You are on page 1of 9

[Company logo here]

Fluid Flow Simulation Project


[company name here] [city, state here] [company url here] Report

[name] [title] [email address] (###) ###-####

SOLIDWORKS Flow Simulation


Project Report

July 19, 2017

[Model Picture here]

Learn more about SOLIDWORKS Flow Simulation


Fluid Flow Simulation Report

Table of Contents
1 General Information.................................................................................................1
1.1 Analysis Environment................................................................................1
1.2 Model Information.....................................................................................1
1.3 Project Comments:R123 T = 300K............................................................1
1.4 Size of Computational Domain..................................................................1
1.5 Simulation Parameters..............................................................................1
1.5.1 Mesh Settings.........................................................................................1
1.5.2 Material Settings....................................................................................2
1.5.3 Initial Conditions....................................................................................2
1.5.4 Boundary Conditions..............................................................................2
1.5.5 Volumetric Heat Sources........................................................................2
1.5.6 Engineering Goals..................................................................................2
1.6 Analysis Time............................................................................................2
2 Results...............................................................................................................2
2.1 Analysis Goals...........................................................................................2
2.2 Global Min-Max-Table...................................................................................2
2.3 Results......................................................................................................2
2.4 Conclusion.................................................................................................2
3 Appendix.............................................................................................................2
3.1 Material Data............................................................................................2

2
Fluid Flow Simulation Report

1 General Information
Objective of the simulation: Analizar el perfl de velocidades del fluido refrigerante R123 a lo largo de un tubo de
diametro 0.01m y una longitud de 1,5m.

1.1 Analysis Environment


Software Product: Flow Simulation 2015 SP3.0. Build: 3058
CPU Type: Intel(R) Celeron(R) CPU N3050 @ 1.60GHz
CPU Speed: 1601 MHz
RAM: 4008 MB / 134217727 MB
Operating System: (Build 9600)

1.2 Model Information


Model Name: REFRIGERANTE 123.SLDPRT
Project Name: perfil de velocidades

1.3 Project Comments: R123 T = 300K


Unit System: SI (m-kg-s)
Analysis Type: Internal

1.4 Size of Computational Domain

Size
X min -0.002 m
X max 1.502 m
Y min -0.010 m
Y max 0.010 m
Z min -0.010 m
Z max 0.010 m

1.5 Simulation Parameters


1.5.1 Mesh Settings
1.5.1.1 Basic Mesh

Basic Mesh Dimensions


Number of cells in X 178
Number of cells in Y 2
Number of cells in Z 2

1.5.1.2 Analysis Mesh


Total Cell count: 35600
Fluid Cells: 12776
Solid Cells: 2848
Partial Cells: 19976
Trimmed Cells: 0
Fluid Flow Simulation Report

1.5.1.3 Additional Physical Calculation Options


Heat Transfer Analysis: Heat conduction in solids: Off
Flow Type: Laminar and turbulent
Time-Dependent Analysis: Off
Gravity: Off
Radiation:
Humidity:
Default Wall Roughness: 0 micrometer

1.5.2 Material Settings

Material Settings
Fluids
R123

1.5.3 Initial Conditions

Initial Conditions
Thermodynamic parameters Static Pressure: 101325.00 Pa
Temperature: 300.00 K
Velocity parameters Velocity vector
Velocity in X direction: 0 m/s
Velocity in Y direction: 0 m/s
Velocity in Z direction: 0 m/s
Turbulence parameters

1.5.4 Boundary Conditions

Boundary Conditions
Inlet Velocity 1
Type Inlet Velocity
Faces Face<1>@Saliente-Extruir1
Coordinate system Face Coordinate System
Reference axis X
Flow parameters Flow vectors direction: Normal to
face
Velocity normal to face: 0.068 m/s
Fully developed flow: No
Thermodynamic parameters Temperature: 300.00 K
Turbulence parameters Boundary layer parameters
Boundary layer type: Turbulent

Environment Pressure 1
Type Environment Pressure
Faces Face<2>@Saliente-Extruir1
Coordinate system Face Coordinate System
Reference axis X
Fluid Flow Simulation Report
Thermodynamic parameters Environment pressure: 101325.00 Pa
Temperature: 300.00 K
Turbulence parameters Boundary layer parameters
Boundary layer type: Turbulent

1.5.5 Volumetric Heat Sources

1.5.6 Engineering Goals

1.6 Analysis Time


Calculation Time: 328 s
Number of Iterations: 66
Warnings:
Fluid Flow Simulation Report

2 Results
2.1 Analysis Goals

Goals
Name Unit Value Progress Use in Delta Criteria
converge
nce

2.2 Global Min-Max-Table

Min/Max Table
Name Minimum Maximum
Pressure [Pa] 101325.00 101335.22
Temperature [K] 300.00 300.00
Density (Fluid) 1456.69 1456.69
[kg/m^3]
Velocity [m/s] 0 0.085
Velocity (X) [m/s] 0 0.085
Velocity (Y) [m/s] -4.302e-004 4.300e-004
Velocity (Z) [m/s] -4.312e-004 4.287e-004
Temperature (Fluid) [K] 300.00 300.00
Vorticity [1/s] 6.31e-003 21.25
Velocity RRF [m/s] 0 0.085
Velocity RRF (X) [m/s] 0 0.085
Velocity RRF (Y) [m/s] -4.302e-004 4.300e-004
Velocity RRF (Z) [m/s] -4.312e-004 4.287e-004
Shear Stress [Pa] 0.02 0.09
Relative Pressure [Pa] -3.34e-005 10.22
Heat Transfer 0 0
Coefficient [W/m^2/K]
Surface Heat Flux 0 0
[W/m^2]

2.3 Results
Fluid Flow Simulation Report

REFRIGERANTE 123.SLDPRT [perfil de velocidades]


0.09

0.08
Croquis3@Line1
Croquis3@Line2
0.07
Croquis3@Line3
Croquis3@Line4
0.06 Croquis3@Line5
Croquis3@Line6
0.05
Velocity (X) [m/s]

Croquis3@Line7
Croquis3@Line8
0.04 Croquis3@Line9
Croquis3@Line10
0.03 Croquis3@Line11
Croquis3@Line12
0.02 Croquis3@Line13
Croquis3@Line14
0.01 Croquis3@Line15
Croquis3@Line16
0
0 0.01 0.01 0.02 0.02 0.03
-0.01

Length [m]

2.4 Conclusion

Se logr obtener el perfil de velocidades a lo largo del tubo considerando como fluido el refrigerante del tipo R123 con
condiciones de frontera correspondientes a la temperature de 300K.
Fluid Flow Simulation Report

3 Appendix
3.1 Material Data

Engineering Database
Liquids
R123
Path: Liquids Pre-Defined
Density
Density[kg/m^3]

Temperature[K]

Dynamic viscosity
Dynamic viscosity[Pa*s]

Temperature[K]
Fluid Flow Simulation Report
Specific heat (Cp)
Specific heat (Cp)[J/(kg*K)]

Temperature[K]

Thermal conductivity
Thermal conductvity[W/(m*K)]

Temperature[K]

Cavitation effect: No