DISOMAT Opus Weight Indicators

 Legal for trade weighing indicator for a


wide variety of applications

 Clear text operator guidance on back


lighting LCD display

 Stainless steel - at a high protection class


for table-top and wall mounting.

 Top-hat rail design

 Built-in legal-for trade memory (optional)

 Fieldbus-compatible

 Ethernet interface, can also be used for


configuration

 USB cable for optional /n PC keyboard

 All components can be exchanged without


re-verification

Application Equipment
Beyond that, there is the
The DISOMAT Opus weighing indicator DISOMAT Opus is available in three
is perfectly suited to all applications versions:  VEG 20700 design for top-hat rail
where weights are recorded, displayed assembly in the control cabinet
and printed legal-for-trade. Results can  The basic DISOMAT Opus mini also legal for trade and including a
be transferred to master systems for VKG 20710 has a serial interface display.
further processing. and an analog output
 The expanded DISOMAT Opus This instrument also has extensive
DISOMAT Opus is also excellently suited maxi design, VKG 20700 also has standard interface equipment that makes
to simple control jobs in process  More serial interfaces it suitable both for control and
applications with its complete equipment  Binary I/O communication applications.
of interfaces.  A wide range of communication
options. All instruments including those with a
This indicator fits easily into data
keyboard can be conveniently
processing and control systems with its
Both indicators have a standard stainless configured and calibrated via the
extensive communication options,
steel console shaped case in protection DISOPLAN PC program.
regardless of whether it's PLC or PC.
class IP65 that is suited for table-top and
wall mounting (cable outlet downward Since Ethernet is increasingly becoming
Some typical applications are:
with wall mounting). the communication standard even in
- Platform scales without major
industry, Opus maxi and the top-hat rail
control jobs
unit have a standard equipment 100
- Bin weighers (fill level control and fill These indicators have an easily readable
back lighting LCD display for showing MBaud network connection
or discharge weighing)
- Simple road weigh bridges and weight with clear text operator guidance.
Data is keyed in via flexible membrane The following options are available
crane scales  Legal for trade data memory
- Applications as weight transducers keyboard with 9 or 21 keys.
 Remote PC keyboard (only with the
for PC-based weighing and data Opus maxi)
processing systems (such as truck  Fieldbus cards to communicate via
scales). Profibus DP-V0 or DeviceNet.

BV-D 2236GB
105
Communication Print-out
With as many as three serial DISOPLAN also allows: Variable print pattern formatting
interfaces, DISOMAT Opus is allows you to freely lay out your
excellently equipped for exchanging  setting all instrument parameters weighing report. You can e.g. print out
data with its environment.  calibrating the instrument the following along with the weight
For example,  conveniently configuring the print data:
- Printer pattern
- large display  read-out and display of weight  The date and time
- Data processing signals  Serial no.
can be connected at the same time.  reading out the complete
Two of the interfaces are designed instrument configuration (backup)  Balance totals
as RS 232. The third  restoring stored data into a  The number of balanced
(RS 485 2/4 wire) is especially DISOMAT. This means a weighings
suited to communication on the bus substitute can be prepared at  5 strings with as many as 25
and at greater distances. short notice. digits
 3 stored texts with 26 characters
The Ethernet connector (10/100 All parameter and calibration data are each.
MBaud) is operated in the control stored power failure safe in the You can conveniently format the print-
systems via the MODBUS/TCP instrument. The real-time clock runs out in the DISOPLAN program. The
protocol. Another alternative is at least 7 days without a power user arranges all of the printing
calling up HTML pages stored in the supply. elements the way they should appear
instrument via a standard web
on the print-out later. You no longer
browser. The instrument can also be Functions have to spend a lot of time keying in
configured via the Ethernet Beyond the basic scale functions such control sequences and the like.
connector. as
- Acquire and clear tare Legal-for trade memory
Beyond this, the standard fieldbus - Zero positions The additional built-in legal-for-trade
system - Print memory releases the user from the
- Profibus DP-V0 and DISOMAT Opus can also carry out a necessity of creating and archiving
- DeviceNet series of other functionalities. To use legal for trade vouchers on paper.
can be connected via matching them, one of the 'function variants in
optional coupling modules. the instrument is activated. This puts
DISOMAT into a configuration for Equipment
Parallel signal interchange specific applications that both In spite of its low price, DISOMAT
For control jobs, DISOMAT Opus allocates the essential actions to the Opus has enormous processing
has the following parallel inputs and six function keys and assigns the performance. The 32-bit ARM
outputs (except Opus mini): inputs and outputs of the instrument controller also has sufficient power
- 4 optocoupler inputs 24 Volt to the matching signals. reserves for fast weighing processes,
- 2 NAMUR inputs (for instance, for The following function variants can be simultaneous operation of various
proximity switches) activated: interfaces and also for future
- 4 relay outputs, suited for 230 applicatio
VAC to switch a traffic light ns.
- an additional 24 V optocoupler
output for quicker signals.

Beyond this, all instruments


(including the mini) have a 12-bit
analog output that can transfer
weight or material flow to a PLC or
display.

Operation and Settings


Standard DISOMAT operation is in
German and English. All operator
guidance is carried out and data is
entered in clear text

You can easily load other operating


languages into the instrument via
the PC-assisted DISOPLAN
configuration program (WINDOWS  Cargo scale (weighing / printing /
program) (Italian, French, Dutch, balancing)
Polish, Slovakian; Slovenian;  Filling scale (one-component
Spanish, Czech, Hungarian and feeding)
Russian are presently available.  Discharge scale (one-component
Other languages are available at feeding)
request).  Crane Scale.

106
Our dongle strategy
Our proven strategy of the the scale is correctly configured with as many as 3 x 4,000 digits.
intelligent load cell plug (dongle) is and calibrated again. This means Together with the maximum
also used in DISOMAT Opus: all of that even legal for trade scales do resolution of 0.6PV/increment
the scale's relevant setting and not have to be recalibrated or re- value, this instrument is well
calibration data are stored in the verified. equipped for sophisticated jobs
dongle. Since all of our instruments such as with a high preload.
are calibrated at the factory for Pattern approval
identical sensitivity, you can DISOMAT Opus is approved for
interchange the electronic non-automatic scales (throughout
equipment at any time if there is a the European Union), with a
defect. After attaching the dongle, maximum of 6,000 digits or as a
multi-range / multi-interval scale

The dimensioned drawing of DISOMAT Opus VKG

The dimensioned drawing of DISOMAT Opus VEG

107
Technical Data:

Display LCD back lighting. 1 row 20 characters. Serial interfaces: 3 interfaces for the printer, data processing
Characters 12 mm high or secondary display
Keyboard Flexible membrane keyboard. Interface 1: RS 232
Opus maxi, VKG 20700: 21 keys Interface 2: RS 232 *
Opus mini, VKG 20710 : 9 keys Interface 3: 485, 2/4 wire; *
VEG 20700 top-hat rail module: no Max. Baud rate: 38400
keyboard Data processing Siemens 3964R
Supply voltage for VKG 85-250 VAC, 50-60Hz, procedures S5 (RK512)
20700/710 desk- max. 10 VA Schenck standard procedure DDP8672
top/wall units Schenck poll procedure DDP8785
MODBUS
Supply voltage for VEG 18 36 VDC
Secondary display DTA
20700 top-hat rail unit
procedures: DDP 8861
DDP 8850
Temperature range Service temperature: -30 to +60C Ethernet interface * 10/100MBaud, on board
(legal for trade: -20 to +40 C) USB interface * On board, for PC keyboard
Storage temperature: -40 to +80 C Fieldbus (optional) Profibus DP-V0
Measuring channels 1 DeviceNet
Load cell supply: 5V alternating current supply Other options PC keyboard (USB) *
Input signal 0 to 15 mV Legal-for trade memory
Sensitivity 0,6 V/d *: Only VKG 20700 (Opus maxi) and VEG 20700.
Unit kg, g, t, lb; N; kN
Increment value 1, 2 and 5, etc. adjustable from 0.01 -
5000 Equipment supplied:
Number of digits Legal-for-trade operation: max. 6000 d V040000.B01 DISOMAT Opus Maxi, VKG 20700.
Multi-range scale 3 x 4000 d Stainless steel instrument IP65
Multi-interval scale 3 x 4000 d V040001.B01 DISOMAT Opus Mini, VKG 20710.
No limitation to resolution in non legal-for- stainless steel instrument IP65
trade operation
Taring To 100% of the weighing range V040002.B01 DISOMAT Opus top-hat rail unit
Zero setting device Can be set max. 20% V040030.B01 Interface module Profibus, VPB 020
Automatic zero tracking 0.5d/sec, can be V040031.B01 DeviceNet connecting assembly,
selected; automatic zero setting can be VCB 020
selected
V040045.B01 Remote PC keyboard (USB), German
Load cell impedance: Min. 47 (equalling 8 x 350 load cell
key assignment
or > 20 RT load cells @ 4000 )
Date/Time Real-time clock (RTC), V040045.B02 Remote PC keyboard (USB), English key
Back-up time at least 7 days assignment
Housing (VKG model) Stainless steel 1.4301; V029352.B01 Legal-for-trade memory VMM 20490
Protection class IP 65, suitable for desk-
top and wall mounting
Binary inputs* 4 x optocoupler, 18 - 36 VDC, type 5 mA
2 x NAMUR, max. 8V
Binary outputs* 4 x relay, 230 VAC, 60 W max.
1 x optocoupler, 18 - 36 VDC,
max. 50 mA
Analog output 1 x 0(4) 20mA, 12 Bit, max. load 500

108