You are on page 1of 4

Specifications

Item CX41 System Microscope


Optical system UIS2 (Universal Infinity-corrected) optical system
Illumination Built-in transmitted Koehler illuminator
6 V 30 W halogen bulb
100120 V/220240 Vg 0.85/0.45 A 50/60 Hz
CX41
Focusing Stage height movement by roller guide (rack & pinion) Stroke per rotation: 36.8 mm CX2 Series
Full stroke range: 25 mm Upper limit stopper Tension adjustment on coarse focus adjustment knob
Revolving nosepiece Fixed quintuple nosepiece with inward tilt
Observation tube Type U-CBI30-2, Binocular U-CTR30-2, Trinocular U-CTBI, Tilting binocular
Field number 20 20 18
Tube inclination 30 30 3060
Interpupillary distance adjustment range
Light path selector
4875 mm
None
4875 mm
None (Bi 50%, Video/Photo 50% fixed)
4875 mm
None
Optics and Performance Outstanding in its Class
Stage Size 188(W) x 134(D) mm
Movement range 76 mm X-direction x 50 mm Y-direction
Specimen holder Double slide holder
Rubber grip Equipped as standard
Condenser Type Abbe condenser
(CH3-CD)
NA 1.25 with oil immersion
Aperture iris diaphragm Built-in
Dimensions & weight 233 (W) x 432 (H) x 367.5 (D) mm, approximately 8.5 kg (approximately 18.7 lb.)

Dimensions (Unit: mm) Objectives, Plan Achromat


PLCN Numerical Aperture Working Distance
(NA) (W.D.)
4 0.10 18.5 mm
10 0.25 10.6 mm
20 0.4 1.2 mm
40 0.65 0.6 mm
60 0.8 0.2 mm
100O 1.25 0.13 mm
423

*420

100OI 1.250.6 0.13 mm


327
212

Eyepiece
Field Number (FN)
WHB10 20

160 245
233

* The length marked with an asterisk (*) may vary according to interpupillary distance. Distance for figure shown is 62 mm.

OLYMPUS CORPORATION is ISO14001 certified.


OLYMPUS CORPORATION is FM553994/ISO9001 certified.
Illumination devices for microscope have suggested lifetimes.
Periodic inspections are required. Please visit our web site for details.
All the company and product names are registered trademarks and/or trademarks of their respective
owners.
Specifications and appearances are subject to change without any notice or obligation on the part of
CX41 is the environmental conscious product according to OLYMPUS' own standards. the manufacturer.

Printed in Japan M183E-112011


Advanced optical and system performance
with excellent cost-efficiency
The evolution of this bestselling microscope delivers new,
cost-efficient improvements in both optics and system performance.
Newly equipped with Olympus' leading-edge UIS2 optical system,
it provides significantly enhanced image clarity in a variety of
observation methods, from brightfield to reflected light fluorescence.
For all inspection and training applications in the fields of biology
and medicine, the CX41 sets the pace for its class in both
basic and system performance.

Outstanding flat images from PLCN objectives


The CX41 provides images of outstanding brightness and clarity in a variety of observation
modes. As well as Olympus' renowned UIS2 optics infinity system, it employs the PLCN
series of Plan Achromat objectives, which are made from carefully selected top quality glass
and manufactured with the most rigorous precision. The result is a major improvement in
image flatness, with the 10x and 40x objectives in particular providing images that are among
the very best in this class of microscope. Transmitted light illumination is from a 6 V, 30 W
high-intensity halogen light source.

Flatness area comparison


10x 40x
FN 20 FN 20

Conventional Conventional
objective objective
PLCN10 PLCN40

1
Excellent cost-performance in reflected light fluorescence Dependable basic performance assures
and other observation methods outstanding operational convenience

Move the specimen with just one finger Tilting binocular tube / U-CTBI
Rubber grips are provided for the stage The tilting binocular tube lets each operator
handles, allowing the specimen to be moved select the most suitable and comfortable
smoothly with just one finger. The slim body eyepoint a valuable contribution to
and conveniently positioned controls ensure reducing fatigue in extended observation
that everything is within easy reach, so sessions.
operators can maintain a natural posture.

Simple phase contrast attachment /


CX-PH1, 2, 3
For phase contrast observations at 10x,
40x and 100x.

Slide condenser / CX-SLC Inward-facing quintuple revolving Rackless stage with enhanced
Brightfield condenser / CH3-CD Darkfield central stop / CH2-DS
For darkfield observations from 4x to 40x. nosepiece operability
These Abbe type condensers allow The quintuple revolving nosepiece enables a To keep the work area clear, and to avoid
* Separate filter holder (CH2-FH) or attachment lens (CX-AL)
brightfield observations from 4x to required. wide range of magnification observations interference with observation operations,
100x. Accurate centering is provided by and various combinations of objectives. the X-direction travel guide does not extend
the attachment lens (CX-AL) and the iris Unrestricted access to the space in front of out from the side of the stage. The main
diaphragm, to exclude unnecessary the objective allows specimens to be and sub-scale displays are designed for
light and obtain bright Koehler exchanged quickly and easily. easy read-out.
illumination right across the
magnification range. These highly
economical condensers enable phase
contrast and darkfield observations by
simply adding basic accessories.
Low magnification adapter /CX-LA
Use of the 2x low magnification objective allows
macro observation.

Reflected light fluorescence Simple polarizing condenser / Phase-contrast condenser / CX-PCD


attachment / CX-RFA-2 CH3-CDP The multi-purpose CX-PCD condenser
Users can choose between blue or green With the optional plate adapter U-TAD, allows observation of brightfield, phase-
excitation and transmitted light polarizing observations from 4x to 100x contrast and darkfield images without
observations. UIS2 optics provide bright using a tint plate can be performed. exchanging condensers. Phase-contrast
fluorescence images, with no intermediate A U-GAN analyzer is provided for gout observation from Torque adjustable focusing knob Easy transportation and installation
magnifications when changing from inspection. Polarizing objectives from 10x to 100x and The torque of the coarse focusing knob can The CX41 is eminently portable, with
transmitted light to fluorescence 4x to 100x are darkfield be adjusted, to suit different operators' needs convenient handgrips at the front and back
observation. Standard PLCN objectives can available. observation from and to make focusing smooth and easy while of the frame and no inconvenient protrusion
be used without replacement. * Separate polarizer 10x to 40x is keeping the hands on the desk. A stage of the stage guide.
U-POT and analyzer allowed. upper limit stopper is also provided.
U-ANT required.

Dry darkfield condenser / CX-DCD


This dry-type darkfield condenser gives a
superior darkfield effect without the need for
immersion in oil. Anti-fungus treatment
Suitable for use The treatment applied to the
at 10x and 40x observation tubes, eyepieces and
magnifications. objectives, protects quality of optical
parts even in high humidity regions.

3 4
More accessories, more observation versatility

CX41 SYSTEM DIAGRAM


CAMERA SYSTEM/
MICROSCOPE DIGITAL CAMERA

Eyepoint adjuster/ U-EPA2 CAMERA ADAPTER*1*2


Allows the eyepoint position to be raised by
30 mm. Up to two eyepoint adjusters can WHB10
be attached between the frame arm and WHB10 WHB10-H
observation tube. WHB10-H Eyepieces
Eyepieces U-CTBI*3
Economical tilting
binocular tube

U-CBI30-2 U-CTR30-2
Binocular tube Trinocular tube

Dual observation attachment/ U-DO3


Enables dual, simultaneous observation of
a single specimen from the same direction U-GAN U-TRU
Gout analyzer
with equal magnification and brightness for Arrow pointer/ U-APT
Trinocular intermediate attachment
both operators. A pointer can be used to Enables insertion of an LED arrow for
indicate specific sections of the specimen to display in a digital image. U-ANT
simplify the training process and enhance Analyzer
for transmitted CX-DMB-2
discussion. light Mirror unit for fluorescence, B excitation
U-TP530
Tint plate CX-DMG-2
Mirror unit for fluorescence, G excitation
U-TAD
Plate adapter
U-TP137
1/4 wavelength plate Filter

PLCN Objectives
Other UIS2 Objectives
2x magnification changer/ U-ECA
Magnification is doubled by engaging the CX-RFA-2
auxiliary 2x lens. Reflected light U-LH50HG U-RFLT50
fluorescence attachment Lamp house for Power unit
50 W Hg
CX-PCD
Phase contrast
condenser
U-DO3
Trinocular tube/ U-CTR30-2 Dual observation attachment

Digital or video cameras can be attached for


on-site/ remote illustration of educational/
discussion meetings. CX-PH1, 2, 3 CX-DCD U-DAL10
Simple Dry darkfield Drawing attachment 10x
Drawing attachment/ U-DA phase-contrast condenser U-DA
Digital camera/ DP21 attachment
High-definition images displayed with The drawing attachment projects an image Drawing attachment

stunning detail in real time. Seamless of the pencil and drawing surface into the
conference support with real-time visual field.
U-EPA2
image display and smooth operation. CH2-FH CH3-CDP Eyepoint adjuster
Filter holder Simple
polarizing
U-DA condenser

U-ECA
Magnification changer 2x
U-DAL10
CX-AL CH3-CD
Attachment Brightfield
lens condenser
Trinocular intermediate attachment/
U-TRU U-APT
A binocular tube on its own allows digital Arrow pointer
imaging in combination with this trinocular CX-LA CX-SLC
Low magnification Slide condenser
intermediate attachment. adapter

U-POT CH3-CH
32.5 filter
Polarizer CX41RF/CX41LF Cord rest
Microscope frame
CH2-DS Rubber grip
45 filter
Darkfield central stop (standard equipment
of the microscope frame)

*1 Please consult your Olympus dealer for detail. *2 U-TV1 cannot be attached for technical reason. Combine U-TV1-2 for 1x adapter. *3 10x eyepieces incorporated. FN 18
CX41+DP21
5 6

You might also like