You are on page 1of 3

Infiltration Ponds

Length of Pond Bottom (ft) 150 Width of Pond Bottom (ft) 10


Area of Bottom of Pond (acres) 0.03
Pond Side Slopes (3:1 typical) 4

Depth to Hydraulic Area of Pond Adjusted


Depth of Hydraulic Infiltration Length Width of
Water Table, Conductivity, Bottom, CFsize CFaspect CFsilt/bio Infiltration Infiltration
Pond, Dpond Gradient, i Rate, f of Pond Pond
Dwt Kequiv Apond Rate, fcorr

Equation 4-15 Equation 4-17


Determined by Determined by Determined by converts in/hr
Varies 1' to 6' Equation 4-14 (1.0 max Equation 4-16 (1.4 max See Table 4-9 Equation 4-18
Lab Tests Lab Tests designer to cfs
value) value)
(ft) (ft) (in/hr) (Acres) (in/hr) (ft) (ft) (in/hr) (cfs)
0
1 9 42 0.03 0.05 1.00 1.95 158 18 1.16 0.9 2.02 0.135
2 9 42 0.07 0.05 1.00 2.14 166 26 1.11 0.9 2.13 0.215
3 9 42 0.10 0.06 1.00 2.33 174 34 1.08 0.9 2.27 0.314
4 9 42 0.14 0.06 1.00 2.53 182 42 1.07 0.9 2.43 0.433
5 9 42 0.18 0.06 1.00 2.72 190 50 1.06 0.9 2.59 0.573
Pond Volume

Calculated (or
from CAiCE)
(ft^3)

2172
5752
10868
17648
26220
Infiltration Trenches

Depth to Hydraulic Infiltration Adjusted


Depth of Hydraulic
Water Table, Conductivity, Rate, CFsilt/bio Infiltration
Trench, Dtrench Gradient, i
Dwt Kequiv f Rate, fcorr
Determined by Determined by
Varies 1' to 6' Equation 4-20 Equation 4-16 See Table 4-9 Equation 4-21
Lab Tests Lab Tests
(ft) (ft) (ft/day) (in/hr) (in/hr)

INPUT VALUES
0 50 102.86 0.51 26.1505 0.8 20.9204
1 60 105 0.62 32.5338 0.8 26.0271

EQUATIONS
D wt + Dtrench where:
Eq. 4-20 gradient = i K = saturated hydraulic conductivity, in feet/day
78( K 0 .05 ) Dwt = depth from the base of the infiltration trench to the water table or to the
first low-permeability layer, in feet
Dtrench = depth of water in the trench, in feet

where:
Eq. 4-16 f =0.5 Ki f = specific discharge or infiltration rate of water through a unit cross-section of the
infiltration facility
K = hydraulic conductivity
i =gradient for ponds and trenches at sites with shallow water tables, or a value of
approximately 1 for ponds and trenches at sites with deep water tables

Eq. 4-21 f corr =(CF silt/bio )f where:


CFsilt/bio = correction factor for siltation and biofouling
f = uncorrected infiltration rate