You are on page 1of 2

"REBARS (318-05).

xls" Program
Version 1.0

REINFORCING BAR DEVELOPMENT AND SPLICE LENGTHS


Per ACI 318-05 Building Code - Chapters 12 and 21
For Low & High Seismic Risk Applications
Job Name: Subject:
Job Number: Originator: Checker:

Input Data:

General Information:
Reinforcing Bar Size = 6 Ldt=25.6''
Reinforcing Yield Strength, fy = 60 ksi
Concrete Comp. Strength, f 'c = 3.0 ksi bc=2''
Lightweight Concrete? No
Epoxy Coated Bars? No >12"
Ratio: As(required)/As(provided) = 1.000
High Seismic Risk (Chapter 21) = No
Ldo=19.7'' bc=2''
For Straight Reinforcing Tension Bars:
Center-to-Center Bar Spacing, bs = 12.000 in. Straight Bar Development
Clear Cover to Face of Bar, bc = 2.000 in.
Transverse Reinforcing Index, Ktr = 0.000 lb./in.

For Straight Reinforcing Compression Bars:


Enclosed with #4 Ties @ <= 4"? No Lat=25.6''
Lbt=33.3''
For Standard Hooks in Tension:
Side Cover to Face of Bar, sc = 2.500 in. bc=2''
Clear Cover to Bar Hook, hc = 2.000 in.
Enclosed with Ties @ <= 3*db? No >12"

Results: Lao=19.7''
Lbo=25.6''
Reinforcing Bar Diameter, db = 0.750 in. Straight Bar Splices

For Straight Reinforcing Tension Bars:


Top Bar Development, Ldt = 25.6 in.
Other Bar Development, Ldo = 19.7 in.
Top Bar Class "A" Splice, Lat = 25.6 in.
Other Bar Class "A" Splice, Lao = 19.7 in. Ldh=11.5'' hc=2''
Top Bar Class "B" Splice, Lbt = 33.3 in.
Other Bar Class "B" Splice, Lbo = 25.6 in. sc=2.5''

For Straight Reinforcing Compression Bars: Lh=12''


Development Length, Ldc = 16.4 in.
Splice Length = 22.5 in.
D=4.5''
For Standard Hook Tension Bars:
Development Length, Ldh = 11.5 in. Standard Hook Development
Standard Hook Leg Length, Lh = 12.0 in.

1 of 2 7/22/2017 12:39 AM
"REBARS (318-05).xls" Program
Version 1.0

Tabulation of Calculated Results for All Bar Sizes Based on Specific Input:

Reinforcing Bar Development and Splice Lengths for f 'c = 3,000 psi and fy = 60 ksi
Tension Development Class "B" Splice Std. 90 deg. Hook Compression Bars
Top Bar Other Bar Top Bar Other Bar Embed. Leg Length Develop.
Bar Size Splice
Ldt Ldo Lbt Lbo Ldh Lh Ldc
(in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.)
#3 12.8 12.0 16.7 15.6 6.0 6.0 8.2 12.0
#4 17.1 13.1 22.2 17.1 7.7 8.0 11.0 15.0
#5 21.4 16.4 27.8 21.4 9.6 10.0 13.7 18.8
#6 25.6 19.7 33.3 25.6 11.5 12.0 16.4 22.5
#7 37.4 28.8 48.6 37.4 13.4 14.0 19.2 26.3
#8 42.7 32.9 55.5 42.7 15.3 16.0 21.9 30.0
#9 53.0 40.8 68.9 53.0 17.3 19.0 24.7 33.8
#10 65.4 50.3 85.0 65.4 19.5 22.0 27.8 38.1
#11 78.5 60.4 102.0 78.5 21.6 24.0 30.9 42.3
#14 107.5 82.7 --- --- 37.1 31.0 37.1 ---
#18 173.9 133.8 --- --- 49.4 41.0 49.4 ---
Notes:
1. Straight development and Class "B" splice lengths shown in above table are
based on uncoated bars assuming center-to-center bar spacing = 12" without
ties or stirrups and bar clear cover = 2".
Normal weight concrete with no transverse reinforcing are both assumed.
No excess reinforcing is assumed.
2. Standard 90 deg. hook embedment lengths are based on bar side cover = 2.5"
and bar end cover = 2" without ties around hook.
3. Table does not reflect special seismic considerations from ACI 318-05, Chapter 21.

2 of 2 7/22/2017 12:39 AM