You are on page 1of 2

PHASED ARRAY INSPECTION PRELIMANARY REPORT

Procedure No.: GSOP 2014 Revision 00


Client KNPC-MAB Report No. Stork/AUT/004/2017

Unit Unit-20 Date 17-04-2017

VESSEL No. 202 PA Equipment TD-HANDY(RX-0121)

Services COCKE DRUM Scanned Length 23.2 Meter

NOM. THICK. 27 MM+ 3.2 MM Material A-387 GR II

Probe Dia & Frequency : Phased Array 5L32 A11 (5 MHz)

Cable Length & Type : 2.5 mtr. D78 Connector

Couplant : Water + Wall Paper paste

Type of scanning : Manual Contact Method sectorial scan (40


degree to 70 degree)

Phased Array Sensitivity : Dia 1.5 mm SDH at 62mm Depth

Scanning Sensitivity : Ref. dB + 6 dB

Scanning details and Results:


PAUT Weld scanning was carried out for seam C-1 of Vessel-202.

Due to support welded over the seam, 1 meter length on 0 degree & 180 degree each
was not accessible for scanning.

No recordable indication observed for seam C-1.


Tested By Approved By

Name Vikas Chandra ( PAUT & TOFD Level-II)


Sign

Date 17-04-2017
INDICATION LOCATION LENGTH DEPTH THROUGH TYPE
HEIGHT
1 0+3590 25MM 26 MM 4MM LINEAR
2 90+2258 88MM 27 MM 3MM LINEAR
3 180+3760 25MM 25 MM 4MM LINEAR
4 270+350 100MM 25MM <2MM LINEAR
5 270+5000 250MM 25MM <2MM LINEAR