-Amp unit has a


built in variable orifices that ratio of 1.6:1 which means
provide flow directly to the flow of the cylinder is
the cylinder without going 1.6 times the flow going Fast Rotary Meter
Valve
through the gerotor section. through the gerotor when Turn

The orifices do not open turning the steering wheel


until after the gerotor begins at medium to fast speeds.
to rotate and then gradually (See model code for
open until the desired available rations) Cylinder
Pump
flow is achieved which is
proportional to the flow
going through the gerotor.
Q-Amp Steering Control Unit Fast Turn

Features

Variable Ratio
Fast Rotary
Valve Meter
Turn
2:1

1.6:1

Pump Cylinder
Ratio

1:1

10 20 30 40 50 60 70 80 90 100 Q-Amp Steering Control Unit Slow Turn


RPM

6
No Flow
5
Turns Slow Rotary
4 Valve Meter
Turn
Lock
3
to
2
Lock
1
Pump Cylinder

10 20 30 40 50 60 70 80 90 100
RPM

Manual Steering Single Cylinder (Unequal area)


Steering a vehicle with loss of engine power may not On vehicles with one single unequal area cylinder the
be possible with a large displacement steering control steering wheel turns lock to lock are more in one direction
unit(SCU).Q-Amp with manual feature has the smaller than the other. When extending the rod one would get more
additional flow requirement of the larger displacement turns than when retracting it. A different Q-Amp ratio while
SCU for power steering. turning in one direction versus the other can be used to give
an equal number of turns lock to lock in each direction.

Covered By One or more of the following U.S. and foreign


Patents: 4759182, 4862690, 4781219. Unequal area Q-Amp.

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 13


Eaton Patented Technologies
Cylinder Damping

Description Benefits Flow Amplification without Cylinder Damping


Cylinder damping can help Reduces jerking motion
smooth the steering action on medium and large
of large articulated vehicles articulated vehicles.
such as loaders, scrapers, Damps or stabilizes
and skidders. These vehicles unstable systems.
have overhanging weight
with high inertial loads. This
energy is dissipated by the
cylinder damping orifices Applications Large
which bleed a small amount Articulated Vehicles
of flow from the cylinder Wheel Loaders
port to tank. Skidders
Cylinder Damping has Scrapers
3 different levels of
application. Three levels can
Flow Amplification with Cylinder Damping
be engineered to fit
your application.

Steering Control Units with Cylinder Damping


Patent No. 5080135

14 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014


Eaton Patented Technologies
STC Direct Porting

Retaining Housing
With the Snap-To-Connect (STC) Direct Porting option, the Backup
Ring Seal Release
Washer
fitting profile is machined into the SCU housing, eliminating Sleeve
the need for extra STC fittings. This revolutionary and O-Ring
patented porting technology provides leak-proof sealing and
has operating pressure capability exceeding
4500PSI (310bar). STC Port
STC Hose/
Connector

Benefits
STC Direct Ports provide a great opportunity for significant
cost savings compared to threaded fittings
Eliminates the need for assembly tools during installation
Eliminates installation variability
Improves ergonomics - reduces installer effort to connect
Improves serviceability
High quality, leak-proof seal
Eliminates connector leakage
Compact design and overall lighter weight

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 15


Model Code The following 31-digit coding system has been developed
to identify all of the configuration options for the XCEL45
Customer Order Information steering control units. Use this model code to specify a unit
with the desired features. All 31-digit of the code must be
present when ordering. You may want to be photocopy the
matrix below to ensure that each number is entered in the
correct box.

This model code shows Preferred Products only. For a complete model code listing all available options, please contact your Eaton representative.

A S L 1 A A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

Nos Feature Code Festure Description Nos Feature Code Festure Description
1 2 3 Product Series ASL Series Xcel45 Steering Control 13 14 Valve Options MSC ICV IRV ACV CRV LSRV

MSC = Maual 01
4 Unit Type A Standard Steering
B Dual Displacement Check Valve 02
ICV = Inlet 03
5
Nominal Flow 1 11.3 L / min [3.00 gal/min] Check Valve
Rating 2 22.7 L / min [6.00 gal/min] IRV = Inlet 04
3 45 L / min [12.00 gal/min] Relief Valve
4 37 L / min [10.00 gal/min] Q-AMP CRV = Cylider 05
5 75 L / min [20.00 gal/min] Q-AMP Relief Valve
ACV = Anti- 06
6 Inlet Pressure 1 190 bar [2755 lbf/in2] Cavitation
Rating Relief Valve 07
LSRV= Load 08
7 Return A 21 bar [ 300 lbf/ in2] Maximum Sensing
Pressure B 10 bar [ 145 lbf/ in2] Maximum Relief Valve 09
Rating ( For low input torque) 10
11
8 9 Displacement 01 40 cm3/r [2.4 in3/r] 12
02 50 cm3/r [3.1 in3/r] 13
03 63 cm3/r [3.85 in3/r] 14
04 80 cm3/r [4.88 in3/r] 15
05 100 cm3/r [6.1 in3/r] 16
06 125 cm3/r [7.6 in3/r]
07 160 cm3/r [9.8 in3/r] 15 16 Inlet or Load 00 NONE
08 200 cm3/r [12.2 in3/r] Sensing Relief 04 75 bar [1087 lbf/in2]
09 250 cm3/r [15.2 in3/r] Valve Setting 05 65 bar [940 lbf/in2]
10 320 cm3/r [19.5 in3/r] 06 85 bar [1230 lbf/in2]
11 400 cm3/r [24.4 in3/r] 07 115 bar [1670 lbf/in2]
12 500 cm3/r [30.5 in3/r] 08 60 bar [870 lbf/in2]
13 240 cm3/r [14.4 in3/r] / 80 cm3/r [4.8 in3/r] 09 63 bar [915 lbf/in2]
14 280 cm3/r [16.8 in3/r] / 80 cm3/r [4.8 in3/r] 10 70 bar [1015 lbf/in2]
15 220 cm3/r [13.2 in3/r] / 60 cm3/r [3.6 in3/r] 11 80 bar [1160 lbf/in2]
16 310 cm3/r [18.9 in3/r] / 60 cm3/r [3.6 in3/r] 12 90 bar [1305 lbf/in2]
17 300 cm3/r [18.3 in3/r] / 100 cm3/r [6.1 in3/r] 13 95 bar [1377 lbf/in2]
18 260 cm3/r [15.9 in3/r] / 60 cm3/r [3.6 in3/r] 14 100 bar [1450 lbf/in2]
19 205 cm3/r [12.5 in3/r] / 80 cm3/r [4.8 in3/r] 15 105 bar [1522 lbf/in2]
20 185 cm3/r [11.3 in3/r] / 60 cm3/r [3.6 in3/r] 16 110 bar [1595 lbf/in2]
21 325 cm3/r [19.8 in3/r] / 125 cm3/r [7.6 in3/r] 17 120 bar [1696 lbf/in2]
27 160 cm3/r [9.8 in3/r] / 60 cm3/r [3.6 in3/r] 18 125 bar [1812lbf/in2]
19 130 bar [1885 lbf/in2]
10 Flow] A NONE (NO Q-AMP) 20 140 bar [2030 lbf/in2]
Amplication B 1.60:1.00 21 150 bar [2175 lbf/in2]
C 2.00:1.00 `` 22 155 bar [2247 lbf/in2]
23 160 bar [2320 lbf/in2]
11 Neutral Circuit A Open Center 24 165 bar [2392 lbf/in2]
B Lond Sensing, Static signal 25 175 bar [2537 lbf/in2]
C Lond Sensing, Dynamic signal 26 180 bar [2610 lbf/in2]
D Close Center 28 190 bar [2755 lbf/in2]
29 135 bar [1960 lbf/in2]
12 Load Circuid A Non-Load Reaction 30 170 bar [2465 lbf/in2]
B Load Reaction 31 142 bar [2059 lbf/in2]

16 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014


Model Code The following 31-digit coding system has been developed
to identify all of the configuration options for the XCEL45
Customer Order Information steering control units. Use this model code to specify a unit
with the desired features. All 31-digit of the code must be
present when ordering. You may want to be photocopy the
matrix below to ensure that each number is entered in the
correct box.

This model code shows Preferred Products only. For a complete model code listing all available options, please contact your Eaton representative.

A S L 1 A A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

Nos Feature Code Festure Description Nos Feature Code Festure Description
17 18
Cylider Relief 00 None 22
Mounting A 4-M10X1.5 Mounting Threads
Valve Setting 07 115 bar [1670 lbf/in2] Mounting Face
14 100 bar [1450 lbf/in2] Thread B 4-3/8-16 Mounting Threads
15 105 bar [1522 lbf/in2] Mounting Face
16 110 bar [1595 lbf/in2]
17 120 bar [1740 lbf/in2] 23 Mounting A NONE
18 125 bar [1812 lbf/in2] Threads
20 140 bar [2030 lbf/in2] Port Face
21 145 bar [2102 lbf/in2]
22 150 bar [2175 lbf/in2] 24 Mechanical A Internal Involute Spline,
23 160 bar [2320 lbf/in2] 12 Teech 16/32 DP
25 175 bar [2537 lbf/in2] Interface 30 Degree PA
27 185 bar [2682 lbf/in2]
28 190 bar [2755 lbf/in2] 25 Input Torque 1 Low
29 200 bar [2900 lbf/in2] 3 Standard
30 210 bar [3045 lbf/in2] 2 Super Low
31 220 bar [3190 lbf/in2] 4 Neutral Low ( For Q-amp Feature )
32 225 bar [3262 lbf/in2]
33 230 bar [3335 lbf/in2] 26 Fluid Type A Reference Eaton Techincal
34 235 bar [3407 lbf/in2] Bulletin 3-401
35 240 bar [3480 lbf/in2]
27 28 Special AA NONE
36 250 bar [3625 lbf/in2]
Features
37 195 bar [2830 lbf/in2]
38 205 bar [2972 lbf/in2] 29 Paints & 1 Black Paint
Packaging 2 Blue Paint
19 P,T,L and R A 4X M18 x 1.5-6H Metric Port
Port Size B 4X M18 x 1.5-6H Metrc O-ring Port 30 Identification 0 Eaton Product Number On Namplate
C 4X M20 x 1.5-6H Metric Port 1 Bar Code, Customer Number On
D 4X M20 x 1.5-6H Metric O-ring Port Name Plate
E 4X G .500 BSP Straight Thread Port
J 4X .750-16 UNF-2B SAE O-ring Port 31 Design Code A 001
M Bolt On Valve

20 21 Additional AA NONE
Port (LS Port) AB M12 x 1.5-6H Load Sensing Metric Port
AC M12 x 1.5-6H Load Sensing Metric
O-ring Port
AD G .250-19 BSP Straight Thread Load
Sensing Port
AF .4375-20 UNF-2B Load Sensing
SAE O-ring Port
AH Bolt On Valve Load Sensing Port On
Port Face
AJ .4375-20 UNF-2B Load Sensing SAE
O-ring Port On Port Face
AK G .250-19 BSP Straight Thread Load
Sensing Port On Port Face

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 17


XCEL45 Steering Control Unit
Installation Dimensions

D
Column Mounting Thread Load Sensing Port
28 [1.10] Location 'A' 57 [2.24]
44 [1.73] M10X1.5 Depth 15.5 on Load Sensing Port
2.8 [0.11]
Right 82.5 Dia. Bolt Circle(4) 14 [0.55] Location 'B'
Left 22 [0.87]

49 [1.92]
44.4 [1.74] MAX

88 [3.464]
25.4 [1.00]

44 [1.73]

82 [3.22]
60 [2.36]

12 Tooth Involute
Tank M12X1.75 Pressure
Spline 16/32 D.P. 82 [3.22]
6.9 [0.27]
14.7 Deep(2) 30P.A. 14.9 Deep
7.8 [.30] Min
Not available with
10.1 [.40] Max
location 'B' LS port
(6.8 [.27] Min Mating)

Load Sensing Port Load Sensing Flange Displacement Dimension B


Options: Port Thread Thread
cm3/rev mm
M18X1.5 M12X1.5 M10X1.5
Option A- Only used for LS 50 126.5
units with LS relief valve in M18X1.5 O-ring M12X1.5 O-ring M10X1.5 63 128
priority valve M20X1.5 M12X1.5 M10X1.5 80 130.5
Option B- Only used for LS M20X1.5 O-ring M12X1.5 O-ring M10X1.5 100 133
units with LS relief valve in G-1/2 BSP G-1/4-19 BSP M10X1.5 125 136
steering unit 3/4-16 UNF 7/16-20 UNF M10X1.5 160 141
3/4-16 UNF 7/16-20 UNF 3/8-16 UNC 200 146
250 152
320 162
400 172
500 184

18 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014


Dual Displacement
Installation Drawing

D Load Sensing Port Load Sensing Port


Location 'A' Location 'B'
A 14 [0.55]

Column Mounting Thread


28 [1.10] 44 [1.73] M10X1.5 Depth 15.5 on
2.8 [0.11]
22 [0.87] Right 82.5 Dia. Bolt Circle(4)
Left

49 [1.92]
88 [3.46] MAX
44.4 [1.74] MAX

25.4 [1.00]

44 [1.73]

82 [3.22]
60 [2.36]
12 Tooth Involute 57 [2.24]
Tank M12X1.75 Pressure Spline 16/32 D.P.
6.9 [0.27]
14.7 Deep(2) 30P.A. 14.9 Deep 78 [3.07]
7.8 [.30] Min Not available with
10.1 [.40] Max 82 [3.22]
location 'B' LS port
(6.8 [.27] Min Mating)

Load Sensing Port Options: Displacement Dimension Dimension


Powered (Manual) A D
Option A- Only used for LS units with LS relief valve in CC/R mm mm
priority valve
185 (60) 121.2 191.5
Option B- Only used for LS units with LS relief valve in 220 (60) 121.2 197
steering unit
260 (60) 121.2 203.8
310 (60) 121.2 213.5
Port Load Sensing Thread Flange Thread 205 (80) 124.7 195
M18X1.5 M12X1.5 M10X1.5 280 (80) 124.7 207.3
M18X1.5 O-ring M12X1.5 O-ring M10X1.5 300 (100) 128.2 210.8
M20X1.5 M12X1.5 M10X1.5 285 (125) 133 208.8
G-1/2 BSP G-1/4-19 BSP M10X1.5 325 (125) 133 215.6
3/4-16 UNF 7/16-20 UNF M10X1.5

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 19


XCEL45 Steering Control Unit
Section Drawing and Integral Valves

AA
Inlet Check Valve

BB
Inlet Relief Valve
or
FF
LS Relief Valve

CC
Inlet Check Valve for Limited Manual Steering

DD
Cylinder Relief Valve

EE
Anti-cavitation Valve for Cylinder Port

AA BB

CC DD

EE FF

20 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014


Priority Valve
Introduction

The load sensing priority valve separates the steering and There are 4 types of Priority Valve
auxiliary functions. The flow is supplied first on a priority BOPV: The Priority Valve is designed mounted onto
basis to the steering circuit (CF) to satisfy the steering
Steering unit directly, which will save room for installation.
requirements. All remaining flow is directed to the auxiliary
circuit (EF). When steering is inactive all flow goes to the VLC / VLE / VLH: In-Line designed Priority Valve, Need a
auxiliary circuit (EF). LS Line to connect LS Ports in Steering Control Unit and
Priority Valve
There are two types of signals available: static and dynamic.
In a static signal system, the pump and priority valve senses
a static pressure in the sensing line.
Specifications:
Static Signal Priority Valve must be used with Static Signal
Load Sensing SCU. BOPV
In a dynamic signal system, the pump and priority valve Rated flow: 60LPM
senses a pressure in the load sensing line caused by the
spring and a small amount of flow through the dynamic Load circuit: Dynamic signal
signal orifice from the control flow line. Rated inlet pressure: 241 bar
Dynamic Signal Priority Valve must be used with Dynamic
Signal Load Sensing SCU VLC
Rated flow: 60LPM
Static signal Load circuit: Dynamic signal & Static Signal
Rated inlet pressure: 241 bar
LS CF EF Max. LS Relief Valve: 190 bar

VLE
Rated flow: 150LPM
Load circuit: Dynamic signal & Static Signal
T Rated inlet pressure: 241 bar
Max. LS Relief Valve: 190 bar

VLH
Rated flow: 240LPM
Load circuit: Dynamic signal & Static Signal
P
Rated inlet pressure: 241 bar
Max. LS Relief Valve: 190 bar
Dynamic signal

LS CF EF

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 21


Priority Valve
Introduction

VLC Series Pressure drop Curve

VLE Series Pressure drop Curve

VLH Series Pressure drop Curve

22 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014


Priority Valve
Bolt On VLC Priority Valve (BOPV)

The Bolt On VLC Priority Benefit:


Valve is designed to be Packaged design,
directly mounted onto the
eliminating connecting
port face of a Load Sensing
pipes and save the
Steering Control Unit. Part Number
installation room.
Control Pressure ( Bar)
Port & Thread 5.2 7.6 10
Dimensions
P&EF- G1/2-14 880-1450 880-1480 880-1490
108 [4.25] R&L&T-3/8-19
P&EF-M20X1.5 880-1550 880-1580 880-1590
Pressure R&L&R-M18X1.5
35.9 [1.40] Tank
Port P&EF-G1/2-14 880-1750 880-1780 880-1790
Port
R&L&R-G1/2-14

The BOPV is ordered by a


45.8 [.80]

product number ( together


with Eaton Xcel45 Units)

880-1450
45.8 [.80]

Product Number

Please contact Engineering for more information

Excess Flow
Port
20.8 [0.81]

74.7 [2.91]

Right
Port Left
44.0 [1.72]
Port

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 23


Priority Valve
VLC in Line Priority Valve

Dimension A B
With LS relief valve (SAE thread) 143 41
With LS relief valve Metric &R (BSP) 166 64
Without LS relief valve 126 24

Priority Valve is ordered


by a product number

881 - 1203 - 065

System Pressure Code Number


Product Number for VLC In-Line Priority Valve

VLC In-Line Priority Valve

Port & Thread Signal Type & Control Pressure Bar [PSI]
Dynamic Static Dynamic Static Dynamic
5.2 [75] 5.2 [75] 7.6 [110] 6.9 [100] 10.0 [145]
P&EF: 7/8-14 UNF 881-2101 / 881-2102 881-1103 881-2103
CF: 3/4-16 UNF
LS&T:7/16-20 UNF
P&EF: M22X1.5 O-ring 881-2201 881-1202 881-2202 881-1203 881-2203
CF: M18X1.5 O-ring
LS&T: M12X1.5 O-ring
P&EF: G1/2-14 881-2301 881-1302 881-2302 881-1303 881-2303
CF: G1/2-14
LS&T: G1/4-19
P&EF: M22X1.5 881-2501 881-1502 881-2502 881-1503 881-2503
CF: M18X1.5
LS&T: M12X1.5
Note: Select a number from this table and take reference of the connection dimensions of Steering Control Unit on
Page 18 & Page 19.
Please always show your selected product number when you place an order.

24 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014


Priority Valve
VLE in Line Priority Valve

Dimension A B
With LS relief valve (SAE thread) 186 41
With LS relief valve Metric &R (BSP) 209 64
Without LS relief valve 169.5 24.4

Priority Valve is ordered


by a product number

882 - 1103 - 065

System Pressure Code Number


Product Number for VLE In-Line Priority Valve

VLE In-Line Priority Valve

Port & Thread Signal Type & Control Pressure Bar [PSI]
Static Dynamic Static Dynamic
6.9[100] 8.6[125] 10.3[150] 12.8[185]
P&EF: 1-1/16-12 UNF / 882-2302 882-1303 882-2303
CF: 3/4-16 UNF
LS&T: 7/16-20 UNF
P&EF: G3/4-14 882-1702 882-2702 882-1703 882-2703
CF: G1/2-14
LS&T: G1/4-19
P&EF: M27X2 O-ring 882-1902 882-2902 882-1903 882-2903
CF: M22X1.5 O-ring
LS&T: M12X1.5 O-ring
Note: Select a number from this table and take reference of the connection dimensions of Steering Control Unit on
Page 18 & Page 19.
Please always show your selected product number when you place an order.

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 25


VLC & VLE In-Line Priority Valve
Customer Order Information

System Pressure Code Number

Number Bar [psi] Number Bar [psi] Number Bar [psi]

017 78 1125 037 112 1625 056 145 2100


018 79 1150 038 114 1650 057 147 2125
019 81 1175 039 116 1675 058 148 2150
020 83 1200 040 117 1700 059 150 2175
021 84 1225 041 115 1725 060 152 2200
022 86 1250 042 121 1750 061 153 2225
023 88 1275 043 122 1775 062 155 2250
024 90 1300 044 124 1800 063 157 2275
026 93 1350 045 126 1825 064 159 2300
027 95 1375 046 128 1850 065 160 2325
028 97 1400 047 129 1875 066 162 2350
029 98 1425 048 131 1900 067 164 2375
030 100 1450 049 133 1925 068 166 2400
031 102 1475 050 134 1950 069 167 2425
032 103 1500 051 136 1975 070 169 2450
033 105 1525 052 138 2000 071 171 2475
034 107 1550 053 140 2025 072 172 2500
035 109 1575 054 141 2050 073 174 2525
036 110 1600 055 143 2075 076 179 2600

Note: If there is not a relief valve, the system pressure code number is 000. Select a pressure code from this table and
include it in the product number you determined.
Please always show your selected product number when you place an order.

26 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014


Priority Valve
VLH in Line Priority Valve

Dimensions VLH In-Line Priority Valve


Port & Thread Signal Type & Control Pressure Bar [PSI]
Dynamic Dynamic
5.9[85.5] 11.4[165.3]
P&EF: 1-5/8-12 UNF / 883-2203
CF: 1-1/16-12 UNF
LS&T: 7/16-20 UNF
P&EF: M42X2 O-ring 883-2702 883-2703
CF: M27X2 O-ring
LS&T: M12X1.5 O-ring.
Note: Select a number from this table and take reference of the connection
dimensions of Steering Control Unit on Page 18 & Page 19.
Please always show your selected product number when you place an order

Priority Valve is ordered


by a product number

883 - 2702 - 065

System Pressure Code Number


Product Number for VLH In-Line Priority Valve

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 27


Sizing and Application-
Ackermann Type Steering

Step One: Kingpin Torque F


Minimum
Effective
r Radius Arm
0.7

0.6

0.5

0.4
f
0.3
S
0.2

0.1
B

0.2 0.4 0.6 0.8 1.0 1.2 E

E/B

Typical values based on rubber tired vehicles on


dry concrete. V

T = w f B2
8
+ E2

Weight
W
T = Total Kingpin Torque required to steer axle.
W = Vehicle Weight supported by the steered axle.
f = Coefficient of friction (dimensionless). Based on 0.7 as
a Maximum. Determine from chart at left. A

B = Nominal width of the tire print (see diagram above).


E = Kingpin Eccentric (use nominal tire width).

Kingpin

Actual
Length

Radius Arm

28 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014


Sizing and Application
Ackermann Type Steering Continued

Step Two: Differential Cylinder Cross Connected Cylinder

Force Required

T
F =
r d
D

F = Force required for the axle.


T = Kingpin torque as determined in Step 1. The value
calculated in Step 1 is the total torque for the axle. If
D=
4A

+ d2

( )<
the steered axle is power driven, double this value to 2 2A d2
d D= +
ap- proximate the additional dynamic loads. Note: .15
D 2
r = Effective radius arm about the kingpin axis at which
the cylinder force is applied. The effective radius is
Balanced Cylinder Opposed Cylinder
the mini mum distance from kingpin to the axis of the
cylinder not the actual length of the arm.

Cylinder Area

E
A =


P
4A 4A
D= + d2 D=
A = Cylinder area for the axle cylinder set.
F = Force required
P = Hydraulic pressure
Cylinder Stroke
For vehicle with a steered axle that can never be overloaded
use 80% of the steering circuit relief valve setting. For S = Stroke Length
moderately loaded vehicles use 60%. For vehicles that can The cylinder stroke is determined by axle geometry. That is,
be severely overloaded use 30%. the required stroke is a function of the radius arm and the
total angle through which the arm turns.
Cylinder Diameter
Once the required cylinder set area is determined, the
Differential Cylinder
cylinder diameter can be calculated. V=Sx X D2
(Large Volume) 4
D = Inside diameter of cylinder.
d = Rod diameter as required. Differential Cylinder
(Small Volume or
Balanced Cylinder)
V=Sx

4 ( D2 d2
)
( )
Cross Connected
Cylinder V=Sx 2D2 d2
4

Cylinder Volume V = Volume V=SxA

The volume of oil required to move cylinder rod(s) through


the entire stroke.

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 29


Sizing and Application
Ackermann Type Steering Continued

Step Three: Step Four:

Selecting Steering Calculating Required


Unit Displacement Pump Flow
Before proceeding further, a decision must be made as to Pump sizing is important to assure adequate power for
the number of steering wheel revolutions desired for the steering under all operating conditions. The required pump
application to steer the axle from full one side to the other. flow can be calculated by the following equation.
Depending on vehicle usage, this will vary, normally 2 1/2 to
5 1/2 with 4 being a good typical value QP = Rmax. x displ.
QP (L/min): Required pump flow.
V
Displ. = Rmax = Max. steering wheel input of steering
N
control unit (SCU).

V = Volume full stroke displ. = Displacement of steering control unit


per revolution.
N = number of steering wheel revolutions lock to lock
Once this calculation is complete, select the closest Before proceeding to evaluation required pump flow
standard steering unit displacement from the catalog the maximum required steering wheel speed must be
information. determined. Typically 120 revolutions per minute (RPM) is
used for Rmax.
Now the number of steering wheel revolutions should be
recalculated. It is important at engine low idle condition that the
maximum steering wheel speed should be more than
V 60 rpm.
N =
displ. For engine normal idle condition, maximum steering
wheel speed should be more than 100 rpm if possible.
displ. = Steering unit displacement per revolution. When using open center SCU connected with pump
Note: for different cylinder applications, the cylinder volume will be directly, maximum pump flow should be less than 1.4
different for right and left turns and the value N will vary accordingly. times of SCU rated flow. Higher flow into SCU increases
pressure-loss of the steering system. If higher flow is
unavoidable, install a flow divider valve into the system or
use a load sensing system.

30 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014


Sizing and Application
Articulated Type Steering

Eatons Hydraulic Division has developed a computer program to assist articulated vehicle designers with a steering system
analysis. The analysis can provide basic system sizing and pressure requirement.
This analysis is intended to be used as a guide only and is not to be used solely as the final determination of system
design. Other factors and variables will have to be considered.
To receive output from this program, provide the required information by using the form on the following page.
Contact an Eaton Hydraulics Division Sales Representative

Twin Cylinders with a Single Wheel Set Twin Cylinders with a Dual Wheel Set

Forward Forward

E1 E1

C1 C1
CG1 CG1

OS1 OS1
B1 B1

OS2 OS2
B2 B2

CG2 C2 CG2 C2

E2 E2

S1 S1

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 31


32 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014
Sizing and Application Clip out this form or photocopy when needed.

Articulated Vehicle Steering Analysis

Manufacturer

Vehicle Type

Model Number

Completed By ______________________________________________________________________ Date

Indicate Unit of Measurement Used

1. Turns Lock to Lock__________________________________ 19. Weight - Rear Axle

2. Time Lock to Lock__________________________________ Unloaded__________________________________________

3. Max. Steering Wheel RPM___________________________ 20. Weight - Front Axle


Loaded____________________________________________
4. Cylinder Rod Diameter_______________________________
21. Weight - Rear Axle
5. Cylinder Bore Diameter______________________________
Loaded____________________________________________
6. Cylinder Stroke_____________________________________
22. Articulation Angle (lock to lock)_______________________
7. Pump: GPM Hi Idle__________________________________
23. Steering Circuit Line Size, Lengths, Type, Location
GPM Lo Idle________________________________________ (please note on schematic ref. 10.) ___________________
8. Steering Relief Pressure_____________________________ 24. Is Steering Through Brakes
9. Auxiliary Relief Pressure_____________________________ Statically Required?_________________________________

10. Hydraulic Schematic (attach) _________________________ 25. Are Locking Differentials Used?

11. B1________________________________________________ Front ____________ Rear _____ Both____________________

12. B2________________________________________________ 26. Is There A Differential Between the Front and Rear
Differentials? Yes _________ No______________________
13. C1________________________________________________
27. Tire Size ______________ Pressure_____________________
14. C2________________________________________________
Width ________________ Ballast_______________________
15. E1________________________________________________
Note:
16. E2________________________________________________
1-10 Should always be completed; this information is needed for basic
17. S1________________________________________________ steering system sizing.
1-27 Needed for sizing and an analysis of steering pressure
18. Weight - Front Axle
characteristics.
Unloaded__________________________________________

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 33


34 EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014
Sizing and Application Clip out this form or photocopy when needed.

Articulated Vehicle Steering Analysis

Manufacturer

Vehicle Type

Model Number

Completed By ______________________________________________________________________ Date

Indicate Unit of Measurement Used

1. Turns Lock to Lock__________________________________ 19. Weight - Rear Axle

2. Time Lock to Lock__________________________________ Unloaded__________________________________________

3. Max. Steering Wheel RPM___________________________ 20. Weight - Front Axle


Loaded____________________________________________
4. Cylinder Rod Diameter_______________________________
21. Weight - Rear Axle
5. Cylinder Bore Diameter______________________________
Loaded____________________________________________
6. Cylinder Stroke_____________________________________
22. Articulation Angle (lock to lock)_______________________
7. Pump: GPM Hi Idle__________________________________
23. Steering Circuit Line Size, Lengths, Type, Location
GPM Lo Idle________________________________________ (please note on schematic ref. 10.) ___________________
8. Steering Relief Pressure_____________________________ 24. Is Steering Through Brakes
9. Auxiliary Relief Pressure_____________________________ Statically Required?_________________________________

10. Hydraulic Schematic (attach) _________________________ 25. Are Locking Differentials Used?

11. B1________________________________________________ Front ____________ Rear _____ Both____________________

12. B2________________________________________________ 26. Is There A Differential Between the Front and Rear
Differentials? Yes _________ No______________________
13. C1________________________________________________
27. Tire Size ______________ Pressure_____________________
14. C2________________________________________________
Width ________________ Ballast_______________________
15. E1________________________________________________
Note:
16. E2________________________________________________
1-10 Should always be completed; this information is needed for basic
17. S1________________________________________________ steering system sizing.
1-27 Needed for sizing and an analysis of steering pressure
18. Weight - Front Axle
characteristics.
Unloaded__________________________________________

EATON XCEL45 Steering Control Units E-STCU-CC002-E October 2014 35


Eaton Eaton Eaton Fluid Power Limited
Hydraulics Business USA Hydraulics Business Europe 145 Off Mumbai Pune Road
14615 Lone Oak Road Route de la Longeraie 7 Pimpri
Eden Prairie.MN 55344 1110 Morges Pune 411018
USA Switzerland India
Tel: 952-937-9800 Tel: +41(0)21 811 4600 Tel: +91 20 6611 8200
Fax: 952-294-7722 Fax: +41(0)21 811 4601 enquiryindia@Eaton.com
www.eaton.com/hydraulics www.eaton.eu/Europe/Hydraulics

Eaton Fluid Power Eaton Hydraulics (PTY) LTD Eaton FZE (Dubai Branch)
No.11 Building South Africa Dubai Techno Park
No.330 Xiya Road 3 Eaton Africa Place, Aeroport PO Box 261768
F.T.Z. Pudong Kempton Park 1620 - Gauteng Dubai, United Arab Emirates
Shanghai 200131 South Africa Tel: +9714-8066100
China Tel: +27 11 961 2400 Fax: +9714-8894813
Tel: +86-21-3850-3300 Fax: +27 11 961 2500 www.eaton.ae
Fax: +86-21-5046-2903 InfoSA@eaton.com
www.eaton.com.cn

Eaton Eaton
Electrozavodskaya street 33 bld.4. Huzur Mahallesi
Moscow Imam esme Yolu Caddesi
107076 Candan Sokak No: 3
Russian Federation Ayazaga-Sisli/Istanbul
Tel: +7 495 981 37 70 34396
Fax: +7 495 981 37 71 Turkey
eatonhydraulicsrussia@eaton.com Tel: +90 212 331 4500
www.eaton.ru/EatonRU/index.htm Fax: +90 212 331 4690
hidrolik@eaton.com

2014 Eaton
All Rights Reserved
Printed in USA
Document No. E-STCU-CC002-E
October 2014

You might also like