You are on page 1of 2

Installation and Maintenance Instructions for

ASHCROFT P-Series Snap Action


Switches for Pressure Control

psi Ranges H2O Ranges


4. 70 4. 70
(119 ) (119 )
5 0. 0 3. 90 5.00 3 9. 0
(12 )7 (99) (127) (9 9 )
3/4 NPT 3/4 NPT
TYP TYP

2.90 2. 9 0
1.06 (7 4 ) (74 )
1.06
(27) (27)
8.0 8
(205 ) 7.7 2
(19 6)
8. 3 6
2.30 2.30 (212 )
(58) 3.06 (58) 3. 06
(7 8 ) (78)
0 3. 1X 4 HOLES 0.3 1X 4 HOLES
(8) (8)

0.38
(10)
0.38
(10)
3.88 1/4 NPT PORT
(99) 3.88 5 12
.
1/2 NPT MALE & (99) (13 0) 1/4 NPT PORT
4.75 1/4 NPT FEMALE
(121) 4.75 5. 32
(121) (13 5 )
5.50
(140) 5.50
(140)

N4 5.0 lb. (2.3) N4 5.7 lb. (2.6)


N7 5.6 lb. (2.5) N7 6.3 lb. (2.9)

STANDARD RANGES STANDARD RANGES


15, 30, 60, 100, 200, 400, 600 psi 30, 60, 100, 150 H2O
1000, 2000, 3000 psi
30Hg vac.-0 psi
30Hg vac.-15 psi 70A1883 P-Series - H2O

70A1886 - P-Series Vac-600psi

INTRODUCTION ing control to pressure line, always use the wrench flats or hex
The Ashcroft pressure control is a precision device which fea- on the pressure connection. Never tighten by twisting the case.
tures a snap action switch. Fixed deadband is available with
single or dual SPDT independently adjustable switches with ELECTRICAL CONNECTION
various electrical ratings. Adjustable deadband is available with Remove top cover, cover unscrews (CCW).
a SPDT switch with various electrical ratings. Several wetted On all units except one with terminal blocks-wire directly to the
material constructions for compatibility with pressure media may switch according to circuit requirements. Units with terminal
be obtained. blocks-wire directly to terminal blocks as required. Terminals are
The P Series Ashcroft snap action pressure switch is available marked common, norm open and norm closed.
in both standard NEMA~ and explosion-proof NEMA 7 & 9 con-
figurations. The enclosure is an epoxy coated aluminum casting.
TERMINAL BLOCK
SWITCH A
INSTALLATION
3

This control is a precision instrument and should never be left 2 TERMINAL BLOCK
with internal components exposed. During installation insure that
1

SWITCH B
1

covers are in place and conduit openings are sealed. 2


C
3

MOUNTING NO
Four holes in the bracket supplied are used in surface mounting NC
of the control. Location of these holes is shown on the general NC
dimension drawings. An optional pipe mounting bracket is also NO
available. Mount on a vibration free surface or pipe. When tighten- C

2007 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614-5145, USA, Tel: 203-378-8281, Fax: 203-385-0499, www.ashcroft.com
All sales subject to standard terms and conditions of sale. I&M009-10013G-10/00 (250-2524) AMR 12/07
Installation and Maintenance Instructions for
ASHCROFT P-Series Snap Action
Switches for Pressure Control

Series PP-D Dual Switch Remove front cover, held in place


CONDUIT CONNECTIONS by two screws. There are two range adjusting wheels. The
Two 34 NPT holes are provided, one fitted with a plug, the other adjusting wheel on the left (labeled A) controls the left switch,
with a cap. It is recommended that Teflon tape or other sealant the adjusting wheel on the right (labeled B) controls the right
be used on conduit bushing or plug threads to ensure integrity switch. The switches are set independently.
of the enclosure. NEMA 7 & 9 enclosures require proper conduit
seals and breathers as per the National Electrical Code. NOTE: The units are calibrated at the factory such that for proper
operation switch B setpoint must be set higher than
SETPOINT ADJUSTMENTS switch A setpoint.
Series PP-S Single Switch Remove front cover, held in place
by two screws. For setpoint adjustment to within + 1% of nomi- For setpoint adjustment to within 1% of nominal range mount
nal range, use a suitable reference such as an Ashcroft the switch on a calibration stand, and use a suitable reference
Duragauge or test gauge. Monitor switch with a suitable pilot such as an Ashcroft Duragauge or test gauge. Monitor switch
light or meter. Pressurize the system to the required setpoint with a suitable pilot light or meter.
and turn the adjusting wheel until the switch changes mode. Pressurize the system to the required setpoint and turn the
When the setpoint has been achieved, raise and lower the pres- adjusting wheel until the switch changes mode. When the set-
sure to insure that the setpoint is correct. point has been achieved, raise and lower the pressure to insure
that the setpoint is correct. This must be done for both setpoint
0 0 A and setpoint B.

20 20 Series PP-A Adjustable Deadband SwItch Remove front


cover, held in place by two screws. The adjusting wheel labeled
40 40 A controls the resetpoint of the switch. The adjusting wheel
labeled B controls the setpoint of the switch.
60 60
Note: The units are calibrated at the factory such that for proper
operation setpoint B is always higher than resetpoint A.

For accurate setpoint adjustment, mount the switch on a calibra-


tion stand, and use a suitable reference such as an Ashcroft
A B Duragauge or Test Gauge. Monitor switch with a suitable pilot
light or meter. Pressurize the system to the required setpoint.
Move adjusting wheel on spring B until switch changes mode.
Then lower pressure to the resetpoint, move adjusting wheel on
spring A until the switch changes mode. Raise and lower pres-
sure to insure that setpoint is correct. Repeat as necessary.

Note: Since vacuum models are already above setpoint at


atmosphere, the Normally Open (NO) circuit will be
closed as received.

2007 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614-5145, USA, Tel: 203-378-8281, Fax: 203-385-0499, www.ashcroft.com
All sales subject to standard terms and conditions of sale. I&M009-10013G-10/00 (250-2524) AMR 12/07