You are on page 1of 5
CENTRE “MET” PORTABLE "i@ HARDNESS a TESTERS |\oet REFERENCE TEST BLOCKS CP HARDNESS PORTABLE ULTRASONIC HARDNESS TESTER MET-U1A / MET-U1A5\ PORTABLE COMBINED HARDNESS TESTER MET-UDA DISTINCTIVE FEATURES DISTINCTIVE FEATURES MET-U1A consist of an electronic module and an UCI probe U1A with a load of 15 N; NEW! MET-U1A50 consist of an electronic module and an UCI probe U1A50 with a load of 50 N, Hardness testing’ . ~ articles of thickness starting from 1 mm; “articles in hard-to-reach places; + without any visible indent on the surface; = metal coatings; ; . time of one measurement - 1,5 sec; Hardness testing: Troughnoss of the tested surface for MET-U1A = the use of two changeable probes: ultrasonic and hardness tester -2.5 Ra dynamic two hardness testers combined in one device; roughness of the tested Surface for MET-U1A50 ~ articles of different weight, configuration, structure and hardness tester - 3,2 Ra degree of mechanical and thermal treatment. Implements ultrasonic contact impedance method (UCI). Implementation of both rebound and ultrasonic contact impedance (UCI) methods PORTABLE DYNAMIC HARDNESS TESTER MET-D1A RANGE AND ERROR OF MEASUREMENTS DISTINCTIVE FEATURES Hardness scale Measurement range Error, not more than] Reproducibility Rockwell'C" scale (20-70) HRC TS HRG O5HRC Rockwell” scale (41-99) HRB 2HRB 1.2 HRB Brine scale (75-650) HB 70 HB 1% Vickers scale (75-1000) HV 12 HV. 1% Shore scale (28-102) HSD. 2HSO THSD Tensile strength, Rm (78-1736) MPa 5% ADVANTAGES OF PORTABLE HARDNESS TESTERS - Exceptional accuracy of measurements provided by the transfer of Rockwell, Brinell, Vickers and Shore hardness values from the primary hardness machine directly to portable hardness testers; - Errorless scale conversion — hardness tester calibration is carried out using only hardness reference test blocks without any conversion tables; - The possibilty of independent hardness tester calibration; - Aluminum body of the electronic module: hermetically sealed, dust- and waterproof (IP 66), thermo resistant; ~ Exclusive in-house software allowing to process measurement data transferred from hardness tester storage to the computer via USB-connection: + Calibration is carried out by "VNIIFTRI’. Hardness testing: - articles weighting more than 3 kg: - materials with non-homogenous, coarse structure, forged and cast articles; - does not depend on the probe special p» high efficiency. Implements a rebound method MINIATURE ULTRASONIC HARDNESS TESTERS RANGE AND ERROR OF MEASUREMENTS Hardness testername | Hardness scale | Measurement range | Error, not more than | Reproducibility iniature Rockwell 'C’ hardness tester Miniature Rockwell 'B' hardness tester MET-HRC /MET-HRC 50 | Rockwell C’ scale (20-70) HRC. 1,5 HRC 0,5 HRC MET-HRB /MET-HRB 50 | Rockwell'B' scale (41-99) HRB 2HRB 4.2 HRB MET-HB /MET-HB50 | Brinelle scale (75-650) HB 10 HB 1% MET-HV/METHV50. | Vickers scale (75-1000) HV 12HV 1% MET-HSD/MET-HSD50 | Shore scale (23-102) HSD 2HSD 1 HSD TECHNICAL CHARACTERISTICS aw 2 a it Mass 250 Indenter diamond Vickers pyramid Time of one measurement 1 sec Applied force 415 N/50N Miniature Brinell hardness tester Miniature Vickers hardness tester Roughness of tested surface 2,5Ra/3,2Ra Radius of curvature of tested not less than 5 mm surfase Width of tested sample not less than 1mm Power supply 1chargeable AAA battery Hardness tester resources 200000 (minimum number of testings) ADVANTAGES OF MINIATURE HARDNESS TESTERS - Hardness control of metal articles more than 1 mm thick; - Easy, compact, comfortable to use. Hardness tester without electronic module, connection cable and keys; - Exceptional accuracy of measurements provided by the transfer of hardness values from the primary hardness machine directly to mini hardness testers through reference hardness test blocks; Firm aluminum body, modem design and well-thought ergonomic characteristics; Hardness control of metal articles of any weight and thickness starting from 1mm by ultrasonic contact ee ee ee tra nn Calbration via USB connection: impedance method (UCI), ~ Gallbration is carried out by The principle of operation is based on the determination of frequency of indenter free oscillation (acoustic resonator with diamond Vickers pyramid) under the constant effort 15N / SON MET-HB / MET-HB 50 REFERENCE HARDNESS TEST BLOCKS REFERENCE HARDNESS TEST BLOCK: WH) _ Rockwell test blocks ™ tarénessrnge | sonaniimiy | toast | Sze, REBT a @ FRG wT 72 720 \ TRG a5s as 750 eont0s19 Shore test blocks FRG rm 750 FRG 258 a4 750 Hess range | Nonuntirmty | S29, nm OT Superficial Rockwell test blocks 106027 a cons 190.957 Hiacressrnge | Nonanitomiy | Lo.tat | 26,0 Tae a = TaN ae aa = TaN 7 20 soaoao HT a8 72 20 RT es 78 20 Her 4950 ss # Micro Vickers test blocks trrnessrnge | Nonanfomty | toad iat | irynen Ts THEO =a wm TaoTmIs | as 3005 07 Brinellitestiblocks ADVANTAGES OF HARDNESS TEST BLOCKS coe oars ime | aoe = Compliance wit intematonal standards ISO, ASTM, GOST; sae zee “minimum dispersion in hardness readings along the surface; = Long-term stability; - Calibration is carried out by "VNIIFTRI" Vickers test blocks vrssscnae | nonentomy | towitot | Sen nm nS AROS = TATE mm | tonse.s0.20 | ooaoeo ae | TH 2005 oar Nina ican aE * vs.n2 | couono HV 200850) CENTRE “MET” DISTRIBUTORS Phase II Plus NORTH AND SOUTH AMERICA Innovatest Europe BV EUROPE Phase II Measuring Instruments (Beijing) CHINA Fuji-Instruments JAPAN An-bomb Instruments TAIWAN Micron Metrology INDIA Halim Instrument Corp. KOREA Teskon Teknik Ekipmanlar TURKEY NTD Instruments SINGAPORE, MALAYSIA, INDONESIA, THAILAND, VIETNAM PHILIPPINES and BANGLADESH +7(495) 229-75-26 www.met-hardness.ru info@met-hardness.ru

You might also like