You are on page 1of 384

Adhesive anchoring

systems

Adhesive anchoring systems


Foil capsule systems
Injection mortar systems

10 / 2012 349
HVZ Adhesive anchor

HVZ Adhesive anchor


Mortar system Benefits

Hilti - suitable for cracked and non-


HVU-TZ foil cracked concrete C 20/25 to
capsule C 50/60
- high loading capacity
HAS-TZ - suitable for dry and water
HAS-R-TZ saturated concrete
HAS-HCR-TZ
rod

High European
Tensile Fire Corrosion CE
Concrete Fatigue Shock corrosion Technical
zone resistance resistance conformity
resistance Approval

PROFIS
Anchor
design
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
a)
European technical approval DIBt, Berlin ETA-03/0032 / 2008-09-29
Approval for shockproof fastenings Federal Office for Cicil Protection,
BZS D 09-602 / 2009-10-28
in civil defence installations Bern
Fatigue loading DIBt, Berlin Z-21.3-1692 / 2012-03-07
Fire test report ZTV-Tunnel IBMB, Braunschweig UB 3357/0550-2 / 2001-06-26
Fire test report IBMB, Brunswick UB 3357/0550-1 / 2001-04-17
Assessment report (fire) warringtonfire WF 166402 / 2007-10-26
a) All data given in this section according ETA-03/0032, issue 2008-09-29.

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- Embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +50C/80C)
- Installation temperature range 0C to +40C

350 10 / 2012
HVZ Adhesive anchor

Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended
loads.
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
Embedment depth [mm] 75 95 105 125 170
Base material thickness [mm] 150 190 210 250 340

Mean ultimate resistance a): concrete C 20/25 fck,cube = 25 N/mm, anchor HVZ
Data according ETA-03/0032, issue 2008-09-29
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
Non cracked concrete
Tensile NRu,m HVZ [kN] 36,8 53,3 72,4 94,1 149,2
Shear VRu,m HVZ [kN] 18,9 28,4 53,6 53,6 92,4
Cracked concrete
Tensile NRu,m HVZ [kN] 31,2 44,4 51,6 67,1 106,4
Shear VRu,m HVZ [kN] 18,9 28,4 53,6 53,6 92,4

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HVZ


Data according ETA-03/0032, issue 2008-09-29
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
Non cracked concrete
Tensile NRk HVZ [kN] 32,8 40,0 54,3 70,6 111,9
Shear VRk HVZ [kN] 18,0 27,0 51,0 51,0 88,0
Cracked concrete
Tensile NRk HVZ [kN] 23,4 33,3 38,7 50,3 79,8
Shear VRk HVZ [kN] 18,0 27,0 51,0 51,0 88,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HVZ


Data according ETA-03/0032, issue 2008-09-29
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
Non cracked concrete
Tensile NRd HVZ [kN] 21,9 26,7 36,2 47,1 74,6
Shear VRd HVZ [kN] 14,4 21,6 40,8 40,8 70,4
Cracked concrete
Tensile NRd HVZ [kN] 15,6 22,2 25,8 33,5 53,2
Shear VRd HVZ [kN] 14,4 21,6 40,8 40,8 70,4

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HVZ


Data according ETA-03/0032, issue 2008-09-29
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
Non cracked concrete
Tensile Nrec HVZ [kN] 15,6 19,0 25,9 33,6 53,3
Shear Vrec HVZ [kN] 10,3 15,4 29,1 29,1 50,3
Cracked concrete
Tensile Nrec HVZ [kN] 11,1 15,9 18,4 24,0 38,0
Shear Vrec HVZ [kN] 10,3 15,4 29,1 29,1 50,3
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

10 / 2012 351
HVZ Adhesive anchor

Service temperature range


Hilti HVZ adhesive anchor with anchor rod HAS-TZ may be applied in the temperature ranges given below. An
elevated base material temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +80 C +50 C +80 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of HAS-TZ
Data according ETA-03/0032, issue 2008-09-29
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
Nominal
HAS-(R)
tensile [N/mm] 800
(HCR)TZ
strength fuk
Yield HAS-(R)
[N/mm] 640
strength fyk (HCR)TZ
Stressed tension [mm] 44,2 63,6 113 113 227
cross-
section As shear [mm] 50,3 73,9 141 141 245
Moment of HAS-(R)
[mm] 50,3 89,6 236 236 541
resistance W (HCR)TZ

Material quality
Part Material
carbon steel
HAS-TZ
strength class 8.8
stainless steel
HAS-R-TZ
1.4401 and 1.4571
high corrosion resistance steel
HAS-HCR-TZ
1.4529 and 1.4547

Anchor dimensions
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
Anchor embedment depth [mm] 75 95 105 125 170

352 10 / 2012
HVZ Adhesive anchor

Setting
installation equipment
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
Rotary hammer TE 2 TE 16 / TE30/40 TE 50 TE 70
Tools Setting tools

Setting instruction

Dry and water-saturated concrete, hammer drilling

For detailed information on installation see instruction for use given with the package of the product.
For technical data for anchors in diamond drilled holes please contact the Hilti Technical advisory service.

Curing time for general conditions


Data according ETA-04/0084, issue 2007-01-03
Temperature Curing time before anchor can be fully
of the loaded tcure
base material
20 C 20 min
10 C to 20 C 30 min
0 C to 10 C 60 min
These data are valid for dry concrete only. In wet concrete the curing time must be doubled.

10 / 2012 353
HVZ Adhesive anchor

Setting details
Data according ETA-03/0032, issue 2008-09-29
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
Nominal diameter of
d0 [mm] 12 14 18 18 25
drill bit
Diameter of element d [mm] 10 12 16 16 20
Effective anchorage
hef [mm] 75 95 105 125 170
depth
Drill hole depth h1 [mm] 90 110 125 145 195
Minimum base a)
hmin [mm] 150 190 210 250 340
material thickness
Diameter of clearance
df [mm] 12 14 18 18 22
hole in the fixture
Cracked concrete
Minimum spacing smin [mm] 50 60 70 70 80
Minimum edge
cmin [mm] 50 60 70 70 80
distance
Non cracked concrete
Minimum spacing smin [mm] 50 60 70 70 80
Minimum edge
cmin [mm] 50 70 85 85 80
distance
Critical spacing for
scr,sp [mm] 2 ccr,sp
splitting failure
Critical edge distance
ccr,sp [mm] 1,5 hef
for splitting failure
Critical spacing for
scr,N 2 ccr,N
concrete cone failure
Critical edge distance
b)
for concrete cone ccr,N 1,5 hef
failure
c)
Torque moment Tmax [Nm] 40 50 90 90 150

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) h: base material thickness (h hmin)
b) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
c) This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.

354 10 / 2012
HVZ Adhesive anchor

Simplified design method


Simplified version of the design method according ETAG 001, Annex C. Design resistance according data given in
ETA-03/0032, issue 2007-01-03.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, Annex C. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p fh,p
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp f h,sp fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Data according ETA-03/0032, issue 2008-09-29
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
HAS-TZ
NRd,s HAS-R-TZ [kN] 23,3 34,0 60,0 60,0 121,3
HAS-HCR-TZ

Design combined pull-out and concrete cone resistance NRd,p = N0Rd,p fB,p fh,p
Data according ETA-03/0032, issue 2008-09-29
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
Embedment depth hef [mm] 75 95 105 125 170
Non cracked concrete
0
N Rd,p Temperature range I [kN] 21,9 26,7 36,2 47,1 74,6
Cracked concrete
0
N Rd,p Temperature range I [kN] 15,6 22,2 25,8 33,5 53,2

10 / 2012 355
HVZ Adhesive anchor

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f h,N f1,sp f2,sp f3,sp fre,N
Data according ETA-03/0032, issue 2008-09-29
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
0
N Rd,c Non cracked concrete [kN] 21,9 31,2 36,2 47,1 74,6
0
N Rd,c Cracked concrete [kN] 15,6 22,2 25,8 33,5 53,2
a) Splitting resistance must only be considered for non-cracked concrete

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0.1 a)
fB,p = (fck,cube/25N/mm) 1 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N 1
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp 1

f2,N = 0,5(1 + c/ccr,N) 1


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp) 1
a) The edge distance shall not be smaller than the minimum edge distance cmin given in the table with the setting
details. These influencing factors must be considered for every edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N) 1
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp) 1
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hef/hef,typ)

356 10 / 2012
HVZ Adhesive anchor

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Data according ETA-03/0032, issue 2008-09-29
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
VRd,s HAS-TZ [kN] 14,4 21,6 40,8 40,8 70,4
HAS-R-TZ
VRd,s [kN] 16,0 24,0 44,8 44,8 78,4
HAS-HCR-TZ

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance a) VRd,c = V0Rd,c fB f f h f4


Non-cracked concrete Cracked concrete
Anchor size M10x M12x M16x M16x M20x M10x M12x M16x M16x M20x
75 95 105 125 170 75 95 105 125 170
0
V Rd,c [kN] 3,7 6,7 9,9 10,3 11,0 2,7 3,8 5,3 5,5 7,9
a) For anchor groups only the anchors close to the edge must be considered.

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

10 / 2012 357
HVZ Adhesive anchor

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
2/3
fh = 0,22 0,34 0,45 0,54 0,63 0,71 0,79 0,86 0,93 1,00

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

358 10 / 2012
HVZ Adhesive anchor

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Data according ETA-03/0032, issue 2008-09-29
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
Embedment depth hef = [mm] 75 95 105 125 170
Base material thickness hmin= [mm] 150 190 210 250 340
Tensile NRd: single anchor, no edge effects
Non cracked concrete
HVZ
HVZ-R [kN] 21,9 26,7 36,2 47,1 74,6
HVZ-HCR
Cracked concrete
HVZ
HVZ-R [kN] 15,6 22,2 25,8 33,5 53,2
HVZ-HCR
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked and cracked concrete
HVZ [kN] 14,4 21,6 40,8 40,8 70,4
HVZ-R
[kN] 16,0 24,0 44,8 44,8 78,4
HVZ-HCR

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Data according ETA-03/0032, issue 2008-09-29
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
Embedment depth hef = [mm] 75 95 105 125 170
Base material thickness hmin= [mm] 150 190 210 250 340
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non cracked concrete
cmin [mm] 50 70 85 85 80
HVZ
HVZ-R [kN] 13,2 15,7 21,8 26,2 38,9
HVZ-HCR
Cracked concrete
cmin [mm] 50 60 70 70 80
HVZ
HVZ-R [kN] 9,4 14,0 17,1 20,4 27,7
HVZ-HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non cracked concrete
cmin [mm] 50 70 85 85 80
HVZ
HVZ-R [kN] 3,5 5,1 7,2 7,4 10,3
HVZ-HCR
Cracked concrete
cmin [mm] 50 60 70 70 80
HVZ
HVZ-R [kN] 2,5 4,6 6,9 7,1 7,4
HVZ-HCR

10 / 2012 359
HVZ Adhesive anchor

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


(load values are valid for single anchor)
Data according ETA-03/0032, issue 2008-09-29
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
Embedment depth hef = [mm] 75 95 105 125 170
Base material thickness hmin= [mm] 150 190 210 250 340
Spacing s= smin= [mm] 50 60 70 70 80
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non cracked concrete
HVZ
HVZ-R [kN] 13,4 16,1 22,1 27,9 43,2
HVZ-HCR
Cracked concrete
HVZ
HVZ-R [kN] 9,5 13,5 15,8 19,9 30,8
HVZ-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non cracked concrete
HVZ [kN] 14,4 21,6 40,8 40,8 70,4
HVZ-R
[kN] 16,0 24,0 44,3 44,8 78,4
HVZ-HCR
Cracked concrete
HVZ [kN] 14,4 21,6 31,6 39,8 61,5
HVZ-R
[kN] 16,0 24,0 31,6 39,8 61,5
HVZ-HCR

360 10 / 2012
HVZ Adhesive anchor

10 / 2012 361
HVU with HAS/HAS-E rod
Adhesive anchor

HVU with HAS/HAS-E rod adhesive anchor


Mortar system Benefits

- suitable for non-cracked concrete


Hilti
C 20/25 to C 50/60
HVU foil capsule
- high loading capacity
- suitable for dry and water
saturated concrete
HAS - large diameter applications
HAS-R
- high corrosion resistant
HAS-HCR rod

HAS-E
HAS-E R
HAS-E HCR rod

PROFIS
Small edge High European
Fire Corrosion CE Anchor
Concrete distance corrosion Technical
resistance resistance conformity design
and spacing resistance Approval
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
a)
European technical approval DIBt, Berlin ETA-05/0255 / 2011-06-23
Fire test report IBMB, Braunschweig UB-3333/0891-1 / 2004-03-26
Fire test report ZTV-Tunnel IBMB, Braunschweig UB 3333/0891-2 / 2003-08-12
Assessment report (fire) warringtonfire WF 166402 / 2007-10-26
a) All data given in this section according ETA-05/0255, issue 2011-06-23

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range -5C to +40C

362 10 / 2012
HVU with HAS/HAS-E rod
Adhesive anchor

Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended
loads.
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth [mm] 80 90 110 125 170 210 240 270
Base material thickness [mm] 140 160 210 210 340 370 480 540
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.

Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HAS


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Carbon steel, strength class 5.8 5.8 5.8 5.8 5.8 5.8 8.8 8.8
Tensile NRu,m HAS [kN] 17,9 27,3 39,9 75,6 117,6 168,0 249,3 297,4
Shear VRu,m HAS [kN] 8,9 13,7 20,0 37,8 58,8 84,0 182,7 221,6

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HAS


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Carbon steel, strength class 5.8 5.8 5.8 5.8 5.8 5.8 8.8 8.8
Tensile NRk HAS [kN] 17,0 26,0 38,0 60,0 111,9 140,0 187,8 224,0
Shear VRk HAS [kN] 8,5 13,0 19,0 36,0 56,0 80,0 174,0 211,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HAS


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Carbon steel, strength class 5.8 5.8 5.8 5.8 5.8 5.8 8.8 8.8
Tensile NRd HAS [kN] 11,3 17,3 25,3 40,0 74,6 93,3 125,2 149,4
Shear VRd HAS [kN] 6,8 10,4 15,2 28,8 44,8 64,0 139,2 168,8

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HAS


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Carbon steel, strength class 5.8 5.8 5.8 5.8 5.8 5.8 8.8 8.8
Tensile Nrec HAS [kN] 8,1 12,4 18,1 28,6 53,3 66,7 89,4 106,7
Shear Vrec HAS [kN] 4,9 7,4 10,9 20,6 32,0 45,7 99,4 120,6
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HVU adhesive may be applied in the temperature ranges given below. An elevated base material temperature
may lead to a reduction of the design bond resistance.
Maximum long term Maximum short term
Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +80 C +50 C +80 C
Temperature range III -40 C to +120 C +72 C +120 C

10 / 2012 363
HVU with HAS/HAS-E rod
Adhesive anchor

Max short term base material temperature


Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of HAS
Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HAS-(E)(F) 5.8 [N/mm] 500 500 500 500 500 500 - -
Nominal HAS-(E)(F) 8.8 [N/mm] 800 800 800 800 800 800 800 800
tensile
strength fuk HAS-(E)R [N/mm] 700 700 700 700 700 700 500 500
HAS-(E)HCR [N/mm] 800 800 800 800 800 700 - -
HAS-(E)(F) 5.8 [N/mm] 400 400 400 400 400 400 - -
Yield HAS-(E)(F) 8.8 [N/mm] 640 640 640 640 640 640 640 640
strength fyk HAS (E)R [N/mm] 450 450 450 450 450 450 210 210
HAS (E)HCR [N/mm] 640 640 640 640 640 400 - -
Stressed
cross- HAS [mm] 32,8 52,3 76,2 144 225 324 427 519
section As
Moment of
resistance HAS [mm] 27,0 54,1 93,8 244 474 809 1274 1706
W

Material quality
Part Material
Strength class 5.8, A5 > 8% ductile
Threaded rod
steel galvanized 5 m
HAS-(E)(F) M8-M24
(F) hot dipped galvanized 45 m,
Strength class 8.8, A5 > 8% ductile
Threaded rod
steel galvanized 5 m,
HAS-(E)F M8-M30
(F) hot dipped galvanized 45 m,
Stainless steel grade A4, A5 > 8% ductile
Threaded rod
strength class 70 for M24 and class 50 for M27 to M30, 1.4401; 1.4404;
HAS-(E)R
1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, 1.4529; 1.4565
Threaded rod
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
HAS-(E)HCR
M24: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, hot dipped galvanized,
Washer
Stainless steel, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
ISO 7089
High corrosion resistant steel, 1.4529; 1.4565
Strength class 8,
steel galvanized 5 m,
hot dipped galvanized 45 m,
Nut
Strength class 70, stainless steel grade A4,
EN ISO 4032
1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, high corrosion resistant steel,
1.4529; 1.4565

364 10 / 2012
HVU with HAS/HAS-E rod
Adhesive anchor

Anchor dimensions
Anchor size M8 M10 M12 M16 M20 M24 M27 M30

Anchor rod

M12x110

M16x125

M20x170

M24x210

M27x240

M30x270
M10x90
M8x80
HAS-E,
HAS-R, HAS-ER
HAS-HCR

Anchor embedment depth [mm] 80 90 110 125 170 210 240 270

Setting
installation equipment
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools blow out pump or compressed air gun, setting tools

Setting instruction

Dry and water-saturated concrete, hammer drilling

For detailed information on installation see instruction for use given with the package of the product.
For technical data for anchors in diamond drilled holes please contact the Hilti Technical advisory service.

10 / 2012 365
HVU with HAS/HAS-E rod
Adhesive anchor

Curing time for general conditions


Data according ETA-05/0255, issue 2011-06-23
Temperature of the base material Curing time before anchor can be fully loaded tcure
20 C to 40 C 20 min
10 C to 19 C 30 min
0 C to 9 C 1h
-5 C to - 1 C 5h

Setting details
Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Nominal diameter of
d0 [mm] 10 12 14 18 24 28 30 35
drill bit
Effective anchorage
hef [mm] 80 90 110 125 170 210 240 270
and drill hole depth
Minimum base a)
hmin [mm] 110 120 140 170 220 270 300 340
material thickness
Diameter of clearance
df [mm] 9 12 14 18 22 26 30 33
hole in the fixture
Minimum spacing smin [mm] 40 45 55 65 90 120 130 135
Minimum edge
cmin [mm] 40 45 55 65 90 120 130 135
distance
Critical spacing for
scr,sp 2 ccr,sp
splitting failure
1,0 hef for h / hef 2,0

Critical edge distance


b) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N 1,5 hef
c)
failure
Critical spacing for
scr,N 2 ccr,N
concrete cone failure
Critical edge distance for
ccr,N 1,5 hef
concrete cone failure
c)
Torque moment Tmax [Nm] 10 20 40 80 150 200 270 300

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be reduced.
a) h: base material thickness (h hmin)
b) h: base material thickness (h hmin)
c) This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.

366 10 / 2012
HVU with HAS/HAS-E rod
Adhesive anchor

Simplified design method


Simplified version of the design method according EOTA Technical Report TR 029. Design resistance according
data given in ETA-05/0255, issue 2011-06-23.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according EOTA Technical Report TR 029. To avoid this, it is recommended to use the
anchor design software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p fh,p
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp f h,sp fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HAS-(E)(F) 5.8 [kN] 11,3 17,3 25,3 48,0 74,7 106,7 - -
HAS-(E)(F) 8.8 [kN] 18,0 28,0 40,7 76,7 119,3 170,7 231,3 281,3
NRd,s
HAS-(E)-R [kN] 12,3 19,8 28,3 54,0 84,0 119,8 75,9 92,0
HAS-(E)-HCR [kN] 18,0 28,0 40,7 76,7 119,3 106,7 - -

Design combined pull-out and concrete cone resistance NRd,p = N0Rd,p fB,p fh,p
Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth
80 90 110 125 170 200 210 270
hef,typ [mm]
0
N Rd,p Temperature range I [kN] 16,7 23,3 33,3 40,0 76,7 93,3 133,3 166,7
0
N Rd,p Temperature range II [kN] 13,3 16,7 26,7 33,3 50,0 76,7 93,3 113,3
0
N Rd,p Temperature range III [kN] 6,0 8,0 10,7 16,7 26,7 40,0 50,0 50,0

10 / 2012 367
HVU with HAS/HAS-E rod
Adhesive anchor

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f h,N f1,sp f2,sp f3,sp fre,N
Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
0
N Rd,c [kN] 24,1 28,7 38,8 47,1 74,6 102,5 125,2 149,4
a) Splitting resistance must only be considered for non-cracked concrete

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,14 a)
fB,p = (fck,cube/25N/mm) 1 1,03 1,06 1,09 1,10 1,12 1,13
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = 1

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


fh,N = 1

368 10 / 2012
HVU with HAS/HAS-E rod
Adhesive anchor

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HAS -(E) [kN] 6,6 10,6 15,2 28,8 44,9 64,1 138,8 168,6
HAS -(E)F [kN] 10,6 16,9 24,4 46,1 71,8 102,6 138,8 168,6
VRd,s
HAS (-E)-R [kN] 7,5 11,9 17,1 32,4 50,5 72,1 45,5 55,3
HAS (-E)-HCR [kN] 10,6 16,9 24,4 46,1 71,8 64,1 - -

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
k 2
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
0
V Rd,c [kN] 5,9 8,5 11,6 18,8 27,3 37 45,1 53,8
a) For anchor groups only the anchors close to the edge must be considered.

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

10 / 2012 369
HVU with HAS/HAS-E rod
Adhesive anchor

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
0,05 (hef / d)
1,68
f hef = 2,39 2 2,07 1,58 1,82 1,91 1,96 2

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.
370 10 / 2012
HVU with HAS/HAS-E rod
Adhesive anchor

Precalculated values
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Carbon steel, strength class 5.8 5.8 5.8 5.8 5.8 5.8 8.8 8.8
Embedment depth hef = [mm] 80 90 110 125 170 210 240 270
Base material thickness hmin= [mm] 110 120 140 170 220 270 300 340
Tensile NRd: single anchor, no edge effects
HAS-(E)(F) [kN] 11,3 17,3 25,3 40,0 74,6 93,3 125,2 149,4
HAS-(E)-R [kN] 12,3 19,8 28,3 40,0 74,6 93,3 75,9 92,0
HAS-(E)-HCR [kN] 16,7 23,3 33,3 40,0 74,6 93,3 - -
Shear VRd: single anchor, no edge effects, without lever arm
HAS-(E)(F) [kN] 6,8 10,4 15,2 28,8 44,8 64,0 139,2 168,8
HAS-(E)-R [kN] 7,7 11,5 17,3 32,7 50,6 71,8 45,4 55,5
HAS-(E)-HCR [kN] 9,6 14,4 21,6 40,8 63,2 64,0 - -

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Carbon steel, strength class 5.8 5.8 5.8 5.8 5.8 5.8 8.8 8.8
Embedment depth hef = [mm] 80 90 110 125 170 210 240 270
Base material thickness hmin= [mm] 110 120 140 170 220 270 300 340
Edge distance c = cmin= [mm] 40 45 55 65 90 120 130 135
Tensile NRd: single anchor, min. edge distance (c = cmin)
HAS-(E)(F) [kN] 9,4 12,7 18,2 22,0 35,5 49,8 59,9 69,9
HAS-(E)-R [kN] 9,4 12,7 18,2 22,0 35,5 49,8 59,9 69,9
HAS-(E)-HCR [kN] 9,4 12,7 18,2 22,0 35,5 49,8 - -
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
HAS-(E)(F) [kN] 3,7 4,7 6,6 8,9 15,1 23,6 27,7 30,7
HAS-(E)-R [kN] 3,7 4,7 6,6 8,9 15,1 23,6 27,7 30,7
HAS-(E)-HCR [kN] 3,7 4,7 6,6 8,9 15,1 23,6 - -

Design resistance: concrete C 20/25 fck,cube = 25 N/mm (load values are valid for single anchor)
Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Carbon steel, strength class 5.8 5.8 5.8 5.8 5.8 5.8 8.8 8.8
Embedment depth hef = [mm] 80 90 110 125 170 210 240 270
Base material thickness hmin= [mm] 110 120 140 170 220 270 300 340
Spacing s = smin= [mm] 40 45 55 65 90 120 130 135
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HAS-(E)(F) [kN] 10,9 14,6 20,6 24,8 41,7 57,7 70,1 82,9
HAS-(E)-R [kN] 10,9 14,6 20,6 24,8 41,7 57,7 70,1 82,9
HAS-(E)-HCR [kN] 10,9 14,6 20,6 24,8 41,7 57,7 - -
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HAS-(E)(F) [kN] 6,8 10,4 15,2 28,8 44,8 64,0 139,2 168,8
HAS-(E)-R [kN] 7,7 11,5 17,3 32,7 50,6 71,8 45,4 55,5
HAS-(E)-HCR [kN] 9,6 14,4 21,6 40,8 63,2 64,0 - -

10 / 2012 371
HVU with HIS-(R)N sleeve
Adhesive anchor

HVU with HIS-(R)N adhesive anchor


Mortar system Benefits

Hilti - suitable for non-cracked concrete


HVU foil capsule C 20/25 to C 50/60
- high loading capacity
- suitable for dry and water
saturated concrete
HIS-(R)N sleeve

PROFIS
Small edge European
Fire Corrosion CE Anchor
Concrete distance Technical
resistance resistance conformity design
and spacing Approval
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
a)
European technical approval DIBt, Berlin ETA-05/0255 / 2011-06-23
Fire test report IBMB, Braunschweig UB-3333/0891-1 / 2004-03-26
Assessment report (fire) warringtonfire WF 166402 / 2007-10-26
a) All data given in this section according ETA-05/0255, issue 2011-06-23.

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Screw strength class 8.8
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range -5C to +40C

Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended
loads.
Anchor size M8 M10 M12 M16 M20
Embedment depth [mm] 90 110 125 170 205
Base material thickness [mm] 120 150 180 250 350

372 10 / 2012
HVU with HIS-(R)N sleeve
Adhesive anchor

Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20
Tensile NRu,m HIS-N [kN] 26,3 48,3 70,4 123,9 114,5
Shear VRu,m HIS-N [kN] 13,7 24,2 41,0 62,0 57,8

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20
Tensile NRk HIS-N [kN] 25,0 40,0 60,0 95,0 109,0
Shear VRk HIS-N [kN] 13,0 23,0 39,0 59,0 55,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20
Tensile NRd HIS-N [kN] 16,7 26,7 40,0 63,3 74,1
Shear VRd HIS-N [kN] 10,4 18,4 26,0 39,3 36,7

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20
Tensile Nrec HIS-N [kN] 11,9 19,0 28,6 45,2 53,0
Shear Vrec HIS-N [kN] 7,4 13,1 18,6 28,1 26,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HVU adhesive may be applied in the temperature ranges given below. An elevated base material temperature
may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +80 C +50 C +80 C
Temperature range III -40 C to +120 C +72 C +120 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

10 / 2012 373
HVU with HIS-(R)N sleeve
Adhesive anchor

Materials
Mechanical properties of HIS-(R)N
Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20
HIS-N [N/mm] 490 490 460 460 460
Nominal Screw 8.8 [N/mm] 800 800 800 800 800
tensile
strength fuk HIS-RN [N/mm] 700 700 700 700 700
Screw A4-70 [N/mm] 700 700 700 700 700
HIS-N [N/mm] 410 410 375 375 375
Yield Screw 8.8 [N/mm] 640 640 640 640 640
strength fyk HIS-RN [N/mm] 350 350 350 350 350
Screw A4-70 [N/mm] 450 450 450 450 450
Stressed HIS-(R)N [mm] 51,5 108,0 169,1 256,1 237,6
cross-
section As Screw [mm] 36,6 58 84,3 157 245
Moment of HIS-(R)N [mm] 145 430 840 1595 1543
resistance W Screw [mm] 31,2 62,3 109 277 541

Material quality
Part Material
a)
internally threaded sleeves C-steel 1.0718,
HIS-N steel galvanized 5m
b)
internally threaded sleeves
stainless steel 1.4401 and 1.4571
HIS-RN
a) related fastening screw: strength class 8.8, A5 > 8% Ductile
steel galvanized 5m
b) related fastening screw: strength class 70, A5 > 8% Ductile
stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362

Anchor dimensions
Anchor size M8 M10 M12 M16 M20
Internal sleeve HIS-(R)N M8x90 M10x110 M12x125 M16x170 M20x205
Anchor embedment depth [mm] 90 110 125 170 205

Setting
installation equipment
Anchor size M8 M10 M12 M16 M20
Rotary hammer TE2 TE16 TE40 TE70
Other tools blow out pump or compressed air gun, setting tools

374 10 / 2012
HVU with HIS-(R)N sleeve
Adhesive anchor

Setting instruction

Dry and water-saturated concrete, hammer drilling

For detailed information on installation see instruction for use given with the package of the product.
For technical data for anchors in diamond drilled holes please contact the Hilti Technical advisory service.

Curing time for general conditions


Data according ETA-05/0255, issue 2011-06-23
Temperature Curing time before anchor
of the base material can be fully loaded tcure
20 C to 40 C 20 min
10 C to 19 C 30 min
0 C to 9 C 1h
-5 C to - 1 C 5h

10 / 2012 375
HVU with HIS-(R)N sleeve
Adhesive anchor

Setting details
Data according ETA-05/0255, issue 2011-06-23
Sleeve HIS-(R)N M8x90 M10x110 M12x125 M16x170 M20x205
Anchor size
foil capsule M10x90 M12x110 M16x125 M20x170 M24x210
Nominal diameter of
d0 [mm] 14 18 22 28 32
drill bit
Diameter of element d [mm] 12,5 16,5 20,5 25,4 27,6
Effective anchorage
hef [mm] 90 110 125 170 205
and drill hole depth
Minimum base
hmin [mm] 120 150 170 230 270
material thickness
Diameter of clearance
df [mm] 9 12 14 18 22
hole in the fixture
Thread engagement
hs [mm] 8-20 10-25 12-30 16-40 20-50
length; min - max
Minimum spacing smin [mm] 40 45 60 80 125
Minimum edge
cmin [mm] 40 45 60 80 125
distance
Critical spacing for
scr,sp 2 ccr,sp
splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


a) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N 2 ccr,N
concrete cone failure
Critical edge distance for
ccr,N 1,5 hef
concrete cone failure
b)
Torque moment Tmax [Nm] 10 20 40 80 150

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) h: base material thickness (h hmin)
b) This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.

Simplified design method


Simplified version of the design method according EOTA Technical Report TR 029. Design resistance according
data given in ETA-05/0255, issue 2011-06-23.
Influence of concrete strength
Influence of edge distance
Influence of spacing
376 10 / 2012
HVU with HIS-(R)N sleeve
Adhesive anchor

Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according EOTA Technical Report TR 029. To avoid this, it is recommended to use the
anchor design software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p fh,p
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp f h,sp fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20
HIS-N [kN] 17,5 30,7 44,7 80,3 74,1
NRd,s
HIS-RN [kN] 13,9 21,9 31,6 58,8 69,2

Design combined pull-out and concrete cone resistance NRd,p = N0Rd,p fB,p fh,p
Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20
Embedment depth
90 110 125 170 205
hef [mm]
0
N Rd,p Temperature range I [kN] 16,7 26,7 40,0 63,3 93,3
0
N Rd,p Temperature range II [kN] 13,3 23,3 33,3 50,0 63,3
0
N Rd,p Temperature range III [kN] 6,0 10,7 13,3 26,7 33,3

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f h,N f1,sp f2,sp f3,sp fre,N
Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20
0
N Rd,c [kN] 28,7 38,8 47,1 74,6 98,8
a) Splitting resistance must only be considered for non-cracked concrete

10 / 2012 377
HVU with HIS-(R)N sleeve
Adhesive anchor

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,28 a)
fB,p = (fck,cube/25N/mm) 1 1,05 1,12 1,18 1,21 1,25 1,28
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = 1

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


fh,N = 1

Influence of reinforcement
hef [mm] 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a)
0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.

378 10 / 2012
HVU with HIS-(R)N sleeve
Adhesive anchor

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
VRd,s
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

Design concrete pryout resistance VRd,cp = k NRd,ca)


Anchor size M8 M10 M12 M16 M20
k 2
a) NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20
0
V Rd,c [kN] 12,4 19,8 28,4 40,7 46,8
a) For anchor groups only the anchors close to the edge must be considered.

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

10 / 2012 379
HVU with HIS-(R)N sleeve
Adhesive anchor

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


Anchor size M8 M10 M12 M16 M20
0,05 (hef / d)
1,68
f hef = 1,38 1,21 1,04 1,22 1,45

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

380 10 / 2012
HVU with HIS-(R)N sleeve
Adhesive anchor

Precalculated values
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 90 110 125 170 205
Base material thickness hmin= [mm] 120 150 170 230 270
Tensile NRd: single anchor, no edge effects
HIS-N [kN] 16,7 26,7 40,0 63,3 74,1
HIS-RN [kN] 13,9 21,9 31,6 58,8 69,2
Shear VRd: single anchor, no edge effects, without lever arm
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 90 110 125 170 205
Base material thickness hmin= [mm] 120 150 170 230 270
Edge distance c = cmin= [mm] 40 45 60 80 125
Tensile NRd: single anchor, min. edge distance (c = cmin)

HIS-(R)N [kN] 8,9 13,4 21,0 33,5 49,2

Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm

HIS-(R)N [kN] 4,2 5,5 8,5 13,8 25,3

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


(load values are valid for single anchor)
Data according ETA-05/0255, issue 2011-06-23
Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 90 110 125 170 205
Base material thickness hmin= [mm] 120 150 170 230 270
Spacing s = smin= [mm] 40 45 60 80 125
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)

HIS-(R)N [kN] 11,0 16,9 24,4 38,8 56,2

Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

10 / 2012 381
Hilti HIT-RE 500-SD
with HIT-V rod

Hilti HIT-RE 500-SD with HIT-V rod


Injection mortar system Benefits

Hilti HIT- - suitable for non-cracked and


RE 500-SD 330 cracked concrete C 20/25 to
ml foil pack C 50/60
(also available - high loading capacity
as 500 ml - suitable for dry and water
and 1400 ml saturated concrete
foil pack) - large diameter applications
- high corrosion resistant
- long working time at elevated
Static mixer temperatures
- odourless epoxy
- embedment depth range:
HIT-V rod from 40 160 mm for M8
to 120 600 mm for M30

Small edge Variable High


Tensile Fire Corrosion
Concrete distance embedment Shock Seismic corrosion
zone resistance resistance
and spacing depth resistance

PROFIS
European
CE Anchor
Technical
conformity design
Approval
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
a)
European technical approval DIBt, Berlin ETA-07/0260 / 2009-01-12
ES report icl. seismic ICC evaluation service ESR 2322 / 2012-02-01
Shockproof fastenings in civil Federal Office for Cicil Protection,
BZS D 08-604 / 2009-10-21
defence installations Bern
Fire test report MFPA, Leipzig GS-III/B-07-070 / 2008-01-18
Assessment report (fire) warringtonfire WF 166402 / 2007-10-26 & suppl.
WF 172920 / 2008-05-27
a) All data given in this section according ETA-07/0260, issue 2009-01-12.

382 10 / 2012
Hilti HIT-RE 500-SD
with HIT-V rod

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range +5C to +40C

Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended
loads.
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth [mm] 80 90 110 125 170 210 240 270
Base material thickness [mm] 110 120 140 165 220 270 300 340
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.

Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8
Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non cracked concrete
Tensile NRu,m HIT-V 5.8 [kN] 18,9 30,5 44,1 83,0 129,2 185,9 241,5 295,1
Shear VRu,m HIT-V 5.8 [kN] 9,5 15,8 22,1 41,0 64,1 92,4 120,8 147,0
Cracked concrete
Tensile NRu,m HIT-V 5.8 [kN] 18,9 30,5 44,1 65,2 110,8 146,1 196,0 226,2
Shear VRu,m HIT-V 5.8 [kN] 9,5 15,8 22,1 41,0 64,1 92,4 120,8 147,0

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non cracked concrete
Tensile NRk HIT-V 5.8 [kN] 18,0 29,0 42,0 70,6 111,9 153,7 187,8 224,0
Shear VRk HIT-V 5.8 [kN] 9,0 15,0 21,0 39,0 61,0 88,0 115,0 140,0
Cracked concrete
Tensile NRk HIT-V 5.8 [kN] 16,1 22,6 31,1 44,0 74,8 109,6 132,3 152,7
Shear VRk HIT-V 5.8 [kN] 9,0 15,0 21,0 39,0 61,0 88,0 115,0 140,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non cracked concrete
Tensile NRd HIT-V 5.8 [kN] 12,0 19,3 28,0 33,6 53,3 73,2 89,4 106,7
Shear VRd HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
Cracked concrete
Tensile NRd HIT-V 5.8 [kN] 8,9 12,6 17,3 20,9 35,6 52,2 63,0 72,7
Shear VRd HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0

10 / 2012 383
Hilti HIT-RE 500-SD
with HIT-V rod

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8
Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non cracked concrete
Tensile Nrec HIT-V 5.8 [kN] 8,6 13,8 20,0 24,0 38,1 52,3 63,9 76,2
Shear Vrec HIT-V 5.8 [kN] 5,1 8,6 12,0 22,3 34,9 50,3 65,7 80,0
Cracked concrete
Tensile Nrec HIT-V 5.8 [kN] 6,4 9,0 12,3 15,0 25,4 37,3 45,0 51,9
Shear Vrec HIT-V 5.8 [kN] 5,1 8,6 12,0 22,3 34,9 50,3 65,7 80,0
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-RE 500-SD injection mortar may be applied in the temperature ranges given below. An elevated base
material temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +58 C +35 C +58 C
Temperature range III -40 C to +70 C +43 C +70 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of HIT-V / HAS
Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HIT-V 5.8 [N/mm] 500 500 500 500 500 500 500 500
Nominal HIT-V 8.8 [N/mm] 800 800 800 800 800 800 800 800
tensile
strength fuk HIT-V-R [N/mm] 700 700 700 700 700 700 500 500
HIT-V-HCR [N/mm] 800 800 800 800 800 700 700 700
HIT-V 5.8 [N/mm] 400 400 400 400 400 400 400 400
Yield strength HIT-V 8.8 [N/mm] 640 640 640 640 640 640 640 640
fyk HIT-V -R [N/mm] 450 450 450 450 450 450 210 210
HIT-V -HCR [N/mm] 600 600 600 600 600 400 400 400
Stressed
cross-section HIT-V [mm] 36,6 58,0 84,3 157 245 353 459 561
As
Moment of
HIT-V [mm] 31,2 62,3 109 277 541 935 1387 1874
resistance W

384 10 / 2012
Hilti HIT-RE 500-SD
with HIT-V rod

Material quality
Part Material
Strength class 5.8, A5 > 8% ductile
Threaded rod
steel galvanized 5 m,
HIT-V(F) 5.8
(F) hot dipped galvanized 45 m,
Strength class 8.8, A5 > 8% ductile
Threaded rod
steel galvanized 5 m,
HIT-V(F) 8.8
(F) hot dipped galvanized 45 m,
Stainless steel grade A4, A5 > 8% ductile
Threaded rod
strength class 70 for M24 and class 50 for M27 to M30, 1.4401; 1.4404;
HIT-V-R
1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, 1.4529; 1.4565
Threaded rod
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
HIT-V-HCR
M24 to M30: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, hot dipped galvanized
Washer
Stainless steel, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
ISO 7089
High corrosion resistant steel, 1.4529; 1.4565
Strength class 8,
steel galvanized 5 m,
hot dipped galvanized 45 m
Nut
Strength class 70, stainless steel grade A4,
EN ISO 4032
1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, high corrosion resistant steel,
1.4529; 1.4565

Anchor dimensions
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Anchor embedment depth [mm] 80 90 110 125 170 210 240 270
Anchor rod
Anchor rods HIT-V (-R / -HCR) are available in variable length
HIT-V, HIT-V-R, HIT-V-HCR

Setting
installation equipment
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Rotary hammer TE2 TE16 TE40 TE70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

10 / 2012 385
Hilti HIT-RE 500-SD
with HIT-V rod

Setting instruction

Dry and water-saturated concrete, hammer drilling

Brush bore hole with required steel brush HIT-RB


For detailed information on installation see instruction for use given with the package of the product.

Curing time for general conditions


Data according ETA-07/0260, issue 2009-01-12
Temperature Working time in which anchor Curing time before anchor
of the base material can be inserted and adjusted tgel can be fully loaded tcure
40 C 12 min 4h
30 C to 39 C 12 min 8h
20 C to 29 C 20 min 12 h
15 C to 19 C 30 min 24 h
10 C to 14 C 90 min 48 h
5 C to 9 C 120 min 72 h

386 10 / 2012
Hilti HIT-RE 500-SD
with HIT-V rod

Setting details
Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Nominal diameter of
d0 [mm] 10 12 14 18 24 28 30 35
drill bit
Effective anchorage hef,min [mm] 40 40 48 64 80 96 108 120
and drill hole depth
range
a) hef,max [mm] 160 200 240 320 400 480 540 600
Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness 100 mm
Diameter of clearance
df [mm] 9 12 14 18 22 26 30 33
hole in the fixture
Minimum spacing smin [mm] 40 50 60 80 100 120 135 150
Minimum edge
cmin [mm] 40 50 60 80 100 120 135 150
distance
Critical spacing for
scr,sp 2 ccr,sp
splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


b) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N 1,5 hef
c)
failure
d)
Torque moment Tmax [Nm] 10 20 40 80 150 200 270 300

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) hef,min hef hef,max (hef: embedment depth)
b) h: base material thickness (h hmin)
c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
d) This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.

10 / 2012 387
Hilti HIT-RE 500-SD
with HIT-V rod

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in
ETA-07/0260, issue 2009-01-12.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HIT-V 5.8 [kN] 12,0 19,3 28,0 52,7 82,0 118,0 153,3 187,3
HIT-V 8.8 [kN] 19,3 30,7 44,7 84,0 130,7 188,0 244,7 299,3
NRd,s
HIT-V-R [kN] 13,9 21,9 31,6 58,8 92,0 132,1 80,4 98,3
HIT-V-HCR [kN] 19,3 30,7 44,7 84,0 130,7 117,6 152,9 187,1

388 10 / 2012
Hilti HIT-RE 500-SD
with HIT-V rod

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth
80 90 110 125 170 210 240 270
hef,typ [mm]
Non cracked concrete
0
N Rd,p Temperature range I [kN] 17,9 25,1 36,9 44,9 76,3 105,6 135,7 157,5
0
N Rd,p Temperature range II [kN] 14,5 20,4 29,9 35,9 61,0 82,9 106,6 133,3
0
N Rd,p Temperature range III [kN] 8,9 12,6 18,4 22,4 35,6 52,8 63,0 78,8
Cracked concrete
0
N Rd,p Temperature range I [kN] 8,9 12,6 17,3 20,9 35,6 52,8 63,0 72,7
0
N Rd,p Temperature range II [kN] 7,3 9,4 13,8 18,0 28,0 41,5 48,5 60,6
0
N Rd,p Temperature range III [kN] 4,5 5,5 8,1 10,5 15,3 22,6 29,1 36,4

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
0
N Rd,c Non cracked concrete [kN] 20,1 24,0 32,4 33,6 53,3 73,2 89,4 106,7
0
N Rd,c Cracked concrete [kN] 14,3 17,1 23,1 24,0 38,0 52,2 63,7 76,1
a) Splitting resistance must only be considered for non-cracked concrete

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,1 a)
fB,p = (fck,cube/25N/mm) 1 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

10 / 2012 389
Hilti HIT-RE 500-SD
with HIT-V rod

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hef/hef,typ)

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

390 10 / 2012
Hilti HIT-RE 500-SD
with HIT-V rod

Basic design shear resistance

Design steel resistance VRd,s


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
VRd,s
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 18,7 27,0 36,6 44,5 53,0
Cracked concrete
0
V Rd,c [kN] 4,2 6,1 8,2 13,2 19,2 25,9 31,5 37,5

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

10 / 2012 391
Hilti HIT-RE 500-SD
with HIT-V rod

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


hef/d 4 4,5 5 6 7 8 9 10 11
0,05 (hef / d)
1,68
f hef = 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81

hef/d 12 13 14 15 16 17 18 19 20
0,05 (hef / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

392 10 / 2012
Hilti HIT-RE 500-SD
with HIT-V rod

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef,1 = [mm] 48 60 72 96 120 144 162 180
Base material thickness hmin= [mm] 100 100 102 132 168 200 222 250
Tensile NRd: single anchor, no edge effects
Non cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 9,3 13,0 17,1 22,6 31,6 41,6 49,6 58,1
HIT-V-R
HIT-V-HCR
Cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 5,4 8,4 11,3 16,1 22,5 29,6 35,3 41,4
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 11,2 18,4 27,2 50,4 78,4 112,8 138,8 162,6
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 11,2 18,4 27,2 50,4 78,4 70,9 92,0 112,0
Cracked concrete
HIT-V 5.8 [kN] 6,4 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 6,4 18,4 27,1 45,0 63,1 82,9 99,0 115,9
HIT-V-R [kN] 6,4 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 6,4 18,4 27,1 45,0 63,1 70,9 92,0 112,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef,1 = [mm] 48 60 72 96 120 144 162 180
Base material thickness hmin= [mm] 100 100 102 132 168 200 222 250
Edge distance c = cmin= [mm] 40 50 60 80 100 120 135 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 6,3 8,5 9,9 12,9 18,2 23,8 28,2 33,2
HIT-V-R
HIT-V-HCR
Cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 3,6 5,6 7,1 9,2 12,9 16,9 20,1 23,7
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 3,4 4,9 6,7 10,8 15,7 21,4 26,0 31,1
HIT-V-R
HIT-V-HCR
Cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 2,4 3,5 4,7 7,6 11,1 15,1 18,4 22,0
HIT-V-R
HIT-V-HCR

10 / 2012 393
Hilti HIT-RE 500-SD
with HIT-V rod

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef,1 = [mm] 48 60 72 96 120 144 162 180
Base material thickness hmin= [mm] 100 100 102 132 168 200 222 250
Spacing s = smin= [mm] 40 50 60 80 100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 6,0 8,2 10,3 13,5 19,0 24,9 29,6 34,8
HIT-V-R
HIT-V-HCR
Cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 3,6 5,5 7,4 9,6 13,5 17,8 21,1 24,8
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 88,7 103,9
HIT-V 8.8 [kN] 7,2 18,4 26,3 40,5 56,5 74,3 88,7 103,9
HIT-V-R [kN] 7,2 12,8 19,2 35,3 55,1 74,3 48,3 58,8
HIT-V-HCR [kN] 7,2 18,4 26,3 40,5 56,5 70,9 88,7 103,9
Cracked concrete
HIT-V 5.8 [kN] 4,1 12,0 16,8 28,8 40,3 53,0 63,2 74,1
HIT-V 8.8 [kN] 4,1 12,8 17,3 28,8 40,3 53,0 63,2 74,1
HIT-V-R [kN] 4,1 12,8 17,3 28,8 40,3 53,0 48,3 58,8
HIT-V-HCR [kN] 4,1 12,8 17,3 28,8 40,3 53,0 63,2 74,1

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef,typ = [mm] 80 90 110 125 170 210 240 270
Base material thickness hmin= [mm] 110 120 140 161 218 266 300 340
Tensile NRd: single anchor, no edge effects
Non cracked concrete
HIT-V 5.8 [kN] 12,0 19,3 28,0 33,6 53,3 73,2 89,4 106,7
HIT-V 8.8 [kN] 17,9 24,0 32,4 33,6 53,3 73,2 89,4 106,7
HIT-V-R [kN] 13,9 21,9 31,6 33,6 53,3 73,2 80,4 98,3
HIT-V-HCR [kN] 17,9 24,0 32,4 33,6 53,3 73,2 89,4 106,7
Cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 8,9 12,6 17,3 20,9 35,6 52,2 63,0 72,7
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0
Cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 41,9 71,2 70,9 92,0 112,0

394 10 / 2012
Hilti HIT-RE 500-SD
with HIT-V rod

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef,typ = [mm] 80 90 110 125 170 210 240 270
Base material thickness hmin = [mm] 110 120 140 161 218 266 300 340
Edge distance c = cmin= [mm] 40 50 60 80 100 120 135 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 9,6 11,6 15,5 16,9 26,1 35,6 43,3 51,4
HIT-V-R
HIT-V-HCR
Cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 4,8 7,0 9,5 12,1 18,6 25,4 30,8 36,7
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 3,7 5,3 7,3 11,5 17,2 23,6 29,0 34,8
HIT-V-R
HIT-V-HCR
Cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 2,6 3,8 5,2 8,1 12,2 16,7 20,5 24,7
HIT-V-R
HIT-V-HCR
Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I
(load values are valid for single anchor)
Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef,typ = [mm] 80 90 110 125 170 210 240 270
Base material thickness hmin= [mm] 110 120 140 161 218 266 300 340
Spacing s = smin= [mm] 40 50 60 80 100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 10,9 13,5 18,1 19,2 30,1 41,2 50,3 59,9
HIT-V-R
HIT-V-HCR
Cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 5,9 8,1 11,1 13,2 21,5 29,4 35,8 42,7
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 177,0
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0
Cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 17,9 24,5 35,6 59,6 86,9 104,8 120,6
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 17,9 24,5 35,6 59,6 70,9 92,0 112,0

10 / 2012 395
Hilti HIT-RE 500-SD
with HIT-V rod

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef,2 = [mm] 96 120 144 192 240 288 324 360
Base material thickness hmin= [mm] 126 150 174 228 288 344 384 430
Tensile NRd: single anchor, no edge effects
Non cracked concrete
HIT-V 5.8 [kN] 12,0 19,3 28,0 52,7 82,0 117,5 140,2 164,3
HIT-V 8.8 [kN] 19,3 30,7 44,7 64,0 89,4 117,5 140,2 164,3
HIT-V-R [kN] 13,9 21,9 31,6 58,8 89,4 117,5 80,4 98,3
HIT-V-HCR [kN] 19,3 30,7 44,7 64,0 89,4 117,5 140,2 164,3
Cracked concrete
HIT-V 5.8 [kN] 10,7 16,8 22,6 32,2 50,3 72,4 85,1 96,9
HIT-V 8.8 [kN] 10,7 16,8 22,6 32,2 50,3 72,4 85,1 96,9
HIT-V-R [kN] 10,7 16,8 22,6 32,2 50,3 72,4 80,4 96,9
HIT-V-HCR [kN] 10,7 16,8 22,6 32,2 50,3 72,4 85,1 96,9
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked and cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef,2 = [mm] 96 120 144 192 240 288 324 360
Base material thickness hmin = [mm] 126 150 174 228 288 344 384 430
Edge distance c = cmin= [mm] 40 50 60 80 100 120 135 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 11,6 16,5 21,7 28,6 40,0 52,6 62,7 73,5
HIT-V-R
HIT-V-HCR
Cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 5,8 9,0 12,2 17,5 27,4 37,5 44,7 52,4
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 3,9 5,7 7,8 12,9 18,9 25,9 31,8 38,1
HIT-V-R
HIT-V-HCR
Cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 2,8 4,0 5,5 9,1 13,4 18,4 22,5 27,0
HIT-V-R
HIT-V-HCR

396 10 / 2012
Hilti HIT-RE 500-SD
with HIT-V rod

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef,2 = [mm] 96 120 144 192 240 288 324 360
Base material thickness hmin= [mm] 126 150 174 228 288 344 384 430
Spacing s = smin= [mm] 40 50 60 80 100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non cracked concrete
HIT-V 5.8 [kN] 12,0 19,3 26,5 34,9 48,8 64,2 76,6 89,7
HIT-V 8.8 [kN] 13,4 20,1 26,5 34,9 48,8 64,2 76,6 89,7
HIT-V-R [kN] 13,4 20,1 26,5 34,9 48,8 64,2 76,6 89,7
HIT-V-HCR [kN] 13,4 20,1 26,5 34,9 48,8 64,2 76,6 89,7
Cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN] 7,2 11,0 14,8 20,8 31,7 44,9 52,9 61,1
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
Non cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0
Cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 135,6 154,6
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0

10 / 2012 397
Hilti HIT-RE 500-SD
with HIS-(R)N

Hilti HIT-RE 500-SD with HIS-(R)N


Injection mortar system Benefits

Hilti - suitable for cracked and non-


HIT-RE 500-SD cracked concrete C 20/25 to
330 ml foil pack C 50/60
- high loading capacity
(also available
as 500 ml - suitable for dry and water
and 1400 ml saturated concrete
foil pack) - long working time at elevated
temperatures
Statik mixer - odourless epoxy

HIS-(R)N sleeve

Small edge European


Tensile Fire Corrosion CE
Concrete distance Shock Seismic Technical
zone resistance resistance conformity
and spacing Approval

PROFIS
Anchor
design
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
a)
European technical approval DIBt, Berlin ETA-07/0260 / 2009-01-12
ES report icl. seismic ICC evaluation service ESR 2322 / 2012-02-01
Shockproof fastenings in civil Federal Office for Cicil Protection,
BZS D 08-604 / 2009-10-21
defence installations Bern
Fire test report MFPA, Leipzig GS-III/B-07-070 / 2008-01-18
Assessment report (fire) warringtonfire WF 166402 / 2007-10-26 & suppl.
WF 172920 / 2008-05-27
a) All data given in this section according ETA-07/0260, issue 2009-01-12.

398 10 / 2012
Hilti HIT-RE 500-SD
with HIS-(R)N

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Screw strength class 8.8
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range +5C to +40C

Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended
loads.
Anchor size M8 M10 M12 M16 M20
Embedment depth [mm] 90 110 125 170 205
Base material thickness [mm] 120 150 170 230 270

Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20
Non cracked concrete
Tensile NRu,m HIS-N [kN] 26,3 48,3 70,4 123,9 114,5
Shear VRu,m HIS-N [kN] 13,7 24,2 41,0 62,0 57,8
Cracked concrete
Tensile NRu,m HIS-N [kN] 26,3 48,3 67,1 106,4 114,5
Shear VRu,m HIS-N [kN] 13,7 24,2 41,0 62,0 57,8

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20
Non cracked concrete
Tensile NRk HIS-N [kN] 25,0 46,0 67,0 111,9 109,0
Shear VRk HIS-N [kN] 13,0 23,0 39,0 59,0 55,0
Cracked concrete
Tensile NRk HIS-N [kN] 25,0 40,0 50,3 79,8 105,7
Shear VRk HIS-N [kN] 13,0 23,0 39,0 59,0 55,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20
Non cracked concrete
Tensile NRd HIS-N [kN] 16,8 27,7 33,6 53,3 70,6
Shear VRd HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
Cracked concrete
Tensile NRd HIS-N [kN] 13,9 19,0 24,0 38,0 50,3
Shear VRd HIS-N [kN] 10,4 18,4 26,0 39,3 36,7

10 / 2012 399
Hilti HIT-RE 500-SD
with HIS-(R)N

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20
Non cracked concrete
Tensile Nrec HIS-N [kN] 12,0 19,8 24,0 38,1 50,4
Shear Vrec HIS-N [kN] 7,4 13,1 18,6 28,1 26,2
Cracked concrete
Tensile Nrec HIS-N [kN] 9,9 13,6 17,1 27,1 35,9
Shear Vrec HIS-N [kN] 7,4 13,1 18,6 28,1 26,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-RE 500-SD injection mortar may be applied in the temperature ranges given below. An elevated base
material temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +58 C +35 C +58 C
Temperature range III -40 C to +70 C +43 C +70 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of HIS-(R)N
Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20
HIS-N [N/mm] 490 490 460 460 460
Nominal Screw 8.8 [N/mm] 800 800 800 800 800
tensile
strength fuk HIS-RN [N/mm] 700 700 700 700 700
Screw A4-70 [N/mm] 700 700 700 700 700
HIS-N [N/mm] 410 410 375 375 375
Yield Screw 8.8 [N/mm] 640 640 640 640 640
strength fyk HIS-RN [N/mm] 350 350 350 350 350
Screw A4-70 [N/mm] 450 450 450 450 450
Stressed HIS-(R)N [mm] 51,5 108,0 169,1 256,1 237,6
cross-
section As Screw [mm] 36,6 58 84,3 157 245
Moment of HIS-(R)N [mm] 145 430 840 1595 1543
resistance W Screw [mm] 31,2 62,3 109 277 541

400 10 / 2012
Hilti HIT-RE 500-SD
with HIS-(R)N

Material quality
Part Material
a)
internally threaded sleeves C-steel 1.0718,
HIS-N steel galvanized 5m
b)
internally threaded sleeves
stainless steel 1.4401 and 1.4571
HIS-RN
a)
related fastening screw: strength class 8.8, A5 > 8% Ductile
steel galvanized 5m
b)
related fastening screw: strength class 70, A5 > 8% Ductile
stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362

Anchor dimensions
Anchor size M8 M10 M12 M16 M20
Internal sleeve
M8x90 M10x110 M12x125 M16x170 M20x205
HIS-(R)N
Anchor embedment depth [mm] 90 110 125 170 205

Setting
installation equipment
Anchor size M8 M10 M12 M16 M20
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

10 / 2012 401
Hilti HIT-RE 500-SD
with HIS-(R)N

Setting instruction

Dry and water-saturated concrete, hammer drilling

Brush bore hole with required steel brush HIT-RB


For detailed information on installation see instruction for use given with the package of the product.

Curing time for general conditions


Data according ETA-07/0260, issue 2009-01-12
Temperature Working time in which anchor Curing time before anchor
of the base material can be inserted and adjusted tgel can be fully loaded tcure
40 C 12 min 4h
30 C to 39 C 12 min 8h
20 C to 29 C 20 min 12 h
15 C to 19 C 30 min 24 h
10 C to 14 C 90 min 48 h
5 C to 9 C 120 min 72 h

402 10 / 2012
Hilti HIT-RE 500-SD
with HIS-(R)N

Setting details
Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20
Nominal diameter of
d0 [mm] 14 18 22 28 32
drill bit
Diameter of element d [mm] 12,5 16,5 20,5 25,4 27,6
Effective anchorage
hef [mm] 90 110 125 170 205
and drill hole depth
Minimum base
hmin [mm] 120 150 170 230 270
material thickness
Diameter of clearance
df [mm] 9 12 14 18 22
hole in the fixture
Thread engagement
hs [mm] 8-20 10-25 12-30 16-40 20-50
length; min - max
Minimum spacing smin [mm] 40 45 55 65 90
Minimum edge
cmin [mm] 40 45 55 65 90
distance
Critical spacing for
scr,sp 2 ccr,sp
splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


a) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N 1,5 hef
b)
failure
c)
Torque moment Tmax [Nm] 10 20 40 80 150

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) h: base material thickness (h hmin)
b) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
c) This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.

10 / 2012 403
Hilti HIT-RE 500-SD
with HIS-(R)N

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in
ETA-07/0260, issue 2009-01-12.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20
HIS-N [kN] 17,4 30,7 44,7 80,3 74,1
NRd,s
HIS-RN [kN] 13,9 21,9 31,6 58,8 69,2

404 10 / 2012
Hilti HIT-RE 500-SD
with HIS-(R)N

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20
Embedment depth
90 110 125 170 205
hef [mm]
Non cracked concrete
0
N Rd,p Temperature range I [kN] 22,2 28,6 45,2 81,0 95,2
0
N Rd,p Temperature range II [kN] 19,4 23,8 35,7 66,7 81,0
0
N Rd,p Temperature range III [kN] 11,1 14,3 19,0 35,7 45,2
Cracked concrete
0
N Rd,p Temperature range I [kN] 13,9 19,0 28,6 45,2 54,8
0
N Rd,p Temperature range II [kN] 11,1 16,7 19,0 35,7 45,2
0
N Rd,p Temperature range III [kN] 6,7 9,5 11,9 19,0 23,8

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20
0
N Rd,c Non cracked concrete [kN] 24,0 27,7 33,6 53,3 70,6
0
N Rd,c Cracked concrete [kN] 17,1 19,8 24,0 38,0 50,3
a) Splitting resistance must only be considered for non-cracked concrete

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,1 a)
fB,p = (fck,cube/25N/mm) 1 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = 1

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

10 / 2012 405
Hilti HIT-RE 500-SD
with HIS-(R)N

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


fh,N = 1

Influence of reinforcement
hef [mm] 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a)
0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
VRd,s
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

406 10 / 2012
Hilti HIT-RE 500-SD
with HIS-(R)N

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
0
V Rd,c [kN] 12,4 19,6 28,2 40,2 46,2
Cracked concrete
0
V Rd,c [kN] 8,8 13,9 20,0 28,5 32,7

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

10 / 2012 407
Hilti HIT-RE 500-SD
with HIS-(R)N

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


Anchor size M8 M10 M12 M16 M20
f hef = 1,38 1,21 1,04 1,22 1,45

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

408 10 / 2012
Hilti HIT-RE 500-SD
with HIS-(R)N

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 90 110 125 170 205
Base material thickness hmin= [mm] 120 150 170 230 270
Tensile NRd: single anchor, no edge effects
Non cracked concrete
HIS-N [kN] 17,4 27,7 33,6 53,3 70,6
HIS-RN [kN] 13,9 21,9 31,6 53,3 69,2
Cracked concrete
HIS-(R)N [kN] 13,9 19,0 24,0 38,0 50,3
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked and cracked concrete
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 90 110 125 170 205
Base material thickness hmin= [mm] 120 150 170 230 270
Edge distance c = cmin= [mm] 40 45 55 65 90
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non cracked concrete
HIS-(R)N [kN] 11,0 12,4 15,4 23,5 32,0
Cracked concrete
HIS-(R)N [kN] 7,1 8,9 11,0 16,8 22,8
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non cracked concrete
HIS-(R)N [kN] 4,2 5,5 7,6 10,8 17,2
Cracked concrete
HIS-(R)N [kN] 3,0 3,9 5,4 7,7 12,2

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Data according ETA-07/0260, issue 2009-01-12
Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 90 110 125 170 205
Base material thickness hmin= [mm] 120 150 170 230 270
Spacing s = smin= [mm] 40 45 55 65 90
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non cracked concrete
HIS-(R)N [kN] 13,1 15,2 18,5 29,0 38,8
Cracked concrete
HIS-(R)N [kN] 8,5 10,8 13,2 20,6 27,6
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non cracked and cracked concrete
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

10 / 2012 409
Hilti HIT-RE 500-SD
with rebar

Hilti HIT-RE 500-SD with rebar


Injection mortar system Benefits

Hilti - suitable for non-cracked and


HIT-RE 500-SD cracked concrete
330 ml foil pack C 20/25 to C 50/60
- high loading capacity
(also available
as 500 ml - suitable for dry and water
and 1400 ml saturated concrete
foil pack) - large diameter applications
- high corrosion resistant
Statik mixer - long working time at elevated
temperatures
- odourless epoxy
- embedment depth range:
rebar BSt 500 S from 60 160 mm for 8
to 128 640 mm for 32

PROFIS
Small edge Variable European
Tensile Fire CE Anchor
Concrete distance embedment Seismic Technical
zone resistance conformity design
and spacing depth Approval
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
a)
European technical approval DIBt, Berlin ETA-07/0260 / 2009-01-12
ES report icl. seismic ICC evaluation service ESR 2322 / 2012-02-01
Fire test report MFPA, Leipzig GS-III/B-07-070 / 2008-01-18
Assessment report (fire) warringtonfire WF 166402 / 2007-10-26 & suppl.
WF 172920 / 2008-05-27
a) All data given in this section according ETA-07/0260, issue 2009-01-12.

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range +5C to +40C

410 10 / 2012
Hilti HIT-RE 500-SD
with rebar

Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended
loads.
Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Typical embedment depth [mm] 80 90 110 125 125 170 210 270 300
Base material thickness [mm] 110 120 145 165 165 220 275 340 380
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.

Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500S
Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Non cracked concrete
Tensile NRu,m BSt 500 S [kN] 29,4 45,2 65,1 89,3 94,1 149,2 204,9 298,7 349,9
Shear VRu,m BSt 500 S [kN] 14,7 23,1 32,6 44,1 57,8 90,3 141,8 177,5 232,1
Cracked concrete
Tensile NRu,m BSt 500 S [kN] 23,8 33,5 46,1 57,0 65,2 110,8 146,1 228,7 268,1
Shear VRu,m BSt 500 S [kN] 14,7 23,1 32,6 44,1 57,8 90,3 141,8 177,5 232,1

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Non cracked concrete
Tensile NRk BSt 500 S [kN] 28,0 42,4 58,3 70,6 70,6 111,9 153,7 224,0 262,4
Shear VRk BSt 500 S [kN] 14,0 22,0 31,0 42,0 55,0 86,0 135,0 169,0 221,0
Cracked concrete
Tensile NRk BSt 500 S [kN] 16,1 22,6 31,1 38,5 44,0 74,8 109,6 154,4 181,0
Shear VRk BSt 500 S [kN] 14,0 22,0 31,0 42,0 55,0 86,0 135,0 169,0 221,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Non cracked concrete
Tensile NRd BSt 500 S [kN] 16,8 23,6 32,4 39,2 33,6 53,3 73,2 106,7 125,0
Shear VRd BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3
Cracked concrete
Tensile NRd BSt 500 S [kN] 8,9 12,6 17,3 21,4 20,9 35,6 52,2 73,5 86,2
Shear VRd BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Non cracked concrete
Tensile Nrec BSt 500 S [kN] 12,0 16,8 23,1 28,0 24,0 38,1 52,3 76,2 89,3
Shear Vrec BSt 500 S [kN] 6,7 10,5 14,8 20,0 26,2 41,0 64,3 80,5 105,2
Cracked concrete
Tensile Nrec BSt 500 S [kN] 6,4 9,0 12,3 15,3 15,0 25,4 37,3 52,5 61,5
Shear Vrec BSt 500 S [kN] 6,7 10,5 14,8 20,0 26,2 41,0 64,3 80,5 105,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

10 / 2012 411
Hilti HIT-RE 500-SD
with rebar

Service temperature range


Hilti HIT-RE 500-SD injection mortar may be applied in the temperature ranges given below. An elevated base
material temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +58 C +35 C +58 C
Temperature range III -40 C to +70 C +43 C +70 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of rebar BSt 500S
Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Nominal
tensile BSt 500 S [N/mm] 550 550 550 550 550 550 550 550 550
strength fuk
Yield
BSt 500 S [N/mm] 500 500 500 500 500 500 500 500 500
strength fyk
Stressed
cross- BSt 500 S [mm] 50,3 78,5 113,1 153,9 201,1 314,2 490,9 615,8 804,2
section As
Moment of
resistance BSt 500 S [mm] 50,3 98,2 169,6 269,4 402,1 785,4 1534 2155 3217
W

Material quality
Part Material
rebar Geometry and mechanical properties according to DIN 488-2:1986 or
BSt 500 S E DIN 488-2:2006

Setting
installation equipment
Anchor size 8 10 12 14 16 20 25 28 32
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

412 10 / 2012
Hilti HIT-RE 500-SD
with rebar

Setting instruction

Dry and water-saturated concrete, hammer drilling

Brush bore hole with required steel brush HIT-RB


For detailed information on installation see instruction for use given with the package of the product.

Curing time for general conditions


Data according ETA-07/0260, issue 2009-01-12
Temperature Working time in which anchor Curing time before anchor
of the base material can be inserted and adjusted tgel can be fully loaded tcure
40 C 12 min 4h
30 C to 39 C 12 min 8h
20 C to 29 C 20 min 12 h
15 C to 19 C 30 min 24 h
10 C to 14 C 90 min 48 h
5 C to 9 C 120 min 72 h

10 / 2012 413
Hilti HIT-RE 500-SD
with rebar

Setting details
Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Nominal diameter of
d0 [mm] 12 14 16 18 20 25 32 35 40
drill bit
Effective anchorage hef,min [mm] 60 60 70 75 80 90 100 112 128
and drill hole depth
range
a) hef,max [mm] 160 200 240 280 320 400 500 560 640
Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness 100 mm
Minimum spacing smin [mm] 40 50 60 70 80 100 125 140 160
Minimum edge
cmin [mm] 40 50 60 70 80 100 125 140 160
distance
Critical spacing for
scr,sp 2 ccr,sp
splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


b) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N 1,5 hef
c)
failure

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) hef,min hef hef,max (hef: embedment depth)
b) h: base material thickness (h hmin)
c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in
ETA-07/0260, issue 2009-01-12.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the

414 10 / 2012
Hilti HIT-RE 500-SD
with rebar

exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
NRd,s BSt 500 S [kN] 20,0 30,7 44,3 60,7 79,3 123,6 192,9 242,1 315,7

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Typical embedment depth
80 90 110 125 125 170 210 270 300
hef,typ [mm]
Non cracked concrete
0
N Rd,p Temperature range I [kN] 16,8 23,6 34,6 42,8 41,9 71,2 102,1 147,0 186,7
0
N Rd,p Temperature range II [kN] 13,4 18,8 27,6 36,7 32,9 56,0 86,4 113,1 143,6
0
N Rd,p Temperature range III [kN] 7,8 11,0 16,1 21,4 20,9 33,1 51,1 67,9 86,2
Cracked concrete
0
N Rd,p Temperature range I [kN] 8,9 12,6 17,3 21,4 20,9 35,6 55,0 73,5 86,2
0
N Rd,p Temperature range II [kN] 7,3 10,2 13,8 18,3 18,0 28,0 43,2 56,5 71,8
0
N Rd,p Temperature range III [kN] 4,5 5,5 8,1 10,7 10,5 15,3 23,6 33,9 43,1

10 / 2012 415
Hilti HIT-RE 500-SD
with rebar

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
0
N Rd,c Non cracked concrete [kN] 20,1 24,0 32,4 39,2 33,6 53,3 73,2 106,7 125,0
0
N Rd,c Cracked concrete [kN] 14,3 17,1 23,1 28,0 24,0 38,0 52,2 76,1 89,1
a) Splitting resistance must only be considered for non-cracked concrete

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,1 a)
fB,p = (fck,cube/25N/mm) 1 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hef/hef,typ)

416 10 / 2012
Hilti HIT-RE 500-SD
with rebar

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
VRd,s BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 15,0 18,7 27,0 39,2 47,3 59,0
Cracked concrete
0
V Rd,c [kN] 4,2 6,1 8,2 10,6 13,2 19,2 27,7 33,5 41,8

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

10 / 2012 417
Hilti HIT-RE 500-SD
with rebar

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


hef/d 4 4,5 5 6 7 8 9 10 11
0,05 (hef / d)
1,68
f hef = 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81
hef/d 12 13 14 15 16 17 18 19 20
0,05 (hef / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

418 10 / 2012
Hilti HIT-RE 500-SD
with rebar

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

10 / 2012 419
Hilti HIT-RE 500-SD
with rebar

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,1 = [mm] 60 60 72 84 96 120 150 168 192
Base material thickness hmin= [mm] 100 100 104 120 136 170 214 238 272
Tensile NRd: single anchor, no edge effects
Non cracked concrete
BSt 500 S [kN] 12,6 13,0 17,1 21,6 22,6 31,6 44,2 52,4 64,0
Cracked concrete
BSt 500 S [kN] 6,7 8,4 11,3 14,4 16,1 22,5 31,5 37,3 45,6
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3
Cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 88,2 104,5 127,7

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,1 = [mm] 60 60 72 84 96 120 150 168 192
Base material thickness hmin= [mm] 100 100 104 120 136 170 214 238 272
Edge distance c = cmin= [mm] 40 50 60 70 80 100 125 140 160
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non cracked concrete
BSt 500 S [kN] 7,6 8,5 10,0 12,5 13,1 18,3 25,6 30,3 37,0
Cracked concrete
BSt 500 S [kN] 4,0 5,6 7,6 9,7 10,8 15,2 21,2 25,2 30,7
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non cracked concrete
BSt 500 S [kN] 3,5 4,9 6,7 8,6 10,8 15,7 22,9 27,7 34,6
Cracked concrete
BSt 500 S [kN] 2,5 3,5 4,7 6,1 7,6 11,1 16,2 19,6 24,5

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,1 = [mm] 60 60 72 84 96 120 150 168 192
Base material thickness hmin= [mm] 100 100 104 120 136 170 214 238 272
Spacing s = smin= [mm] 40 50 60 70 80 100 125 140 160
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non cracked concrete
BSt 500 S [kN] 7,8 8,2 10,4 13,0 13,6 19,0 26,6 31,5 38,5
Cracked concrete
BSt 500 S [kN] 4,4 5,5 7,4 9,3 9,7 13,6 19,0 22,5 27,4
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 56,5 79,0 93,7 114,4
Cracked concrete
BSt 500 S [kN] 9,3 12,8 17,3 22,0 28,8 40,3 56,3 66,8 81,6

420 10 / 2012
Hilti HIT-RE 500-SD
with rebar

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,typ = [mm] 80 90 110 125 125 170 210 270 300
Base material thickness hmin= [mm] 110 120 142 161 165 220 274 340 380
Tensile NRd: single anchor, no edge effects
Non cracked concrete
BSt 500 S [kN] 16,8 23,6 32,4 39,2 33,6 53,3 73,2 106,7 125,0
Cracked concrete
BSt 500 S [kN] 8,9 12,6 17,3 21,4 20,9 35,6 52,2 73,5 86,2
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3
cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,typ = [mm] 80 90 110 125 125 170 210 270 300
Base material thickness hmin= [mm] 110 120 142 161 165 220 274 340 380
Edge distance c = cmin= [mm] 40 50 60 70 80 100 125 140 160
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non cracked concrete
BSt 500 S [kN] 9,1 11,6 15,5 18,9 17,0 26,1 36,1 50,4 59,5
Cracked concrete
BSt 500 S [kN] 4,3 6,0 8,4 10,5 10,3 17,4 25,7 35,9 42,4
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non cracked concrete
BSt 500 S [kN] 3,7 5,3 7,3 9,5 11,5 17,2 25,0 31,6 39,3
Cracked concrete
BSt 500 S [kN] 2,6 3,8 5,2 6,7 8,1 12,2 17,7 22,4 27,9

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,typ = [mm] 80 90 110 125 125 170 210 270 300
Base material thickness hmin= [mm] 110 120 142 161 165 220 274 340 380
Spacing s = smin= [mm] 40 50 60 70 80 100 125 140 160
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non cracked concrete
BSt 500 S [kN] 10,4 13,5 18,1 22,0 19,2 30,1 41,4 59,5 69,8
Cracked concrete
BSt 500 S [kN] 5,9 8,1 11,1 13,7 13,2 21,5 29,5 42,4 49,8
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3
Cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 35,6 57,3 87,5 112,7 142,1

10 / 2012 421
Hilti HIT-RE 500-SD
with rebar

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,2 = [mm] 96 120 144 168 192 240 300 336 384
Base material thickness hmin= [mm] 126 150 176 204 232 290 364 406 464
Tensile NRd: single anchor, no edge effects
Non cracked concrete
BSt 500 S [kN] 20,0 30,7 44,3 57,5 64,0 89,4 125,0 148,1 181,0
Cracked concrete
BSt 500 S [kN] 10,7 16,8 22,6 28,7 32,2 50,3 78,5 91,5 110,3
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked and cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,2 = [mm] 96 120 144 168 192 240 300 336 384
Base material thickness hmin= [mm] 126 150 176 204 232 290 364 406 464
Edge distance c = cmin= [mm] 40 50 60 70 80 100 125 140 160
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non cracked concrete
BSt 500 S [kN] 11,0 16,5 21,7 27,3 28,6 40,0 55,9 66,2 80,9
Cracked concrete
BSt 500 S [kN] 5,8 9,1 12,3 15,9 17,8 27,8 44,1 51,4 61,9
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non cracked and cracked concrete
BSt 500 S [kN] 3,9 5,7 7,8 10,2 12,9 18,9 27,8 33,9 42,6
Cracked concrete
BSt 500 S [kN] 2,8 4,0 5,5 7,2 9,1 13,4 19,7 24,0 30,2

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Data according ETA-07/0260, issue 2009-01-12
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,2 = [mm] 96 120 144 168 192 240 300 336 384
Base material thickness hmin= [mm] 126 150 176 204 232 290 364 406 464
Spacing s = smin= [mm] 40 50 60 70 80 100 125 140 160
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non cracked concrete
BSt 500 S [kN] 12,8 19,4 26,5 33,4 34,9 48,8 68,2 80,9 98,8
Cracked concrete
BSt 500 S [kN] 7,2 11,0 14,8 18,9 20,9 31,9 48,6 56,9 68,9
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3
Cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3

422 10 / 2012
Hilti HIT-RE 500-SD
with rebar

10 / 2012 423
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Hilti HIT-RE 500 with HIT-V / HAS


in hammer drilled holes
Injection mortar system Benefits

Hilti - suitable for non-cracked concrete


HIT-RE 500 C 20/25 to C 50/60
330 ml foil pack - high loading capacity
(also available - suitable for dry and water
as 500 ml saturated concrete
and 1400 ml - under water application
foil pack) - large diameter applications
- high corrosion resistant
Statik mixer - long working time at elevated
temperatures
- odourless epoxy
HAS rod - embedment depth range:
from 40 160 mm for M8
to 120 600 mm for M30
HAS-E rod

HIT-V rod

PROFIS
Small edge Variable High European
Fire Corrosion CE Anchor
Concrete distance embedment corrosion Technical
resistance resistance conformity design
and spacing depth resistance Approval
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
European technical approval a) DIBt, Berlin ETA-04/0027 / 2009-05-20
UB 3565 / 4595 / 2006-10-29
Fire test report IBMB, Braunschweig
UB 3588 / 4825 / 2005-11-15
WF 166402 / 2007-10-26 & suppl.
Assessment report (fire) warringtonfire
WF 172920 / 2008-05-27
a) All data given in this section according ETA-04/0027, issue 2009-05-20.

424 10 / 2012
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperature range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range +5C to +40C

Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended
loads.
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Typical embedment depth [mm] 80 90 110 125 170 210 240 270 300 330 360
Base material thickness [mm] 110 120 140 165 220 270 300 340 380 410 450
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.

Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8
Additional Hilti
Data according ETA-04/0027, issue 2008-11-03
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Tensile NRu,m HIT-V 5.8 [kN] 18,9 30,5 44,1 83,0 129,2 185,9 241,5 295,1 364,4 428,9 459,9
Shear VRu,m HIT-V 5.8 [kN] 9,5 15,8 22,1 41,0 64,1 92,4 120,8 147,0 182,2 214,5 256,2

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8


Additional Hilti
Data according ETA-04/0027, issue 2008-11-03
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Tensile NRk HIT-V 5.8 [kN] 18,0 29,0 42,0 70,6 111,9 153,7 187,8 224,0 262,4 302,7 344,9
Shear VRk HIT-V 5.8 [kN] 9,0 15,0 21,0 39,0 61,0 88,0 115,0 140,0 173,5 204,3 244,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8


Additional Hilti
Data according ETA-04/0027, issue 2008-11-03
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Tensile NRd HIT-V 5.8 [kN] 12,0 19,3 27,7 33,6 53,3 73,2 89,4 106,7 125,0 144,2 164,3
Shear VRd HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0 138,8 163,4 195,2

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8
Additional Hilti
Data according ETA-04/0027, issue 2008-11-03
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Tensile Nrec HIT-V 5.8 [kN] 8,6 13,8 19,8 24,0 38,1 52,3 63,9 76,2 89,3 103,0 117,3
Shear Vrec HIT-V 5.8 [kN] 5,1 8,6 12,0 22,3 34,9 50,3 65,7 80,0 99,1 116,7 139,4
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

10 / 2012 425
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Service temperature range


Hilti HIT-RE 500 injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +58 C +35 C +58 C
Temperature range III -40 C to +70 C +43 C +70 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of HIT-V / HAS
Additional Hilti
Data according ETA-04/0027, issue 2008-11-03
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
HIT-V/HAS 5.8 [N/mm] 500 500 500 500 500 500 500 500 500 500 500
Nominal HIT-V/HAS 8.8 [N/mm] 800 800 800 800 800 800 800 800 800 800 800
tensile
strength fuk HIT-V/HAS -R [N/mm] 700 700 700 700 700 700 500 500 500 500 500
HIT-V/HAS -HCR [N/mm] 800 800 800 800 800 700 700 700 500 500 500
HIT-V/HAS 5.8 [N/mm] 400 400 400 400 400 400 400 400 400 400 400
Yield HIT-V/HAS 8.8 [N/mm] 640 640 640 640 640 640 640 640 640 640 640
strength fyk HIT-V/HAS -R [N/mm] 450 450 450 450 450 450 210 210 210 210 210
HIT-V/HAS -HCR [N/mm] 600 600 600 600 600 400 400 400 250 250 250
Stressed HAS [mm] 32,8 52,3 76,2 144 225 324 427 519 647 759 913
cross-
section As HIT-V [mm] 36,6 58,0 84,3 157 245 353 459 561 694 817 976
Moment of HAS [mm] 27,0 54,1 93,8 244 474 809 1274 1706 2321 2949 3891
resistance
W HIT-V [mm] 31,2 62,3 109 277 541 935 1387 1874 2579 3294 4301

426 10 / 2012
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Material quality
Part Material
Threaded rod Strength class 5.8, A5 > 8% ductile
HIT-V(F), steel galvanized 5 m,
HAS 5.8 M8 M24 (F) hot dipped galvanized 45 m,
Threaded rod Strength class 8.8, A5 > 8% ductile
HIT-V(F), steel galvanized 5 m,
HAS 8.8 M27 M39 (F) hot dipped galvanized 45 m,
Stainless steel grade A4, A5 > 8% ductile
Threaded rod
strength class 70 for M24 and class 50 for M27 to M30, 1.4401; 1.4404;
HIT-V-R, HAS-R
1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, 1.4529; 1.4565
Threaded rod
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
HIT-V-HCR, HAS-HCR
M24 to M30: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, hot dipped galvanized
Washer
Stainless steel, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
ISO 7089
High corrosion resistant steel, 1.4529; 1.4565
Strength class 8,
steel galvanized 5 m,
hot dipped galvanized 45 m,
Nut
Strength class 70, stainless steel grade A4,
EN ISO 4032
1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, high corrosion resistant steel,
1.4529; 1.4565

Anchor dimensions
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

Anchor rod
M12x110

M16x125

M20x170

M24x210

M27x240

M30x270

M33x300

M36x330

M39x360
M10x90
M8x80

HAS, HAS-E,
HAS-R, HAS-ER
HAS-HCR

Anchor embedment depth [mm] 80 90 110 125 170 210 240 270 300 330 360
Anchor rod
Anchor rods HIT-V (-R / -HCR) are available in variable length
HIT-V, HIT-V-R, HIT-V-HCR

Setting
installation equipment
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Rotary hammer TE2 TE16 TE40 TE70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser
Additional a)
DD EC-1, DD 100 DD xxx
Hilti recommended tools
a) For anchors in diamond drilled holes load values for combined pull-out and concrete cone resistance have to be
reduced (see section Setting instruction)

10 / 2012 427
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Setting instruction

Dry and water-saturated concrete, hammer drilling

a)

Brush bore hole with required steel brush HIT-RB


a) Note: Manual cleaning only for hef 250 mm and anchor size M16
For detailed information on installation see instruction for use given with the package of the product.

428 10 / 2012
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Water filled bore hole or submerged, hammer drilling

Brush bore hole with required steel brush HIT-RB


For detailed information on installation see instruction for use given with the package of the product.

10 / 2012 429
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Curing time for general conditions


Data according ETA-04/0027, issue 2009-05-20
Temperature Working time in which anchor Curing time before anchor
of the base material can be inserted and adjusted tgel can be fully loaded tcure
40 C 12 min 4h
30 C to 39 C 12 min 8h
20 C to 29 C 20 min 12 h
15 C to 19 C 30 min 24 h
10 C to 14 C 90 min 48 h
5 C to 9 C 120 min 72 h

For dry concrete curing times may be reduced according to the following table.
For installation temperatures below +5 C all load values have to be reduced according to the load
reduction factors given below.

Curing time for dry concrete


Additional Hilti technical data
Temperature Reduced curing time Working time in which
of the before anchor can be anchor can be inserted Load reduction factor
base material fully loaded tcure,dry and adjusted tgel
40 C 4h 12 min 1
30 C 8h 12 min 1
20 C 12 h 20 min 1
15 C 18 h 30 min 1
10 C 24 h 90 min 1
5 C 36 h 120 min 1
0 C 50 h 3h 0,7
-5 C 72 h 4h 0,6

430 10 / 2012
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Setting details
Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Nominal diameter of
d0 [mm] 10 12 14 18 24 28 30 35 37 40 42
drill bit
Effective anchorage hef,min [mm] 40 40 48 64 80 96 108 120 132 144 156
and drill hole depth
range
a) hef,max [mm] 160 200 240 320 400 480 540 600 660 720 780
Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness 100 mm
Diameter of clearance
df [mm] 9 12 14 18 22 26 30 33 36 39 42
hole in the fixture
Minimum spacing smin [mm] 40 50 60 80 100 120 135 150 165 180 195
Minimum edge
cmin [mm] 40 50 60 80 100 120 135 150 165 180 195
distance
Critical spacing for
scr,sp 2 ccr,sp
splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


b) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N 1,5 hef
c)
failure
d)
Torque moment Tmax [Nm] 10 20 40 80 150 200 270 300 330 360 390

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) hef,min hef hef,max (hef: embedment depth)
b) h: base material thickness (h hmin)
c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
d) This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.

10 / 2012 431
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in
ETA-04/0027, issue 2009-05-20.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
HAS 5.8 [kN] 11,3 17,3 25,3 48,0 74,7 106,7 - - - - -
HIT-V 5.8 [kN] 12,0 19,3 28,0 52,7 82,0 118,0 153,3 187,3 231,3 272,3 325,3
HAS 8.8 [kN] - - - - - - 231,3 281,3 345,1 404,8 486,9
HIT-V 8.8 [kN] 19,3 30,7 44,7 84,0 130,7 188,0 244,7 299,3 370,1 435,7 520,5
NRd,s
HAS (-E)-R [kN] 12,3 19,8 28,3 54,0 84,0 119,8 75,9 92,0 113,2 132,8 159,8
HIT-V-R [kN] 13,9 21,9 31,6 58,8 92,0 132,1 80,4 98,3 122,6 144,3 172,4
HAS (-E)-HCR [kN] 18,0 28,0 40,7 76,7 120,0 106,7 144,8 175,7 134,8 158,1 190,2
HIT-V-HCR [kN] 19,3 30,7 44,7 84,0 130,7 117,6 152,9 187,1 144,6 170,2 203,3

432 10 / 2012
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Design combined pull-out and concrete cone resistance for anchors in diamond drilled
holes a)
NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Typical embedment depth
80 90 110 125 170 210 240 270 300 330 360
hef,typ [mm]
0
N Rd,p Temperature range I [kN] 15,3 21,5 31,6 44,9 76,3 105,6 135,7 157,5 171,0 203,3 232,9
0
N Rd,p Temperature range II [kN] 12,4 17,5 25,7 35,9 61,0 82,9 106,6 133,3 136,8 162,6 186,3
0
N Rd,p Temperature range III [kN] 7,7 10,8 15,8 22,4 35,6 52,8 63,0 78,8 82,1 97,6 111,8
a) Additional Hilti technical data (not part of ETA-04/0027, issue 2009-05-20):
The design values for combined pull-out and concrete cone resistance may be increased by 20 % for anchor
installation in dry concrete (concrete not in contact with water before/during installation and curing).

Design concrete cone resistance a) NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp a) = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
0
N Rd,c [kN] 17,2 20,5 27,7 33,6 53,3 73,2 89,4 106,7 125,0 144,2 164,3
a) Additional Hilti technical data (not part of ETA-04/0027, issue 2009-05-20):
The design values for concrete cone and splitting resistance may be increased by 20 % for anchor installation
in dry concrete (concrete not in contact with water before/during installation and curing).

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,1 a)
fB,p = (fck,cube/25N/mm) 1 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

10 / 2012 433
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hef/hef,typ)

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

434 10 / 2012
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Basic design shear resistance

Design steel resistance VRd,s


Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
HAS 5.8 [kN] 6,8 10,4 15,2 28,8 44,8 64,0 - - - - -
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0 138,8 163,4 195,2
HAS 8.8 [kN] - - - - - - 139,2 168,8 207,0 242,9 292,2
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2 222,1 261,4 312,3
VRd,s
HAS (-E)-R [kN] 7,7 12,2 17,3 32,7 50,6 71,8 45,8 55,5 67,9 79,7 95,9
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8 72,9 85,8 102,5
HAS (-E)-HCR [kN] 10,4 16,8 24,8 46,4 72,0 64,0 86,9 105,7 80,9 94,9 114,1
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0 86,8 102,1 122,0

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 18,7 27,0 36,6 44,5 53,0 62,1 71,7 81,9

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

10 / 2012 435
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


hef/d 4 4,5 5 6 7 8 9 10 11
0,05 (hef / d)
1,68
f hef = 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81

hef/d 12 13 14 15 16 17 18 19 20
0,05 (hef / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

436 10 / 2012
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Embedment depth hef,1 = [mm] 48 60 72 96 120 144 162 180 198 216 234
Base material thickness hmin= [mm] 100 100 102 132 168 200 222 250 272 296 324
Tensile NRd: single anchor, no edge effects
HIT-V 5.8
HIT-V 8.8
[kN] 8,0 11,2 14,7 22,6 31,6 41,6 49,6 58,1 67,0 76,3 86,1
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, no edge effects, without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0 138,8 163,4 195,2
HIT-V 8.8 [kN] 11,2 18,4 27,2 50,4 78,4 112,8 138,8 162,6 187,6 213,8 241,0
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8 72,9 85,8 102,5
HIT-V-HCR [kN] 11,2 18,4 27,2 50,4 78,4 70,9 92,0 112,0 86,8 102,1 122,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Embedment depth hef,1 = [mm] 48 60 72 96 120 144 162 180 198 216 234
Base material thickness hmin= [mm] 100 100 102 132 168 200 222 250 272 296 324
Edge distance c = cmin= [mm] 40 50 60 80 100 120 135 150 165 180 195
Tensile NRd: single anchor, min. edge distance (c = cmin)
HIT-V 5.8
HIT-V 8.8
[kN] 5,4 7,3 8,5 12,9 18,2 23,8 28,2 33,2 38,1 43,4 49,2
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
HIT-V 5.8
HIT-V 8.8
[kN] 3,4 4,9 6,7 10,8 15,7 21,4 26,0 31,1 36,5 42,2 48,3
HIT-V-R
HIT-V-HCR

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Embedment depth hef,1 = [mm] 48 60 72 96 120 144 162 180 198 216 234
Base material thickness hmin= [mm] 100 100 102 132 168 200 222 250 272 296 324
Spacing s = smin= [mm] 40 50 60 80 100 120 135 150 165 180 195
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
HIT-V 8.8
[kN] 5,1 7,0 8,8 13,5 19,0 24,9 29,6 34,8 40,1 45,6 51,5
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 88,7 103,9 119,9 136,6 154,0
HIT-V 8.8 [kN] 7,2 18,4 26,3 40,5 56,5 74,3 88,7 103,9 119,9 136,6 154,0
HIT-V-R [kN] 7,2 12,8 19,2 35,3 55,1 74,3 48,3 58,8 72,9 85,8 102,5
HIT-V-HCR [kN] 7,2 18,4 26,3 40,5 56,5 70,9 88,7 103,9 86,8 102,1 122,0

10 / 2012 437
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Embedment depth hef,typ = [mm] 80 90 110 125 170 210 240 270 300 330 360
Base material thickness hmin= [mm] 110 120 140 161 218 266 300 340 374 410 450
Tensile NRd: single anchor, no edge effects
HIT-V 5.8 [kN] 12,0 19,3 27,7 33,6 53,3 73,2 89,4 106,7 125,0 144,2 164,3
HIT-V 8.8 [kN] 15,3 20,5 27,7 33,6 53,3 73,2 89,4 106,7 125,0 144,2 164,3
HIT-V-R [kN] 13,9 20,5 27,7 33,6 53,3 73,2 80,4 98,3 122,6 144,2 164,3
HIT-V-HCR [kN] 15,3 20,5 27,7 33,6 53,3 73,2 89,4 106,7 125,0 144,2 164,3
Shear VRd: single anchor, no edge effects, without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0 138,8 163,4 195,2
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2 222,1 261,4 312,3
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8 72,9 85,8 102,5
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0 86,8 102,1 122,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Embedment depth hef,typ = [mm] 80 90 110 125 170 210 240 270 300 330 360
Base material thickness hmin= [mm] 110 120 140 161 218 266 300 340 374 410 450
Edge distance c = cmin= [mm] 40 50 60 80 100 120 135 150 165 180 195
Tensile NRd: single anchor, min. edge distance (c = cmin)
HIT-V 5.8
HIT-V 8.8
[kN] 8,2 10,0 13,3 16,9 26,1 35,6 43,3 51,4 60,0 69,1 78,6
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
HIT-V 5.8
HIT-V 8.8
[kN] 3,7 5,3 7,3 11,5 17,2 23,6 29,0 34,8 41,1 47,8 54,9
HIT-V-R
HIT-V-HCR

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Embedment depth hef,typ = [mm] 80 90 110 125 170 210 240 270 300 330 360
Base material thickness hmin= [mm] 110 120 140 161 218 266 300 340 374 410 450
Spacing s = smin= [mm] 40 50 60 80 100 120 135 150 165 180 195
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
HIT-V 8.8
[kN] 9,3 11,6 15,5 19,2 30,1 41,2 50,3 59,9 70,1 80,8 92,0
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0 138,8 163,4 195,2
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 177,0 207,0 238,5 271,5
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8 72,9 85,8 102,5
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0 86,8 102,1 122,0

438 10 / 2012
Hilti HIT-RE 500
with HIT-V / HAS
in hammer drilled holes

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Embedment depth hef,2 = [mm] 96 120 144 192 240 288 324 360 396 432 468
Base material thickness hmin= [mm] 126 150 174 228 288 344 384 430 470 512 558
Tensile NRd: single anchor, no edge effects
HIT-V 5.8 [kN] 12,0 19,3 28,0 52,7 82,0 117,5 140,2 164,3 189,5 215,9 243,5
HIT-V 8.8 [kN] 18,4 28,7 41,4 64,0 89,4 117,5 140,2 164,3 189,5 215,9 243,5
HIT-V-R [kN] 13,9 21,9 31,6 58,8 89,4 117,5 80,4 98,3 122,6 144,3 172,4
HIT-V-HCR [kN] 18,4 28,7 41,4 64,0 89,4 117,5 140,2 164,3 144,6 170,2 203,3
Shear VRd: single anchor, no edge effects, without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0 138,8 163,4 195,2
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2 222,1 261,4 312,3
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8 72,9 85,8 102,5
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0 86,8 102,1 122,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Embedment depth hef,2 = [mm] 96 120 144 192 240 288 324 360 396 432 468
Base material thickness hmin= [mm] 126 150 174 228 288 344 384 430 470 512 558
Edge distance c = cmin= [mm] 40 50 60 80 100 120 135 150 165 180 195
Tensile NRd: single anchor, min. edge distance (c = cmin)
HIT-V 5.8
HIT-V 8.8
[kN] 9,9 14,1 18,6 28,6 40,0 52,6 62,7 73,5 84,8 96,6 108,9
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
HIT-V 5.8
HIT-V 8.8
[kN] 3,9 5,7 7,8 12,9 18,9 25,9 31,8 38,1 45,0 52,3 60,0
HIT-V-R
HIT-V-HCR

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Embedment depth hef,2 = [mm] 96 120 144 192 240 288 324 360 396 432 468
Base material thickness hmin= [mm] 126 150 174 228 288 344 384 430 470 512 558
Spacing s = smin= [mm] 40 50 60 80 100 120 135 150 165 180 195
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
HIT-V 8.8
[kN] 11,5 17,3 22,7 34,9 48,8 64,2 76,6 89,7 103,5 117,9 133,0
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0 138,8 163,4 195,2
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2 222,1 261,4 312,3
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8 72,9 85,8 102,5
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0 86,8 102,1 122,0

10 / 2012 439
Hilti HIT-RE 500
with HIT-V / HAS
in diamond drilled holes

Hilti HIT-RE 500 with HIT-V / HAS


in diamond drilled holes
Injection mortar system Benefits

Hilti - suitable for non-cracked concrete


HIT-RE 500 C 20/25 to C 50/60
330 ml foil pack - high loading capacity
(also available - suitable for dry and water
as 500 ml saturated concrete
and 1400 ml - large diameter applications
foil pack) - high corrosion resistant
- long working time at elevated
Statik mixer temperatures
- odourless epoxy
- embedment depth range:
HAS rod from 40 160 mm for M8
to 120 600 mm for M30

HAS-E rod

HIT-V rod

PROFIS
Small edge Variable High Diamond
Corrosion Anchor
Concrete distance embedment corrosion drilled
resistance design
and spacing depth resistance holes
software

Basic loading data for a single anchor


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperature range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range +5C to +40C

440 10 / 2012
Hilti HIT-RE 500
with HIT-V / HAS
in diamond drilled holes

Embedment depth a) and base material thickness for the basic loading data. Mean
ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth [mm] 80 90 110 125 170 210 240 270
Base material thickness [mm] 110 120 140 165 220 270 300 340
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.

Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Tensile NRu,m HIT-V 5.8 [kN] 18,9 30,5 44,1 83,0 129,2 185,9 229,7 287,2
Shear VRu,m HIT-V 5.8 [kN] 9,5 15,8 22,1 41,0 64,1 92,4 120,8 147,0

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Tensile NRk HIT-V 5.8 [kN] 18,0 29,0 42,0 66,0 101,5 142,5 173,0 216,3
Shear VRk HIT-V 5.8 [kN] 9,0 15,0 21,0 39,0 61,0 88,0 115,0 140,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Tensile NRd HIT-V 5.8 [kN] 12,0 18,8 27,6 31,4 48,3 67,9 82,4 103,0
Shear VRd HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Tensile Nrec HIT-V 5.8 [kN] 8,6 13,5 19,7 22,4 34,5 48,5 58,9 73,6
Shear Vrec HIT-V 5.8 [kN] 5,1 8,6 12,0 22,3 34,9 50,3 65,7 80,0
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-RE 500 injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +58 C +35 C +58 C
Temperature range III -40 C to +70 C +43 C +70 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

10 / 2012 441
Hilti HIT-RE 500
with HIT-V / HAS
in diamond drilled holes

Materials
Mechanical properties of HIT-V / HAS
Hilti technical data
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HIT-V/HAS 5.8 [N/mm] 500 500 500 500 500 500 500 500
Nominal HIT-V/HAS 8.8 [N/mm] 800 800 800 800 800 800 800 800
tensile
strength fuk HIT-V/HAS -R [N/mm] 700 700 700 700 700 700 500 500
HIT-V/HAS -HCR [N/mm] 800 800 800 800 800 700 700 700
HIT-V/HAS 5.8 [N/mm] 400 400 400 400 400 400 400 400
Yield HIT-V/HAS 8.8 [N/mm] 640 640 640 640 640 640 640 640
strength fyk HIT-V/HAS -R [N/mm] 450 450 450 450 450 450 210 210
HIT-V/HAS -HCR [N/mm] 600 600 600 600 600 400 400 400
Stressed HAS [mm] 32,8 52,3 76,2 144 225 324 427 519
cross-
section As HIT-V [mm] 36,6 58,0 84,3 157 245 353 459 561
Moment of HAS [mm] 27,0 54,1 93,8 244 474 809 1274 1706
resistance
W HIT-V [mm] 31,2 62,3 109 277 541 935 1387 1874

Material quality
Part Material
Threaded rod HIT-V(F), Strength class 5.8, A5 > 8% ductile, steel galvanized 5 m,
HAS 5.8 M8 M24 (F) hot dipped galvanized 45 m,
Threaded rod HIT-V(F), Strength class 8.8, A5 > 8% ductile, steel galvanized 5 m,
HAS 8.8 M27 M30 (F) hot dipped galvanized 45 m,
Stainless steel grade A4, A5 > 8% ductile, strength class 70 for M24 and
Threaded rod HIT-V-R, HAS-R
class 50 for M27 to M30, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, 1.4529; 1.4565,
Threaded rod HIT-V-HCR,
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
HAS-HCR
M24 to M30: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, hot dipped galvanized
Washer
Stainless steel, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
ISO 7089
High corrosion resistant steel, 1.4529; 1.4565
Strength class 8, steel galvanized 5 m, hot dipped galvanized 45 m,
Strength class 70, stainless steel grade A4, 1.4401; 1.4404; 1.4578;
Nut
1.4571; 1.4439; 1.4362
EN ISO 4032
Strength class 70, high corrosion resistant steel,
1.4529; 1.4565

Anchor dimensions
Anchor size M8 M10 M12 M16 M20 M24 M27 M30

Anchor rod
M12x110

M16x125

M20x170

M24x210

M27x240

M30x270
M10x90
M8x80

HAS, HAS-E,
HAS-R, HAS-ER
HAS-HCR

Anchor embedment depth [mm] 80 90 110 125 170 210 240 270
Anchor rod
Anchor rods HIT-V (-R / -HCR) are available in variable length
HIT-V, HIT-V-R, HIT-V-HCR

442 10 / 2012
Hilti HIT-RE 500
with HIT-V / HAS
in diamond drilled holes

Setting
installation equipment
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Drilling tools DD EC-1, DD 100 DD xxx
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

Setting instruction

Dry and water-saturated concrete, diamond coring drilling; Hilti technical information only

Brush bore hole with required steel brush HIT-RB


For detailed information on installation see instruction for use given with the package of the product.
Important! Remove all water from the borehole and blow out with oil free compressed air until borehole is
completely dried before mortar injection (not applicable to hammer drilled hole in underwater application).
10 / 2012 443
Hilti HIT-RE 500
with HIT-V / HAS
in diamond drilled holes

Curing time for general conditions


Temperature Curing time before anchor can be Working time in which anchor can
of the base material fully loaded tcure be inserted and adjusted tgel
40 C 4h 12 min
30 C to 39 C 8h 12 min
20 C to 29 C 12 h 20 min
15 C to 19 C 24 h 30min
10 C to 14 C 48 h 90 min
5 C to 9 C 72 h 120 min

Setting details
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Nominal diameter of
d0 [mm] 10 12 14 18 24 28 30 35
drill bit
Effective anchorage hef,min [mm] 40 40 48 64 80 96 108 120
and drill hole depth
range
a) hef,max [mm] 160 200 240 320 400 480 540 600
Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness 100 mm
Diameter of clearance
df [mm] 9 12 14 18 22 26 30 33
hole in the fixture
Minimum spacing smin [mm] 40 50 60 80 100 120 135 150
Minimum edge
cmin [mm] 40 50 60 80 100 120 135 150
distance
Critical spacing for
scr,sp 2 ccr,sp
splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


b) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N 1,5 hef
c)
failure
d)
Torque moment Tmax [Nm] 10 20 40 80 150 200 270 300

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.

444 10 / 2012
Hilti HIT-RE 500
with HIT-V / HAS
in diamond drilled holes

a) hef,min hef hef,max (hef: embedment depth)


b) h: base material thickness (h hmin)
c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
d) This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.

Simplified design method


Simplified version of the design method according ETAG 001, TR 029.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then conservative: They will be lower than the exact
values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design software
PROFIS Anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

10 / 2012 445
Hilti HIT-RE 500
with HIT-V / HAS
in diamond drilled holes

Basic design tensile resistance

Design steel resistance NRd,s


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HAS 5.8 [kN] 11,3 17,3 25,3 48,0 74,7 106,7 - -
HIT-V 5.8 [kN] 12,0 19,3 28,0 52,7 82,0 118,0 153,3 187,3
HAS 8.8 [kN] - - - - - - 231,3 281,3
HIT-V 8.8 [kN] 19,3 30,7 44,7 84,0 130,7 188,0 244,7 299,3
NRd,s
HAS (-E)-R [kN] 12,3 19,8 28,3 54,0 84,0 119,8 75,9 92,0
HIT-V-R [kN] 13,9 21,9 31,6 58,8 92,0 132,1 80,4 98,3
HAS (-E)-HCR [kN] 18,0 28,0 40,7 76,7 120,0 106,7 144,8 175,7
HIT-V-HCR [kN] 19,3 30,7 44,7 84,0 130,7 117,6 152,9 187,1

Design combined pull-out and concrete cone resistance for anchors in diamond drilled
holes
NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth
80 90 110 125 170 210 240 270
hef,typ [mm]
0
N Rd,p Temperature range I [kN] 13,4 18,8 27,6 31,4 48,3 67,9 82,4 103,0
0
N Rd,p Temperature range II [kN] 10,9 15,3 22,4 25,4 39,1 55,0 66,7 83,4
0
N Rd,p Temperature range III [kN] 6,8 9,6 14,0 15,9 24,5 34,4 41,8 52,3

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
0
N Rd,c [kN] 17,2 20,5 27,7 33,6 53,3 73,2 89,4 106,7

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,1 a)
fB,p = (fck,cube/25N/mm) 1 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

446 10 / 2012
Hilti HIT-RE 500
with HIT-V / HAS
in diamond drilled holes

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hef/hef,typ)

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

10 / 2012 447
Hilti HIT-RE 500
with HIT-V / HAS
in diamond drilled holes

Basic design shear resistance

Design steel resistance VRd,s


Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HAS 5.8 [kN] 6,8 10,4 15,2 28,8 44,8 64,0 - -
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HAS 8.8 [kN] - - - - - - 139,2 168,8
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
VRd,s
HAS (-E)-R [kN] 7,7 12,2 17,3 32,7 50,6 71,8 45,8 55,5
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HAS (-E)-HCR [kN] 10,4 16,8 24,8 46,4 72,0 64,0 86,9 105,7
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 18,7 27,0 36,6 44,5 53,0

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

448 10 / 2012
Hilti HIT-RE 500
with HIT-V / HAS
in diamond drilled holes

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


hef/d 4 4,5 5 6 7 8 9 10 11
0,05 (hef / d)
1,68
f hef = 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81

hef/d 12 13 14 15 16 17 18 19 20
0,05 (hef / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

10 / 2012 449
Hilti HIT-RE 500
with HIS-(R)N

Hilti HIT-RE 500 with HIS-(R)N


Injection mortar system Benefits

Hilti - suitable for non-cracked concrete


HIT-RE 500 C 20/25 to C 50/60
330 ml foil pack - high loading capacity
(also available - suitable for dry and water
as 500 ml saturated concrete
and 1400 ml - under water application for
foil pack) hammer drilled holes
- long working time at elevated
temperatures
Statik mixer
- odourless epoxy

HIS-(R)N sleeve

PROFIS
Small edge European Diamond
Fire Corrosion CE Anchor
Concrete distance Technical drilled
resistance resistance conformity design
and spacing Approval holes
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
a)
European technical approval DIBt, Berlin ETA-04/0027 / 2009-05-20
UB 3565 / 4595 / 2006-10-29
Fire test report IBMB, Brunswick
UB 3588 / 4825 / 2005-11-15
WF 166402 / 2007-10-26 & suppl.
Assessment report (fire) warringtonfire
WF 172920 / 2008-05-27
a) All data given in this section according ETA-04/0027, issue 2009-05-20.

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Screw strength class 8.8
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range +5C to +40C

450 10 / 2012
Hilti HIT-RE 500
with HIS-(R)N

Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended
loads.
Anchor size M8 M10 M12 M16 M20
Embedment depth [mm] 90 110 125 170 205
Base material thickness [mm] 120 150 170 230 270

Mean ultimate resistance a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N
Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20
Tensile NRu,m HIS-N [kN] 26,3 48,3 70,4 123,9 114,5
Shear VRu,m HIS-N [kN] 13,7 24,2 41,0 62,0 57,8

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N


Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20
Tensile NRk HIS-N [kN] 25,0 46,0 67,0 111,9 109,0
Shear VRk HIS-N [kN] 13,0 23,0 39,0 59,0 55,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N


Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20
Tensile NRd HIS-N [kN] 16,8 27,7 33,6 53,3 70,6
Shear VRd HIS-N [kN] 10,4 18,4 26,0 39,3 36,7

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N


Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20
Tensile Nrec HIS-N [kN] 12,0 19,8 24,0 38,1 50,4
Shear Vrec HIS-N [kN] 7,4 13,1 18,6 28,1 26,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-RE 500 injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.
Maximum long term Maximum short term
Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +58 C +35 C +58 C
Temperature range III -40 C to +70 C +43 C +70 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

10 / 2012 451
Hilti HIT-RE 500
with HIS-(R)N

Materials
Mechanical properties of HIS-(R)N
Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20
HIS-N [N/mm] 490 490 460 460 460
Nominal Screw 8.8 [N/mm] 800 800 800 800 800
tensile
strength fuk HIS-RN [N/mm] 700 700 700 700 700
Screw A4-70 [N/mm] 700 700 700 700 700
HIS-N [N/mm] 410 410 375 375 375
Yield Screw 8.8 [N/mm] 640 640 640 640 640
strength fyk HIS-RN [N/mm] 350 350 350 350 350
Screw A4-70 [N/mm] 450 450 450 450 450
Stressed HIS-(R)N [mm] 51,5 108,0 169,1 256,1 237,6
cross-
section As Screw [mm] 36,6 58 84,3 157 245
Moment of HIS-(R)N [mm] 145 430 840 1595 1543
resistance W Screw [mm] 31,2 62,3 109 277 541

Material quality
Part Material
a)
internally threaded sleeves C-steel 1.0718,
HIS-N steel galvanized 5m
b)
internally threaded sleeves
stainless steel 1.4401 and 1.4571
HIS-RN
a) related fastening screw: strength class 8.8, A5 > 8% Ductile
steel galvanized 5m
b) related fastening screw: strength class 70, A5 > 8% Ductile
stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362

Anchor dimensions
Anchor size M8 M10 M12 M16 M20
Internal sleeve
M8x90 M10x110 M12x125 M16x170 M20x205
HIS-(R)N
Anchor embedment depth [mm] 90 110 125 170 205

Setting
installation equipment
Anchor size M8 M10 M12 M16 M20
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser
Additional a)
DD EC-1, DD 100 DD xxx
Hilti recommended tools
a) For anchors in diamond drilled holes load values for combined pull-out and concrete cone resistance have to be
reduced (see section Setting instruction)

452 10 / 2012
Hilti HIT-RE 500
with HIS-(R)N

Setting instruction

Dry and water-saturated concrete, hammer drilling

a)

a) Note: Manual cleaning for HIS-(R)N M8 and HIS-(R)N M10 only!


Brush bore hole with required steel brush HIT-RB
For detailed information on installation see instruction for use given with the package of the product.

10 / 2012 453
Hilti HIT-RE 500
with HIS-(R)N

Water filled bore hole or submerged, hammer drilling

Brush bore hole with required steel brush HIT-RB


For detailed information on installation see instruction for use given with the package of the product.

454 10 / 2012
Hilti HIT-RE 500
with HIS-(R)N

Dry and water-saturated concrete, diamond coring drilling; Hilti technical information only

For anchors in diamond drilled holes load values for combined pull-out and
concrete cone resistance have to be reduced. Load reduction factor: 0.7
Brush bore hole with required steel brush HIT-RB
For detailed information on installation see instruction for use given with the package of the product.
Important! Remove all water from the borehole and blow out with oil free compressed air until borehole is
completely dried before mortar injection (not applicable to hammer drilled hole in underwater application).

10 / 2012 455
Hilti HIT-RE 500
with HIS-(R)N

Curing time for general conditions


Data according ETA-04/0027, issue 2009-05-20
Temperature Working time in which anchor Curing time before anchor
of the base material can be inserted and adjusted tgel can be fully loaded tcure
40 C 12 min 4h
30 C to 39 C 12 min 8h
20 C to 29 C 20 min 12 h
15 C to 19 C 30 min 24 h
10 C to 14 C 90 min 48 h
5 C to 9 C 120 min 72 h

For dry concrete curing times may be reduced according to the following table.
For installation temperatures below +5 C all load values have to be reduced according to the load
reduction factors given below.

Curing time for dry concrete


Additional Hilti technical data
Temperature Reduced curing time Working time in which
of the before anchor can be anchor can be inserted Load reduction factor
base material fully loaded tcure,dry and adjusted tgel
40 C 4h 12 min 1
30 C 8h 12 min 1
20 C 12 h 20 min 1
15 C 18 h 30 min 1
10 C 24 h 90 min 1
5 C 36 h 120 min 1
0 C 50 h 3h 0,7
-5 C 72 h 4h 0,6

456 10 / 2012
Hilti HIT-RE 500
with HIS-(R)N

Setting details
Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20
Nominal diameter of
d0 [mm] 14 18 22 28 32
drill bit
Diameter of element d [mm] 12,5 16,5 20,5 25,4 27,6
Effective anchorage
hef [mm] 90 110 125 170 205
and drill hole depth
Minimum base
hmin [mm] 120 150 170 230 270
material thickness
Diameter of clearance
df [mm] 9 12 14 18 22
hole in the fixture
Thread engagement
hs [mm] 8-20 10-25 12-30 16-40 20-50
length; min - max
Minimum spacing smin [mm] 40 45 55 65 90
Minimum edge
cmin [mm] 40 45 55 65 90
distance
Critical spacing for
scr,sp 2 ccr,sp
splitting failure
1,0 hef for h / hef 2,0

Critical edge distance


a) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N 1,5 hef
c)
failure
c)
Torque moment Tmax [Nm] 10 20 40 80 150

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) h: base material thickness (h hmin)
b) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
c) This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.

10 / 2012 457
Hilti HIT-RE 500
with HIS-(R)N

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in
ETA-04/0027, issue 2009-05-20.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20
HIS-N [kN] 16,8 30,7 44,7 80,3 74,1
NRd,s
HIS-RN [kN] 13,9 21,9 31,6 58,8 69,2

Design combined pull-out and concrete cone resistance a)


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20
Embedment depth
90 110 125 170 205
hef [mm]
0
N Rd,p Temperature range I [kN] 19,0 28,6 45,2 81,0 95,2
0
N Rd,p Temperature range II [kN] 16,7 23,8 35,7 66,7 81,0
0
N Rd,p Temperature range III [kN] 9,5 14,3 19,0 35,7 45,2
a) Additional Hilti technical data (not part of ETA-04/0027, issue 2009-05-20):
The design values for combined pull-out and concrete cone resistance may be increased by 20 % for anchor
installation in dry concrete (concrete not in contact with water before/during installation and curing).

458 10 / 2012
Hilti HIT-RE 500
with HIS-(R)N

Design concrete cone resistance a) NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp a) = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20
0
N Rd,c [kN] 20,5 27,7 33,6 53,3 70,6
a) Additional Hilti technical data (not part of ETA-04/0027, issue 2009-05-20):
The design values for concrete cone and splitting resistance may be increased by 20 % for anchor installation
in dry concrete (concrete not in contact with water before/during installation and curing).

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,1 a)
fB,p = (fck,cube/25N/mm) 1 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = 1

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


fh,N = 1

10 / 2012 459
Hilti HIT-RE 500
with HIS-(R)N

Influence of reinforcement
hef [mm] 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a)
0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
VRd,s
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
0
V Rd,c [kN] 12,4 19,6 28,2 40,2 46,2

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

460 10 / 2012
Hilti HIT-RE 500
with HIS-(R)N

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and
the minimum edge distance cmin.

Influence of embedment depth


Anchor size M8 M10 M12 M16 M20
f hef = 1,38 1,21 1,04 1,22 1,45

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

10 / 2012 461
Hilti HIT-RE 500
with HIS-(R)N

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 90 110 125 170 205
Base material thickness hmin= [mm] 120 150 170 230 270
Tensile NRd: single anchor, no edge effects
HIS-N [kN] 16,8 27,7 33,6 53,3 70,6
HIS-RN [kN] 13,9 21,9 31,6 53,3 69,2
Shear VRd: single anchor, no edge effects, without lever arm
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 90 110 125 170 205
Base material thickness hmin= [mm] 120 150 170 230 270
Edge distance c = cmin= [mm] 40 45 55 65 90
Tensile NRd: single anchor, min. edge distance (c = cmin)

HIS-(R)N [kN] 9,4 12,4 15,4 23,5 32,0

Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm

HIS-(R)N [kN] 4,2 5,5 7,6 10,8 17,2

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Data according ETA-04/0027, issue 2009-05-20
Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 90 110 125 170 205
Base material thickness hmin= [mm] 120 150 170 230 270
Spacing s = smin= [mm] 40 45 55 65 90
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)

HIS-(R)N [kN] 11,2 15,2 18,5 29,0 38,8

Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

462 10 / 2012
Hilti HIT-RE 500
with HIS-(R)N

10 / 2012 463
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Hilti HIT-RE 500 with rebar in hammer drilled holes


Injection mortar system Benefits

Hilti - suitable for non-cracked concrete


HIT-RE 500 C 20/25 to C 50/60
330 ml foil pack - high loading capacity
(also available - suitable for dry and water
as 500 ml saturated concrete
and 1400 ml - under water application
foil pack) - large diameter applications
- long working time at elevated
Statik mixer temperatures
- odourless epoxy
- embedment depth range:
rebar BSt 500 S from 60 160 mm for 8
to 128 640 mm for 32

PROFIS
Small edge Variable European
CE Anchor
Concrete distance embedment Technical
conformity design
and spacing depth Approval
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
a)
European technical approval DIBt, Berlin ETA-04/0027 / 2009-05-20
a) All data given in this section according ETA-04/0027, issue 2009-05-20.

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range +5C to +40C

464 10 / 2012
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Embedment depth a) and base material thickness for the basic loading data. Mean
ultimate resistance, characteristic resistance, design resistance, recommended loads.
Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Typical embedment depth [mm] 80 90 110 125 125 170 210 270 300 330 360
Base material thickness [mm] 110 120 145 165 165 220 275 340 380 420 470
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.

Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500S
Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Tensile NRu,m BSt 500 S [kN] 29,4 45,2 65,1 89,3 94,1 149,2 204,9 298,7 349,9 403,6 459,9
Shear VRu,m BSt 500 S [kN] 14,7 23,1 32,6 44,1 57,8 90,3 141,8 177,5 232,1 293,9 362,9

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Tensile NRk BSt 500 S [kN] 28,0 42,4 58,3 70,6 70,6 111,9 153,7 224,0 262,4 302,7 344,9
Shear VRk BSt 500 S [kN] 14,0 22,0 31,0 42,0 55,0 86,0 135,0 169,0 221,0 279,9 345,6

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Tensile NRd BSt 500 S [kN] 14,4 20,2 27,7 33,6 33,6 53,3 73,2 106,7 125,0 144,2 164,3
Shear VRd BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3 186,6 230,4

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Tensile Nrec BSt 500 S [kN] 10,3 14,4 19,8 24,0 24,0 38,1 52,3 76,2 89,3 103,0 117,3
Shear Vrec BSt 500 S [kN] 6,7 10,5 14,8 20,0 26,2 41,0 64,3 80,5 105,2 133,3 164,6
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

10 / 2012 465
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Service temperature range


Hilti HIT-RE 500 injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +58 C +35 C +58 C
Temperature range III -40 C to +70 C +43 C +70 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of rebar BSt 500S
Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Nominal
tensile BSt 500 S [N/mm] 550 550 550 550 550 550 550 550 550 550 550
strength fuk
Yield
BSt 500 S [N/mm] 500 500 500 500 500 500 500 500 500 500 500
strength fyk
Stressed
cross- BSt 500 S [mm] 50,3 78,5 113,1 153,9 201,1 314,2 490,9 615,8 804,2 1018 1257
section As
Moment of
resistance BSt 500 S [mm] 50,3 98,2 169,6 269,4 402,1 785,4 1534 2155 3217 4580 6283
W

Material quality
Part Material
rebar Geometry and mechanical properties according to DIN 488-2:1986 or
BSt 500 S E DIN 488-2:2006

Setting
installation equipment
Anchor size 8 10 12 14 16 20 25 28 32 36
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

466 10 / 2012
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Setting instruction

Dry and water-saturated concrete, hammer drilling

a)

a) Note: Manual cleaning only for hef 250 mm and anchor size d 16mm
Brush bore hole with required steel brush HIT-RB
For detailed information on installation see instruction for use given with the package of the product.

10 / 2012 467
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Water filled bore hole or submerged, hammer drilling

Brush bore hole with required steel brush HIT-RB


For detailed information on installation see instruction for use given with the package of the product.

468 10 / 2012
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Curing time for general conditions


Additional
Data according ETA-04/0027, issue 2009-05-20
Hilti technical data
Temperature Working time in which Curing time before Preparation work may
of the base material anchor anchor continue.
can be inserted and can be fully loaded tcure Do not apply design load.
adjusted tgel tcure, ini
40 C 12 min 4h 2h
30 C to 39 C 12 min 8h 4h
20 C to 29 C 20 min 12 h 6h
15 C to 19 C 30 min 24 h 8h
10 C to 14 C 90 min 48 h 12 h
5 C to 9 C 120 min 72 h 18 h

For dry concrete curing times may be reduced according to the following table.
For installation temperatures below +5 C all load values have to be reduced according to the load
reduction factors given below.

Curing time for dry concrete


Additional Hilti technical data
Temperature Reduced curing time Working time in which
of the before anchor can be anchor can be inserted Load reduction factor
base material fully loaded tcure,dry and adjusted tgel
40 C 4h 12 min 1
30 C 8h 12 min 1
20 C 12 h 20 min 1
15 C 18 h 30 min 1
10 C 24 h 90 min 1
5 C 36 h 120 min 1
0 C 50 h 3h 0,7
-5 C 72 h 4h 0,6

10 / 2012 469
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Setting details
Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Nominal diameter of
d0 [mm] 12 14 16 18 20 25 32 35 40 45 55
drill bit
Effective anchorage hef,min [mm] 60 60 70 75 80 90 100 112 128 144 160
and drill hole depth
range
a) hef,max [mm] 160 200 240 280 320 400 500 560 640 720 800
Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness 100 mm
Minimum spacing smin [mm] 40 50 60 70 80 100 125 140 160 180 200
Minimum edge
cmin [mm] 40 50 60 70 80 100 125 140 160 180 200
distance
Critical spacing for
scr,sp 2 ccr,sp
splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


b) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N 1,5 hef
c)
failure

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) hef,min hef hef,max (hef: embedment depth)
b) h: base material thickness (h hmin)
c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in
ETA-04/0027, issue 2009-05-20.
Influence of concrete strength
Influence of edge distance
Influence of spacing

470 10 / 2012
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
NRd,s BSt 500 S [kN] 20,0 30,7 44,3 60,7 79,3 123,6 192,9 242,1 315,7 400 494

Design combined pull-out and concrete cone resistance a)


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Typical embedment depth
80 90 110 125 125 170 210 270 300 330 360
hef,typ [mm]
0
N Rd,p Temperature range I [kN] 14,4 20,2 29,6 36,7 41,9 71,2 102,1 147,0 186,7 192,8 216,1
0
N Rd,p Temperature range II [kN] 11,5 16,2 23,7 31,4 32,9 56,0 86,4 113,1 143,6 154,2 172,9
0
N Rd,p Temperature range III [kN] 6,7 9,4 13,8 18,3 20,9 33,1 51,1 67,9 86,2 92,5 103,7
a) Additional Hilti technical data (not part of ETA-04/0027, issue 2009-05-20):
The design values for combined pull-out and concrete cone resistance may be increased by 20 % for anchor
installation in dry concrete (concrete not in contact with water before/during installation and curing).

10 / 2012 471
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Design concrete cone resistance a) NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp a) = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
0
N Rd,c [kN] 17,2 20,5 27,7 33,6 33,6 53,3 73,2 106,7 125,0 144,2 164,3
a) Additional Hilti technical data (not part of ETA-04/0027, issue 2009-05-20):
The design values for concrete cone and splitting resistance may be increased by 20 % for anchor installation
in dry concrete (concrete not in contact with water before/during installation and curing).

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,1 a)
fB,p = (fck,cube/25N/mm) 1 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

472 10 / 2012
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hef/hef,typ)

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s

- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c


fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Additional
Hilti
Data according ETA-04/0027, issue 2009-05-20
technical
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
VRd,s BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3 186,6 230,4

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size 8 10 12 14 16 20 25 28 32 36 40
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 15,0 18,7 27,0 39,2 47,3 59,0 71,7 85,5

10 / 2012 473
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

474 10 / 2012
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Influence of embedment depth


hef/d 4 4,5 5 6 7 8 9 10 11
0,05 (hef / d)
1,68
f hef = 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81
hef/d 12 13 14 15 16 17 18 19 20
0,05 (hef / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

10 / 2012 475
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Embedment depth hef,1 = [mm] 60 60 72 84 96 120 150 168 192 216 240
Base material thickness hmin= [mm] 100 100 104 120 136 170 214 238 272 306 350
Tensile NRd: single anchor, no edge effects

BSt 500 S [kN] 10,8 11,2 14,7 18,5 22,6 31,6 44,2 52,4 64,0 76,3 89,4

Shear VRd: single anchor, no edge effects, without lever arm

BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3 186,6 230,4

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Embedment depth hef,1 = [mm] 60 60 72 84 96 120 150 168 192 216 240
Base material thickness hmin= [mm] 100 100 104 120 136 170 214 238 272 306 350
Edge distance c = cmin= [mm] 40 50 60 70 80 100 125 140 160 180 200
Tensile NRd: single anchor, min. edge distance (c = cmin)

BSt 500 S [kN] 6,5 7,3 8,6 10,8 13,1 18,3 25,6 30,3 37,0 44,1 52,5

Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm

BSt 500 S [kN] 3,5 4,9 6,7 8,6 10,8 15,7 22,9 27,7 34,6 42,2 50,4

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Embedment depth hef,1 = [mm] 60 60 72 84 96 120 150 168 192 216 240
Base material thickness hmin= [mm] 100 100 104 120 136 170 214 238 272 306 350
Spacing s = smin= [mm] 40 50 60 70 80 100 125 140 160 180 200
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)

BSt 500 S [kN] 6,7 7,0 8,9 11,2 13,6 19,0 26,6 31,5 38,5 45,9 54,1

Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm

BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 56,5 79,0 93,7 114,4 136,6 159,9

476 10 / 2012
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Embedment depth hef,typ = [mm] 80 90 110 125 125 170 210 270 300 330 360
Base material thickness hmin= [mm] 110 120 142 161 165 220 274 340 380 420 470
Tensile NRd: single anchor, no edge effects

BSt 500 S [kN] 14,4 20,2 27,7 33,6 33,6 53,3 73,2 106,7 125,0 144,2 164,3

Shear VRd: single anchor, no edge effects, without lever arm

BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3 186,6 230,4

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Embedment depth hef,typ = [mm] 80 90 110 125 125 170 210 270 300 330 360
Base material thickness hmin= [mm] 110 120 142 161 165 220 274 340 380 420 470
Edge distance c = cmin= [mm] 40 50 60 70 80 100 125 140 160 180 200
Tensile NRd: single anchor, min. edge distance (c = cmin)

BSt 500 S [kN] 7,8 10,0 13,3 16,2 17,0 26,1 36,1 50,4 59,5 69,1 79,3

Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm

BSt 500 S [kN] 3,7 5,3 7,3 9,5 11,5 17,2 25,0 31,6 39,3 47,8 56,9

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Embedment depth hef,typ = [mm] 80 90 110 125 125 170 210 270 300 330 360
Base material thickness hmin= [mm] 110 120 142 161 165 220 274 340 380 420 470
Spacing s = smin= [mm] 40 50 60 70 80 100 125 140 160 180 200
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)

BSt 500 S [kN] 8,9 11,6 15,5 18,9 19,2 30,1 41,4 59,5 69,8 80,8 92,3

Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm

BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3 186,6 230,4

10 / 2012 477
Hilti HIT-RE 500
with rebar
in hammer drilled holes

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Embedment depth hef,2 = [mm] 96 120 144 168 192 240 300 336 384 432 480
Base material thickness hmin= [mm] 126 150 176 204 232 290 364 406 464 522 590
Tensile NRd: single anchor, no edge effects

BSt 500 S [kN] 17,2 26,9 38,8 49,3 64,0 89,4 125,0 148,1 181,0 215,9 252,9

Shear VRd: single anchor, no edge effects, without lever arm

BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3 186,6 230,4

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Embedment depth hef,2 = [mm] 96 120 144 168 192 240 300 336 384 432 480
Base material thickness hmin= [mm] 126 150 176 204 232 290 364 406 464 522 590
Edge distance c = cmin= [mm] 40 50 60 70 80 100 125 140 160 180 200
Tensile NRd: single anchor, min. edge distance (c = cmin)

BSt 500 S [kN] 9,4 14,1 18,6 23,4 28,6 40,0 55,9 66,2 80,9 96,6 113,1

Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm

BSt 500 S [kN] 3,9 5,7 7,8 10,2 12,9 18,9 27,8 33,9 42,6 52,3 62,7

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Additional
Data according ETA-04/0027, issue 2009-05-20 Hilti tech.
data
Anchor size 8 10 12 14 16 20 25 28 32 36 40
Embedment depth hef,2 = [mm] 96 120 144 168 192 240 300 336 384 432 480
Base material thickness hmin= [mm] 126 150 176 204 232 290 364 406 464 522 590
Spacing s = smin= [mm] 40 50 60 70 80 100 125 140 160 180 200
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)

BSt 500 S [kN] 10,9 16,6 22,7 28,6 34,9 48,8 68,2 80,9 98,8 117,9 138,1

Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm

BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3 186,6 230,4

478 10 / 2012
Hilti HIT-RE 500
with rebar
in hammer drilled holes

10 / 2012 479
Hilti HIT-RE 500
with rebar
in diamond drilled holes

Hilti HIT-RE 500 with rebar in diamond drilled holes


Injection mortar system Benefits

Hilti - suitable for non-cracked concrete


HIT-RE 500 C 20/25 to C 50/60
330 ml foil pack - high loading capacity
(also available - suitable for dry and water
as 500 ml saturated concrete
and 1400 ml -- large diameter applications
foil pack) - long working time at elevated
temperatures
Statik mixer - odourless epoxy
- embedment depth range:
from 60 160 mm for 8
rebar BSt 500 S to 128 640 mm for 32

PROFIS
Small edge Variable Diamond
Anchor
Concrete distance embedment drilled
design
and spacing depth holes
software

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range +5C to +40C

Embedment depth a) and base material thickness for the basic loading data. Mean
ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size 8 10 12 14 16 20 25 28 32
Typical embedment depth [mm] 80 90 110 125 125 170 210 270 300
Base material thickness [mm] 110 120 145 165 165 220 275 340 380
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.

480 10 / 2012
Hilti HIT-RE 500
with rebar
in diamond drilled holes

Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500S
Anchor size 8 10 12 14 16 20 25 28 32
Tensile NRu,m BSt 500 S [kN] 29,4 45,0 65,1 83,9 87,6 134,7 197,1 268,0 320,3
Shear VRu,m BSt 500 S [kN] 14,7 23,1 32,6 44,1 57,8 90,3 141,8 177,5 232,1

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Anchor size 8 10 12 14 16 20 25 28 32
Tensile NRk BSt 500 S [kN] 24,1 33,9 49,8 63,2 66,0 101,5 148,4 201,9 241,3
Shear VRk BSt 500 S [kN] 14,0 22,0 31,0 42,0 55,0 86,0 135,0 169,0 221,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Anchor size 8 10 12 14 16 20 25 28 32
Tensile NRd BSt 500 S [kN] 13,4 18,8 27,6 30,1 31,4 48,3 70,7 96,1 114,9
Shear VRd BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Anchor size 8 10 12 14 16 20 25 28 32
Tensile Nrec BSt 500 S [kN] 9,6 13,5 19,7 21,5 22,4 34,5 50,5 68,7 82,1
Shear Vrec BSt 500 S [kN] 6,7 10,5 14,8 20,0 26,2 41,0 64,3 80,5 105,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-RE 500 injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +58 C +35 C +58 C
Temperature range III -40 C to +70 C +43 C +70 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

10 / 2012 481
Hilti HIT-RE 500
with rebar
in diamond drilled holes

Materials
Mechanical properties of rebar BSt 500S
Anchor size 8 10 12 14 16 20 25 28 32
Nominal
tensile BSt 500 S [N/mm] 550 550 550 550 550 550 550 550 550
strength fuk
Yield
BSt 500 S [N/mm] 500 500 500 500 500 500 500 500 500
strength fyk
Stressed
cross- BSt 500 S [mm] 50,3 78,5 113,1 153,9 201,1 314,2 490,9 615,8 804,2
section As

Moment of
BSt 500 S [mm] 50,3 98,2 169,6 269,4 402,1 785,4 1534 2155 3217
resistance W

Material quality
Part Material
rebar Geometry and mechanical properties according to DIN 488-2:1986 or
BSt 500 S E DIN 488-2:2006

Setting
installation equipment
Anchor size 8 10 12 14 16 20 25 28 32
Drilling tools DD EC-1, DD 100 DD xxx
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

482 10 / 2012
Hilti HIT-RE 500
with rebar
in diamond drilled holes

Setting instruction

Dry and water-saturated concrete, diamond coring drilling; Hilti technical information only

Brush bore hole with required steel brush HIT-RB


For detailed information on installation see instruction for use given with the package of the product.
Important! Remove all water from the borehole and blow out with oil free compressed air until borehole is
completely dried before mortar injection (not applicable to hammer drilled hole in underwater application).

10 / 2012 483
Hilti HIT-RE 500
with rebar
in diamond drilled holes

Curing time for general conditions


Temperature Working time in which Curing time before Preparation work may
of the base material anchor anchor continue.
can be inserted and can be fully loaded tcure Do not apply design load.
adjusted tgel tcure, ini
40 C 12 min 4h 2h
30 C to 39 C 12 min 8h 4h
20 C to 29 C 20 min 12 h 6h
15 C to 19 C 30 min 24 h 8h
10 C to 14 C 90 min 48 h 12 h
5 C to 9 C 120 min 72 h 18 h

Setting details
Anchor size 8 10 12 14 16 20 25 28 32
Nominal diameter of
d0 [mm] 12 14 16 18 20 25 32 35 40
drill bit
Effective anchorage hef,min [mm] 60 60 70 75 80 90 100 112 128
and drill hole depth
range
a) hef,max [mm] 160 200 240 280 320 400 500 560 640
Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness 100 mm
Minimum spacing smin [mm] 40 50 60 70 80 100 125 140 160
Minimum edge
cmin [mm] 40 50 60 70 80 100 125 140 160
distance
Critical spacing for
scr,sp 2 ccr,sp
splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


b) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3:
for splitting failure

2,26 hef for h / hef 1,3:

Critical spacing for


scr,N 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N 1,5 hef
c)
failure

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) hef,min hef hef,max (hef: embedment depth)
b) h: base material thickness (h hmin)
c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.

484 10 / 2012
Hilti HIT-RE 500
with rebar
in diamond drilled holes

Simplified design method


Simplified version of the design method according ETAG 001, TR 029.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Anchor size 8 10 12 14 16 20 25 28 32
NRd,s BSt 500 S [kN] 20,0 30,7 44,3 60,7 79,3 123,6 192,9 242,1 315,7

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Anchor size 8 10 12 14 16 20 25 28 32
Typical embedment depth
80 90 110 125 125 170 210 270 300
hef,typ [mm]
0
N Rd,p Temperature range I [kN] 13,4 18,8 27,6 30,1 31,4 48,3 70,7 96,1 114,9
0
N Rd,p Temperature range II [kN] 10,9 15,3 22,4 24,4 25,4 39,1 57,3 77,9 93,1
0
N Rd,p Temperature range III [kN] 6,8 9,6 14,0 15,3 15,9 24,5 35,9 48,8 58,3

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size 8 10 12 14 16 20 25 28 32
0
N Rd,c [kN] 17,2 20,5 27,7 33,6 33,6 53,3 73,2 106,7 125,0

10 / 2012 485
Hilti HIT-RE 500
with rebar
in diamond drilled holes

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,1 a)
fB,p = (fck,cube/25N/mm) 1 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hef/hef,typ)

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.

486 10 / 2012
Hilti HIT-RE 500
with rebar
in diamond drilled holes

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Anchor size 8 10 12 14 16 20 25 28 32
VRd,s BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size 8 10 12 14 16 20 25 28 32 36 40
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 15,0 18,7 27,0 39,2 47,3 59,0 71,7 85,5

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

10 / 2012 487
Hilti HIT-RE 500
with rebar
in diamond drilled holes

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


hef/d 4 4,5 5 6 7 8 9 10 11
0,05 (hef / d)
1,68
f hef = 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81

hef/d 12 13 14 15 16 17 18 19 20
0,05 (hef / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

488 10 / 2012
Hilti HIT-RE 500
with rebar
in diamond drilled holes

10 / 2012 489
Hilti HIT-HY 200
with HIT-Z

Hilti HIT-HY 200 with HIT-Z


Injection mortar system Benefits
- No cleaning required: Zero
Hilti HIT- succeptability to borehole
HY 200-A cleaning conditions with dry and
500 ml foil pack water saturated concrete base
(also available material
as 330 ml
- Maximum load performance in
foil pack)
cracked concrete and uncracked
concrete
Hilti HIT-
HY 200-R - Suitable for cracked and non-
500 ml foil pack cracked concrete C 20/25 to
(also available C 50/60
as 330 ml - Suitable for use with diamond
foil pack) cored holes in non-cracked or
cracked concrete with no load
reductions
Static mixer
- Two mortar (Hilti HIT-HY 200-A
and Hilti HIT-HY 200-R) versions
available with different curing
HIT-Z times and same performance
HIT-Z-R rod

No cleaning PROFIS
European
Tensile Fire Corrosion CE required for Anchor
Concrete Technical
zone resistance resistance conformity approved design
Approval
loads software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
a)
European technical approval DIBt, Berlin ETA-12/0006 / 2012-04-04
(HIT-HY 200-A)
ETA-12/0028 / 2012-04-04
(HIT-HY 200-R)
Fire test report IBMB, Brunswick 3501/676/13 / 2012-08-03
a) All data given in this section according ETA-12/0006 and ETA-12/0028, issue 2012-04-04.

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- Embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range +5C to +40C
490 10 / 2012
Hilti HIT-HY 200
with HIT-Z

Embedment depth and base material thickness for the basic loading data. Mean ultimate
resistance, characteristic resistance, design resistance, recommended loads.
Anchor size M8 M10 M12 M16 M20
Typical embedment depth [mm] 70 90 110 145 180
Base material thickness [mm] 130 150 170 245 280

Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, element HIT-Z


Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
Tensile NRu,m HIT-Z [kN] 25,2 39,9 57,8 100,8 153,3
Shear VRu,m HIT-Z [kN] 12,6 20,0 28,4 50,4 76,7
Cracked concrete
Tensile NRu,m HIT-Z [kN] 25,2 39,9 55,1 83,4 115,4
Shear VRu,m HIT-Z [kN] 12,6 20,0 28,4 50,4 76,7

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, element HIT-Z


Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
Tensile NRk HIT-Z [kN] 24,0 38,0 54,3 88,2 122,0
Shear VRk HIT-Z [kN] 12,0 19,0 27,0 48,0 73,0
Cracked concrete
Tensile NRk HIT-Z [kN] 21,1 30,7 41,5 62,9 86,9
Shear VRk HIT-Z [kN] 12,0 19,0 27,0 48,0 73,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, element HIT-Z


Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
Tensile NRd HIT-Z [kN] 16,0 25,3 36,2 58,8 81,3
Shear VRd HIT-Z [kN] 9,6 15,2 21,6 38,4 58,4
Cracked concrete
Tensile NRd HIT-Z [kN] 14,1 20,5 27,7 41,9 58,0
Shear VRd HIT-Z [kN] 9,6 15,2 21,6 38,4 58,4

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, element HIT-Z


Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
Tensile Nrec HIT-Z [kN] 11,4 18,1 25,9 42,0 58,1
Shear Vrec HIT-Z [kN] 6,9 10,9 15,4 27,4 41,7
Cracked concrete
Tensile Nrec HIT-Z [kN] 10,0 14,6 19,8 29,9 41,4
Shear Vrec HIT-Z [kN] 6,9 10,9 15,4 27,4 41,7
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

10 / 2012 491
Hilti HIT-HY 200
with HIT-Z

Service temperature range


Hilti HIT-HY 200 injection mortar with anchor rod HIT-Z may be applied in the temperature ranges given below. An
elevated base material temperature leads to a reduction of the design bond resistance.
Maximum long term Maximum short term
Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +80 C +40 C +80 C
Temperature range III -40 C to +120 C +72 C +120 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of HIT-Z and HIT-Z-R
Anchor size M8 M10 M12 M16 M20
Nominal HIT-Z
tensile [N/mm] 650 650 650 610 595
strength fuk HIT-Z-R
Yield HIT-Z
[N/mm] 520 520 520 490 480
strength fyk HIT-Z-R
Stressed
cross-
HIT-Z [mm] 36,6 58,0 84,3 157 245
section of
thread As
Moment of
HIT-Z [mm] 31,9 62,5 109,7 278 542
resistance W

Material quality
Part Material
HIT-Z C-steel cold formed, steel galvanized 5m
HIT-Z-R stainless steel cold formed, A4

492 10 / 2012
Hilti HIT-HY 200
with HIT-Z

Anchor dimensions
Anchor size M8 M10 M12 M16 M20
min l [mm] 80 95 105 155 215
Length of anchor
max l [mm] 120 160 196 240 250

Helix length lHelix [mm] 50 60 60 96 100

l Helix Marking

head
d marking

Installation equipment
Anchor size M8 M10 M12 M16 M20
Rotary hammer TE 2 TE 40 TE 40 - TE 70

Curing and working time


Temperature HIT-HY 200-R
of the Working time in which anchor Curing time before anchor
base material can be inserted and adjusted twork can be loaded tcure
5 C 1 hour 3 hour
6 C to 10 C 40 min 2 hour
11 C to 20 C 15 min 1 hour
21 C to 30 C 9 min 1 hour
31 C to 40 C 6 min 1 hour

Curing and working time


Temperature HIT-HY 200-A
of the Working time in which anchor Curing time before anchor
base material can be inserted and adjusted twork can be loaded tcure
5 C 25 min 2 hour
6 C to 10 C 15 min 1 hour
11 C to 20 C 7 min 30 min
21 C to 30 C 4 min 30 min
31 C to 40 C 3 min 30 min

10 / 2012 493
Hilti HIT-HY 200
with HIT-Z

Setting instruction

Bore hole drilling


Pre-setting: Drill hole to the required drilling depth with a hammer drill set
in rotation-hammer mode using an appropriately sized carbide drill bit.
Diamond coring is permissible when diamond core drilling machine and the
corresponding core bit are used.

Through-setting: Drill hole through the clearance hole in the fixture to the
required drilling depth with a hammer drill set in rotation-hammer mode
using an appropriately sized carbide drill bit.
Diamond coring is permissible when diamond core drilling machine and the
corresponding core bit are used.

Bore hole cleaninga)

a) No cleaning required for hammer drilled boreholes

b) Hole flushing and evacuation for wet-drilled diamond cored holes or flooded holes
Flush 2 times from the back of the hole over the hole length.

Blow 2 times the hole with oil-free compressed air (min. 6 bar at 6 m/h) to
evacuate the water

Check of setting depth and compress of the drilling dust


Mark the element and check the setting depth and compress the drilling
dust. The element has to fit in the hole until the required embedment
depth.
If it is not possible to compress the dust, remove the dust in the drill hole or
drill deeper.

a) When drilling downward with non-cleaning the required drilling depths can vary due to accumulation of dust in
the hole.

494 10 / 2012
Hilti HIT-HY 200
with HIT-Z

Injection preparation
Tightly attach new Hilti mixing nozzle HIT-RE-M to foil pack manifold (snug
fit). Do not modify the mixing nozzle. Observe the instruction for use of the
dispenser.
Check foil pack holder for proper function. Do not use damaged foil packs /
holders. Swing foil pack holder with foil pack into HIT-dispenser.
Discard initial adhesive. The foil pack opens automatically as dispensing is
initiated. Depending on the size of the foil pack an initial amount of
adhesive has to be discarded.
Discard quantities are
2 strokes for 330 ml foil pack
3 strokes for 500 ml foil pack

Inject adhesive from the back of the borehole without forming air voids
Inject the adhesive starting at the back of the hole, slowly withdrawing the
mixer with each trigger pull.

Fill holes approximately 2/3 full for Pre-setting and 100% full for through-
setting, or as required to ensure that the annular gap between the anchor
and the concrete is completely filled with adhesive along the embedment
length.

After injection is completed, depressurize the dispenser by pressing the


release trigger. This will prevent further adhesive discharge from the mixer.

10 / 2012 495
Hilti HIT-HY 200
with HIT-Z

Overhead installation
For overhead installation the injection is only possible with the aid of
extensions and piston plugs. Assemble HIT-RE-M mixer, extension(s) and
appropriately piston plug HIT-SZ. Insert piston plug to back of the hole and
inject adhesive. During injection the piston plug will be naturally extruded
out of the bore hole by the adhesive pressure

Setting the element


Before use, verify that the element is dry and free of oil and other
contaminants. Set element to the required embedment depth until working
time twork has elapsed.
After setting the element the annular gap between the anchor and the
fixture (through-setting) or concrete (pre-setting) has to be completely filled
with mortar.

After required curing time tcure remove excess mortar.


Apply indicated torque moment to activate anchor functioning principles.
The anchor can be loaded.

For detailed information on installation see instruction for use given with the package of the product.

Setting details
Anchor size M8 M10 M12 M16 M20
Nominal diameter of
d0 [mm] 10 12 14 18 22
drill bit

Effective embedment hnom,min [mm] 60 60 60 96 100


depth range hnom,max [mm] 100 120 150 200 220
Minimum base
hmin [mm] hnom + 60 mm hnom + 100 mm
material thickness
Pre-setting:
Diameter of clearance df [mm] 9 12 14 18 22
hole in the fixture
Through-setting:
Diameter of clearance df [mm] 11 14 16 20 24
hole in the fixture
Torque moment Tinst [Nm] 10 25 40 80 150

496 10 / 2012
Hilti HIT-HY 200
with HIT-Z

Critical edge distance and critical spacing


Critical spacing
scr,sp [mm] 2 ccr,sp
for splitting failure

1,5 hnom for h / hnom 2,35

Critical edge distance 6,2 hnom - 2,0 h


ccr,sp [mm]
for splitting failure for 2,35 > h / hnom > 1,35

3,5 hnom for h / hnom 1,35

Critical spacing for


scr,N [mm] 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N [mm] 1,5 hnom
failure

For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.

a) Embedment depth range: hnom,min hnom hnom,max


Pre-setting: Through-setting:
Install anchor before Install anchor through positioned
positioning fixture fixture

df df

Effective anchorage depth hnom


Hole depth h0
Fixture
Thickness of concrete member h Thickness tfix annular gap
filled with Hilti
HIT-HY 200

10 / 2012 497
Hilti HIT-HY 200
with HIT-Z

Minimum edge distance and spacing


For the calculation of minimum spacing and minimum edge distance of anchors in combination with different embedment
depth and thickness of concrete member the following equation shall be fulfilled:
Ai,req < Ai,cal
Required interaction area Ai,req
Anchor size M8 M10 M12 M16 M20
Cracked concrete [mm] 19200 40800 58800 94700 148000
Uncracked concrete [mm] 22200 57400 80800 128000 198000

Calculate interaction area Ai,cal

Member thickness h hnom +1,5c

Single anchor and


[mm] Ai,cal = (6c) (hnom + 1,5c) with c 5d
group of anchors with s > 3c
Group of anchors with s 3c [mm] Ai,cal = (3c + s) (hnom + 1,5c) with c 5d and s 5d

Member thickness h hnom +1,5c

Single anchor and


[mm] Ai,cal = (6c) h with c 5d
group of anchors with s > 3c
Group of anchors with s 3c [mm] Ai,cal = (3c + s) h with c 5d and s 5d

498 10 / 2012
Hilti HIT-HY 200
with HIT-Z

Best case minimum edge distance and spacing


with required member thickness and embedment depth
Anchor size M8 M10 M12 M16 M20

Cracked concrete
Member thickness h [mm] 140 200 240 300 370
Embedment depth hnom [mm] 80 120 150 200 220
Minimum spacing smin [mm] 40 50 60 80 100
Corresponding edge
c [mm] 40 55 65 80 100
distance
Minimum edge
cmin = [mm] 40 50 60 80 100
distance
Corresponding spacing s [mm] 40 60 65 80 100

Non cracked concrete


Member thickness h [mm] 140 230 270 340 410
Embedment depth hnom [mm] 80 120 150 200 220
Minimum spacing smin [mm] 40 50 60 80 100
Corresponding edge
c [mm] 40 70 80 100 130
distance
Minimum edge
cmin [mm] 40 50 60 80 100
distance
Corresponding spacing s [mm] 40 145 160 160 235

Best case minimum member thickness and embedment depth


with required minimum edge distance and spacing
Anchor size M8 M10 M12 M16 M20

Cracked concrete
Member thickness hmin [mm] 120 120 120 196 200
Embedment depth hnom,min [mm] 60 60 60 96 100
Minimum spacing smin [mm] 40 50 60 80 100
Corresponding edge
c [mm] 40 100 140 135 215
distance
Minimum edge
cmin = [mm] 40 60 90 80 125
distance
Corresponding spacing s [mm] 40 160 220 235 365

Non cracked concrete


Member thickness hmin [mm] 120 120 120 196 200
Embedment depth hnom,min [mm] 60 60 60 96 100
Minimum spacing smin [mm] 40 50 60 80 100
Corresponding edge
c [mm] 50 145 200 190 300
distance
Minimum edge
cmin [mm] 40 80 115 110 165
distance
Corresponding spacing s [mm] 65 240 330 310 495

10 / 2012 499
Hilti HIT-HY 200
with HIT-Z

Minimum edge distance and spacing Explanation

Minimum edge and spacing geometrical requirements are determined by testing the installation conditions in which
two anchors with a given spacing can be set close to an edge without forming a crack in the concrete due to
tightening torque.

The HIT-Z boundary conditions for edge and spacing geometry can be found in the tables to the left. If the
embedment depth and slab thickness are equal to or greater than the values in the table, then the edge and
spacing values may be utilized.

PROFIS Anchor software is programmed to calculate the referenced equations in order to determine the
optimized related minimum edge and spacing based on the following variables:

Cracked or uncracked concrete For cracked concrete it is assumed that a reinforcement is present which
limits the crack width to 0,3 mm, allowing smaller values for minimum edge
distance and minimum spacing

Anchor diameter For smaller anchor diameter a smaller installation torque is required,
allowing smaller values for minimum edge distance and minimum spacing

Slab thickness and embedment Increasing these values allows smaller values for minimum edge distance
depth and minimum spacing

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in
ETA-12/0006 (HIT-HY 200-A) and ETA-12/0028 (HIT-HY 200-R) issued on 2012-04-04
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The simplified calculated design loads take a conservative approach: They will be
lower than the exact values according to ETAG 001, TR 029. For an optimized design, anchor calculation
can be performed using PROFIS anchor design software.
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

TENSION loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p
fB f1,N f2,N f3,N fh,N fre,N
0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

500 10 / 2012
Hilti HIT-HY 200
with HIT-Z

Basic design tensile resistance

Design steel resistance NRd,s


Anchor size M8 M10 M12 M16 M20
NRd,s HIT-Z / HIT-Z-R [kN] 16,0 25,3 36,7 64,0 97,3

Design combined pull-out and concrete cone resistance NRd,p a)


Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
0
N Rd,p Temperature range I [kN] 20,1 30,2 36,2 77,2 100,5
0
N Rd,p Temperature range II [kN] 18,4 27,6 33,2 70,8 92,2
0
N Rd,p Temperature range III [kN] 16,8 25,1 30,2 64,3 83,8
Cracked concrete
0
N Rd,p Temperature range I [kN] 18,4 27,6 33,2 70,8 92,2
0
N Rd,p Temperature range II [kN] 16,8 25,1 30,2 64,3 83,8
0
N Rd,p Temperature range III [kN] 15,1 22,6 27,1 57,9 75,4
a) The combined pull-out and concrete cone resistance is independent from the embedment depth.

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size M8 M10 M12 M16 M20
hnom,typ [mm] 70 90 110 145 180
0
N Rd,c Non cracked concrete [kN] 19,7 28,7 38,8 58,8 81,3
0
N Rd,c Cracked concrete [kN] 14,1 20,5 27,7 41,9 58,0
a) Splitting resistance must only be considered for non-cracked concrete.

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
fB,p = 1,00 1,00 1,00 1,00 1,00 1,00 1,00

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,5 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N 1
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp 1

f2,N = 0,5(1 + c/ccr,N) 1


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp) 1
a) The edge distance shall not be smaller than the minimum edge distance cmin. These influencing factors must
be considered for every edge distance smaller than the critical edge distance.

10 / 2012 501
Hilti HIT-HY 200
with HIT-Z

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N) 1
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp) 1
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin. This influencing factor must be
considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hnom/hnom,typ)

Influence of reinforcement
hnom [mm] 60 70 80 90 100
fre,N = 0,5 + hnom/200mm 1
a) a) a) a)
0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.

SHEAR loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s

- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c


fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Anchor size M8 M10 M12 M16 M20
VRd,s HIT-Z [kN] 9,6 15,2 21,6 38,4 58,4
VRd,s HIT-Z-R [kN] 11,2 18,4 26,4 45,6 70,4

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance a) VRd,c = V0Rd,c fB f f h f4


Non-cracked concrete Cracked concrete
Anchor size M8 M10 M12 M16 M20 M8 M10 M12 M16 M20
0
V Rd,c [kN] 5,8 8,6 11,6 18,9 27,4 4,1 6,0 8,2 13,3 19,4
a) For anchor groups only the anchors close to the edge must be considered.

502 10 / 2012
Hilti HIT-HY 200
with HIT-Z

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hnom)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hnom
c/hnom
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

10 / 2012 503
Hilti HIT-HY 200
with HIT-Z

Influence of embedment depth


hnom/d 4 4,5 5 6 7 8 9 10 11
0,05 (hnom / d)
1,68
f hef = 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81
hef/d 12 13 14 15 16 17 18 19 20
0,05 (hnom / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined TENSION and SHEAR loading


For combined tension and shear loading see section Anchor Design.

Precalculated values design resistance values


All data applies to:
- temperature range I (see service temperature range)
- no effects of dense reinforcement

Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Anchor size M8 M10 M12 M16 M20
Embedment depth hnom,min = [mm] 60 60 60 96 100
Base material thickness hmin= [mm] 120 120 120 196 200
Tensile NRd: single anchor, no edge effects
Non-cracked concrete
HIT-Z / HIT-Z-R [kN] 15,6 15,6 15,6 31,7 33,7
Cracked concrete
HIT-Z / HIT-Z-R [kN] 11,2 11,2 11,2 22,6 24,0
Shear VRd: single anchor, no edge effects, without lever arm
Non-cracked concrete
HIT-Z [kN] 9,6 15,2 21,6 38,4 58,4
HIT-Z-R [kN] 11,2 18,4 26,4 45,6 67,3
Cracked concrete
HIT-Z [kN] 9,6 15,2 21,6 38,4 48,0
HIT-Z-R [kN] 11,2 18,4 22,3 45,1 48,0

504 10 / 2012
Hilti HIT-HY 200
with HIT-Z

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Anchor size M8 M10 M12 M16 M20
Embedment depth hnom,min = [mm] 60 60 60 96 100
Base material thickness hmin= [mm] 120 120 120 196 200
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non-cracked concrete
cmin [mm] 40 80 115 110 165
HIT-Z / HIT-Z-R [kN] 7,8 10,5 13,2 20,1 25,7
Cracked concrete
cmin [mm] 40 80 115 110 165
HIT-Z / HIT-Z-R [kN] 6,7 10,2 11,2 18,5 24,0
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non-cracked concrete
cmin [mm] 40 80 115 110 165
HIT-Z [kN] 3,5 9,2 12,8 16,3 26,0
HIT-Z-R [kN] 3,5 9,2 12,8 16,3 26,0
Cracked concrete
cmin [mm] 40 80 115 110 165
HIT-Z [kN] 2,5 6,5 9,1 11,6 18,4
HIT-Z-R [kN] 2,5 6,5 9,1 11,6 18,4

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20
Embedment depth hnom,min = [mm] 60 60 60 96 100
Base material thickness hmin= [mm] 120 120 120 196 200
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non-cracked concrete
smin [mm] 40 50 60 80 100
HIT-Z / HIT-Z-R [kN] 8,9 9,2 9,5 18,7 20,3
Cracked concrete
smin [mm] 40 50 60 80 100
HIT-Z / HIT-Z-R [kN] 6,8 7,1 7,4 14,4 16,0
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non-cracked concrete
smin [mm] 40 50 60 80 100
HIT-Z [kN] 9,6 15,2 20,9 38,4 44,9
HIT-Z-R [kN] 11,2 18,4 20,9 40,5 44,9
Cracked concrete
smin [mm] 40 50 60 80 100
HIT-Z [kN] 9,6 14,3 14,9 28,8 32,0
HIT-Z-R [kN] 11,2 14,3 14,9 28,8 32,0

10 / 2012 505
Hilti HIT-HY 200
with HIT-Z

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Anchor size M8 M10 M12 M16 M20
Embedment depth hnom,typ = [mm] 70 90 110 145 180
Base material thickness hmin= [mm] 130 150 170 245 280
Tensile NRd: single anchor, no edge effects
Non-cracked concrete
HIT-Z / HIT-Z-R [kN] 16,0 25,3 36,2 58,8 81,3
Cracked concrete
HIT-Z / HIT-Z-R [kN] 14,1 20,5 27,7 41,9 58,0
Shear VRd: single anchor, no edge effects, without lever arm
Non-cracked concrete
HIT-Z [kN] 9,6 15,2 21,6 38,4 58,4
HIT-Z-R [kN] 11,2 18,4 26,4 45,6 70,4
Cracked concrete
HIT-Z [kN] 9,6 15,2 21,6 38,4 58,4
HIT-Z-R [kN] 11,2 18,4 26,4 45,6 70,4

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Anchor size M8 M10 M12 M16 M20
Embedment depth hnom,typ = [mm] 70 90 110 145 180
Base material thickness hmin= [mm] 130 150 170 245 280
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non-cracked concrete
cmin [mm] 40 65 80 90 120
HIT-Z / HIT-Z-R [kN] 9,1 13,7 18,1 27,0 37,2
Cracked concrete
cmin [mm] 40 65 80 90 120
HIT-Z / HIT-Z-R [kN] 7,9 12,8 17,4 24,4 34,9
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non-cracked concrete
cmin [mm] 40 65 80 90 120
HIT-Z [kN] 3,6 7,5 10,6 13,8 21,8
HIT-Z-R [kN] 3,6 7,5 10,6 13,8 21,8
Cracked concrete
cmin [mm] 40 65 80 90 120
HIT-Z [kN] 2,6 5,3 7,5 9,8 15,5
HIT-Z-R [kN] 2,6 5,3 7,5 9,8 15,5

506 10 / 2012
Hilti HIT-HY 200
with HIT-Z

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20
Embedment depth hnom,typ = [mm] 70 90 110 145 180
Base material thickness hmin= [mm] 130 150 170 245 280
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non-cracked concrete
smin [mm] 40 50 60 80 100
HIT-Z / HIT-Z-R [kN] 10,9 15,7 21,0 32,1 44,1
Cracked concrete
smin [mm] 40 50 60 80 100
HIT-Z / HIT-Z-R [kN] 8,4 12,1 16,4 24,8 34,3
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non-cracked concrete
smin [mm] 40 50 60 80 100
HIT-Z [kN] 9,6 15,2 21,6 38,4 58,4
HIT-Z-R [kN] 11,2 18,4 26,4 45,6 70,4
Cracked concrete
smin [mm] 40 50 60 80 100
HIT-Z [kN] 9,6 15,2 21,6 38,4 58,4
HIT-Z-R [kN] 11,2 18,4 26,4 45,6 68,7

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Anchor size M8 M10 M12 M16 M20
Embedment depth hnom,max = [mm] 100 120 150 200 220
Base material thickness hmin= [mm] 160 180 210 300 320
Tensile NRd: single anchor, no edge effects
Non-cracked concrete
HIT-Z / HIT-Z-R [kN] 16,0 25,3 36,2 64,0 97,3
Cracked concrete
HIT-Z / HIT-Z-R [kN] 16,0 25,3 33,2 64,0 78,3
Shear VRd: single anchor, no edge effects, without lever arm
Non-cracked concrete
HIT-Z [kN] 9,6 15,2 21,6 38,4 58,4
HIT-Z-R [kN] 11,2 18,4 26,4 45,6 70,4
Cracked concrete
HIT-Z [kN] 9,6 15,2 21,6 38,4 58,4
HIT-Z-R [kN] 11,2 18,4 26,4 45,6 70,4

10 / 2012 507
Hilti HIT-HY 200
with HIT-Z

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Anchor size M8 M10 M12 M16 M20
Embedment depth hnom,max = [mm] 100 120 150 200 220
Base material thickness hmin= [mm] 160 180 210 300 320
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non-cracked concrete
cmin [mm] 40 55 65 80 105
HIT-Z / HIT-Z-R [kN] 10,1 15,6 18,6 38,7 46,3
Cracked concrete
cmin [mm] 40 55 65 80 105
HIT-Z / HIT-Z-R [kN] 9,2 14,3 17,1 33,5 41,1
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non-cracked concrete
cmin [mm] 40 55 65 80 105
HIT-Z [kN] 3,9 6,4 8,7 13,0 19,6
HIT-Z-R [kN] 3,9 6,4 8,7 13,0 19,6
Cracked concrete
cmin [mm] 40 55 65 80 105
HIT-Z [kN] 2,8 4,6 6,2 9,2 13,9
HIT-Z-R [kN] 2,8 4,6 6,2 9,2 13,9

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20
Embedment depth hnom,max = [mm] 100 120 150 200 220
Base material thickness hmin= [mm] 160 180 210 300 320
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non-cracked concrete
smin [mm] 40 50 60 80 100
HIT-Z / HIT-Z-R [kN] 11,5 17,2 20,6 44,0 57,9
Cracked concrete
smin [mm] 40 50 60 80 100
HIT-Z / HIT-Z-R [kN] 10,5 15,8 18,9 38,5 45,1
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non-cracked concrete
smin [mm] 40 50 60 80 100
HIT-Z [kN] 9,6 15,2 21,6 38,4 58,4
HIT-Z-R [kN] 11,2 18,4 26,4 45,6 70,4
Cracked concrete
smin [mm] 40 50 60 80 100
HIT-Z [kN] 9,6 15,2 21,6 38,4 58,4
HIT-Z-R [kN] 11,2 18,4 26,4 45,6 70,4

508 10 / 2012
Hilti HIT-HY 200
with HIT-Z

10 / 2012 509
Hilti HIT-HY 200
with HIT-V

Hilti HIT-HY 200 with HIT-V


Injection mortar system Benefits

- Suitable for non-cracked and


Hilti HIT-
cracked concrete
HY 200-A
C 20/25 to C 50/60
500 ml foil pack
(also available - Approved automatic cleaning with
as 330 ml the use of the hollow drill-bit
foil pack) - High loading capacity, excellent
handling and fast curing
- Small edge distance and anchor
Hilti HIT- spacing possible
HY 200-R - Large diameter applications
500 ml foil pack
(also available - Max In service temperature range
as 330 ml up to 120C short term/
foil pack) 72C long term
- Manual cleaning for borehole
diameter up to 20mm and hef
10d for non-cracked concrete
Static mixer only
- Embedment depth range:
from 60 ... 160 mm for M8
HIT-V rods to 120 ... 600 mm for M30
HIT-V-R rods - Two mortar (A and R) versions
HIT-V-HCR rods available with different curing
times and same performance

Small edge Variable High European


Tensile Fire Corrosion CE
Concrete distance embedment corrosion Technical
zone resistance resistance conformity
and spacing depth resistance Approval

Approved PROFIS
automatic Anchor
cleaning design
while drilling software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
ETA-11/0493 / 2012-08-08
a) (Hilti HIT-HY 200-A)
European technical approval DIBt, Berlin
ETA-12/0084 / 2012-08-08
(Hilti HIT-HY 200-R)
Fire test report IBMB, Brunswick 3501/676/13 / 2012-08-03
a) All data given in this section according ETA-11/0493 and ETA-12/0084, issue 2012-08-08.

510 10 / 2012
Hilti HIT-HY 200
with HIT-V

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range -10C to +40C

Embedment depth a) and base material thickness for the basic loading data. Mean
ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth hef [mm] 80 90 110 125 170 210 240 270
Base material thickness h [mm] 110 120 140 165 220 270 300 340
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.

Mean ultimate resistance: concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non-cracked concrete
Tensile NRu,m HIT-V 5.8 [kN] 18,9 30,5 44,1 83,0 129,2 185,9 241,5 295,1
Shear VRu,m HIT-V 5.8 [kN] 9,5 15,8 22,1 41,0 64,1 92,4 120,8 147,0
Cracked concrete
Tensile NRu,m HIT-V 5.8 [kN] 16,0 22,5 44,0 66,7 105,9 145,4 177,7 212,0
Shear VRu,m HIT-V 5.8 [kN] 9,5 15,8 22,1 41,0 64,1 92,4 120,8 147,0

Characteristic resistance: concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non-cracked concrete
Tensile NRk HIT-V 5.8 [kN] 18,0 29,0 42,0 70,6 111,9 153,7 187,8 224,0
Shear VRk HIT-V 5.8 [kN] 9,0 15,0 21,0 39,0 61,0 88,0 115,0 140,0
Cracked concrete
Tensile NRk HIT-V 5.8 [kN] 12,1 17,0 33,2 50,3 79,8 109,6 133,9 159,7
Shear VRk HIT-V 5.8 [kN] 9,0 15,0 21,0 39,0 61,0 88,0 115,0 140,0

Design resistance: concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non-cracked concrete
Tensile NRd HIT-V 5.8 [kN] 12,0 19,3 28,0 39,2 62,2 85,4 104,3 124,5
Shear VRd HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
Cracked concrete
Tensile NRd HIT-V 5.8 [kN] 6,7 9,4 18,4 27,9 44,3 60,9 74,4 88,7
Shear VRd HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0

10 / 2012 511
Hilti HIT-HY 200
with HIT-V

Recommended loads a): concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non-cracked concrete
Tensile Nrec HIT-V 5.8 [kN] 8,6 13,8 20,0 28,0 44,4 61,0 74,5 88,9
Shear Vrec HIT-V 5.8 [kN] 5,1 8,6 12,0 22,3 34,9 50,3 65,7 80,0
Cracked concrete
Tensile Nrec HIT-V 5.8 [kN] 4,8 6,7 13,2 19,9 31,7 43,5 53,1 63,4
Shear Vrec HIT-V 5.8 [kN] 5,1 8,6 12,0 22,3 34,9 50,3 65,7 80,0
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-HY 200 injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +80 C +50 C +80 C
Temperature range III -40 C to +120 C +72 C +120 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of HIT-V
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HIT-V 5.8 [N/mm] 500 500 500 500 500 500 500 500
Nominal HIT-V 8.8 [N/mm] 800 800 800 800 800 800 800 800
tensile
strength fuk HIT-V-R [N/mm] 700 700 700 700 700 700 500 500
HIT-V-HCR [N/mm] 800 800 800 800 800 700 700 700
HIT-V 5.8 [N/mm] 400 400 400 400 400 400 400 400
Yield HIT-V 8.8 [N/mm] 640 640 640 640 640 640 640 640
strength fyk HIT-V -R [N/mm] 450 450 450 450 450 450 210 210
HIT-V-HCR [N/mm] 640 640 640 640 640 400 400 400
Stressed
cross- HIT-V [mm] 36,6 58,0 84,3 157 245 353 459 561
section As
Moment of
resistance HIT-V [mm] 31,2 62,3 109 277 541 935 1387 1874
W

512 10 / 2012
Hilti HIT-HY 200
with HIT-V

Material quality
Part Material
Threaded rod Strength class 5.8, A5 > 8% ductile
HIT-V(F) steel galvanized 5 m,
(F) hot dipped galvanized 45 m,
Threaded rod Strength class 8.8, A5 > 8% ductile
HIT-V(F) steel galvanized 5 m,
(F) hot dipped galvanized 45 m,
Stainless steel grade A4, A5 > 8% ductile
Threaded rod
strength class 70 for M24 and class 50 for M27 to M30, 1.4401; 1.4404;
HIT-V-R
1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, 1.4529; 1.4565
Threaded rod
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
HIT-V-HCR
M24 to M30: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, hot dipped galvanized,
Washer
Stainless steel, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
ISO 7089
High corrosion resistant steel, 1.4529; 1.4565
Strength class 8,
steel galvanized 5 m,
hot dipped galvanized 45 m,
Nut
Strength class 70, stainless steel grade A4,
EN ISO 4032
1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, high corrosion resistant steel,
1.4529; 1.4565

Anchor dimensions
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Anchor rod
Anchor rods HIT-V (-R / -HCR) are available in variable length
HIT-V, HIT-V-R, HIT-V-HCR

Setting
installation equipment
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools, hammer drilling compressed air gun or blow out pump, set of cleaning brushes, dispenser

Setting instruction
Bore hole drilling
Drill hole to the required embedment depth with an appropriately sized Hilti
TE-CD or TE-YD hollow drill bit with Hilti vacuum attachment. This drilling
method properly cleans the borehole and removes dust while drilling.
After drilling is complete, proceed to the injection preparation step in the
instructions for use.

Drill Hole to the required embedment depth with a hammer drill set in
rotation-hammer mode using an appropriately sized carbide drill bit.

10 / 2012 513
Hilti HIT-HY 200
with HIT-V

Bore hole cleaning Just before setting an anchor, the bore hole must be free of dust and debris.
a) Manual Cleaning (MC) non-cracked concrete only
for bore hole diameters d0 20mm and bore hole depth h0 10d
The Hilti manual pump may be used for blowing out bore holes up to
diameters d0 20 mm and embedment depths up to hef 10d.
Blow out at least 4 times from the back of the bore hole until return air
stream is free of noticeable dust

Brush 4 times with the specified brush size by inserting the steel brush Hilti
HIT-RB to the back of the hole (if needed with extension) in a twisting
motion and removing it.
The brush must produce natural resistance as it enters the bore hole -- if
not the brush is too small and must be replaced with the proper brush
diameter.
Blow out again with manual pump at least 4 times until return air stream is
free of noticeable dust.

b) Compressed air cleaning (CAC)


for all bore hole diameters d0 and all bore hole depth h0
Blow 2 times from the back of the hole (if needed with nozzle extension)
over the hole length with oil-free compressed air (min. 6 bar at 6 m/h) until
return air stream is free of noticeable dust. Bore hole diameter 32 mm
the compressor must supply a minimum air flow of 140 m/hour.

Brush 2 times with the specified brush size by inserting the steel brush Hilti
HIT-RB to the back of the hole (if needed with extension) in a twisting
motion and removing it.
The brush must produce natural resistance as it enters the bore hole -- if
not the brush is too small and must be replaced with the proper brush
diameter.
Blow again with compressed air 2 times until return air stream is free of
noticeable dust.

514 10 / 2012
Hilti HIT-HY 200
with HIT-V

Injection preparation
Tightly attach new Hilti mixing nozzle HIT-RE-M to foil pack manifold (snug
fit). Do not modify the mixing nozzle. Observe the instruction for use of the
dispenser. Check foil pack holder for proper function. Do not use damaged
foil packs / holders. Swing foil pack holder with foil pack into HIT-
dispenser.

Discard initial adhesive. The foil pack opens automatically as dispensing is


initiated. Depending on the size of the foil pack an initial amount of
adhesive has to be discarded.
Discard quantities are:
2 strokes for 330 ml foil pack,
3 strokes for 500 ml foil pack,
4 strokes for 500 ml foil pack 5C.
Inject adhesive from the back of the borehole without forming air voids
Inject the adhesive starting at the back of the hole, slowly withdrawing the
mixer with each trigger pull. Fill holes approximately 2/3 full, or as required
to ensure that the annular gap between the anchor and the concrete is
completely filled with adhesive along the embedment length.

After injection is completed, depressurize the dispenser by pressing the


release trigger. This will prevent further adhesive discharge from the mixer.

Overhead installation and/or installation with embedment depth hef >


250mm. For overhead installation the injection is only possible with the aid
of extensions and piston plugs. Assemble HIT-RE-M mixer, extension(s)
and appropriately sized piston plug. Insert piston plug to back of the hole
and inject adhesive. During injection the piston plug will be naturally
extruded out of the bore hole by the adhesive pressure.

Setting the element


Before use, verify that the element is dry and free of oil and other
contaminants.
Mark and set element to the required embedment depth untill working time
twork has elapsed.

For overhead installation use piston plugs and fix embedded parts with e.g.
wedges

Loading the anchor:


After required curing time tcure the anchor can be loaded.
The applied installation torque shall not exceed Tmax.

For detailed information on installation see instruction for use given with the package of the product.

10 / 2012 515
Hilti HIT-HY 200
with HIT-V

Working time, curing time


Temperature Hilti HIT-HY 200-R
of the Working time in which anchor Curing time before anchor
base material can be inserted and adjusted twork can be loaded tcure
-10 C to -5 C 3 hour 20 hour
-4 C to 0 C 2 hour 7 hour
1 C to 5 C 1 hour 3 hour
6 C to 10 C 40 min 2 hour
11 C to 20 C 15 min 1 hour
21 C to 30 C 9 min 1 hour
31 C to 40 C 6 min 1 hour

Temperature Hilti HIT-HY 200-A


of the Working time in which anchor Curing time before anchor
base material can be inserted and adjusted twork can be loaded tcure
-10 C to -5 C 1,5 hour 7 hour
-4 C to 0 C 50 min 4 hour
1 C to 5 C 25 min 2 hour
6 C to 10 C 15 min 1 hour
11 C to 20 C 7 min 30 min
21 C to 30 C 4 min 30 min
31 C to 40 C 3 min 30 min

Setting details
Marking of the
embedment depth
performed in field
d0

df

Fixture
Bore hole depth h0 = anchorage depth hef Thickness tfix

Thickness of concrete member h

516 10 / 2012
Hilti HIT-HY 200
with HIT-V

Setting details
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Nominal diameter of
d0 [mm] 10 12 14 18 22 28 30 35
drill bit
Effective embedment and hef,min [mm] 60 60 70 80 90 96 108 120
drill hole depth range
a)

for HIT-V hef,max [mm] 160 200 240 320 400 480 540 600
Minimum base
hmin [mm] hef + 30 mm hef + 2 d0
material thickness
Diameter of clearance
df [mm] 9 12 14 18 22 26 30 33
hole in the fixture
b)
Torque moment Tmax [Nm] 10 20 40 80 150 200 270 300
Minimum spacing smin [mm] 40 50 60 80 100 120 135 150
Minimum edge
cmin [mm] 40 50 60 80 100 120 135 150
distance
Critical spacing
scr,sp [mm] 2 ccr,sp
for splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


c) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N [mm] 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N [mm] 1,5 hef
d)
failure

For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a) Embedment depth range: hef,min hef hef,max
b) Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing
and/or edge distance.
c) h: base material thickness (h hmin), hef: embedment depth
d) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the safe side.

10 / 2012 517
Hilti HIT-HY 200
with HIT-V

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in
ETA-11/0493 issued 2012-08-08 for HIT-HY 200-A and ETA-12/0084 issued 2012-08-08 for HIT-HY 200-R. Both
mortars possess identical technical load performance.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The simplified calculated design loads take a conservative approach: They will be
lower than the exact values according to ETAG 001, TR 029. For an optimized design, anchor calculation
can be performed using PROFIS anchor design software.
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

TENSION loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HIT-V 5.8 [kN] 12,0 19,3 28,0 52,7 82,0 118,0 153,3 187,3
HIT-V 8.8 [kN] 19,3 30,7 44,7 84,0 130,7 188,0 244,7 299,3
NRd,s
HIT-V-R [kN] 13,9 21,9 31,6 58,8 92,0 132,1 80,4 98,3
HIT-V-HCR [kN] 19,3 30,7 44,7 84,0 130,7 117,6 152,9 187,1

518 10 / 2012
Hilti HIT-HY 200
with HIT-V

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth
80 90 110 125 170 210 240 270
hef = hef,typ [mm]
Non-cracked concrete
0
N Rd,p Temperature range I [kN] 22,3 31,4 46,1 69,8 118,7 175,9 169,6 212,1
0
N Rd,p Temperature range II [kN] 19,0 26,7 39,2 59,3 100,9 149,5 135,7 169,6
0
N Rd,p Temperature range III [kN] 15,6 22,0 32,3 48,9 83,1 123,2 124,4 155,5
Cracked concrete
0
N Rd,p Temperature range I [kN] 6,7 9,4 18,4 27,9 47,5 70,4 90,5 113,1
0
N Rd,p Temperature range II [kN] 5,0 7,1 15,0 22,7 38,6 57,2 73,5 91,9
0
N Rd,p Temperature range III [kN] 4,5 6,3 12,7 19,2 32,6 48,4 62,2 77,8

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
0
N Rd,c Non-cracked concrete [kN] 20,1 24,0 32,4 39,2 62,2 85,4 104,3 124,5
0
N Rd,c Cracked concrete [kN] 14,3 17,1 23,1 28,0 44,3 60,9 74,4 88,7
a) Splitting resistance must only be considered for non-cracked concrete.

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
fB,p = 1,00 1,00 1,00 1,00 1,00 1,00 1,00

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,5 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N 1
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp 1

f2,N = 0,5(1 + c/ccr,N) 1


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp) 1
a) The edge distance shall not be smaller than the minimum edge distance cmin. These influencing factors must
be considered for every edge distance smaller than the critical edge distance.

10 / 2012 519
Hilti HIT-HY 200
with HIT-V

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N) 1
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp) 1
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin. This influencing factor must be
considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hef/hef,typ)

Influence of reinforcement
hef [mm] 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a)
0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.

SHEAR loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
VRd,s
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 110,3

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k=2
a) NRd,p: Design combined pull-out and concrete cone resistance, NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 18,7 27,0 36,6 44,5 53,0
Cracked concrete
0
V Rd,c [kN] 4,2 6,1 8,2 13,2 19,2 25,9 31,5 37,5

520 10 / 2012
Hilti HIT-HY 200
with HIT-V

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

10 / 2012 521
Hilti HIT-HY 200
with HIT-V

Influence of embedment depth


hef/d 4 4,5 5 6 7 8 9 10 11
0,05 (hef / d)
1,68
f hef = 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81
hef/d 12 13 14 15 16 17 18 19 20
0,05 (hef / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined TENSION and SHEAR loading


For combined tension and shear loading see section Anchor Design.

Precalculated values design resistance values


All data applies to:
- non-cracked concrete C 20/25 fck,cube =25 N/mm
- temperature range I (see service temperature range)
- minimum thickness of base material
- no effects of dense reinforcement

Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

522 10 / 2012
Hilti HIT-HY 200
with HIT-V

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - minimum embedment depth


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,min [mm] 60 60 70 80 90 96 108 120
Base material thickness h = hmin [mm] 90 90 100 116 138 152 168 190
Tensile NRd: single anchor, no edge effects
Non-cracked concrete
HIT-V 5.8 [kN] 12,0 13,0 16,4 20,1 24,0 26,4 31,5 36,9
HIT-V 8.8 [kN] 13,0 13,0 16,4 20,1 24,0 26,4 31,5 36,9
HIT-V-R [kN] 13,0 13,0 16,4 20,1 24,0 26,4 31,5 36,9
HIT-V-HCR [kN] 13,0 13,0 16,4 20,1 24,0 26,4 31,5 36,9
Cracked concrete
HIT-V 5.8 / 8.8
[kN] 5,0 6,3 11,7 14,3 17,1 18,8 22,4 26,3
HIT-V-R / -HCR
Shear VRd: single anchor, no edge effects, without lever arm
Non-cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 63,3 75,6 88,5
HIT-V 8.8 [kN] 12,0 18,4 27,2 48,2 57,5 63,3 75,6 88,5
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 63,3 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 48,2 57,5 63,3 75,6 88,5
Cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 41,0 45,1 53,9 63,1
HIT-V 8.8 [kN] 12,0 15,1 27,2 34,3 41,0 45,1 53,9 63,1
HIT-V-R [kN] 8,3 12,8 19,2 34,3 41,0 45,1 48,3 58,8
HIT-V-HCR [kN] 12,0 15,1 27,2 34,3 41,0 45,1 53,9 63,1

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - minimum embedment depth


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,min [mm] 60 60 70 80 90 96 108 120
Base material thickness h = hmin [mm] 90 90 100 116 134 152 168 190
Edge distance c = cmin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 7,1 7,8 9,7 12,8 16,5 20,7 24,2 28,9
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] 3,0 4,2 8,0 10,7 13,7 16,4 19,5 22,9
HIT-V-R / -HCR
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 3,5 4,9 6,6 10,2 13,9 17,9 21,5 25,9
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] 2,5 3,5 4,7 7,2 9,9 12,7 15,3 18,3
HIT-V-R / -HCR

10 / 2012 523
Hilti HIT-HY 200
with HIT-V

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - minimum embedment depth


(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,min [mm] 60 60 70 80 90 96 108 120
Base material thickness h = hmin [mm] 90 90 100 116 134 152 168 190
Spacing s = smin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 7,7 7,9 10,0 12,6 15,4 17,9 21,2 25,0
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] 3,5 4,4 7,5 9,5 11,7 13,3 15,9 18,6
HIT-V-R / -HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
Non-cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 39,4 44,9 53,5 62,7
HIT-V 8.8 [kN] 12,0 18,4 25,4 32,1 39,4 44,9 53,5 62,7
HIT-V-R [kN] 8,3 12,8 19,2 32,1 39,4 44,9 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 25,4 32,1 39,4 44,9 53,5 62,7
Cracked concrete
HIT-V 5.8 / 8.8
[kN] 7,2 9,6 16,8 22,9 28,1 32,0 38,2 44,7
HIT-V-R / -HCR

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - typical embedment depth


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,typ [mm] 80 90 110 125 170 210 240 270
Base material thickness h = hmin [mm] 110 120 140 161 214 266 300 340
Tensile NRd: single anchor, no edge effects
Non-cracked concrete
HIT-V 5.8 [kN] 12,0 19,3 28,0 39,2 62,2 85,4 104,3 124,5
HIT-V 8.8 [kN] 19,3 24,0 32,4 39,2 62,2 85,4 104,3 124,5
HIT-V-R [kN] 13,9 21,9 31,6 39,2 62,2 85,4 80,4 98,3
HIT-V-HCR [kN] 19,3 24,0 32,4 39,2 62,2 85,4 104,3 124,5
Cracked concrete
HIT-V 5.8 / 8.8
[kN] 6,7 9,4 18,4 27,9 44,3 60,9 74,4 88,7
HIT-V-R / -HCR
Shear VRd: single anchor, no edge effects, without lever arm
Non-cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 110,3
Cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 110,3

524 10 / 2012
Hilti HIT-HY 200
with HIT-V

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - typical embedment depth


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,typ [mm] 80 90 110 125 170 210 240 270
Base material thickness h = hmin [mm] 110 120 140 161 214 266 300 340
Edge distance c = cmin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 9,6 11,6 15,5 19,9 30,5 41,5 50,5 60,0
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] 3,6 5,2 10,2 16,5 25,2 34,2 41,5 49,3
HIT-V-R / -HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 3,7 5,3 7,3 11,5 17,2 23,6 29,0 34,8
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] 2,6 3,8 5,2 8,1 12,2 16,7 20,5 24,7
HIT-V-R / -HCR

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - typical embedment depth


(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,typ [mm] 80 90 110 125 170 210 240 270
Base material thickness h = hmin [mm] 110 120 140 161 214 266 300 340
Spacing s [mm] 40 50 60 80 100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 11,2 13,5 18,1 22,4 35,1 48,1 58,6 69,9
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] 4,6 6,4 11,6 17,0 26,5 36,2 44,2 52,6
HIT-V-R / -HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
Non-cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 177,0
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 110,3
Cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 9,4 13,4 26,1 40,7 63,6 86,9 106,0 126,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 9,4 13,4 26,1 40,7 63,6 70,9 92,0 110,3

10 / 2012 525
Hilti HIT-HY 200
with HIT-V

a)
Design resistance: concrete C 20/25 fck,cube = 25 N/mm - embedment depth = 12 d
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288 324 360
Base material thickness h = hmin [mm] 126 150 174 228 284 344 384 430
Tensile NRd: single anchor, no edge effects
Non-cracked concrete
HIT-V 5.8 [kN] 12,0 19,3 28,0 52,7 82,0 118,0 153,3 187,3
HIT-V 8.8 [kN] 19,3 30,7 44,7 74,6 104,3 137,1 163,6 191,6
HIT-V-R [kN] 13,9 21,9 31,6 58,8 92,0 132,1 80,4 98,3
HIT-V-HCR [kN] 19,3 30,7 44,7 74,6 104,3 117,6 152,9 187,1
Cracked concrete
HIT-V 5.8 / 8.8
[kN] 8,0 12,6 24,1 42,9 67,0 96,5 116,6 136,6
HIT-V-R / -HCR
Shear VRd: single anchor, no edge effects, without lever arm
Non-cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 110,3
Cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 110,3
a) d = element diameter
a)
Design resistance: concrete C 20/25 fck,cube = 25 N/mm - embedment depth = 12 d
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288 324 360
Base material thickness h = hmin [mm] 126 150 174 228 284 344 384 430
Edge distance c = cmin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non-cracked concrete
HIT-V 5.8 [kN] 11,8 16,5 21,7 33,4 46,7 61.3 73.2 85,7
HIT-V 8.8 [kN] 11,8 16,5 21,7 33,4 46,7 61.3 73.2 85,7
HIT-V-R [kN] 11,8 16,5 21,7 33,4 46,7 61.3 73.2 85,7
HIT-V-HCR [kN] 11,8 16,5 21,7 33,4 46,7 61.3 73.2 85,7
Cracked concrete
HIT-V 5.8 / 8.8
[kN] 4,2 6,5 12,5 22,2 34,7 48,9 58,4 68,4
HIT-V-R / -HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 3,9 5,7 7,8 12,9 18,9 25,9 31,8 38,1
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] 2,8 4,0 5,5 9,1 13,4 18,4 22,5 27,0
HIT-V-R / -HCR
a) d = element diameter

526 10 / 2012
Hilti HIT-HY 200
with HIT-V

a)
Design resistance: concrete C 20/25 fck,cube = 25 N/mm - embedment depth = 12 d
(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288 324 360
Base material thickness h = hmin [mm] 126 150 174 228 284 344 384 430
Spacing s=smin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non-cracked concrete
HIT-V 5.8 [kN] 12,0 19,3 26,5 40,8 57,0 74,9 89,4 104,6
HIT-V 8.8 [kN] 14,4 20,1 26,5 40,8 57,0 74,9 89,4 104,6
HIT-V-R [kN] 13,9 20,1 26,5 40,8 57,0 74,9 80,4 98,3
HIT-V-HCR [kN] 14,4 20,1 26,5 40,8 57,0 74,9 89,4 104,6
Cracked concrete
HIT-V 5.8 / 8.8
[kN] 5,5 8,5 15,4 26,5 40,1 55,7 66,4 77,8
HIT-V-R / -HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non-cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 110,3
Cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 11,0 17,2 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 11,0 17,2 27,2 50,4 78,4 70,9 92,0 110,3
a) d = element diameter

10 / 2012 527
Hilti HIT-HY 200
with HIS-(R)N

Hilti HIT-HY 200 with HIS-(R)N


Injection mortar system Benefits

Hilti HIT- - Suitable for cracked and non-


HY 200-A cracked concrete
500 ml foil pack C 20/25 to C 50/60.
(also available - Approved automatic cleaning with
as 330 ml) the use of the hollow drill-bit
- High loading capacity, excellent
Hilti HIT- handling, and fast curing
HY 200-R - Small edge distance and anchor
500 ml foil pack spacing possible
(also available
- Corrosion resistant
as 330 ml)
- In service temperature range up
to 120C short term/72C long
Static mixer term
- Manual cleaning for anchor size
M8 and M10
Internal
threaded sleeve - Two mortar (A and R) versions
HIS-N available with different curing
HIS-RN times and same performance

Approved PROFIS
Small edge European
Tensile Corrosion CE automatic Anchor
Concrete distance Technical
zone resistance conformity cleaning design
and spacing Approval
while drilling software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
ETA-11/0493 / 2012-08-08
a) (Hilti HIT-HY 200-A)
European technical approval DIBt, Berlin
ETA-12/0084 / 2012-08-08
(Hilti HIT-HY 200-R)

a) All data given in this section according ETA-11/0493 and ETA-12/0084, issue 2012-08-08.

528 10 / 2012
Hilti HIT-HY 200
with HIS-(R)N

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range -10C to +40C

Embedment depth and base material thickness for the basic loading data. Mean
ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
Base material thickness h [mm] 120 150 170 230 270

Mean ultimate resistance: concrete C 20/25 , anchor HIS-N with screw 8.8
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Non cracked concrete
Tensile NRu,m HIS-N [kN] 26,3 48,3 70,4 123,9 114,5
Shear VRu,m HIS-N [kN] 13,7 24,2 41,0 62,0 57,8
Cracked concrete
Tensile NRu,m HIS-N [kN] 26,3 48,3 66,8 105,9 114,5
Shear VRu,m HIS-N [kN] 13,7 24,2 41,0 62,0 57,8

Characteristic resistance: concrete C 20/25 , anchor HIS-N with screw 8.8


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Non cracked concrete
Tensile NRk HIS-N [kN] 25,0 46,0 67,0 111,9 109,0
Shear VRk HIS-N [kN] 13,0 23,0 39,0 59,0 55,0
Cracked concrete
Tensile NRk HIS-N [kN] 24,7 39,9 50,3 79,8 105,7
Shear VRk HIS-N [kN] 13,0 23,0 39,0 59,0 55,0

Design resistance: concrete C 20/25 , anchor HIS-N with screw 8.8


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Cracked concrete
Tensile NRd HIS-N [kN] 17,5 30,7 44,7 74,6 74,1
Shear VRd HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
Non cracked concrete
Tensile NRd HIS-N [kN] 16,5 26,6 33,5 53,2 70,4
Shear VRd HIS-N [kN] 10,4 18,4 26,0 39,3 36,7

10 / 2012 529
Hilti HIT-HY 200
with HIS-(R)N

Recommended loads a): concrete C 20/25 , anchor HIS-N with screw 8.8
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Non cracked concrete
Tensile Nrec HIS-N [kN] 12,5 27,9 31,9 53,3 53,0
Shear Vrec HIS-N [kN] 7,4 13,1 18,6 28,1 26,2
Cracked concrete
Tensile Nrec HIS-N [kN] 11,8 19,0 24,0 38,0 50,3
Shear Vrec HIS-N [kN] 7,4 13,1 18,6 28,1 26,2

a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-HY 200 injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +80 C +50 C +80 C
Temperature range III -40 C to +120 C +72 C +120 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of HIS-(R)N
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
HIS-N [N/mm] 490 460 460 460 460
Nominal Screw 8.8 [N/mm] 800 800 800 800 800
tensile
strength fuk HIS-RN [N/mm] 700 700 700 700 700
Screw A4-70 [N/mm] 700 700 700 700 700
HIS-N [N/mm] 410 375 375 375 375
Yield Screw 8.8 [N/mm] 640 640 640 640 640
strength fyk HIS-RN [N/mm] 350 350 350 350 350
Screw A4-70 [N/mm] 450 450 450 450 450
Stressed HIS-(R)N [mm] 51,5 108,0 169,1 256,1 237,6
cross-
section As Screw [mm] 36,6 58 84,3 157 245
Moment of HIS-(R)N [mm] 145 430 840 1595 1543
resistance W Screw [mm] 31,2 62,3 109 277 541

530 10 / 2012
Hilti HIT-HY 200
with HIS-(R)N

Material quality
Part Material
a)
Internal threaded sleeve C-steel 1.0718,
HIS-N Steel galvanized 5m
b)
Internal threaded sleeve
Stainless steel 1.4401 and 1.4571
HIS-RN
a) related fastening screw: strength class 8.8, A5 > 8% Ductile
steel galvanized 5m
b) related fastening screw: strength class 70, A5 > 8% Ductile
stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362

Anchor dimensions
Anchor size
Internal threaded sleeve M8x90 M10x110 M12x125 M16x170 M20x205
HIS-N / HIS-RN
Embedment depth hef [mm] 90 110 125 170 205

Setting
installation equipment
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

Setting instruction

Bore hole drilling


Drill hole to the required embedment depth with an appropriately sized Hilti
TE-CD or TE-YD hollow drill bit with Hilti vacuum attachment. This drilling
method properly cleans the borehole and removes dust while drilling.
After drilling is complete, proceed to the injection preparation step in the
instructions for use.

Drill Hole to the required embedment depth with a hammer drill set in
rotation-hammer mode using an appropriately sized carbide drill bit.

10 / 2012 531
Hilti HIT-HY 200
with HIS-(R)N

Bore hole cleaning Just before setting an anchor, the bore hole must be free of dust and debris.

a) Manual Cleaning (MC) non-cracked concrete only


for bore hole diameters d0 20mm and bore hole depth h0 10d
The Hilti manual pump may be used for blowing out bore holes up to
diameters d0 20 mm and embedment depths up to hef 10d.
Blow out at least 4 times from the back of the bore hole until return air
stream is free of noticeable dust

Brush 4 times with the specified brush size by inserting the steel brush Hilti
HIT-RB to the back of the hole (if needed with extension) in a twisting
motion and removing it.
The brush must produce natural resistance as it enters the bore hole -- if
not the brush is too small and must be replaced with the proper brush
diameter.
Blow out again with manual pump at least 4 times until return air stream is
free of noticeable dust.

b) Compressed air cleaning (CAC)


for all bore hole diameters d0 and all bore hole depth h0
Blow 2 times from the back of the hole (if needed with nozzle extension)
over the hole length with oil-free compressed air (min. 6 bar at 6 m/h) until
return air stream is free of noticeable dust.

Brush 2 times with the specified brush size by inserting the steel brush Hilti
HIT-RB to the back of the hole (if needed with extension) in a twisting
motion and removing it.
The brush must produce natural resistance as it enters the bore hole -- if
not the brush is too small and must be replaced with the proper brush
diameter.
Blow again with compressed air 2 times until return air stream is free of
noticeable dust.

532 10 / 2012
Hilti HIT-HY 200
with HIS-(R)N

Injection preparation
Tightly attach new Hilti mixing nozzle HIT-RE-M to foil pack manifold (snug
fit). Do not modify the mixing nozzle. Observe the instruction for use of the
dispenser. Check foil pack holder for proper function. Do not use damaged
foil packs / holders. Swing foil pack holder with foil pack into HIT-
dispenser.

Discard initial adhesive. The foil pack opens automatically as dispensing is


initiated. Depending on the size of the foil pack an initial amount of
adhesive has to be discarded.
Discard quantities are
2 strokes for 330 ml foil pack,
3 strokes for 500 ml foil pack,
4 strokes for 500 ml foil pack 5C.
Inject adhesive from the back of the borehole without forming air voids
Inject the adhesive starting at the back of the hole, slowly withdrawing the
mixer with each trigger pull. Fill holes approximately 2/3 full, or as required
to ensure that the annular gap between the anchor and the concrete is
completely filled with adhesive along the embedment length.

After injection is completed, depressurize the dispenser by pressing the


release trigger. This will prevent further adhesive discharge from the mixer.

Overhead installation.
For overhead installation the injection is only possible with the aid of
extensions and piston plugs. Assemble HIT-RE-M mixer, extension(s) and
appropriately sized piston plug. Insert piston plug to back of the hole and
inject adhesive. During injection the piston plug will be naturally extruded
out of the bore hole by the adhesive pressure.

Setting the element


Before use, verify that the element is dry and free of oil and other
contaminants.
Mark and set element to the required embedment depth untill working time
twork has elapsed.

For overhead installation use piston plugs and fix embedded parts with
e.g. wedges

Loading the anchor:


After required curing time tcure the anchor can be loaded.
The applied installation torque shall not exceed Tmax.

For detailed information on installation see instruction for use given with the package of the product.

10 / 2012 533
Hilti HIT-HY 200
with HIS-(R)N

Working time, curing time


Temperature Hilti HIT-HY 200-R
of the Working time in which anchor Curing time before anchor
base material can be inserted and adjusted twork can be fully loaded tcure
-10 C to -5 C 3 hour 20 hour
-4 C to 0 C 2 hour 7 hour
1 C to 5 C 1 hour 3 hour
6 C to 10 C 40 min 2 hour
11 C to 20 C 15 min 1 hour
21 C to 30 C 9 min 1 hour
31 C to 40 C 6 min 1 hour

Temperature Hilti HIT-HY 200-A


of the Working time in which anchor Curing time before anchor
base material can be inserted and adjusted twork can be fully loaded tcure
-10 C to -5 C 1,5 hour 7 hour
-4 C to 0 C 50 min 4 hour
1 C to 5 C 25 min 2 hour
6 C to 10 C 15 min 1 hour
11 C to 20 C 7 min 30 min
21 C to 30 C 4 min 30 min
31 C to 40 C 3 min 30 min

Setting details
hS
df
d
d0

Bore hole depth h0 =


Embedment depth hef

534 10 / 2012
Hilti HIT-HY 200
with HIS-(R)N

Anchor size M8x90 M10x110 M12x125 M16x170 M20x205


Nominal diameter of
d0 [mm] 14 18 22 28 32
drill bit
Diameter of element d [mm] 12,5 16,5 20,5 25,4 27,6
Effective anchorage
hef [mm] 90 110 125 170 205
and drill hole depth
Minimum base
hmin [mm] 120 150 170 230 270
material thickness
Diameter of clearance
df [mm] 9 12 14 18 22
hole in the fixture
Thread engagement
hs [mm] 8-20 10-25 12-30 16-40 20-50
length; min - max
a)
Torque moment Tmax [Nm] 10 20 40 80 150
Minimum spacing smin [mm] 40 45 55 65 90
Minimum edge
cmin [mm] 40 45 55 65 90
distance
Critical spacing
scr,sp [mm] 2 ccr,sp
for splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


b) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N [mm] 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N [mm] 1,5 hef
c)
failure

For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a) Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing
and/or edge distance.
b) h: base material thickness (h hmin), hef: embedment depth
c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the safe side.

10 / 2012 535
Hilti HIT-HY 200
with HIS-(R)N

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in
ETA-11/0493 issued 2012-08-08 for HIT-HY 200-A and ETA-12/0084 issued 2012-08-08 for HIT-HY 200-R. Both
mortars possess identical technical load performance.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The simplified calculated design loads take a conservative approach: They will be
lower than the exact values according to ETAG 001, TR 029. For an optimized design, anchor calculation
can be performed using PROFIS anchor design software.
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

TENSION loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
HIS-N with screw 8.8 [kN] 17,5 30,7 44,7 80,3 74,1
NRd,s HIS-RN with screw
[kN] 13,9 21,9 31,6 58,8 69,2
A4-70

536 10 / 2012
Hilti HIT-HY 200
with HIS-(R)N

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
Non cracked concrete
0
N Rd,p Temperature range I [kN] 30,6 49,4 69,8 117,6 154,7
0
N Rd,p Temperature range II [kN] 25,9 41,8 59,0 99,5 130,4
0
N Rd,p Temperature range III [kN] 22,4 36,1 51,0 85,9 112,6
Cracked concrete
0
N Rd,p Temperature range I [kN] 16,5 26,6 37,6 63,3 83,0
0
N Rd,p Temperature range II [kN] 13,0 20,9 29,5 49,7 65,2
0
N Rd,p Temperature range III [kN] 11,8 19,0 26,8 45,2 59,3

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size M8 M10 M12 M16 M20
Non cracked concrete
0
N Rd,c [kN] 28,7 38,8 47,1 74,6 98,8
Cracked concrete
0
N Rd,c [kN] 20,5 27,7 33,5 53,2 70,4

a) Splitting resistance must only be considered for non-cracked concrete.

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,10 a)
fB,p = (fck,cube/25N/mm) fB,p = 1
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = 1

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,5 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N 1
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp 1

f2,N = 0,5(1 + c/ccr,N) 1


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp) 1
a) The edge distance shall not be smaller than the minimum edge distance cmin. These influencing factors must
be considered for every edge distance smaller than the critical edge distance.
10 / 2012 537
Hilti HIT-HY 200
with HIS-(R)N

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N) 1
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp) 1
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin. This influencing factor must
be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


fh,N = 1

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.

SHEAR loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s

- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c


fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
HIS-N with screw 8.8 [kN] 10,4 18,4 26,0 39,3 36,7
VRd,s HIS-RN with screw
[kN] 8,3 12,8 19,2 35,3 41,5
A4-70

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k=2
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

538 10 / 2012
Hilti HIT-HY 200
with HIS-(R)N

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
0
V Rd,c [kN] 12,4 19,6 28,2 40,2 46,2
Cracked concrete
0
V Rd,c [kN] 8,8 13,9 20,0 28,5 32,7

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

10 / 2012 539
Hilti HIT-HY 200
with HIS-(R)N

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


Anchor size M8 M10 M12 M16 M20
f hef = 1,38 1,21 1,04 1,22 1,45

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined TENSION and SHEAR loading


For combined tension and shear loading see section Anchor Design.

Precalculated values design resistance values


All data applies to:
- non-cracked concrete C 20/25 fck,cube =25 N/mm
- temperature range I (see service temperature range)
- minimum thickness of base material
- no effects of dense reinforcement

540 10 / 2012
Hilti HIT-HY 200
with HIS-(R)N

Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

Design resistance: non-cracked- concrete C 20/25


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
Base material thickness h = hmin [mm] 120 150 170 230 270
Tensile NRd: single anchor, no edge effects
Non-cracked concrete
HIS-N [kN] 17,5 30,7 44,7 74,6 74,1
HIS-RN [kN] 13,9 21,9 31,6 58,8 69,2
Cracked concrete
HIS-N [kN] 16,5 26,6 33,5 53,2 70,4
HIS-RN [kN] 13,9 21,9 31,6 53,2 69,2
Shear VRd: single anchor, no edge effects, without lever arm
Non-cracked concrete
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5
Cracked concrete
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

Design resistance: non-cracked- concrete C 20/25


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
Base material thickness h = hmin [mm] 120 150 170 230 270
Edge distance c = cmin [mm] 40 45 55 65 90
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non-cracked concrete
HIS-N [kN] 13,1 17,5 21,6 33,1 44,9
HIS-RN [kN] 13,1 17,5 21,6 33,1 44,9
Cracked concrete
HIS-N [kN] 8,4 13,2 17,1 25,9 35,9
HIS-RN [kN] 8,4 13,2 17,1 25,9 35,9
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
Non-cracked concrete
HIS-N [kN] 4,2 5,5 7,6 10,8 17,2
HIS-RN [kN] 4,2 5,5 7,6 10,8 17,2
Cracked concrete
HIS-N [kN] 3,0 3,9 5,4 7,7 12,2
HIS-RN [kN] 3,0 3,9 5,4 7,7 12,2

10 / 2012 541
Hilti HIT-HY 200
with HIS-(R)N

Design resistance: non-cracked- concrete C 20/25


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
Base material thickness h = hmin [mm] 120 150 170 230 270
Spacing s = smin [mm] 40 45 55 65 90
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non-cracked concrete
HIS-N [kN] 15,8 21,3 25,9 40,6 54,3
HIS-RN [kN] 13,9 21,3 25,9 40,6 54,3
Cracked concrete
HIS-N [kN] 10,1 15,4 19,2 30,0 40,4
HIS-RN [kN] 10,1 15,4 19,2 30,0 40,4
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
Non-cracked concrete
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5
Cracked concrete
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

542 10 / 2012
Hilti HIT-HY 200
with HIS-(R)N

10 / 2012 543
Hilti HIT-HY 200
with rebar

Hilti HIT-HY 200 with rebar


Injection mortar system Benefits

Hilti HIT- - suitable for cracked and non-


HY 200-A cracked concrete
500 ml foil pack C 20/25 to C 50/60.
(also available - Approved automatic cleaning with
as 330 ml) the use of the hollow drill-bit
- high loading capacity, excellent
Hilti HIT- handling
HY 200-R - HY 200-R version with extended
500 ml foil pack curing time for rebar applications
(also available - small edge distance and anchor
as 330 ml) spacing possible
- large diameter applications
- in service temperature range up
Static mixer to 120C short term/72C long
term
- manual cleaning for anchor size
8 to 16 and embedment depth
hef 10d for non-cracked
concrete
- embedment depth range:
rebar BSt 500 S from 60 ... 160 mm for 8
to 128 ... 640 mm for 32
- two mortar (A and R) versions
available with different curing
times and same performance

Approved PROFIS
Small edge Variable European
Tensile CE automatic Anchor
Concrete distance embedment Technical
zone conformity cleaning design
and spacing depth Approval
while drilling software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
ETA-11/0493 / 2012-08-08
a) (Hilti HIT-HY 200-A)
European technical approval DIBt, Berlin
ETA-12/0084 / 2012-08-08
(Hilti HIT-HY 200-R)

a) All data given in this section according ETA-11/0493 and ETA-12/0084, issue 2012-08-08.

544 10 / 2012
Hilti HIT-HY 200
with rebar

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range +5C to +40C

Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Typical embedment depth [mm] 80 90 110 125 145 170 210 270 300
Base material thickness [mm] 110 120 145 165 185 220 275 340 380
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.

Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500S
Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Non cracked concrete
Tensile NRu,m BSt 500 S [kN] 29,4 45,0 65,1 87,6 116,1 148,6 204,0 297,4 348,4
Shear VRu,m BSt 500 S [kN] 14,7 23,1 32,6 44,1 57,8 90,3 141,8 177,5 232,1
Cracked concrete
Tensile NRu,m BSt 500 S [kN] - 18,8 38,5 51,1 67,7 99,3 145,4 212,0 248,3
Shear VRu,m BSt 500 S [kN] - 23,1 32,6 44,1 57,8 90,3 141,8 177,5 232,1

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Non cracked concrete
Tensile NRk BSt 500 S [kN] 24,1 33,9 49,8 66,0 87,5 111,9 153,7 224,0 262,4
Shear VRk BSt 500 S [kN] 14,0 22,0 31,0 42,0 55,0 86,0 135,0 169,0 221,0
Cracked concrete
Tensile NRk BSt 500 S [kN] - 14,1 29,0 38,5 51,0 74,8 109,6 159,7 187,1
Shear VRk BSt 500 S [kN] - 22,0 31,0 42,0 55,0 86,0 135,0 169,0 221,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Non cracked concrete
Tensile NRd BSt 500 S [kN] 16,1 22,6 33,2 44,0 58,3 74,6 102,5 149,4 174,9
Shear VRd BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3
Cracked concrete
Tensile NRd BSt 500 S [kN] - 9,4 19,4 25,7 34,0 49,8 73,0 106,5 124,7
Shear VRd BSt 500 S [kN] - 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3

10 / 2012 545
Hilti HIT-HY 200
with rebar

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Non cracked concrete
Tensile Nrec BSt 500 S [kN] 11,5 16,2 23,7 31,4 41,6 53,3 73,2 106,7 125,0
Shear Vrec BSt 500 S [kN] 6,7 10,5 14,8 20,0 26,2 41,0 64,3 80,5 105,2
Cracked concrete
Tensile Nrec BSt 500 S [kN] - 6,7 13,8 18,3 24,3 35,6 52,2 76,1 89,1
Shear Vrec BSt 500 S [kN] - 10,5 14,8 20,0 26,2 41,0 64,3 80,5 105,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-HY 200 injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +80 C +50 C +80 C
Temperature range III -40 C to +120 C +72 C +120 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of rebar BSt 500S
Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Nominal
tensile BSt 500 S [N/mm] 550 550 550 550 550 550 550 550 550
strength fuk
Yield
BSt 500 S [N/mm] 500 500 500 500 500 500 500 500 500
strength fyk
Stressed
cross- BSt 500 S [mm] 50,3 78,5 113,1 153,9 201,1 314,2 490,9 615,8 804,2
section As
Moment of
resistance BSt 500 S [mm] 50,3 98,2 169,6 269,4 402,1 785,4 1534 2155 3217
W

546 10 / 2012
Hilti HIT-HY 200
with rebar

Material quality
Part Material
rebar Geometry and mechanical properties according to DIN 488-2:1986 or
BSt 500 S E DIN 488-2:2006

Setting
Installation equipment
Anchor size 8 10 12 14 16 20 25 28 32
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

Setting instruction

Bore hole drilling


Drill hole to the required embedment depth with an appropriately sized Hilti
TE-CD or TE-YD hollow drill bit with Hilti vacuum attachment. This drilling
method properly cleans the borehole and removes dust while drilling.
After drilling is complete, proceed to the injection preparation step in the
instructions for use.

Drill Hole to the required embedment depth with a hammer drill set in
rotation-hammer mode using an appropriately sized carbide drill bit.

Bore hole cleaning Just before setting an anchor, the bore hole must be free of dust and debris.

a) Manual Cleaning (MC) non-cracked concrete only


for bore hole diameters d0 20mm and bore hole depth h0 10d
The Hilti manual pump may be used for blowing out bore holes up to
diameters d0 20 mm and embedment depths up to hef 10d.
Blow out at least 4 times from the back of the bore hole until return air
stream is free of noticeable dust

Brush 4 times with the specified brush size by inserting the steel brush Hilti
HIT-RB to the back of the hole (if needed with extension) in a twisting
motion and removing it.
The brush must produce natural resistance as it enters the bore hole -- if
not the brush is too small and must be replaced with the proper brush
diameter.
Blow out again with manual pump at least 4 times until return air stream is
free of noticeable dust.

10 / 2012 547
Hilti HIT-HY 200
with rebar

b) Compressed air cleaning (CAC)


for all bore hole diameters d0 and all bore hole depth h0
Blow 2 times from the back of the hole (if needed with nozzle extension)
over the hole length with oil-free compressed air (min. 6 bar at 6 m/h) until
return air stream is free of noticeable dust. Bore hole diameter 32 mm
the compressor must supply a minimum air flow of 140 m/hour.

Brush 2 times with the specified brush size by inserting the steel brush Hilti
HIT-RB to the back of the hole (if needed with extension) in a twisting
motion and removing it.
The brush must produce natural resistance as it enters the bore hole -- if
not the brush is too small and must be replaced with the proper brush
diameter.
Blow again with compressed air 2 times until return air stream is free of
noticeable dust.

Injection preparation
Tightly attach new Hilti mixing nozzle HIT-RE-M to foil pack manifold (snug
fit). Do not modify the mixing nozzle. Observe the instruction for use of the
dispenser. Check foil pack holder for proper function. Do not use damaged
foil packs / holders. Swing foil pack holder with foil pack into HIT-
dispenser.

Discard initial adhesive. The foil pack opens automatically as dispensing is


initiated. Depending on the size of the foil pack an initial amount of
adhesive has to be discarded.
Discard quantities are
2 strokes for 330 ml foil pack,
3 strokes for 500 ml foil pack,
4 strokes for 500 ml foil pack 5C.

Inject adhesive from the back of the borehole without forming air voids
Inject the adhesive starting at the back of the hole, slowly withdrawing the
mixer with each trigger pull. Fill holes approximately 2/3 full, or as required
to ensure that the annular gap between the anchor and the concrete is
completely filled with adhesive along the embedment length.

After injection is completed, depressurize the dispenser by pressing the


release trigger. This will prevent further adhesive discharge from the mixer.

Overhead installation and installation with embedment depth hef > 250mm.
For overhead installation the injection is only possible with the aid of
extensions and piston plugs. Assemble HIT-RE-M mixer, extension(s) and
appropriately sized piston plug. Insert piston plug to back of the hole and
inject adhesive. During injection the piston plug will be naturally extruded
out of the bore hole by the adhesive pressure.

548 10 / 2012
Hilti HIT-HY 200
with rebar

Setting the element


Before use, verify that the element is dry and free of oil and other
contaminants.
Mark and set element to the required embedment depth untill working time
twork has elapsed.

For overhead installation use piston plugs and fix embedded parts with e.g.
wedges

Loading the anchor:


After required curing time tcure the anchor can be loaded.

For detailed information on installation see instruction for use given with the package of the product.

10 / 2012 549
Hilti HIT-HY 200
with rebar

Working time, curing time


Temperature Hilti HIT-HY 200-R
of the Working time in which anchor Curing time before anchor
base material can be inserted and adjusted twork can be loaded tcure
-10 C to -5 C 3 hour 20 hour
-4 C to 0 C 2 hour 7 hour
1 C to 5 C 1 hour 3 hour
6 C to 10 C 40 min 2 hour
11 C to 20 C 15 min 1 hour
21 C to 30 C 9 min 1 hour
31 C to 40 C 6 min 1 hour

Temperature Hilti HIT-HY 200-A


of the Working time in which anchor Curing time before anchor
base material can be inserted and adjusted twork can be loaded tcure
-10 C to -5 C 1,5 hour 7 hour
-4 C to 0 C 50 min 4 hour
1 C to 5 C 25 min 2 hour
6 C to 10 C 15 min 1 hour
11 C to 20 C 7 min 30 min
21 C to 30 C 4 min 30 min
31 C to 40 C 3 min 30 min

Setting details
d0

Bore hole depth h0 = embedment depth hef

Thickness of concrete member h

550 10 / 2012
Hilti HIT-HY 200
with rebar

Setting details
Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Nominal diameter of 12 14 16
d0 [mm] a) a) a) 18 20 25 32 35 40
drill bit (10) (12) (14)
Effective anchorage hef,min [mm] 60 60 70 75 80 90 100 112 128
and drill hole depth
range
b) hef,max [mm] 160 200 240 280 320 400 500 560 640
Minimum base
hmin [mm] hef + 30 mm hef + 2 d0
material thickness

Minimum spacing smin [mm] 40 50 60 70 80 100 125 140 160

Minimum edge
cmin [mm] 40 50 60 70 80 100 125 140 160
distance
Critical spacing for
scr,sp 2 ccr,sp
splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


c) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N 1,5 hef
d)
failure

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) both given values for drill bit diameter can be used
b) hef,min hef hef,max (hef: embedment depth)
c) h: base material thickness (h hmin)
d) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.

10 / 2012 551
Hilti HIT-HY 200
with rebar

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in
ETA-11/0493 issued 2012-08-08 for HIT-HY 200-A and ETA-12/0084 issued 2012-08-08 for HIT-HY 200-R. Both
mortars possess identical technical load performance.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The simplified calculated design loads take a conservative approach: They will be
lower than the exact values according to ETAG 001, TR 029. For an optimized design, anchor calculation
can be performed using PROFIS anchor design software.
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
NRd,s BSt 500 S [kN] 20,0 30,7 44,3 60,7 79,3 123,6 192,9 242,1 315,7

552 10 / 2012
Hilti HIT-HY 200
with rebar

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Typical embedment depth
80 90 110 125 145 170 210 270 300
hef,typ [mm]
Non cracked concrete
0
N Rd,p Temperature range I [kN] 16,1 22,6 33,2 44,0 58,3 85,5 131,9 190,0 241,3
0
N Rd,p Temperature range II [kN] 13,4 18,8 27,6 36,7 48,6 71,2 110,0 158,3 201,1
0
N Rd,p Temperature range III [kN] 11,4 16,0 23,5 31,2 41,3 60,5 93,5 134,6 170,9
Cracked concrete
0
N Rd,p Temperature range I [kN] - 9,4 19,4 25,7 34,0 49,8 77,0 110,8 140,7
0
N Rd,p Temperature range II [kN] - 7,5 15,2 20,2 26,7 39,2 60,5 87,1 110,6
0
N Rd,p Temperature range III [kN] - 6,6 13,8 18,3 24,3 35,6 55,0 79,2 100,5

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
0
N Rd,c Non cracked concrete [kN] 24,1 28,7 38,8 47,1 58,8 74,6 102,5 149,4 174,9
0
N Rd,c Cracked concrete [kN] - 20,5 27,7 33,5 41,9 53,2 73,0 106,5 124,7
a) Splitting resistance must only be considered for non-cracked concrete

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,1 a)
fB,p = (fck,cube/25N/mm) 1
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

10 / 2012 553
Hilti HIT-HY 200
with rebar

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


fh,N = (hef/hef,typ)1,5

Influence of reinforcement
hef [mm] 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a)
0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
VRd,s BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3

554 10 / 2012
Hilti HIT-HY 200
with rebar

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k=2
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 15,0 18,7 27,0 39,2 47,3 59,0
Cracked concrete
0
V Rd,c [kN] - 6,1 8,2 10,6 13,2 19,2 27,7 33,5 41,8

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

10 / 2012 555
Hilti HIT-HY 200
with rebar

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


hef/d 4 4,5 5 6 7 8 9 10 11
0,05 (hef / d)
1,68
f hef = 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81

hef/d 12 13 14 15 16 17 18 19 20
0,05 (hef / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

556 10 / 2012
Hilti HIT-HY 200
with rebar

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,1 = [mm] 60 60 72 84 96 120 150 168 192
Base material thickness hmin= [mm] 90 90 104 120 136 170 214 238 272
Tensile NRd: single anchor, no edge effects
Non cracked concrete
BSt 500 S [kN] 12,1 15,1 20,6 25,9 31,7 44,3 61,8 73,3 89,6
Cracked concrete
BSt 500 S [kN] - 6,3 12,7 17,2 22,5 31,5 44,1 52,3 63,9
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3
Cracked concrete
BSt 500 S [kN] - 12,6 20,7 28,0 36,7 57,3 88,2 104,5 127,7

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,1 = [mm] 60 60 72 84 96 120 150 168 192
Base material thickness hmin= [mm] 90 90 104 120 136 170 214 238 272
Edge distance c = cmin= [mm] 40 50 60 80 100 120 135 150 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non cracked concrete
BSt 500 S [kN] 7,3 9,4 12,0 16,0 20,4 27,9 37,2 43,7 50,4
Cracked concrete
BSt 500 S [kN] - 4,2 8,5 12,6 17,3 23,7 31,0 36,6 41,6
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non cracked concrete
BSt 500 S [kN] 3,5 4,9 6,7 10,3 13,7 19,3 25,2 30,2 32,0
Cracked concrete
BSt 500 S [kN] - 3,5 4,7 7,3 9,7 13,6 17,8 21,4 22,7

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,1 = [mm] 60 60 72 84 96 120 150 168 192
Base material thickness hmin= [mm] 90 90 104 120 136 170 214 238 272
Spacing s = smin= [mm] 40 50 60 80 100 120 135 150 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non cracked concrete
BSt 500 S [kN] 7,9 9,5 12,4 16,0 19,9 27,5 37,8 44,6 53,3
Cracked concrete
BSt 500 S [kN] - 4,5 8,4 11,6 15,2 21,0 28,7 33,9 40,2
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 80,4 95,1 112,9
Cracked concrete
BSt 500 S [kN] - 8,0 16,2 22,7 30,3 42,1 57,3 67,8 80,5

10 / 2012 557
Hilti HIT-HY 200
with rebar

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,typ = [mm] 80 90 110 125 145 170 210 270 300
Base material thickness hmin= [mm] 110 120 142 161 185 220 274 340 380
Tensile NRd: single anchor, no edge effects
Non cracked concrete
BSt 500 S [kN] 16,1 22,6 33,2 44,0 58,3 74,6 102,5 149,4 174,9
Cracked concrete
BSt 500 S [kN] - 9,4 19,4 25,7 34,0 49,8 73,0 106,5 124,7
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3
cracked concrete
BSt 500 S [kN] - 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,typ = [mm] 80 90 110 125 145 170 210 270 300
Base material thickness hmin= [mm] 110 120 142 161 185 220 274 340 380
Edge distance c = cmin= [mm] 40 50 60 80 100 120 135 150 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non cracked concrete
BSt 500 S [kN] 9,2 12,9 18,6 23,7 30,4 38,9 51,7 72,0 81,9
Cracked concrete
BSt 500 S [kN] - 5,4 11,1 15,6 21,6 31,0 43,2 59,2 66,5
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non cracked concrete
BSt 500 S [kN] 3,7 5,3 7,3 11,2 15,8 21,5 27,5 34,3 36,5
Cracked concrete
BSt 500 S [kN] - 3,8 5,2 7,9 11,2 15,2 19,5 24,3 25,8

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,typ = [mm] 80 90 110 125 145 170 210 270 300
Base material thickness hmin= [mm] 110 120 142 161 185 220 274 340 380
Spacing s = smin= [mm] 40 50 60 80 100 120 135 150 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non cracked concrete
BSt 500 S [kN] 10,6 14,5 20,8 26,9 33,9 43,1 58,5 83,9 97,1
Cracked concrete
BSt 500 S [kN] - 6,5 12,7 16,9 22,4 31,5 44,3 63,1 72,7
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3
Cracked concrete
BSt 500 S [kN] - 14,7 20,7 28,0 36,7 57,3 88,7 112,7 145,5

558 10 / 2012
Hilti HIT-HY 200
with rebar

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,2 = [mm] 96 120 144 168 192 240 300 336 384
Base material thickness hmin= [mm] 126 150 176 204 232 290 364 406 464
Tensile NRd: single anchor, no edge effects
Non cracked concrete
BSt 500 S [kN] 19,3 30,2 43,4 59,1 77,2 120,6 174,9 207,4 253,3
Cracked concrete
BSt 500 S [kN] - 12,6 25,3 34,5 45,0 70,4 110,0 137,9 180,2
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3
Cracked concrete
BSt 500 S [kN] - 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,2 = [mm] 96 120 144 168 192 240 300 336 384
Base material thickness hmin= [mm] 126 150 176 204 232 290 364 406 464
Edge distance c = cmin= [mm] 40 50 60 80 100 120 135 150 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non cracked concrete
BSt 500 S [kN] 11,0 17,2 24,8 33,9 42,4 58,6 79,7 94,3 111,7
Cracked concrete
BSt 500 S [kN] - 7,2 14,5 20,9 28,5 43,7 64,0 75,7 88,6
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non cracked and cracked concrete
BSt 500 S [kN] 3,9 5,7 7,8 12,0 16,9 23,6 30,5 36,7 39,6
Cracked concrete
BSt 500 S [kN] - 4,0 5,5 8,5 12,0 16,7 21,6 26,0 28,1

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I


(load values are valid for single anchor)
Data according ETA-11/0493 and ETA-12/0084, issue 2012-02-06
Anchor size 8 10 12 14 16 20 25 28 32
Embedment depth hef,2 = [mm] 96 120 144 168 192 240 300 336 384
Base material thickness hmin= [mm] 126 150 176 204 232 290 364 406 464
Spacing s = smin= [mm] 40 50 60 80 100 120 135 150 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non cracked concrete
BSt 500 S [kN] 12,9 19,9 28,1 38,4 49,9 69,5 96,2 113,9 137,6
Cracked concrete
BSt 500 S [kN] - 8,8 17,0 23,3 30,5 46,3 69,3 84,9 102,1
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0 112,7 147,3
Cracked concrete
BSt 500 S [kN] - 14,3 20,7 28,0 36,7 57,3 90,0 112,7 147,3

10 / 2012 559
Hilti HIT-HY 150 MAX
with HIT-TZ

Hilti HIT-HY 150 MAX with HIT-TZ


Injection mortar system Benefits

Hilti HIT- - suitable for cracked and non-


HY 150 MAX cracked concrete C 20/25 to
330 ml foil pack C 50/60
(also available - hammer drilled and diamond
as 500 ml cored bore holes
and 1400 ml - high loading capacity
foil pack) - suitable for dry and water
saturated concrete
Statik mixer - under water application
- No cleaning required
HIT-TZ
HIT-RTZ rod

PROFIS
European
Tensile Corrosion CE Anchor
Concrete Technical
zone resistance conformity design
Approval
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
a)
European technical approval DIBt, Berlin ETA-04/0084 / 2009-12-09
a) All data given in this section according ETA-04/0084, issue 2009-12-09.

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- Embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +50C/80C)
- Installation temperature range +5C to +40C

560 10 / 2012
Hilti HIT-HY 150 MAX
with HIT-TZ

Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended
loads.
Anchor size M8 M10 M12 M16 M20
Embedment depth [mm] 55 65 75 90 120
Base material thickness [mm] 110 130 150 180 240

Mean ultimate resistance a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-TZ
Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
Tensile NRu,m HIT-TZ [kN] 21,3 26,7 33,3 57,5 88,5
Shear VRu,m HIT-TZ [kN] 11,6 17,9 26,3 49,4 77,7
Cracked concrete
Tensile NRu,m HIT-TZ [kN] 12,0 21,3 26,7 40,0 53,3
Shear VRu,m HIT-TZ [kN] 12,0 17,9 26,3 49,4 77,7

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-TZ


Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
Tensile NRk HIT-TZ [kN] 16,0 20,0 25,0 43,1 66,4
Shear VRk HIT-TZ [kN] 11,0 17,0 25,0 47,0 74,0
Cracked concrete
Tensile NRk HIT-TZ [kN] 9,0 16,0 20,0 30,0 40,0
Shear VRk HIT-TZ [kN] 9,0 17,0 25,0 47,0 74,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-TZ


Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
Tensile NRd HIT-TZ [kN] 10,7 13,3 16,7 28,7 44,3
Shear VRd HIT-TZ [kN] 8,8 13,6 20,0 37,6 59,2
Cracked concrete
Tensile NRd HIT-TZ [kN] 6,0 10,7 13,3 20,0 26,7
Shear VRd HIT-TZ [kN] 6,0 13,6 20,0 37,6 53,3

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-TZ


Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
Tensile Nrec HIT-TZ [kN] 7,6 9,5 11,9 20,5 31,6
Shear Vrec HIT-TZ [kN] 6,3 9,7 14,3 26,9 42,3
Cracked concrete
Tensile Nrec HIT-TZ [kN] 4,3 7,6 9,5 14,3 19,0
Shear Vrec HIT-TZ [kN] 4,3 9,7 14,3 26,9 38,1
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

10 / 2012 561
Hilti HIT-HY 150 MAX
with HIT-TZ

Service temperature range


Hilti HIT-HY 150 MAX injection mortar with anchor rod HIT-TZ may be applied in the temperature ranges given
below. An elevated base material temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +80 C +50 C +80 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of HIT-(R)TZ
Anchor size M8 M10 M12 M16 M20
Nominal HIT-TZ [N/mm] 600 600 600 600 600
tensile
strength fuk HIT-RTZ [N/mm] 600 600 600 600 600
Yield HIT-TZ [N/mm] 480 480 480 480 480
strength fyk HIT-RTZ [N/mm] 480 480 480 480 480
Stressed
cross- HIT-TZ [mm] 36,6 58,0 84,3 157 245
section As
Moment of
HIT-TZ [mm] 31,9 62,5 109,7 278 542
resistance W

Material quality
Part Material
C-steel cold formed
HIT-TZ
steel galvanized 5m
stainless steel cold formed
HIT-RTZ
1.4404 and 1.4401

Anchor dimensions
Anchor size M8 M10 M12 M16 M20
HIT-(R)TZ M8x55 M10x65 M12x75 M16x90 M20x120
Anchor embedment depth [mm] 55 65 75 90 120

Setting
installation equipment
Anchor size M8 M10 M12 M16 M20
Rotary hammer TE 2 TE 16 TE 40 - TE 70

562 10 / 2012
Hilti HIT-HY 150 MAX
with HIT-TZ

Setting instruction

Dry, water-saturated concrete, under water, hammer drilling and diamond coring

1. Diamond coring is permissible only when the Hilti DD EC-1 diamond core drilling machine and the
corresponding DD-C core bit are used.
2. Check the setting depth and compress the drilling dust. It is not necessary to clean the hole.
3. For use with Hilti HIT-HY 150 / Hilti HIT-HY 150 MAX. Read the instructions before use.

For detailed information on installation see instruction for use given with the package of the product.

Curing time for general conditions


Temperature Curing time before anchor
of the base material can be fully loaded tcure
30 C to 40 C 30 min
20 C to <30 C 30 min
5 C to <20 C 60 min

10 / 2012 563
Hilti HIT-HY 150 MAX
with HIT-TZ

Setting details
Anchor size M8 M10 M12 M16 M20
Nominal diameter of
d0 [mm] 10 12 14 18 22
drill bit
Diameter of element d [mm] 8 10 12 16 20
Effective anchorage
hef [mm] 55 65 75 90 120
depth
Drill hole depth h0 [mm] 60 70 80 95 125
Minimum base a)
hmin [mm] 110 130 150 180 240
material thickness
Diameter of clearance
df [mm] 9 12 14 18 22
hole in the fixture
Non cracked concrete
Minimum spacing smin [mm] 40 50 55 70 80
for c [mm] 50 70 75 80 90
Minimum edge
cmin [mm] 40 50 55 70 80
distance
for s [mm] 70 80 85 85 90
Cracked concrete
Minimum spacing smin [mm] 40 60 70 80 100
for c [mm] 65 85 100 100 120
Minimum edge
cmin [mm] 50 60 70 80 100
distance
for s [mm] 80 120 130 140 150
Critical spacing for
scr,sp [mm] 2 ccr,sp
splitting failure
Critical edge distance
ccr,sp [mm] 2 hef
for splitting failure
Critical spacing for
scr,N 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N 1,5 hef
failure
Torque moment Tinst [Nm] 12 23 40 70 130

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) h: base material thickness (h hmin)

564 10 / 2012
Hilti HIT-HY 150 MAX
with HIT-TZ

Simplified design method


Simplified version of the design method according ETAG 001, Annex C. Design resistance according data given in
ETA-04/0084, issue 2009-12-09.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, Annex C. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p fh,p
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp f h,sp fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Anchor size M8 M10 M12 M16 M20
NRd,s HIT-TZ [kN] 14,7 23,3 34,0 62,7 98,0

Design combined pull-out and concrete cone resistance NRd,p = N0Rd,p fB,p fh,p
Anchor size M8 M10 M12 M16 M20
Embedment depth hef [mm] 55 65 75 90 120
Non-cracked concrete
0
N Rd,p Temperature range I [kN] 10,7 13,3 16,7 28,7 44,3
Cracked concrete
0
N Rd,p Temperature range I [kN] 6,0 10,7 13,3 20,0 26,7

Design concrete cone resistance a) NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f h,N f1,sp f2,sp f3,sp fre,N
Anchor size M8 M10 M12 M16 M20
0
N Rd,c Non cracked concrete [kN] 13,7 17,6 21,9 28,7 44,3
0
N Rd,c Cracked concrete [kN] 9,8 12,6 15,6 20,5 31,5

10 / 2012 565
Hilti HIT-HY 150 MAX
with HIT-TZ

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0.1 a)
fB,p = (fck,cube/25N/mm) 1 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hef/hef,typ)

Influence of reinforcement
hef [mm] 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a)
0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.

566 10 / 2012
Hilti HIT-HY 150 MAX
with HIT-TZ

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Anchor size M8 M10 M12 M16 M20
VRd,s HIT-(R)TZ [kN] 8,8 13,6 20,0 37,6 59,2

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance a) VRd,c = V0Rd,c fB f f h f4


Non-cracked concrete Cracked concrete
Anchor size M8 M10 M12 M16 M20 M8 M10 M12 M16 M20
0
V Rd,c [kN] 3,1 4,5 6,1 8,5 13,4 1,6 2,4 3,1 5,0 6,9
a) For anchor groups only the anchors close to the edge must be considered.

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
2/3
fh = 0,22 0,34 0,45 0,54 0,63 0,71 0,79 0,86 0,93 1,00

10 / 2012 567
Hilti HIT-HY 150 MAX
with HIT-TZ

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

568 10 / 2012
Hilti HIT-HY 150 MAX
with HIT-TZ

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 55 65 75 90 120
Base material thickness hmin= [mm] 110 130 150 180 240
Tensile NRd: single anchor, no edge effects
Non-cracked concrete
HIT-(R)TZ [kN] 10,7 13,3 16,7 28,7 44,3
Cracked concrete
HIT-(R)TZ [kN] 6,0 10,7 13,3 20,0 26,7
Shear VRd: single anchor, no edge effects, without lever arm
Non-cracked concrete
HIT-(R)TZ [kN] 8,8 13,6 20,0 37,6 59,2
Cracked concrete
HIT-(R)TZ [kN] 6,0 13,6 20,0 37,6 53,3

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 55 65 75 90 120
Base material thickness hmin= [mm] 110 130 150 180 240
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non-cracked concrete
cmin [mm] 50 60 70 80 100
HIT-(R)TZ [kN] 6,5 8,2 10,3 17,3 25,9
Cracked concrete
cmin [mm] 40 50 55 70 80
HIT-(R)TZ [kN] 3,3 6,0 7,4 11,3 14,2
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non-cracked concrete
cmin [mm] 50 60 70 80 100
HIT-(R)TZ [kN] 3,1 4,5 6,1 8,5 13,4
Cracked concrete
cmin [mm] 40 50 55 70 80
HIT-(R)TZ [kN] 1,6 2,4 3,1 5,0 6,9

10 / 2012 569
Hilti HIT-HY 150 MAX
with HIT-TZ

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 55 65 75 90 120
Base material thickness hmin= [mm] 110 130 150 180 240
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non-cracked concrete
smin [mm] 40 60 70 80 100
HIT-(R)TZ [kN] 6,3 8,2 10,3 17,6 26,7
Cracked concrete
smin [mm] 40 50 55 70 80
HIT-(R)TZ [kN] 3,5 6,4 7,9 11,9 15,6
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non-cracked concrete
smin [mm] 40 60 70 80 100
HIT-(R)TZ [kN] 6,6 13,6 20,0 37,3 56,5
Cracked concrete
smin [mm] 40 50 55 70 80
HIT-(R)TZ [kN] 3,7 13,4 16,6 25,2 32,6

570 10 / 2012
Hilti HIT-HY 150 MAX
with HIT-TZ

10 / 2012 571
Hilti HIT-HY 150 MAX
with HIT-V / HAS

Hilti HIT-HY 150 MAX with HIT-V / HAS


Injection mortar system Benefits

Hilti HIT- - suitable for non-cracked concrete


HY 150 MAX and cracked concrete
330 ml foil pack C 20/25 to C 50/60
(also available - suitable for dry and water
as 500 ml saturated concrete
and 1400 ml
- high loading capacity
foil pack)
- rapid curing
- small edge distance and anchor
Static mixer spacing possible
- large diameter applications
HAS rods - high corrosion resistant
HAS-R rods - in service temperature range up
HAS-HCR rods to 120C short term/
72C long term
HAS-E rods - manual cleaning for anchor size
HAS-E-R rods M8 to M16 and embedment depth
hef 10d for non-cracked
concrete only
HIT-V rods
HIT-V-R rods - embedment depth range:
HIT-V-HCR rods from 60 ... 160 mm for M8
to 120 ... 600 mm for M30

PROFIS
Small edge Variable High European
Tensile Corrosion CE Anchor
Concrete distance embedment corrosion Technical
zone resistance conformity design
and spacing depth resistance Approval
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
a)
European technical approval DIBt, Berlin ETA-08/0352 / 2010-04-01
Fire test report MFPA, Leipzig GS 3.2/09-121 / 2011-08-19
a) All data given in this section according ETA-08/0352 issue 2010-04-01.

572 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range -10C to +40C

Embedment depth a) and base material thickness for the basic loading data. Mean
ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth hef [mm] 80 90 110 125 170 210 240 270
Base material thickness h [mm] 110 120 140 165 220 270 300 340
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.

Mean ultimate resistance: concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non-cracked concrete
Tensile NRu,m HIT-V 5.8 [kN] 18,9 30,5 44,1 83,0 129,2 185,9 241,5 288,4
Shear VRu,m HIT-V 5.8 [kN] 9,5 15,8 22,1 41,0 64,1 92,4 120,8 147,0
Cracked concrete
Tensile NRu,m HIT-V 5.8 [kN] - 20,7 30,4 50,3 85,5 126,7 - -
Shear VRu,m HIT-V 5.8 [kN] - 15,8 22,1 41,0 64,1 92,4 - -

Characteristic resistance: concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non-cracked concrete
Tensile NRk HIT-V 5.8 [kN] 18,0 29,0 42,0 70,6 111,9 153,7 187,8 216,3
Shear VRk HIT-V 5.8 [kN] 9,0 15,0 21,0 39,0 61,0 88,0 115,0 140,0
Cracked concrete
Tensile NRk HIT-V 5.8 [kN] - 15,6 22,8 37,7 64,1 95,0 - -
Shear VRk HIT-V 5.8 [kN] - 15,0 21,0 39,0 61,0 88,0 - -

Design resistance: concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non-cracked concrete
Tensile NRd HIT-V 5.8 [kN] 12,0 19,3 28,0 47,1 74,6 102,5 125,2 120,2
Shear VRd HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
Cracked concrete
Tensile NRd HIT-V 5.8 [kN] - 10,4 15,2 25,1 42,7 63,3 - -
Shear VRd HIT-V 5.8 [kN] - 12,0 16,8 31,2 48,8 70,4 - -

10 / 2012 573
Hilti HIT-HY 150 MAX
with HIT-V / HAS

Recommended loads a): concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non-cracked concrete
Tensile Nrec HIT-V 5.8 [kN] 8,6 13,8 20,0 33,6 53,3 73,2 89,4 85,8
Shear Vrec HIT-V 5.8 [kN] 5,1 8,6 12,0 22,3 34,9 50,3 65,7 80,0
Cracked concrete
Tensile Nrec HIT-V 5.8 [kN] - 7,4 10,9 18,0 30,5 45,2 - -
Shear Vrec HIT-V 5.8 [kN] - 8,6 12,0 22,3 34,9 50,3 - -
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-HY 150 MAX injection mortar may be applied in the temperature ranges given below. An elevated base
material temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +80 C +50 C +80 C
Temperature range III -40 C to +120 C +72 C +120 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of HIT-V / HAS
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HIT-V/HAS 5.8 [N/mm] 500 500 500 500 500 500 500 500
Nominal HIT-V/HAS 8.8 [N/mm] 800 800 800 800 800 800 800 800
tensile
strength fuk HIT-V/HAS -R [N/mm] 700 700 700 700 700 700 500 500
HIT-V/HAS -HCR [N/mm] 800 800 800 800 800 700 700 700
HIT-V/HAS 5.8 [N/mm] 400 400 400 400 400 400 400 400
Yield HIT-V/HAS 8.8 [N/mm] 640 640 640 640 640 640 640 640
strength fyk HIT-V/HAS -R [N/mm] 450 450 450 450 450 450 210 210
HIT-V/HAS -HCR [N/mm] 600 600 600 600 600 400 400 400
Stressed HAS [mm] 32,8 52,3 76,2 144 225 324 427 519
cross-
section As HIT-V [mm] 36,6 58,0 84,3 157 245 353 459 561
Moment of HAS [mm] 27,0 54,1 93,8 244 474 809 1274 1706
resistance
W HIT-V [mm] 31,2 62,3 109 277 541 935 1387 1874

574 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

Material quality
Part Material
Threaded rod Strength class 5.8, A5 > 8% ductile
HIT-V(F), steel galvanized 5 m,
HAS 5.8: M8 M24 (F) hot dipped galvanized 45 m,
Threaded rod Strength class 8.8, A5 > 8% ductile
HIT-V(F), steel galvanized 5 m,
HAS 8.8 M27 M30 (F) hot dipped galvanized 45 m,
Stainless steel grade A4, A5 > 8% ductile
Threaded rod
strength class 70 for M24 and class 50 for M27 to M30, 1.4401; 1.4404;
HIT-V-R, HAS-R
1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, 1.4529; 1.4565
Threaded rod
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
HIT-V-HCR, HAS-HCR
M24 to M30: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, hot dipped galvanized,
Washer
Stainless steel, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
ISO 7089
High corrosion resistant steel, 1.4529; 1.4565
Strength class 8,
steel galvanized 5 m,
hot dipped galvanized 45 m,
Nut
Strength class 70, stainless steel grade A4,
EN ISO 4032
1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, high corrosion resistant steel,
1.4529; 1.4565

Anchor dimensions
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
M12x110

M16x125

M20x170

M24x210

M27x240

M30x270
M10x90

Anchor rod
M8x80

HAS, HAS-R, HAS-HCR


HAS-E, HAS-E-R

Embedment depth hef [mm] 80 90 110 125 170 210 240 270
Anchor rod
Anchor rods HIT-V (-R / -HCR) are available in variable length
HIT-V, HIT-V-R, HIT-V-HCR

Setting
installation equipment
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

10 / 2012 575
Hilti HIT-HY 150 MAX
with HIT-V / HAS

Setting instruction

Dry and water-saturated concrete, hammer drilling

a)

b)

a) Note: Manual cleaning for non-cracked concrete, element sizes d 16mm and embedment depth
hef 10 d only!
b) Note: Extension and piston plug needed for overhead installation and/or embedment depth > 250mm!

For detailed information on installation see instruction for use given with the package of the product.

576 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

Working time, Curing time


Temperature Working time Curing time
of the base material TBM tgel tcure
-10 C TBM < -5 C 180 min 12 h
-5 C TBM < 0 C 40 min 4 h
0 C TBM < 5 C 20 min 2 h
5 C TBM < 20 C 8 min 1 h
20 C TBM < 30 C 5 min 30 min
30 C TBM 40 C 2 min 30 min

Setting details
Marking of the
embedment depth
d0

df

Fixture
Bore hole depth h0 = anchorage depth hef Thickness tfix

Thickness of concrete member h

10 / 2012 577
Hilti HIT-HY 150 MAX
with HIT-V / HAS

Setting details
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Nominal diameter of
d0 [mm] 10 12 14 18 24 28 30 35
drill bit
Effective embedment and hef,min [mm] 60 60 70 80 90 100 110 120
drill hole depth range
a)

for HIT-V hef,max [mm] 160 200 240 320 400 480 540 600
Effective anchorage and
drill hole depth hef [mm] 80 90 110 125 170 210 240 270
for HAS
Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness 100 mm
Diameter of clearance
df [mm] 9 12 14 18 22 26 30 33
hole in the fixture
b)
Torque moment Tmax [Nm] 10 20 40 80 150 200 270 300
Minimum spacing smin [mm] 40 50 60 80 100 120 135 150
Minimum edge
cmin [mm] 40 50 60 80 100 120 135 150
distance
Critical spacing
scr,sp [mm] 2 ccr,sp
for splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


c) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N [mm] 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N [mm] 1,5 hef
d)
failure

For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a) Embedment depth range: hef,min hef hef,max
b) Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing
and/or edge distance.
c) h: base material thickness (h hmin), hef: embedment depth
d) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.

578 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in
ETA-08/0352, issue 2010-04-01.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

TENSION loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HAS 5.8 [kN] 11,3 17,3 25,3 48,0 74,7 106,7 - -
HIT-V 5.8 [kN] 12,0 19,3 28,0 52,7 82,0 118,0 153,3 187,3
HAS 8.8 [kN] - - - - - - 231,3 281,3
HIT-V 8.8 [kN] 19,3 30,7 44,7 84,0 130,7 188,0 244,7 299,3
NRd,s
HAS (-E)-R [kN] 12,3 19,8 28,3 54,0 84,0 119,8 75,9 92,0
HIT-V-R [kN] 13,9 21,9 31,6 58,8 92,0 132,1 80,4 98,3
HAS (-E)-HCR [kN] 18,0 28,0 40,7 76,7 120,0 106,7 144,8 175,7
HIT-V-HCR [kN] 19,3 30,7 44,7 84,0 130,7 117,6 152,9 187,1

10 / 2012 579
Hilti HIT-HY 150 MAX
with HIT-V / HAS

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth
80 90 110 125 170 210 240 270
hef = hef,typ [mm]
Non-cracked concrete
0
N Rd,p Temperature range I [kN] 15,6 22,0 32,3 54,5 85,5 116,1 135,7 120,2
0
N Rd,p Temperature range II [kN] 13,4 18,8 27,6 50,3 78,3 105,6 122,1 99,0
0
N Rd,p Temperature range III [kN] 8,9 12,6 18,4 29,3 46,3 63,3 74,6 63,6
Cracked concrete
0
N Rd,p Temperature range I [kN] - 10,4 15,2 25,1 42,7 63,3 - -
0
N Rd,p Temperature range II [kN] - 8,5 13,8 23,0 42,7 63,3 - -
0
N Rd,p Temperature range III [kN] - 5,7 8,3 14,7 24,9 42,2 - -

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
0
N Rd,c Non-cracked concrete [kN] 20,1 24,0 32,4 47,1 74,6 102,5 125,2 124,5
0
N Rd,c Cracked concrete [kN] - 20,5 27,7 33,5 53,2 73,0 - -
a) Splitting resistance must only be considered for non-cracked concrete.

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,10 a)
fB,p = (fck,cube/25N/mm) 1,00 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,5 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N 1
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp 1

f2,N = 0,5(1 + c/ccr,N) 1


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp) 1
a) The edge distance shall not be smaller than the minimum edge distance cmin. These influencing factors must
be considered for every edge distance smaller than the critical edge distance.

580 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N) 1
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp) 1
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin. This influencing factor must
be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hef/hef,typ)

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.

SHEAR loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s

- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c


fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HAS 5.8 [kN] 6,8 10,4 15,2 28,8 44,8 64,0 - -
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HAS 8.8 [kN] - - - - - - 139,2 168,8
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
VRd,s
HAS (-E)-R [kN] 7,7 12,2 17,3 32,7 50,6 71,8 45,8 55,5
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HAS (-E)-HCR [kN] 10,4 16,8 24,8 46,4 72,0 64,0 86,9 105,7
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

10 / 2012 581
Hilti HIT-HY 150 MAX
with HIT-V / HAS

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 18,7 27,0 36,6 44,5 53,0
Cracked concrete
0
V Rd,c [kN] - 6,1 8,2 13,2 19,2 25,9 31,5 -

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

582 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


hef/d 4 4,5 5 6 7 8 9 10 11
0,05 (hef / d)
1,68
f hef = 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81

hef/d 12 13 14 15 16 17 18 19 20
0,05 (hef / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined TENSION and SHEAR loading


For combined tension and shear loading see section Anchor Design.

10 / 2012 583
Hilti HIT-HY 150 MAX
with HIT-V / HAS

Precalculated values design resistance values


All data applies to:
- non-cracked concrete C 20/25 fck,cube =25 N/mm
- temperature range I (see service temperature range)
- minimum thickness of base material
- no effects of dense reinforcement

Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - minimum embedment depth


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,min [mm] 60 60 70 80 90 100 110 120
Base material thickness h = hmin [mm] 100 100 100 116 138 156 170 190
Tensile NRd: single anchor, no edge effects
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 11,7 13,0 16,4 24,1 28,7 33,7 38,8 36,9
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] - 6,9 9,7 16,1 20,5 24,0 - -
HIT-V-R / -HCR
Shear VRd: single anchor, no edge effects, without lever arm
Non-cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 67,3 77,7 88,5
HIT-V 8.8 [kN] 12,0 18,4 27,2 48,2 57,5 67,3 77,7 88,5
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 67,3 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 48,2 57,5 67,3 77,7 88,5
Cracked concrete
HIT-V 5.8 [kN] - 12,0 16,8 31,2 41,0 48,0 - -
HIT-V 8.8 [kN] - 13,8 19,4 32,2 41,0 48,0 - -
HIT-V-R [kN] - 12,8 19,2 32,2 41,0 48,0 - -
HIT-V-HCR [kN] - 13,8 19,4 32,2 41,0 48,0 - -

584 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - minimum embedment depth


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,min [mm] 60 60 70 80 90 100 110 120
Base material thickness h = hmin [mm] 100 100 100 116 138 156 170 190
Edge distance c = cmin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 7,1 8,5 9,7 15,4 20,3 25,3 29,4 28,9
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] - 4,7 6,6 12,1 16,4 20,3 - -
HIT-V-R / -HCR
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 3,5 4,9 6,6 10,2 14,1 18,3 21,8 25,9
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] - 3,5 4,7 7,2 10,0 12,9 - -
HIT-V-R / -HCR

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - minimum embedment depth


(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,min [mm] 60 60 70 80 90 100 110 120
Base material thickness h = hmin [mm] 100 100 100 116 138 156 170 190
Spacing s = smin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 7,4 8,2 10,0 15,1 18,7 22,5 26,0 25,0
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] - 4,9 6,7 10,7 13,3 16,0 - -
HIT-V-R / -HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
Non-cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 39,4 47,1 54,7 62,7
HIT-V 8.8 [kN] 12,0 18,4 25,4 32,1 39,4 47,1 54,7 62,7
HIT-V-R [kN] 8,3 12,8 19,2 32,1 39,4 47,1 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 25,4 32,1 39,4 47,1 54,7 62,7
Cracked concrete
HIT-V 5.8 / 8.8
[kN] - 8,8 12,4 21,4 28,1 33,6 - -
HIT-V-R / -HCR

10 / 2012 585
Hilti HIT-HY 150 MAX
with HIT-V / HAS

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - typical embedment depth


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,typ [mm] 80 90 110 125 170 210 240 270
Base material thickness h = hmin [mm] 110 120 140 161 218 266 300 340
Tensile NRd: single anchor, no edge effects
Non-cracked concrete
HIT-V 5.8 [kN] 12,0 19,3 28,0 47,1 74,6 102,5 125,2 120,2
HIT-V 8.8 [kN] 15,6 22,0 32,3 47,1 74,6 102,5 125,2 120,2
HIT-V-R [kN] 13,9 21,9 31,6 47,1 74,6 102,5 80,4 98,3
HIT-V-HCR [kN] 15,6 22,0 32,3 47,1 74,6 102,5 125,2 120,2
Cracked concrete
HIT-V 5.8 / 8.8
[kN] - 10,4 15,2 25,1 42,7 63,3 - -
HIT-V-R / -HCR
Shear VRd: single anchor, no edge effects, without lever arm
Non-cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0
Cracked concrete
HIT-V 5.8 [kN] - 12,0 16,8 31,2 48,8 70,4 - -
HIT-V 8.8 [kN] - 18,4 27,2 50,3 78,4 112,8 - -
HIT-V-R [kN] - 12,8 19,2 35,3 55,1 79,5 - -
HIT-V-HCR [kN] - 18,4 27,2 50,3 78,4 70,9 - -

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - typical embedment depth


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,typ [mm] 80 90 110 125 170 210 240 270
Base material thickness h = hmin [mm] 110 120 140 161 218 266 300 340
Edge distance c = cmin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 8,6 11,6 15,5 23,7 36,6 49,8 60,6 60,0
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] - 5,8 8,4 14,8 24,4 36,9 - -
HIT-V-R / -HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 3,7 5,3 7,3 11,5 17,2 23,6 29,0 34,8
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] - 3,8 5,2 8,1 12,2 16,7 - -
HIT-V-R / -HCR

586 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - typical embedment depth


(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,typ [mm] 80 90 110 125 170 210 240 270
Base material thickness h = hmin [mm] 110 120 140 161 218 266 300 340
Spacing s [mm] 40 50 60 80 100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 9,9 13,4 18,1 26,9 42,2 57,7 70,4 69,9
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] - 7,1 10,3 16,5 27,3 39,9 - -
HIT-V-R / -HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
Non-cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 170,9
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0
Cracked concrete
HIT-V 5.8 [kN] - 12,0 16,8 30,5 48,8 70,4 - -
HIT-V 8.8 [kN] - 12,3 18,0 30,5 51,1 75,4 - -
HIT-V-R [kN] - 12,3 18,0 30,5 51,1 75,4 - -
HIT-V-HCR [kN] - 12,3 18,0 30,5 51,1 70,9 - -
a)
Design resistance: concrete C 20/25 fck,cube = 25 N/mm - embedment depth = 12 d
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288 324 360
Base material thickness h = hmin [mm] 126 150 174 228 288 344 384 430
Tensile NRd: single anchor, no edge effects
Non-cracked concrete
HIT-V 5.8 [kN] 12,0 19,3 28,0 52,7 82,0 118,0 153,3 160,2
HIT-V 8.8 [kN] 18,8 29,3 42,2 83,6 120,6 159,2 183,2 160,2
HIT-V-R [kN] 13,9 21,9 31,6 58,8 92,0 132,1 80,4 98,3
HIT-V-HCR [kN] 18,8 29,3 42,2 83,6 120,6 117,6 152,9 160,2
Cracked concrete
HIT-V 5.8 / 8.8
[kN] - 13,8 19,9 38,6 60,3 86,9 - -
HIT-V-R / -HCR
Shear VRd: single anchor, no edge effects, without lever arm
Non-cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0
Cracked concrete
HIT-V 5.8 [kN] - 12,0 16,8 31,2 48,8 70,4 - -
HIT-V 8.8 [kN] - 18,4 27,2 50,4 78,4 112,8 - -
HIT-V-R [kN] - 12,8 19,2 35,3 55,1 79,5 - -
HIT-V-HCR [kN] - 18,4 27,2 50,4 78,4 70,9 - -
a) d = element diameter

10 / 2012 587
Hilti HIT-HY 150 MAX
with HIT-V / HAS

a)
Design resistance: concrete C 20/25 fck,cube = 25 N/mm - embedment depth = 12 d
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288 324 360
Base material thickness h = hmin [mm] 126 150 174 228 288 344 384 430
Edge distance c = cmin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non-cracked concrete
HIT-V 5.8 [kN] 10,4 16,2 21,7 40,1 56,0 73,6 87,8 85,7
HIT-V 8.8 [kN] 10,4 16,2 21,7 40,1 56,0 73,6 87,8 85,7
HIT-V-R [kN] 10,4 16,2 21,7 40,1 56,0 73,6 80,4 85,7
HIT-V-HCR [kN] 10,4 16,2 21,7 40,1 56,0 73,6 87,8 85,7
Cracked concrete
HIT-V 5.8 / 8.8
[kN] - 7,6 11,0 21,7 34,4 50,6 - -
HIT-V-R / -HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non-cracked concrete
HIT-V 5.8 / 8.8
[kN] 3,9 5,7 7,8 12,9 18,9 25,9 31,8 38,1
HIT-V-R / -HCR
Cracked concrete
HIT-V 5.8 / 8.8
[kN] - 4,0 5,5 9,1 13,4 18,4 - -
HIT-V-R / -HCR
a) d = element diameter
a)
Design resistance: concrete C 20/25 fck,cube = 25 N/mm - embedment depth = 12 d
(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288 324 360
Base material thickness h = hmin [mm] 126 150 174 228 288 344 384 430
Spacing s=smin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non-cracked concrete
HIT-V 5.8 [kN] 12,0 18,5 26,0 48,9 68,4 89,9 107,2 103,8
HIT-V 8.8 [kN] 12,1 18,5 26,0 48,9 68,4 89,9 107,2 103,8
HIT-V-R [kN] 12,1 18,5 26,0 48,9 68,4 89,9 80,4 98,3
HIT-V-HCR [kN] 12,1 18,5 26,0 48,9 68,4 89,9 107,2 103,8
Cracked concrete
HIT-V 5.8 / 8.8
[kN] - 9,6 13,6 25,8 39,8 56,7 - -
HIT-V-R / -HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non-cracked concrete
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0
Cracked concrete
HIT-V 5.8 [kN] - 12,0 16,8 31,2 48,8 70,4 - -
HIT-V 8.8 [kN] - 15,7 22,7 44,0 68,7 98,9 - -
HIT-V-R [kN] - 12,8 19,2 35,3 55,1 79,5 - -
HIT-V-HCR [kN] - 15,7 22,7 44,0 68,7 70,9 - -
a) d = element diameter

588 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

10 / 2012 589
Hilti HIT-HY 150 MAX
with HIS-(R)N

Hilti HIT-HY 150 MAX with HIS-(R)N


Injection mortar system Benefits

- suitable for non-cracked concrete


Hilti HIT-
HY 150 MAX C 20/25 to C 50/60
330 ml foil pack - suitable for dry and water
(also available saturated concrete
as 500 ml - high loading capacity
and 1400 ml - rapid curing
foil pack) - small edge distance and anchor
spacing possible
- corrosion resistant
Static mixer
- in service temperature range up
to 120C short term/72C long
Internal term
threaded sleeve
HIS-N - manual cleaning for anchor size
HIS-RN M8 and M10

PROFIS
Small edge European
Corrosion CE Anchor
Concrete distance Technical
resistance conformity design
and spacing Approval
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
a)
European technical approval DIBt, Berlin ETA-08/0352 / 2010-04-01
a) All data given in this section according ETA-08/0352 issue 2010-04-01

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range -10C to +40C

590 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

Embedment depth and base material thickness for the basic loading data. Mean
ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
Base material thickness h [mm] 120 150 170 230 270

Mean ultimate resistance: non-cracked concrete C 20/25 , anchor HIS-N


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Tensile NRu,m HIS-N [kN] 26,3 48,3 70,4 123,9 114,5
Shear VRu,m HIS-N [kN] 13,7 24,2 41,0 62,0 57,8

Characteristic resistance: non-cracked concrete C 20/25 , anchor HIS-N


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Tensile NRk HIS-N [kN] 25,0 46,0 67,0 95,0 109,0
Shear VRk HIS-N [kN] 13,0 23,0 39,0 59,0 55,0

Design resistance: non-cracked concrete C 20/25 , anchor HIS-N


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Tensile NRd HIS-N [kN] 17,5 26,7 40,0 62,2 74,1
Shear VRd HIS-N [kN] 10,4 18,4 26,0 39,3 36,7

Recommended loads a): non-cracked concrete C 20/25 , anchor HIS-N


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Tensile Nrec HIS-N [kN] 12,5 19,8 31,9 45,2 53,0
Shear Vrec HIS-N [kN] 7,4 13,1 18,6 28,1 26,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-HY 150 MAX injection mortar may be applied in the temperature ranges given below. An elevated base
material temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +80 C +50 C +80 C
Temperature range III -40 C to +120 C +72 C +120 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

10 / 2012 591
Hilti HIT-HY 150 MAX
with HIS-(R)N

Materials
Mechanical properties of HIS-(R)N
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
HIS-N [N/mm] 490 490 460 460 460
Nominal Screw 8.8 [N/mm] 800 800 800 800 800
tensile
strength fuk HIS-RN [N/mm] 700 700 700 700 700
Screw A4-70 [N/mm] 700 700 700 700 700
HIS-N [N/mm] 410 410 375 375 375
Yield Screw 8.8 [N/mm] 640 640 640 640 640
strength fyk HIS-RN [N/mm] 350 350 350 350 350
Screw A4-70 [N/mm] 450 450 450 450 450
Stressed HIS-(R)N [mm] 51,5 108,0 169,1 256,1 237,6
cross-
section As Screw [mm] 36,6 58 84,3 157 245
Moment of HIS-(R)N [mm] 145 430 840 1595 1543
resistance W Screw [mm] 31,2 62,3 109 277 541

Material quality
Part Material
a)
Internal threaded sleeve C-steel 1.0718,
HIS-N Steel galvanized 5m
a)
Internal threaded sleeve
Stainless steel 1.4401 and 1.4571
HIS-RN
a) related fastening screw: strength class 8.8, A5 > 8% Ductile
steel galvanized 5m
b) related fastening screw: strength class 70, A5 > 8% Ductile
stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362

Anchor dimensions
Anchor size
Internal threaded sleeve M8x90 M10x110 M12x125 M16x170 M20x205
HIS-N / HIS-RN
Embedment depth hef [mm] 80 90 110 125 170

Setting
installation equipment
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

592 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

Setting instruction

Dry and water-saturated concrete, hammer drilling

a)

b)

a) Note: Manual cleaning for HIS-(R)N M8 and HIS-(R)N M10 only!


b) Note: Extension and piston plug needed for overhead installation!

For detailed information on installation see instruction for use given with the package of the product.

10 / 2012 593
Hilti HIT-HY 150 MAX
with HIS-(R)N

Working time, Curing time


Temperature Working time Curing time
of the base material TBM tgel tcure
-10 C TBM < -5 C 180 min 12 h
-5 C TBM < 0 C 40 min 4 h
0 C TBM < 5 C 20 min 2 h
5 C TBM < 20 C 8 min 1 h
20 C TBM < 30 C 5 min 30 min
30 C TBM 40 C 2 min 30 min

Setting details
hS

df
d
d0

Bore hole depth h0 =


Embedment depth hef

594 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

Anchor size M8x90 M10x110 M12x125 M16x170 M20x205


Nominal diameter of
d0 [mm] 14 18 22 28 32
drill bit
Diameter of element d [mm] 12,5 16,5 20,5 25,4 27,6
Effective anchorage
hef [mm] 90 110 125 170 205
and drill hole depth
Minimum base
hmin [mm] 120 150 170 230 270
material thickness
Diameter of clearance
df [mm] 9 12 14 18 22
hole in the fixture
Thread engagement
hs [mm] 8-20 10-25 12-30 16-40 20-50
length; min - max
a)
Torque moment Tmax [Nm] 10 20 40 80 150
Minimum spacing smin [mm] 40 45 55 65 90
Minimum edge
cmin [mm] 40 45 55 65 90
distance
Critical spacing
scr,sp [mm] 2 ccr,sp
for splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


c) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N [mm] 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N [mm] 1,5 hef
c)
failure

For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a) Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing
and/or edge distance.
b) h: base material thickness (h hmin), hef: embedment depth
c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.

10 / 2012 595
Hilti HIT-HY 150 MAX
with HIS-(R)N

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in
ETA-08/0352, issue 2010-04-01.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

TENSION loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
HIS-N [kN] 17,5 30,7 44,7 80,3 74,1
NRd,s
HIS-RN [kN] 13,9 21,9 31,6 58,8 69,2

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
0
N Rd,p Temperature range I [kN] 19,4 27,8 50,0 63,3 76,7
0
N Rd,p Temperature range II [kN] 16,7 27,8 40,0 63,3 63,3
0
N Rd,p Temperature range III [kN] 11,1 16,7 26,7 40,0 40,0

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size M8 M10 M12 M16 M20
0
N Rd,c [kN] 24,0 32,4 47,1 74,6 98,8

596 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,10 a)
fB,p = (fck,cube/25N/mm) 1,00 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = 1

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,5 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N 1
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp 1

f2,N = 0,5(1 + c/ccr,N) 1


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp) 1
a) The edge distance shall not be smaller than the minimum edge distance cmin. These influencing factors must
be considered for every edge distance smaller than the critical edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N) 1
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp) 1
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin. This influencing factor must
be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


fh,N = 1

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.

10 / 2012 597
Hilti HIT-HY 150 MAX
with HIS-(R)N

SHEAR loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
VRd,s
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
0
V Rd,c [kN] 12,4 19,6 28,2 40,2 46,2

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

598 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


Anchor size M8 M10 M12 M16 M20
f hef = 1,38 1,21 1,04 1,22 1,45

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined TENSION and SHEAR loading


For combined tension and shear loading see section Anchor Design.

10 / 2012 599
Hilti HIT-HY 150 MAX
with HIS-(R)N

Precalculated values design resistance values


All data applies to:
- non-cracked concrete C 20/25 fck,cube =25 N/mm
- temperature range I (see service temperature range)
- minimum thickness of base material
- no effects of dense reinforcement

Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

Design resistance: non-cracked- concrete C 20/25


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
Base material thickness h = hmin [mm] 120 150 170 230 270
Tensile NRd: single anchor, no edge effects
HIS-N [kN] 17,5 27,8 44,7 63,3 74,1
HIS-RN [kN] 13,9 21,9 31,6 58,8 69,2
Shear VRd: single anchor, no edge effects, without lever arm
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

Design resistance: non-cracked- concrete C 20/25


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
Base material thickness h = hmin [mm] 120 150 170 230 270
Edge distance c = cmin [mm] 40 45 55 65 90
Tensile NRd: single anchor, min. edge distance (c = cmin)
HIS-N [kN] 9,9 13,8 21,6 31,2 41,7
HIS-RN [kN] 9,9 13,8 21,6 31,2 41,7
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
HIS-N [kN] 4,2 5,5 7,6 10,8 17,2
HIS-RN [kN] 4,2 5,5 7,6 10,8 17,2

Design resistance: non-cracked- concrete C 20/25


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
Base material thickness h = hmin [mm] 120 150 170 230 270
Spacing s = smin [mm] 40 45 55 65 90
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIS-N [kN] 11,9 16,6 25,9 37,9 48,4
HIS-RN [kN] 11,9 16,6 25,9 37,9 48,4
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

600 10 / 2012
Hilti HIT-HY 150 MAX
with HIS-(R)N

10 / 2012 601
Hilti HIT-HY 150 MAX
with rebar

Hilti HIT-HY 150 MAX with rebar


Injection mortar system Benefits
- suitable for non-cracked and
Hilti HIT- cracked concrete
HY 150 MAX C 20/25 to C 50/60
330 ml foil pack - suitable for dry and water
(also available saturated concrete
as 500 ml - high loading capacity
and 1400 ml - rapid curing
foil pack) - small edge distance and anchor
spacing possible
- large diameter applications
Static mixer - in service temperature range up
to 120C short term/72C long
term
- manual cleaning for anchor size
8 to 14 and embedment depth
hef 10d for non-cracked
rebar BSt 500 S concrete
- embedment depth range:
from 60 ... 160 mm for 8
to 100 ... 500 mm for 25

PROFIS
Small edge Variable European
Tensile CE Anchor
Concrete distance embedment Technical
zone conformity design
and spacing depth Approval
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
a)
European technical approval DIBt, Berlin ETA-08/0352 / 2010-04-01
a) All data given in this section according ETA-08/0352 issue 2010-04-01.

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- Anchor material: rebar BSt 500 S
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range -10C to +40C

602 10 / 2012
Hilti HIT-HY 150 MAX
with rebar

Embedment depth a) and base material thickness for the basic loading data. Mean
ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size 8 10 12 14 16 20 25
b)
Embedment depth hef = hef,typ [mm] 80 90 110 125 145 170 210
Base material thickness h [mm] 110 120 140 165 185 220 274
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.
b) hef,typ: Typical embedment depth

Mean ultimate resistance: non-cracked concrete C 20/25 , anchor BSt 500 S


Anchor size 8 10 12 14 16 20 25
Non-cracked concrete
Tensile NRu,m BST 500 S [kN] 25,5 35,8 52,5 69,6 92,3 135,3 204,9
Shear VRu,m BST 500 S [kN] 14,7 23,1 32,6 44,1 57,8 90,3 141,8
Cracked concrete
Tensile NRu,m BST 500 S [kN] - 20,7 30,4 44,0 58,3 85,5 131,9
Shear VRu,m BST 500 S [kN] - 23,1 32,6 44,1 57,8 90,3 141,8

Characteristic resistance: non-cracked concrete C 20/25 , anchor BSt 500 S


Anchor size 8 10 12 14 16 20 25
Non-cracked concrete
Tensile NRk BST 500 S [kN] 19,1 26,9 39,4 52,2 69,2 101,5 153,7
Shear VRk BST 500 S [kN] 14,0 22,0 31,0 42,0 55,0 86,0 135,0
Cracked concrete
Tensile NRk BST 500 S [kN] - 15,6 22,8 33,0 43,7 64,1 99,0
Shear VRk BST 500 S [kN] - 22,0 31,0 42,0 55,0 86,0 135,0

Design resistance: non-cracked concrete C 20/25 , anchor BSt 500 S


Anchor size 8 10 12 14 16 20 25
Non-cracked concrete
Tensile NRd BST 500 S [kN] 10,6 14,9 21,9 29,0 46,2 67,6 85,4
Shear VRd BST 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0
Cracked concrete
Tensile NRd BST 500 S [kN] - 10,4 15,2 22,0 29,2 42,7 55,0
Shear VRd BST 500 S [kN] - 14,7 20,7 28,0 36,7 57,3 90,0

Recommended loads a): non-cracked concrete C 20/25 , anchor BSt 500 S


Anchor size 8 10 12 14 16 20 25
Non-cracked concrete
Tensile Nrec BST 500 S [kN] 7,6 10,7 15,6 20,7 33,0 48,3 61,0
Shear Vrec BST 500 S [kN] 6,7 10,5 14,8 20,0 26,2 41,0 64,3
Cracked concrete
Tensile Nrec BST 500 S [kN] - 7,4 10,9 15,7 20,8 30,5 39,3
Shear Vrec BST 500 S [kN] - 10,5 14,8 20,0 26,2 41,0 64,3
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

10 / 2012 603
Hilti HIT-HY 150 MAX
with rebar

Service temperature range


Hilti HIT-HY 150 MAX injection mortar may be applied in the temperature ranges given below. An elevated base
material temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +80 C +50 C +80 C
Temperature range III -40 C to +120 C +72 C +120 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of rebar BSt 500S
Anchor size 8 10 12 14 16 20 25
Nominal
tensile BSt 500 S [N/mm] 550
strength fuk
Yield
BSt 500 S [N/mm] 500
strength fyk
Stressed
cross- BSt 500 S [mm] 50,3 78,5 113,1 153,9 201,1 314,2 490,9
section As
Moment of
resistance BSt 500 S [mm] 50,3 98,2 169,6 269,4 402,1 785,4 1534
W

Material quality
Part Material
rebar Mechanical properties according to DIN 488-1:1984
BSt 500 S Geometry according to DIN 488-21:1986

Anchor dimensions
Anchor size 8 10 12 14 16 20 25
rebar
rebar are available in variable length
BSt 500 S

Setting
installation equipment
Anchor size 8 10 12 14 16 20 25
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

604 10 / 2012
Hilti HIT-HY 150 MAX
with rebar

Setting instruction

Dry and water-saturated concrete, hammer drilling

a)

b)

a) Note: Manual cleaning for non-cracked concrete, element sizes d 14mm and embedment depth
hef 10 d only!
b) Note: Extension and piston plug needed for overhead installation and/or embedment depth > 250mm!

For detailed information on installation see instruction for use given with the package of the product.

10 / 2012 605
Hilti HIT-HY 150 MAX
with rebar

Working time, Curing time


Temperature Working time Curing time
of the base material TBM tgel tcure
-10 C TBM < -5 C 180 min 12 h
-5 C TBM < 0 C 40 min 4 h
0 C TBM < 5 C 20 min 2 h
5 C TBM < 20 C 8 min 1 h
20 C TBM < 30 C 5 min 30 min
30 C TBM 40 C 2 min 30 min

Setting details
d0

Bore hole depth h0 = embedment depth hef

Thickness of concrete member h

606 10 / 2012
Hilti HIT-HY 150 MAX
with rebar

Anchor size 8 10 12 14 16 20 25
Nominal diameter of d) d) d)
d0 [mm] 10-12 12-14 14-16 18 20 25 32
drill bit
Effective embedment and hef,min [mm] 60 60 70 75 80 90 100
drill hole depth range
a)

for rebar BSt 500 S hef,max [mm] 160 200 240 280 320 400 500
Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness 100 mm
Minimum spacing smin [mm] 40 50 60 70 80 100 150
Minimum edge
cmin [mm] 40 50 60 80 100 120 150
distance
Critical spacing
scr,sp [mm] 2 ccr,sp
for splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


c) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N [mm] 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N [mm] 1,5 hef
c)
failure

For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a) Embedment depth range: hef,min hef hef,max
b) h: base material thickness (h hmin), hef: embedment depth
c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
d) both given values for drill bit diameter can be used

10 / 2012 607
Hilti HIT-HY 150 MAX
with rebar

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in
ETA-08/0352, issue 2010-04-01.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

TENSION loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Anchor size 8 10 12 14 16 20 25
NRd,s BSt 500 S [kN] 20,0 30,7 44,3 60,7 79,3 123,6 192,9

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Anchor size 8 10 12 14 16 20 25
Embedment depth hef =
[mm] 80 90 110 125 145 170 210
Typical embedment depth hef,typ
Non-cracked concrete
0
N Rd,p Temperature range I [kN] 10,6 14,9 21,9 29,0 46,2 67,6 87,0
0
N Rd,p Temperature range II [kN] 8,9 12,6 18,4 24,4 38,9 57,0 73,3
0
N Rd,p Temperature range III [kN] 5,6 7,9 11,5 15,3 24,3 35,6 45,8
Cracked concrete
0
N Rd,p Temperature range I [kN] - 10,4 15,2 22,0 29,2 42,7 55,0
0
N Rd,p Temperature range II [kN] - 8,5 13,8 18,3 26,7 42,7 55,0
0
N Rd,p Temperature range III [kN] - 5,7 8,3 12,8 17,0 24,9 36,7

608 10 / 2012
Hilti HIT-HY 150 MAX
with rebar

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size 8 10 12 14 16 20 25
0
N Rd,c Non-cracked concrete [kN] 20,1 24,0 32,4 39,2 58,8 74,6 85,4
0
N Rd,c Cracked concrete [kN] - 28,7 38,8 47,1 58,8 74,6 85,4
a) Splitting resistance must only be considered for non-cracked concrete

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,10 a)
fB,p = (fck,cube/25N/mm) 1,00 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,5 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N 1
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp 1

f2,N = 0,5(1 + c/ccr,N) 1


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp) 1
a) The edge distance shall not be smaller than the minimum edge distance cmin. These influencing factors must
be considered for every edge distance smaller than the critical edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N) 1
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp) 1
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin. This influencing factor must
be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hef/hef,typ)

10 / 2012 609
Hilti HIT-HY 150 MAX
with rebar

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.

SHEAR loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Anchor size 8 10 12 14 16 20 25
VRd,s Rebar BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size 8 10 12 14 16 20 25
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 15,0 18,7 27,0 39,2
Cracked concrete
0
V Rd,c [kN] - 6,1 8,2 10,6 13,2 19,2 27,7

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

610 10 / 2012
Hilti HIT-HY 150 MAX
with rebar

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


hef/d 4 4,5 5 6 7 8 9 10 11
0,05 (hef / d)
1,68
f hef = 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81
hef/d 12 13 14 15 16 17 18 19 20
0,05 (hef / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

10 / 2012 611
Hilti HIT-HY 150 MAX
with rebar

Combined TENSION and SHEAR loading


For combined tension and shear loading see section Anchor Design.

Precalculated values design resistance values


All data applies to:
- non-cracked concrete C 20/25 fck,cube =25 N/mm
- temperature range I (see service temperature range)
- minimum thickness of base material
- no effects of dense reinforcement

Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

612 10 / 2012
Hilti HIT-HY 150 MAX
with rebar

Design resistance: concrete C 20/25 - minimum embedment depth


Anchor size 8 10 12 14 16 20 25
Embedment depth hef = hef,min [mm] 60 60 70 80 90 100 110
Base material thickness h = hmin [mm] 100 100 102 116 130 150 174
Tensile NRd: single anchor, no edge effects
Non-cracked concrete
BSt 500 S [kN] 8,0 9,9 13,9 18,6 28,7 33,7 32,4
Cracked concrete
BSt 500 S [kN] - 6,9 9,7 14,1 18,1 24,0 23,1
Shear VRd: single anchor, no edge effects, without lever arm
Non-cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 64,7
Cracked concrete
BSt 500 S [kN] - 13,8 19,4 28,0 36,2 48,0 46,1

Design resistance: concrete C 20/25 - minimum embedment depth


Anchor size 8 10 12 14 16 20 25
Embedment depth hef = hef,min [mm] 60 60 70 80 90 100 110
Base material thickness h = hmin [mm] 100 100 102 116 130 150 174
Edge distance c = cmin [mm] 40 50 60 80 100 120 135
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non-cracked concrete
BSt 500 S [kN] 4,8 6,7 9,5 12,8 19,4 24,4 25,0
Cracked concrete
BSt 500 S [kN] - 4,7 6,6 10,6 14,5 20,3 19,8
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
Non-cracked concrete
BSt 500 S [kN] 3,5 4,9 6,6 10,0 13,2 17,4 21,8
Cracked concrete
BSt 500 S [kN] - 3,5 4,7 7,1 9,4 12,3 15,4

Design resistance: concrete C 20/25 - minimum embedment depth (load values are valid for single anchor)
Anchor size 8 10 12 14 16 20 25
Embedment depth hef = hef,min [mm] 60 60 70 80 90 100 110
Base material thickness h = hmin [mm] 100 100 100 116 138 156 170
Spacing s = smin [mm] 40 50 60 80 100 120 135
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non-cracked concrete
BSt 500 S [kN] 5,4 6,8 9,3 12,2 17,6 21,3 22,5
Cracked concrete
BSt 500 S [kN] - 4,9 6,7 9,5 12,1 15,2 16,0
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
Non-cracked concrete
BSt 500 S [kN] 9,3 12,7 17,9 24,0 36,7 44,9 47,1
Cracked concrete
BSt 500 S [kN] - 8,8 12,4 18,2 23,5 32,0 33,6

10 / 2012 613
Hilti HIT-HY 150 MAX
with rebar

Design resistance: concrete C 20/25 - typical embedment depth


Anchor size 8 10 12 14 16 20 25
Embedment depth hef = hef,typ [mm] 80 90 110 125 145 170 210
Base material thickness h = hmin [mm] 110 120 142 161 185 220 274
Tensile NRd: single anchor, no edge effects
Non-cracked concrete
BSt 500 S [kN] 10,6 14,9 21,9 29,0 46,2 67,6 85,4
Cracked concrete
BSt 500 S [kN] - 10,4 15,2 22,0 29,2 42,7 55,0
Shear VRd: single anchor, no edge effects, without lever arm
Non-cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0
Cracked concrete
BSt 500 S [kN] - 14,7 20,7 28,0 36,7 57,3 90,0

Design resistance: concrete C 20/25 - typical embedment depth


Anchor size 8 10 12 14 16 20 25
Embedment depth hef = hef,typ [mm] 80 90 110 125 145 170 210
Base material thickness h = hmin [mm] 110 120 142 161 185 220 274
Edge distance c = cmin [mm] 40 50 60 80 100 120 135
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non-cracked concrete
BSt 500 S [kN] 6,4 9,0 13,2 18,6 30,4 38,9 43,1
Cracked concrete
BSt 500 S [kN] - 6,2 9,1 14,1 19,6 28,2 34,3
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
Non-cracked concrete
BSt 500 S [kN] 3,7 5,3 7,3 11,2 15,8 21,5 27,5
Cracked concrete
BSt 500 S [kN] - 3,8 5,2 7,9 11,2 15,2 19,5

Design resistance concrete C 20/25 - typical embedment depth (load values are valid for single anchor)
Anchor size 8 10 12 14 16 20 25
Embedment depth hef = hef,typ [mm] 80 90 110 125 145 170 210
Base material thickness h = hmin [mm] 110 120 142 161 185 220 274
Spacing s = smin [mm] 40 50 60 80 100 120 135
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non-cracked concrete
BSt 500 S [kN] 7,4 10,1 14,7 19,1 30,1 42,2 49,5
Cracked concrete
BSt 500 S [kN] - 7,2 10,5 14,8 19,5 27,7 35,3
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
Non-cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0
Cracked concrete
BSt 500 S [kN] - 12,3 18,0 26,1 34,5 51,1 68,1

614 10 / 2012
Hilti HIT-HY 150 MAX
with rebar

a)
Design resistance: concrete C 20/25 - embedment depth = 12 d
Anchor size 8 10 12 14 16 20 25
Embedment depth hef = 12 d a) [mm] 96 120 144 168 192 240 300
Base material thickness h = hmin [mm] 126 150 176 204 232 290 364
Tensile NRd: single anchor, no edge effects
Non-cracked concrete
BSt 500 S [kN] 12,7 19,9 28,7 39,0 61,1 95,5 124,4
Cracked concrete
BSt 500 S [kN] - 13,8 19,9 29,6 38,6 60,3 78,5
Shear VRd: single anchor, no edge effects, without lever arm
Non-cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0
Cracked concrete
BSt 500 S [kN] - 14,7 20,7 28,0 36,7 57,3 90,0
a)
Design resistance: concrete C 20/25 - embedment depth = 12 d
Anchor size 8 10 12 14 16 20 25
Embedment depth hef = 12 d a) [mm] 96 120 144 168 192 240 300
Base material thickness h = hmin [mm] 126 150 176 204 232 290 364
Edge distance c = cmin [mm] 40 50 60 80 100 120 135
Tensile NRd: single anchor, min. edge distance (c = cmin)
Non-cracked concrete
BSt 500 S [kN] 7,7 12,0 17,2 25,1 41,2 58,6 66,4
Cracked concrete
BSt 500 S [kN] - 8,3 12,0 19,0 26,0 39,8 49,0
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
Non-cracked concrete
BSt 500 S [kN] 3,9 5,7 7,8 12,0 16,9 23,6 30,5
Cracked concrete
BSt 500 S [kN] - 4,0 5,5 8,5 12,0 16,7 21,6
a)
Design resistance: concrete C 20/25 - embedment depth = 12 d (load values are valid for single anchor)
Anchor size 8 10 12 14 16 20 25
Embedment depth hef = 12 d a) [mm] 96 120 144 168 192 240 300
Base material thickness h = hmin [mm] 126 150 176 204 232 290 364
Spacing s = smin [mm] 40 50 60 80 100 120 135
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
Non-cracked concrete
BSt 500 S [kN] 8,9 13,8 19,6 26,4 40,9 62,6 81,0
Cracked concrete
BSt 500 S [kN] - 9,8 13,9 20,3 26,3 40,5 53,2
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
Non-cracked concrete
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0
Cracked concrete
BSt 500 S [kN] - 14,7 20,7 28,0 36,7 57,3 90,0
a) d = element diameter

10 / 2012 615
Hilti HIT-CT 1
with HIT-V

Hilti HIT-CT 1 with HIT-V


Injection mortar system Benefits

- Hilti Clean technology (clean-


Tec)
- Environmentaly and user friendly:
Hilti
clean of critical hazardous
HIT-CT 1
substances
330 ml foil pack
(also available - Approved automatic cleaning with
as 500 ml the use of the hollow drill-bit
foil pack) - Suitable for non-cracked concrete
C 20/25 to C 50/60
- High loading capacity
- Rapid curing
- Large diameter applications
Static mixer
- In service temperature range up
to 80C short term/50C long
term
- Manual cleaning
HIT-V(-F) rods for anchor size M8 to M16 and
HIT-V-R rods embedment depth 8d hef 10d
HIT-V-HCR rods - Compressd air cleaning
for anchor size M8 to M25 and
embedment depth 8d hef 12d

Approved
Small edge Variable High European Clean-Tec
Corrosion CE automatic
Concrete distance embedment corrosion Technical Label free
resistance conformity cleaning
and spacing depth resistance Approval motrar
while drilling

PROFIS
Anchor
design
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
a)
European technical approval CSTB, Paris ETA-11/0354 / 2011-09-30
a) All data given in this section according ETA-11/0354 issue 2011-09-30.

616 10 / 2012
Hilti HIT-CT 1
with HIT-V

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range -5C to +40C

Embedment depth a) and base material thickness for the basic loading data. Mean
ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size M8 M10 M12 M16 M20 M24
Typical embedment depth hef [mm] 80 90 110 130 170 210
Base material thickness h [mm] 110 120 140 170 220 270
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.

Mean ultimate resistance: non-cracked concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24
Tensile NRu,m HIT-V 5.8 [kN] 18,9 30,5 44,1 87,1 135,3 190,0
Shear VRu,m HIT-V 5.8 [kN] 9,5 15,8 22,1 41,0 64,1 92,4

Characteristic resistance: non-cracked concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24
Tensile NRk HIT-V 5.8 [kN] 18,0 29,0 42,0 65,3 101,5 142,5
Shear VRk HIT-V 5.8 [kN] 9,0 15,0 21,0 39,0 61,0 88,0

Design resistance: non-cracked concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24
Tensile NRd HIT-V 5.8 [kN] 12,0 17,3 25,3 36,3 56,4 79,2
Shear VRd HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4

Recommended loads a): non-cracked concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24
Tensile Nrec HIT-V 5.8 [kN] 8,6 12,3 18,1 25,9 40,3 56,5
Shear Vrec HIT-V 5.8 [kN] 5,1 8,6 12,0 22,3 34,9 50,3
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.

10 / 2012 617
Hilti HIT-CT 1
with HIT-V

Service temperature range


Hilti HIT-CT 1injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +80 C +50 C +80 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of HIT-V
Anchor size M8 M10 M12 M16 M20 M24
HIT-V(-F) 5.8 [N/mm] 500 500 500 500 500 500
Nominal HIT-V(-F) 8.8 [N/mm] 800 800 800 800 800 800
tensile
strength fuk HIT-V -R [N/mm] 700 700 700 700 700 700
HIT-V -HCR [N/mm] 800 800 800 800 800 700
HIT-V(-F) 5.8 [N/mm] 400 400 400 400 400 400
Yield HIT-V(-F) 8.8 [N/mm] 640 640 640 640 640 640
strength fyk HIT-V -R [N/mm] 450 450 450 450 450 450
HIT-V -HCR [N/mm] 600 600 600 600 600 400
Stressed
cross- HIT-V [mm] 36,6 58,0 84,3 157 245 353
section As
Moment of
resistance HIT-V [mm] 31,2 62,3 109 277 541 935
W

618 10 / 2012
Hilti HIT-CT 1
with HIT-V

Material quality
Part Material
Strength class 5.8, A5 > 8% ductile
Threaded rod
steel galvanized 5 m
HIT-V(-F) 5.8
(-F) hot dipped galvanized 45 m
Strength class 8.8, A5 > 8% ductile
Threaded rod
steel galvanized 5 m
HIT-V(-F) 8.8
(-F) hot dipped galvanized 45 m (M8-M16 only)
Stainless steel grade A4, A5 > 8% ductile
Threaded rod
strength class 70 for M24
HIT-V-R
1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, 1.4529; 1.4565
Threaded rod
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
HIT-V-HCR
M24: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, hot dipped galvanized
Washer
Stainless steel, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
ISO 7089
High corrosion resistant steel, 1.4529; 1.4565
Strength class 8
steel galvanized 5 m
hot dipped galvanized 45 m
Nut
Strength class 70, stainless steel grade A4,
EN ISO 4032
1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, EN ISO 3506-2, high corrosion resistant steel,
1.4529; 1.4565

Anchor dimensions
Anchor size M8 M10 M12 M16 M20 M24
Anchor rod
HIT-V, HIT-V-F Anchor rods HIT-V (-F/ -R / -HCR) are available in variable length
HIT-V-R, HIT-V-HCR

10 / 2012 619
Hilti HIT-CT 1
with HIT-V

Setting instruction

Dry and water-saturated concrete, hammer drilling

a)

b)

a) Note: Manual cleaning for element sizes d 16mm and embedment depth hef 10 d only!
b) Note: Extension and piston plug needed for overhead installation and/or embedment depth > 250mm!

For detailed information on installation see instruction for use given with the package of the product.

620 10 / 2012
Hilti HIT-CT 1
with HIT-V

Working time, Curing time


Temperature Working time Curing time
a)
of the base material TBM tgel tcure
-5 C TBM < 0 C 60 min 6 h
0 C TBM < 5 C 40 min 3 h
5 C TBM < 10 C 25 min 2 h
10 C TBM < 20 C 10 min 90 min
20 C TBM < 30 C 4 min 75 min
30 C TBM 40 C 2 min 60 min
a) The curing time data are valid for dry anchorage base only. For water saturated anchorage bases the curing
times must be doubled.

Setting
installation equipment
Anchor size M8 M10 M12 M16 M20 M24
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

Setting details
Marking of the
embedment depth
d0

df

Fixture
Bore hole depth h0 = anchorage depth hef Thickness tfix

Thickness of concrete member h

10 / 2012 621
Hilti HIT-CT 1
with HIT-V

Setting details
Anchor size M8 M10 M12 M16 M20 M24
Nominal diameter of
d0 [mm] 10 12 14 18 22 28
drill bit
Effective embedment and hef,min [mm] 64 80 96 128 160 192
drill hole depth range
a)

for HIT-V hef,max [mm] 96 120 144 192 240 288


Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness 100 mm
Diameter of clearance
df [mm] 9 12 14 18 22 26
hole in the fixture
b)
Torque moment Tmax [Nm] 10 20 40 80 150 200
Minimum spacing smin [mm] 40 50 60 80 100 120
Minimum edge
cmin [mm] 40 50 60 80 100 120
distance
Critical spacing
scr,sp [mm] 2 ccr,sp
for splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


c) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N [mm] 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N [mm] 1,5 hef
d)
failure

For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a) Embedment depth range: hef,min hef hef,max
b) Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing
and/or edge distance.
c) h: base material thickness (h hmin), hef: embedment depth
d) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.

622 10 / 2012
Hilti HIT-CT 1
with HIT-V

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in
ETA-08/0341, issue 2008-12-02.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Anchor size M8 M10 M12 M16 M20 M24
HIT-V(-F) 5.8 [kN] 12,0 19,3 28,0 52,7 82,0 118,0
HIT-V(-F) 8.8 [kN] 19,3 30,7 44,7 84,0 130,7 188,0
NRd,s
HIT-V-R [kN] 13,9 21,9 31,6 58,8 92,0 132,1
HIT-V-HCR [kN] 19,3 30,7 44,7 84,0 130,7 117,6

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Anchor size M8 M10 M12 M16 M20 M24
Typical embedment depth
80 90 110 130 170 210
hef = hef,typ [mm]
0
N Rd,p Temperature range I [kN] 13,4 17,3 25,3 36,3 56,4 79,2
0
N Rd,p Temperature range II [kN] 12,3 17,3 23,0 34,5 53,4 74,8

10 / 2012 623
Hilti HIT-CT 1
with HIT-V

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size M8 M10 M12 M16 M20 M24
0
N Rd,c [kN] 20,1 24,0 32,4 41,6 62,2 85,4

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,15 a)
fB,p = (fck,cube/25N/mm) 1,00 1,03 1,06 1,09 1,11 1,13 1,14
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,5 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N 1
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp 1

f2,N = 0,5(1 + c/ccr,N) 1


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp) 1
a) The edge distance shall not be smaller than the minimum edge distance cmin. These influencing factors must
be considered for every edge distance smaller than the critical edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N) 1
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp) 1
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin. This influencing factor must
be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hef/hef,typ)

624 10 / 2012
Hilti HIT-CT 1
with HIT-V

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Anchor size M8 M10 M12 M16 M20 M24
HIT-V(-F) 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4
HIT-V(-F) 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8
VRd,s
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20 M24
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 18,7 27,0 36,6

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

10 / 2012 625
Hilti HIT-CT 1
with HIT-V

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

f 1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


hef/d 4 4,5 5 6 7 8 9 10 11
0,05 (hef / d)
1,68
f hef = 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81
hef/d 12 13 14 15 16 17 18 19 20
0,05 (hef / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

626 10 / 2012
Hilti HIT-CT 1
with HIT-V

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values design resistance values


All data applies to:
- non-cracked concrete C 20/25 fck,cube =25 N/mm
- temperature range I (see Service temperature range)
- minimum thickness of base material
- no effects of dense reinforcement

Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

10 / 2012 627
Hilti HIT-CT 1
with HIT-V

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - minimum embedment depth


Anchor size M8 M10 M12 M16 M20 M24
Embedment depth hef = hef,min [mm] 64 80 96 128 160 192
Base material thickness h = hmin [mm] 100 110 126 164 204 248
Tensile NRd: single anchor, no edge effects
HIT-V(-F) 5.8
HIT-V(-F) 8.8
[kN] 10,7 15,4 22,1 35,7 53,1 72,4
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, no edge effects, without lever arm
HIT-V(-F) 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4
HIT-V(-F) 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - minimum embedment depth


Anchor size M8 M10 M12 M16 M20 M24
Embedment depth hef = hef,min [mm] 64 80 96 128 160 192
Base material thickness h = hmin [mm] 100 110 126 164 204 248
Edge distance c = cmin [mm] 40 50 60 80 100 120
Tensile NRd: single anchor, min. edge distance (c = cmin)
HIT-V(-F) 5.8
HIT-V(-F) 8.8
[kN] 6,3 9,0 12,9 21,3 31,9 43,6
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
HIT-V(-F) 5.8
HIT-V(-F) 8.8
[kN] 3,6 5,2 7,1 11,6 16,9 23,0
HIT-V-R
HIT-V-HCR

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - minimum embedment depth


(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20 M24
Embedment depth hef = hef,min [mm] 64 80 96 128 160 192
Base material thickness h = hmin [mm] 100 110 126 164 204 248
Spacing s = smin [mm] 40 50 60 80 100 120
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V(-F) 5.8
HIT-V(-F) 8.8
[kN] 7,0 10,0 14,0 22,6 33,1 44,8
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
HIT-V(-F) 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4
HIT-V(-F) 8.8 [kN] 12,0 18,4 26,7 43,2 64,1 87,5
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5
HIT-V-HCR [kN] 12,0 18,4 26,7 43,2 64,1 70,9

628 10 / 2012
Hilti HIT-CT 1
with HIT-V

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - typical embedment depth


Anchor size M8 M10 M12 M16 M20 M24
Embedment depth hef = hef,typ [mm] 80 90 110 130 170 210
Base material thickness h = hmin [mm] 110 120 140 166 214 266
Tensile NRd: single anchor, no edge effects
HIT-V(-F) 5.8 [kN] 12,0 17,3 25,3 36,3 56,4 79,2
HIT-V(-F) 8.8
HIT-V-R [kN] 13,4 17,3 25,3 36,3 56,4 79,2
HIT-V-HCR
Shear VRd: single anchor, no edge effects, without lever arm
HIT-V(-F) 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4
HIT-V(-F) 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - typical embedment depth


Anchor size M8 M10 M12 M16 M20 M24
Embedment depth hef = hef,typ [mm] 80 90 110 130 170 210
Base material thickness h = hmin [mm] 110 120 140 166 214 266
Edge distance c = cmin [mm] 40 50 60 80 100 120
Tensile NRd: single anchor, min. edge distance (c = cmin)
HIT-V(-F) 5.8
HIT-V(-F) 8.8
[kN] 7,7 10,1 14,7 21,6 33,9 48,0
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
HIT-V(-F) 5.8
HIT-V(-F) 8.8
[kN] 3,7 5,3 7,3 11,6 17,2 23,6
HIT-V-R
HIT-V-HCR

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - typical embedment depth


(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20 M24
Embedment depth hef = hef,typ [mm] 80 90 110 130 170 210
Base material thickness h = hmin [mm] 110 120 140 166 214 266
Spacing s [mm] 40 50 60 80 100 120
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V(-F) 5.8
HIT-V(-F) 8.8
[kN] 8,9 11,3 16,3 23,0 35,4 49,7
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
HIT-V(-F) 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4
HIT-V(-F) 8.8 [kN] 12,0 18,4 27,2 43,7 67,4 94,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5
HIT-V-HCR [kN] 12,0 18,4 27,2 43,7 67,4 70,9

10 / 2012 629
Hilti HIT-CT 1
with HIT-V

a)
Design resistance: concrete C 20/25 fck,cube = 25 N/mm - embedment depth = 12 d
Anchor size M8 M10 M12 M16 M20 M24
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288
Base material thickness h = hmin [mm] 126 150 174 228 288 344
Tensile NRd: single anchor, no edge effects
HIT-V(-F) 5.8 [kN] 12,0 19,3 28,0 52,7 79,6 108,6
HIT-V(-F) 8.8 [kN] 16,1 23,0 33,2 53,6 79,6 108,6
HIT-V-R [kN] 13,9 21,9 31,6 53,6 79,6 108,6
HIT-V-HCR [kN] 16,1 23,0 33,2 53,6 79,6 108,6
Shear VRd: single anchor, no edge effects, without lever arm
HIT-V(-F) 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4
HIT-V(-F) 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9
a) d = element diameter
a)
Design resistance: concrete C 20/25 fck,cube = 25 N/mm - embedment depth = 12 d
Anchor size M8 M10 M12 M16 M20 M24
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288
Base material thickness h = hmin [mm] 126 150 174 228 284 344
Edge distance c = cmin [mm] 40 50 60 80 100 120
Tensile NRd: single anchor, min. edge distance (c = cmin)
HIT-V(-F) 5.8
HIT-V(-F) 8.8
[kN] 9,2 13,4 19,3 31,9 47,9 66,2
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
HIT-V(-F) 5.8
HIT-V(-F) 8.8
[kN] 3,9 5,7 7,8 12,9 18,9 25,9
HIT-V-R
HIT-V-HCR
a) d = element diameter
a)
Design resistance: concrete C 20/25 fck,cube = 25 N/mm - embedment depth = 12 d
(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20 M24
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288
Base material thickness h = hmin [mm] 126 150 174 228 284 344
Spacing s=smin [mm] 40 50 60 80 100 120
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V(-F) 5.8
HIT-V(-F) 8.8
[kN] 10,8 15,5 22,0 35,4 52,1 70,9
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V(-F) 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4
HIT-V(-F) 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9
a) d = element diameter

630 10 / 2012
Hilti HIT-CT 1
with HIT-V

10 / 2012 631
Hilti HIT-HY 150
with HIT-V / HAS

Hilti HIT-HY 150 with HIT-V / HAS


Injection mortar system Benefits

Hilti - suitable for non-cracked concrete


HIT-HY 150 C 20/25 to C 50/60
330 ml foil pack - suitable for dry and water
(also available saturated concrete
as 500 ml - high loading capacity
and 1400 ml
foil pack) - rapid curing
- small edge distance and anchor
spacing possible
Static mixer - large diameter applications
- high corrosion resistant
HAS rods - in service temperature range up
HAS-R rods to 120C short term/72C long
HAS-HCR rods term
- manual cleaning for anchor size
HAS-E rods M8 to M16 and embedment depth
HAS-E-R rods hef 10d
- embedment depth range
HIT-V rods M8: 60 to 160 mm
HIT-V-R rods M30: 120 to 600 mm
HIT-V-HCR rods

PROFIS
Small edge Variable High
Fire Corrosion Anchor
Concrete distance embedment corrosion
resistance resistance design
and spacing depth resistance
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
Fire test report MFPA Braunschweig UB 3027 / 0274-6 / 1994-06-30
Assessment report (fire) warringtonfire WF 166402 / 2007-10-26
a) All data given in this section according ETA-05/0051 issue 2011-03-17.

632 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range -5C to +40C

Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended
loads.
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth hef [mm] 80 90 110 125 170 210 240 270
Base material thickness h [mm] 110 120 140 165 220 270 300 340
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.

Mean ultimate resistance: non-cracked concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Tensile NRu,m HIT-V 5.8 [kN] 18,9 30,5 44,1 75,4 121,1 168,9 203,6 237,5
Shear VRu,m HIT-V 5.8 [kN] 9,5 15,8 22,1 41,0 64,1 92,4 120,8 147,0

Characteristic resistance: non-cracked concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Tensile NRk HIT-V 5.8 [kN] 18,0 29,0 42,0 56,5 90,8 126,7 152,7 178,1
Shear VRk HIT-V 5.8 [kN] 9,0 15,0 21,0 39,0 61,0 88,0 115,0 140,0

Design resistance: non-cracked concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Tensile NRd HIT-V 5.8 [kN] 12,0 17,3 25,3 26,9 43,2 60,3 72,7 84,8
Shear VRd HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0

Recommended loads a): non-cracked concrete C 20/25 , anchor HIT-V 5.8


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Tensile Nrec HIT-V 5.8 [kN] 8,6 12,3 18,1 19,2 30,9 43,1 51,9 60,6
Shear Vrec HIT-V 5.8 [kN] 5,1 8,6 12,0 22,3 34,9 50,3 65,7 80,0
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

10 / 2012 633
Hilti HIT-HY 150
with HIT-V / HAS

Service temperature range


Hilti HIT-HY 150 injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +80 C +50 C +80 C
Temperature range III -40 C to +120 C +72 C +120 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

Materials
Mechanical properties of HIT-V / HAS
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HIT-V/HAS 5.8 [N/mm] 500 500 500 500 500 500 500 500
Nominal HIT-V/HAS 8.8 [N/mm] 800 800 800 800 800 800 800 800
tensile
strength fuk HIT-V/HAS -R [N/mm] 700 700 700 700 700 700 500 500
HIT-V/HAS -HCR [N/mm] 800 800 800 800 800 700 700 700
HIT-V/HAS 5.8 [N/mm] 400 400 400 400 400 400 400 400
Yield HIT-V/HAS 8.8 [N/mm] 640 640 640 640 640 640 640 640
strength fyk HIT-V/HAS -R [N/mm] 450 450 450 450 450 450 210 210
HIT-V/HAS -HCR [N/mm] 600 600 600 600 600 400 400 400
Stressed HAS [mm] 32,8 52,3 76,2 144 225 324 427 519
cross-
section As HIT-V [mm] 36,6 58,0 84,3 157 245 353 459 561
Moment of HAS [mm] 27,0 54,1 93,8 244 474 809 1274 1706
resistance
W HIT-V [mm] 31,2 62,3 109 277 541 935 1387 1874

634 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS

Material quality
Part Material
Threaded rod Strength class 5.8, A5 > 8% ductile
HIT-V(F), steel galvanized 5 m,
HAS 5.8: M8 M24 (F) hot dipped galvanized 45 m,
Threaded rod Strength class 8.8, A5 > 8% ductile
HIT-V(F), steel galvanized 5 m,
HAS 8.8: M27 M30 (F) hot dipped galvanized 45 m,
Stainless steel grade A4, A5 > 8% ductile
Threaded rod
strength class 70 for M24 and class 50 for M27 to M30, 1.4401; 1.4404;
HIT-V-R, HAS-R
1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, 1.4529; 1.4565
Threaded rod
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
HIT-V-HCR, HAS-HCR
M24 to M30: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, hot dipped galvanized,
Washer
Stainless steel, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
ISO 7089
High corrosion resistant steel, 1.4529; 1.4565
Strength class 8,
steel galvanized 5 m,
hot dipped galvanized 45 m
Nut
Strength class 70, stainless steel grade A4,
EN ISO 4032
1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, high corrosion resistant steel,
1.4529; 1.4565

Anchor dimensions
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
M12x110

M16x125

M20x170

M24x210

M27x240

M30x270
M10x90

Anchor rod
M8x80

HAS, HAS-R, HAS-HCR


HAS-E, HAS-E-R

Embedment depth hef [mm] 80 90 110 125 170 210 240 270
Anchor rod
Anchor rods HIT-V (-R / -HCR) are available in variable length
HIT-V, HIT-V-R, HIT-V-HCR

Setting
installation equipment
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

10 / 2012 635
Hilti HIT-HY 150
with HIT-V / HAS

Setting instruction

Dry and water-saturated concrete, hammer drilling

a)

b)

a) Note: Manual cleaning for element sizes d 16mm and embedment depth hef 10 d only!
b) Note: Extension and piston plug needed for overhead installation and/or embedment depth > 250mm!

For detailed information on installation see instruction for use given with the package of the product.

636 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS

Working time, Curing time


Temperature Working time Curing time
a)
of the base material TBM tgel tcure
-5 C TBM < 0 C 90 min 9 h
0 C TBM < 5 C 45 min 4,5 h
5 C TBM < 10 C 20 min 2 h
10 C TBM < 20 C 6 min 90 min
20 C TBM < 30 C 4 min 50 min
30 C TBM 40 C 2 min 40 min
a) The curing time data are valid for dry anchorage base only. For water saturated anchorage bases the curing
times must be doubled.

Setting details
Marking of the
embedment depth
d0

df

Fixture
Bore hole depth h0 = anchorage depth hef Thickness tfix

Thickness of concrete member h

10 / 2012 637
Hilti HIT-HY 150
with HIT-V / HAS

Setting details
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Nominal diameter of
d0 [mm] 10 12 14 18 24 28 30 35
drill bit
Effective embedment and hef,min [mm] 60 60 70 80 90 100 110 120
drill hole depth range
a)

for HIT-V hef,max [mm] 160 200 240 320 400 480 540 600
Effective anchorage and
drill hole depth hef [mm] 80 90 110 125 170 210 240 270
for HAS
Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness 100 mm
Diameter of clearance
df [mm] 9 12 14 18 22 26 30 33
hole in the fixture
b)
Torque moment Tmax [Nm] 10 20 40 80 150 200 270 300
Minimum spacing smin [mm] 40 50 60 80 100 120 135 150
Minimum edge
cmin [mm] 40 50 60 80 100 120 135 150
distance
Critical spacing
scr,sp [mm] 2 ccr,sp
for splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


c) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N [mm] 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N [mm] 1,5 hef
d)
failure

For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a) Embedment depth range: hef,min hef hef,max
b) Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing
and/or edge distance.
c) h: base material thickness (h hmin), hef: embedment depth
d) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.

638 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS

Simplified design method


Simplified version of the design method according ETAG 001, TR 029.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HAS 5.8 [kN] 11,3 17,3 25,3 48,0 74,7 106,7 - -
HIT-V 5.8 [kN] 12,0 19,3 28,0 52,7 82,0 118,0 153,3 187,3
HAS 8.8 [kN] - - - - - - 231,3 281,3
HIT-V 8.8 [kN] 19,3 30,7 44,7 84,0 130,7 188,0 244,7 299,3
NRd,s
HAS (-E)-R [kN] 12,3 19,8 28,3 54,0 84,0 119,8 75,9 92,0
HIT-V-R [kN] 13,9 21,9 31,6 58,8 92,0 132,1 80,4 98,3
HAS (-E)-HCR [kN] 18,0 28,0 40,7 76,7 120,0 106,7 144,8 175,7
HIT-V-HCR [kN] 19,3 30,7 44,7 84,0 130,7 117,6 152,9 187,1

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth
80 90 110 125 170 210 240 270
hef = hef,typ [mm]
0
N Rd,p Temperature range I [kN] 14,7 17,3 25,3 26,9 43,2 60,3 72,7 84,8
0
N Rd,p Temperature range II [kN] 10,1 11,8 17,3 18,0 28,0 37,7 48,5 60,6
0
N Rd,p Temperature range III [kN] 8,7 10,2 15,0 15,0 25,4 33,9 38,8 48,5

10 / 2012 639
Hilti HIT-HY 150
with HIT-V / HAS

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
0
N Rd,c [kN] 24,1 24,0 32,4 33,6 53,3 73,2 89,4 106,7

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,15 a)
fB,p = (fck,cube/25N/mm) 1,00 1,03 1,06 1,09 1,11 1,13 1,14
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,5 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N 1
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp 1

f2,N = 0,5(1 + c/ccr,N) 1


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp) 1
a) The edge distance shall not be smaller than the minimum edge distance cmin. These influencing factors must
be considered for every edge distance smaller than the critical edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N) 1
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp) 1
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin. This influencing factor must
be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hef/hef,typ)

640 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HAS 5.8 [kN] 6,8 10,4 15,2 28,8 44,8 64,0 - -
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HAS 8.8 [kN] - - - - - - 139,2 168,8
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
VRd,s
HAS (-E)-R [kN] 7,7 12,2 17,3 32,7 50,6 71,8 45,8 55,5
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HAS (-E)-HCR [kN] 10,4 16,8 24,8 46,4 72,0 64,0 86,9 105,7
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 18,7 27,0 36,6 44,5 53,0

10 / 2012 641
Hilti HIT-HY 150
with HIT-V / HAS

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

642 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS

Influence of embedment depth


hef/d 4 4,5 5 6 7 8 9 10 11
0,05 (hef / d)
1,68
f hef = 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81
hef/d 12 13 14 15 16 17 18 19 20
0,05 (hef / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67

a)
Influence of edge distance
c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values design resistance values


All data applies to:
- non-cracked concrete C 20/25 fck,cube =25 N/mm
- temperature range I (see Service temperature range)
- minimum thickness of base material
- no effects of dense reinforcement

Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

10 / 2012 643
Hilti HIT-HY 150
with HIT-V / HAS

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - minimum embedment depth


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,min [mm] 60 60 70 80 90 100 110 120
Base material thickness h = hmin [mm] 100 100 100 116 138 156 170 190
Tensile NRd: single anchor, no edge effects
HIT-V 5.8
HIT-V 8.8
[kN] 11,1 11,5 16,1 17,2 20,5 24,0 27,7 31,6
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, no edge effects, without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 67,3 77,7 88,5
HIT-V 8.8 [kN] 12,0 18,4 27,2 48,2 57,5 67,3 77,7 88,5
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 67,3 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 48,2 57,5 67,3 77,7 88,5

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - minimum embedment depth


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,min [mm] 60 60 70 80 90 100 110 120
Base material thickness h = hmin [mm] 100 100 100 116 138 156 170 190
Edge distance c = cmin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
HIT-V 5.8
HIT-V 8.8
[kN] 6,7 7,8 9,7 11,0 14,5 18,1 21,0 24,8
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
HIT-V 5.8
HIT-V 8.8
[kN] 3,5 4,9 6,6 10,2 14,1 18,3 21,8 25,9
HIT-V-R
HIT-V-HCR

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - minimum embedment depth


(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,min [mm] 60 60 70 80 90 100 110 120
Base material thickness h = hmin [mm] 100 100 100 116 138 156 170 190
Spacing s = smin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
HIT-V 8.8
[kN] 7,4 7,6 10,0 10,8 13,4 16,0 18,6 21,5
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 39,4 47,1 54,7 62,7
HIT-V 8.8 [kN] 12,0 17,7 24,9 32,1 39,4 47,1 54,7 62,7
HIT-V-R [kN] 8,3 12,8 19,2 32,1 39,4 47,1 48,3 58,8
HIT-V-HCR [kN] 12,0 17,7 24,9 32,1 39,4 47,1 54,7 62,7

644 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS

esign resistance: concrete C 20/25 fck,cube = 25 N/mm - typical embedment depth


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,typ [mm] 80 90 110 125 170 210 240 270
Base material thickness h = hmin [mm] 110 120 140 161 218 266 300 340
Tensile NRd: single anchor, no edge effects
HIT-V 5.8 [kN] 12,0 17,3 25,3 26,9 43,2 60,3 72,7 84,8
HIT-V 8.8 [kN] 14,7 17,3 25,3 26,9 43,2 60,3 72,7 84,8
HIT-V-R [kN] 13,9 17,3 25,3 26,9 43,2 60,3 72,7 84,8
HIT-V-HCR [kN] 14,7 17,3 25,3 26,9 43,2 60,3 72,7 84,8
Shear VRd: single anchor, no edge effects, without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - typical embedment depth


Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,typ [mm] 80 90 110 125 170 210 240 270
Base material thickness h = hmin [mm] 110 120 140 161 218 266 300 340
Edge distance c = cmin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
HIT-V 5.8
HIT-V 8.8
[kN] 8,6 10,1 14,7 16,4 26,7 37,8 46,3 55,0
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
HIT-V 5.8
HIT-V 8.8
[kN] 3,7 5,3 7,3 11,5 17,2 23,6 29,0 34,8
HIT-V-R
HIT-V-HCR

Design resistance: concrete C 20/25 fck,cube = 25 N/mm - typical embedment depth


(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = hef,typ [mm] 80 90 110 125 170 210 240 270
Base material thickness h = hmin [mm] 110 120 140 161 218 266 300 340
Spacing s [mm] 40 50 60 80 100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
HIT-V 8.8
[kN] 9,9 11,3 16,3 17,5 28,2 39,4 47,9 56,5
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 45,7 72,4 100,5 120,9 140,7
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 45,7 72,4 70,9 92,0 112,0

10 / 2012 645
Hilti HIT-HY 150
with HIT-V / HAS

a)
Design resistance: concrete C 20/25 fck,cube = 25 N/mm - embedment depth = 12 d
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288 324 360
Base material thickness h = hmin [mm] 126 150 174 228 288 344 384 430
Tensile NRd: single anchor, no edge effects
HIT-V 5.8 [kN] 12,0 19,3 28,0 41,4 61,0 82,7 98,2 113,1
HIT-V 8.8 [kN] 17,7 23,0 33,2 41,4 61,0 82,7 98,2 113,1
HIT-V-R [kN] 13,9 21,9 31,6 41,4 61,0 82,7 80,4 98,3
HIT-V-HCR [kN] 17,7 23,0 33,2 41,4 61,0 82,7 98,2 113,1
Shear VRd: single anchor, no edge effects, without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0
a) d = element diameter
a)
Design resistance: concrete C 20/25 fck,cube = 25 N/mm - embedment depth = 12 d
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288 324 360
Base material thickness h = hmin [mm] 126 150 174 228 288 344 384 430
Edge distance c = cmin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
HIT-V 5.8
HIT-V 8.8
[kN] 10,3 13,4 19,3 25,2 37,7 51,9 62,6 73,4
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
HIT-V 5.8
HIT-V 8.8
[kN] 3,9 5,7 7,8 12,9 18,9 25,9 31,8 38,1
HIT-V-R
HIT-V-HCR
a) d = element diameter
a)
Design resistance: concrete C 20/25 fck,cube = 25 N/mm - embedment depth = 12 d
(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288 324 360
Base material thickness h = hmin [mm] 126 150 174 228 288 344 384 430
Spacing s=smin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8 [kN] 12,0 15,5 22,0 28,0 41,2 55,8 66,6 77,3
HIT-V 8.8
HIT-V-R [kN] 12,1 15,5 22,0 28,0 41,2 55,8 66,6 77,3
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0
a) d = element diameter

646 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS

10 / 2012 647
Hilti HIT-HY 150
with HIS-(R)N

Hilti HIT-HY 150 with HIS-(R)N


Injection mortar system Benefits

- suitable for non-cracked concrete


Hilti C 20/25 to C 50/60
HIT-HY 150
330 ml foil pack - suitable for dry and water
saturated concrete
(also available - high loading capacity
as 500 ml
and 1400 ml - rapid curing
foil pack) - small edge distance and anchor
spacing possible
- corrosion resistant
Static mixer - in service temperature range up
to 120C short term/72C long
Internal term
threaded sleeve - manual cleaning for anchor size
HIS-N M8 and M10
HIS-RN

PROFIS
Small edge
Corrosion Anchor
Concrete distance
resistance design
and spacing
software

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range -5C to +40C

Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended
loads.
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
Base material thickness h [mm] 120 150 170 230 270

648 10 / 2012
Hilti HIT-HY 150
with HIS-(R)N

Mean ultimate resistance: non-cracked concrete C 20/25 , anchor HIS-N


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Tensile NRu,m HIS-N [kN] 26,3 48,3 70,4 123,9 114,5
Shear VRu,m HIS-N [kN] 13,7 24,2 41,0 62,0 57,8

Characteristic resistance: non-cracked concrete C 20/25 , anchor HIS-N


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Tensile NRk HIS-N [kN] 25,0 40,0 60,0 111,9 109,0
Shear VRk HIS-N [kN] 13,0 23,0 39,0 59,0 55,0

Design resistance: non-cracked concrete C 20/25 , anchor HIS-N


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Tensile NRd HIS-N [kN] 17,5 26,7 40,0 62,2 74,1
Shear VRd HIS-N [kN] 10,4 18,4 26,0 39,3 36,7

Recommended loads a): non-cracked concrete C 20/25 , anchor HIS-N


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Tensile Nrec HIS-N [kN] 12,5 19,0 28,6 44,4 53,0
Shear Vrec HIS-N [kN] 7,4 13,1 18,6 28,1 26,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-HY 150 injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +80 C +50 C +80 C
Temperature range III -40 C to +120 C +72 C +120 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

10 / 2012 649
Hilti HIT-HY 150
with HIS-(R)N

Materials
Mechanical properties of HIS-(R)N
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
HIS-N [N/mm] 490 490 460 460 460
Nominal Screw 8.8 [N/mm] 800 800 800 800 800
tensile
strength fuk HIS-RN [N/mm] 700 700 700 700 700
Screw A4-70 [N/mm] 700 700 700 700 700
HIS-N [N/mm] 410 410 375 375 375
Yield Screw 8.8 [N/mm] 640 640 640 640 640
strength fyk HIS-RN [N/mm] 350 350 350 350 350
Screw A4-70 [N/mm] 450 450 450 450 450
Stressed HIS-(R)N [mm] 51,5 108,0 169,1 256,1 237,6
cross-
section As Screw [mm] 36,6 58 84,3 157 245
Moment of HIS-(R)N [mm] 145 430 840 1595 1543
resistance W Screw [mm] 31,2 62,3 109 277 541

Material quality
Part Material
a)
Internal threaded sleeve C-steel 1.0718,
HIS-N Steel galvanized 5m
a)
Internal threaded sleeve
Stainless steel 1.4401 and 1.4571
HIS-RN
a) related fastening screw: strength class 8.8, A5 > 8% Ductile
steel galvanized 5m
b) related fastening screw: strength class 70, A5 > 8% Ductile
stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362

Anchor dimensions
Anchor size
Internal threaded sleeve M8x90 M10x110 M12x125 M16x170 M20x205
HIS-N / HIS-RN
Embedment depth hef [mm] 80 90 110 125 170

Setting
installation equipment
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

650 10 / 2012
Hilti HIT-HY 150
with HIS-(R)N

Setting instruction

Dry and water-saturated concrete, hammer drilling

a)

b)

a) Note: Manual cleaning for HIS-(R)N M8 and HIS-(R)N M10 only!


b) Note: Extension and piston plug needed for overhead installation!

For detailed information on installation see instruction for use given with the package of the product.

10 / 2012 651
Hilti HIT-HY 150
with HIS-(R)N

Working time, Curing time


Temperature Working time Curing time
a)
of the base material TBM tgel tcure
-5 C TBM < 0 C 90 min 9 h
0 C TBM < 5 C 45 min 4,5 h
5 C TBM < 10 C 20 min 2 h
10 C TBM < 20 C 6 min 90 min
20 C TBM < 30 C 4 min 50 min
30 C TBM 40 C 2 min 40 min
a) The curing time data are valid for dry anchorage base only. For water saturated anchorage bases the curing
times must be doubled.

Setting details
hS

df
d
d0

Bore hole depth h0 =


Embedment depth hef

652 10 / 2012
Hilti HIT-HY 150
with HIS-(R)N

Anchor size M8x90 M10x110 M12x125 M16x170 M20x205


Nominal diameter of
d0 [mm] 14 18 22 28 32
drill bit
Diameter of element d [mm] 12,5 16,5 20,5 25,4 27,6
Effective anchorage
hef [mm] 90 110 125 170 205
and drill hole depth
Minimum base
hmin [mm] 120 150 170 230 270
material thickness
Diameter of clearance
df [mm] 9 12 14 18 22
hole in the fixture
Thread engagement
hs [mm] 8-20 10-25 12-30 16-40 20-50
length; min - max
a)
Torque moment Tmax [Nm] 10 20 40 80 150
Minimum spacing smin [mm] 40 45 55 65 90
Minimum edge
cmin [mm] 40 45 55 65 90
distance
Critical spacing
scr,sp [mm] 2 ccr,sp
for splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


b) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N [mm] 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N [mm] 1,5 hef
c)
failure

For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a) Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing
and/or edge distance.
b) h: base material thickness (h hmin), hef: embedment depth
c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.

10 / 2012 653
Hilti HIT-HY 150
with HIS-(R)N

Simplified design method


Simplified version of the design method according ETAG 001, TR 029.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
HIS-N [kN] 17,5 30,7 44,7 80,3 74,1
NRd,s
HIS-RN [kN] 13,9 21,9 31,6 58,8 69,2

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
0
N Rd,p Temperature range I [kN] 23,3 26,7 40,0 63,9 77,8
0
N Rd,p Temperature range II [kN] 13,3 20,0 26,7 41,7 52,8
0
N Rd,p Temperature range III [kN] 10,7 13,3 20,0 27,8 33,3

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size M8 M10 M12 M16 M20
0
N Rd,c [kN] 28,7 38,8 47,1 62,2 82,3

654 10 / 2012
Hilti HIT-HY 150
with HIS-(R)N

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,15 a)
fB,p = (fck,cube/25N/mm) 1,00 1,03 1,06 1,09 1,11 1,13 1,14
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = 1

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,5 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N 1
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp 1

f2,N = 0,5(1 + c/ccr,N) 1


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp) 1
a) The edge distance shall not be smaller than the minimum edge distance cmin. These influencing factors must
be considered for every edge distance smaller than the critical edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N) 1
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp) 1
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin. This influencing factor must
be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


fh,N = 1

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.

10 / 2012 655
Hilti HIT-HY 150
with HIS-(R)N

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
VRd,s
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
0
V Rd,c [kN] 12,4 19,6 28,2 40,2 46,2

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

656 10 / 2012
Hilti HIT-HY 150
with HIS-(R)N

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


Anchor size M8 M10 M12 M16 M20
f hef = 1,38 1,21 1,04 1,22 1,45

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values design resistance values


All data applies to:
- non-cracked concrete C 20/25 fck,cube =25 N/mm
- temperature range I (see Service temperature range)
- minimum thickness of base material
- no effects of dense reinforcement

10 / 2012 657
Hilti HIT-HY 150
with HIS-(R)N

Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

Design resistance: non-cracked- concrete C 20/25


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
Base material thickness h = hmin [mm] 120 150 170 230 270
Tensile NRd: single anchor, no edge effects
HIS-N [kN] 17,5 26,7 40,0 62,2 74,1
HIS-RN [kN] 13,9 21,9 31,6 58,8 69,2
Shear VRd: single anchor, no edge effects, without lever arm
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

Design resistance: non-cracked- concrete C 20/25


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
Base material thickness h = hmin [mm] 120 150 170 230 270
Edge distance c = cmin [mm] 40 45 55 65 90
Tensile NRd: single single anchor, min. edge distance (c = cmin)
HIS-N [kN] 11,9 13,4 20,4 27,5 37,4
HIS-RN [kN] 11,9 13,4 20,4 27,5 37,4
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
HIS-N [kN] 4,2 5,5 7,6 10,8 17,2
HIS-RN [kN] 4,2 5,5 7,6 10,8 17,2

Design resistance: non-cracked- concrete C 20/25


Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
Base material thickness h = hmin [mm] 120 150 170 230 270
Spacing s = smin [mm] 40 45 55 65 90
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIS-N [kN] 14,3 16,9 24,2 33,8 45,2
HIS-RN [kN] 13,9 16,9 24,2 33,8 45,2
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

658 10 / 2012
Hilti HIT-HY 150
with HIS-(R)N

10 / 2012 659
Hilti HIT-HY 150
with rebar

Hilti HIT-HY 150 with rebar


Injection mortar system Benefits
- suitable for non-cracked concrete
Hilti C 20/25 to C 50/60
HIT-HY 150 - suitable for dry and water
330 ml foil pack saturated concrete
(also available - high loading capacity
as 500 ml - rapid curing
and 1400 ml - small edge distance and anchor
foil pack) spacing possible
- large diameter applications
- in service temperature range up
Static mixer to 120C short term/72C long
term
- manual cleaning for anchor size
8 to 14 and embedment depth
hef 10d
rebar BSt 500 S - embedment depth range
8: 60 to 160 mm
25: 120 to 500 mm

PROFIS
Small edge Variable
Anchor
Concrete distance embedment
design
and spacing depth
software

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- Anchor material: rebar BSt 500 S
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperate range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range -5C to +40C

660 10 / 2012
Hilti HIT-HY 150
with rebar

Embedment depth a) and base material thickness for the basic loading data. Mean
ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size 8 10 12 14 16 20 25
b)
Embedment depth hef = hef,typ [mm] 80 90 110 125 170 210 240
Base material thickness h [mm] 110 120 140 165 220 270 300
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.
b) hef,typ: Typical embedment depth

Mean ultimate resistance: non-cracked concrete C 20/25 , anchor BSt 500 S


Anchor size 8 10 12 14 16 20 25
Tensile NRu,m BST 500 S [kN] 22,8 32,0 47,0 55,0 72,9 106,8 164,9
Shear VRu,m BST 500 S [kN] 14,7 23,1 32,6 44,1 57,8 90,3 141,8

Characteristic resistance: non-cracked concrete C 20/25 , anchor BSt 500 S


Anchor size 8 10 12 14 16 20 25
Tensile NRk BST 500 S [kN] 17,1 24,0 35,2 41,2 54,7 80,1 123,7
Shear VRk BST 500 S [kN] 14,0 22,0 31,0 42,0 55,0 86,0 135,0

Design resistance: non-cracked concrete C 20/25 , anchor BSt 500 S


Anchor size 8 10 12 14 16 20 25
Tensile NRd BST 500 S [kN] 11,4 13,4 19,6 19,6 26,0 38,1 58,9
Shear VRd BST 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0

Recommended loads a): non-cracked concrete C 20/25 , anchor BSt 500 S


Anchor size 8 10 12 14 16 20 25
Tensile Nrec BST 500 S [kN] 8,1 9,5 14,0 14,0 18,6 27,2 42,1
Shear Vrec BST 500 S [kN] 6,7 10,5 14,8 20,0 26,2 41,0 64,3
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-HY 150 injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +24 C +40 C
Temperature range II -40 C to +80 C +50 C +80 C
Temperature range III -40 C to +120 C +72 C +120 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

10 / 2012 661
Hilti HIT-HY 150
with rebar

Materials
Mechanical properties of rebar BSt 500S
Anchor size 8 10 12 14 16 20 25
Nominal
tensile BSt 500 S [N/mm] 550
strength fuk
Yield
BSt 500 S [N/mm] 500
strength fyk
Stressed
cross- BSt 500 S [mm] 50,3 78,5 113,1 153,9 201,1 314,2 490,9
section As
Moment of
resistance BSt 500 S [mm] 50,3 98,2 169,6 269,4 402,1 785,4 1534
W

Material quality
Part Material
rebar Mechanical properties according to DIN 488-1:1984
BSt 500 S Geometry according to DIN 488-21:1986

Anchor dimensions
Anchor size 8 10 12 14 16 20 25
rebar
rebar are available in variable length
BSt 500 S

Setting
installation equipment
Anchor size 8 10 12 14 16 20 25
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

662 10 / 2012
Hilti HIT-HY 150
with rebar

Setting instruction

Dry and water-saturated concrete, hammer drilling

a)

b)

a) Note: Manual cleaning for element sizes d 14mm and embedment depth hef 10 d only!
b) Note: Extension and piston plug needed for overhead installation and/or embedment depth > 250mm!

For detailed information on installation see instruction for use given with the package of the product.

10 / 2012 663
Hilti HIT-HY 150
with rebar

Working time, Curing time


Temperature Working time Curing time
a)
of the base material TBM tgel tcure
-5 C TBM < 0 C 90 min 9 h
0 C TBM < 5 C 45 min 4,5 h
5 C TBM < 10 C 20 min 2 h
10 C TBM < 20 C 6 min 90 min
20 C TBM < 30 C 4 min 50 min
30 C TBM 40 C 2 min 40 min
a) The curing time data are valid for dry anchorage base only. For water saturated anchorage bases the curing
times must be doubled.

Setting details
d0

Bore hole depth h0 = embedment depth hef

Thickness of concrete member h

664 10 / 2012
Hilti HIT-HY 150
with rebar

Anchor size 8 10 12 14 16 20 25
Nominal diameter of
d0 [mm] 12 14 16 18 20 25 32
drill bit
Effective embedment and hef,min [mm] 60 60 70 75 80 90 100
drill hole depth range
a)

for rebar BSt 500 S hef,max [mm] 160 200 240 280 320 400 500
Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness 100 mm
Minimum spacing smin [mm] 40 50 60 70 80 100 150
Minimum edge
cmin [mm] 40 50 60 80 100 120 150
distance
Critical spacing
scr,sp [mm] 2 ccr,sp
for splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


b) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N [mm] 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N [mm] 1,5 hef
c)
failure

For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a) Embedment depth range: hef,min hef hef,max
b) h: base material thickness (h hmin), hef: embedment depth
c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.

10 / 2012 665
Hilti HIT-HY 150
with rebar

Simplified design method


Simplified version of the design method according ETAG 001, TR 029.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Anchor size 8 10 12 14 16 20 25
NRd,s BSt 500 S [kN] 20,0 30,7 44,3 60,7 79,3 123,6 192,9

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Anchor size 8 10 12 14 16 20 25
Embedment depth hef =
[mm] 80 90 110 125 145 170 210
Typical embedment depth hef,typ
0
N Rd,p Temperature range I [kN] 11,4 13,4 19,6 19,6 26,0 38,1 58,9
0
N Rd,p Temperature range II [kN] 8,0 9,4 13,8 13,1 17,4 25,4 39,3
0
N Rd,p Temperature range III [kN] 6,7 7,9 11,5 11,8 15,6 22,9 35,3

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size 8 10 12 14 16 20 25
0
N Rd,c [kN] 24,1 24,0 32,4 33,6 42,0 53,3 73,2

666 10 / 2012
Hilti HIT-HY 150
with rebar

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,15 a)
fB,p = (fck,cube/25N/mm) 1,00 1,03 1,06 1,09 1,11 1,13 1,14
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = hef/hef,typ

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,5 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N 1
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp 1

f2,N = 0,5(1 + c/ccr,N) 1


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp) 1
a) The edge distance shall not be smaller than the minimum edge distance cmin. These influencing factors must
be considered for every edge distance smaller than the critical edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N) 1
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp) 1
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin. This influencing factor must
be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


1,5
fh,N = (hef/hef,typ)

Influence of reinforcement
hef [mm] 40 50 60 70 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.

10 / 2012 667
Hilti HIT-HY 150
with rebar

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Anchor size 8 10 12 14 16 20 25
VRd,s Rebar BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size 8 10 12 14 16 20 25
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 15,0 18,7 27,0 39,2

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

668 10 / 2012
Hilti HIT-HY 150
with rebar

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


hef/d 4 4,5 5 6 7 8 9 10 11
0,05 (hef / d)
1,68
f hef = 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81

hef/d 12 13 14 15 16 17 18 19 20
0,05 (hef / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values design resistance values


All data applies to:
- non-cracked concrete C 20/25 fck,cube =25 N/mm
- temperature range I (see Service temperature range)
- minimum thickness of base material
- no effects of dense reinforcement

10 / 2012 669
Hilti HIT-HY 150
with rebar

Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

Design resistance: non- cracked concrete C 20/25 - minimum embedment depth


Anchor size 8 10 12 14 16 20 25
Embedment depth hef = hef,min [mm] 60 60 70 80 90 100 110
Base material thickness h = hmin [mm] 100 100 102 116 130 150 174
Tensile NRd: single anchor, no edge effects

BSt 500 S [kN] 8,5 8,9 12,5 12,6 16,2 22,4 27,7

Shear VRd: single anchor, no edge effects, without lever arm

BSt 500 S [kN] 9,3 14,7 20,7 25,1 32,3 44,9 55,5

Design resistance: non- cracked concrete C 20/25 - minimum embedment depth


Anchor size 8 10 12 14 16 20 25
Embedment depth hef = hef,min [mm] 60 60 70 80 90 100 110
Base material thickness h = hmin [mm] 100 100 102 116 130 150 174
Edge distance c = cmin [mm] 40 50 60 80 100 120 135
Tensile NRd: single anchor, min. edge distance (c = cmin)

BSt 500 S [kN] 5,3 6,0 8,5 9,4 13,0 17,4 21,5

Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm

BSt 500 S [kN] 3,5 4,9 6,6 10,0 13,2 17,4 21,8

Design resistance: non- cracked concrete C 20/25 - minimum embedment depth


(load values are valid for single anchor)
Anchor size 8 10 12 14 16 20 25
Embedment depth hef = hef,min [mm] 60 60 70 80 90 100 110
Base material thickness h = hmin [mm] 100 100 100 116 138 156 170
Spacing s = smin [mm] 40 50 60 80 100 120 135
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)

BSt 500 S [kN] 5,9 6,2 8,5 8,7 11,1 15,2 19,3

Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm

BSt 500 S [kN] 9,3 11,4 16,0 16,2 20,9 29,9 40,4

670 10 / 2012
Hilti HIT-HY 150
with rebar

Design resistance: non- cracked concrete C 20/25 - typical embedment depth


Anchor size 8 10 12 14 16 20 25
Embedment depth hef = hef,typ [mm] 80 90 110 125 145 170 210
Base material thickness h = hmin [mm] 110 120 142 161 185 220 274
Tensile NRd: single anchor, no edge effects

BSt 500 S [kN] 11,4 13,4 19,6 19,6 26,0 38,1 58,9

Shear VRd: single anchor, no edge effects, without lever arm

BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0

Design resistance: non- cracked concrete C 20/25 - typical embedment depth


Anchor size 8 10 12 14 16 20 25
Embedment depth hef = hef,typ [mm] 80 90 110 125 145 170 210
Base material thickness h = hmin [mm] 110 120 142 161 185 220 274
Edge distance c = cmin [mm] 40 50 60 80 100 120 135
Tensile NRd: single anchor, min. edge distance (c = cmin)

BSt 500 S [kN] 7,0 8,3 12,1 13,4 18,8 26,9 37,0

Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm

BSt 500 S [kN] 3,7 5,3 7,3 11,2 15,8 21,5 27,5

Design resistance: non- cracked concrete C 20/25 - typical embedment depth


(load values are valid for single anchor)
Anchor size 8 10 12 14 16 20 25
Embedment depth hef = hef,typ [mm] 80 90 110 125 145 170 210
Base material thickness h = hmin [mm] 110 120 142 161 185 220 274
Spacing s = smin [mm] 40 50 60 80 100 120 135
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)

BSt 500 S [kN] 8,0 9,3 13,4 13,7 18,0 25,8 40,2

Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm

BSt 500 S [kN] 9,3 14,7 20,7 23,3 30,8 45,6 72,9

10 / 2012 671
Hilti HIT-HY 150
with rebar

a)
Design resistance: non- cracked concrete C 20/25 - embedment depth = 12 d
Anchor size 8 10 12 14 16 20 25
Embedment depth hef = 12 d a) [mm] 96 120 144 168 192 240 300
Base material thickness h = hmin [mm] 126 150 176 204 232 290 364
Tensile NRd: single anchor, no edge effects

BSt 500 S [kN] 13,7 17,8 25,6 26,4 34,5 53,9 84,1

Shear VRd: single anchor, no edge effects, without lever arm

BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0

a)
Design resistance: non- cracked concrete C 20/25 - embedment depth = 12 d
Anchor size 8 10 12 14 16 20 25
Embedment depth hef = 12 d a) [mm] 96 120 144 168 192 240 300
Base material thickness h = hmin [mm] 126 150 176 204 232 290 364
Edge distance c = cmin [mm] 40 50 60 80 100 120 135
Tensile NRd: single anchor, min. edge distance (c = cmin)

BSt 500 S [kN] 8,4 11,0 15,8 18,1 24,9 37,9 55,9

Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm

BSt 500 S [kN] 3,9 5,7 7,8 12,0 16,9 23,6 30,5

a)
Design resistance: non- cracked concrete C 20/25 - embedment depth = 12 d
(load values are valid for single anchor)
Anchor size 8 10 12 14 16 20 25
Embedment depth hef = 12 d a) [mm] 96 120 144 168 192 240 300
Base material thickness h = hmin [mm] 126 150 176 204 232 290 364
Spacing s = smin [mm] 40 50 60 80 100 120 135
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)

BSt 500 S [kN] 9,7 12,5 17,9 18,7 24,2 37,3 59,2

Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm

BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0

a) d = element diameter

672 10 / 2012
Hilti HIT-HY 150
with rebar

10 / 2012 673
Hilti HIT-ICE
with HIT-V / HAS

Hilti HIT-ICE with HIT-V / HAS


Injection mortar system Benefits

Hilti - suitable for non-cracked concrete


HIT-ICE C 20/25 to C 50/60
296 ml cartridge - high loading capacity
- suitable for dry and water
saturated concrete
- high corrosion resistant
Statik mixer - odourless resin
- low installation temperature
(range -23 C to +32 C)
HAS rod

HAS-E rod

HIT-V rod

PROFIS
Small edge High
Corrosion Anchor
Concrete distance corrosion
resistance design
and spacing resistance
software

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Installation temperature range -18C to +32C

Embedment depth a) and base material thickness for the basic loading data. Mean
ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size M8 M10 M12 M16 M20 M24
Embedment depth [mm] 80 90 110 125 170 210
Base material thickness [mm] 110 120 140 165 220 270
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.

674 10 / 2012
Hilti HIT-ICE
with HIT-V / HAS

Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8
Hilti technical data
Anchor size M8 M10 M12 M16 M20 M24
Tensile NRu,m HIT-V 5.8 [kN] 18,9 30,5 44,1 59,9 101,9 127,1
Shear VRu,m HIT-V 5.8 [kN] 9,5 15,8 22,1 41,0 64,1 92,4

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8


Hilti technical data
Anchor size M8 M10 M12 M16 M20 M24
Tensile NRk HIT-V 5.8 [kN] 17,6 23,5 35,3 44,9 76,4 95,3
Shear VRk HIT-V 5.8 [kN] 9,0 15,0 21,0 39,0 61,0 88,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8


Hilti technical data
Anchor size M8 M10 M12 M16 M20 M24
Tensile NRd HIT-V 5.8 [kN] 8,4 11,2 16,8 21,4 36,4 45,4
Shear VRd HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8
Hilti technical data
Anchor size M8 M10 M12 M16 M20 M24
Tensile Nrec HIT-V 5.8 [kN] 6,0 8,0 12,0 15,3 26,0 32,4
Shear Vrec HIT-V 5.8 [kN] 5,1 8,6 12,0 22,3 34,9 50,3
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-ICE injection mortar may be applied in the temperature range given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +70 C +43 C +70 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

10 / 2012 675
Hilti HIT-ICE
with HIT-V / HAS

Materials
Mechanical properties of HIT-V / HAS
Hilti technical data
Anchor size M8 M10 M12 M16 M20 M24
HIT-V/HAS 5.8 [N/mm] 500 500 500 500 500 500
Nominal HIT-V 8.8 [N/mm] 800 800 800 800 800 800
tensile
strength fuk HIT-V/HAS -R [N/mm] 700 700 700 700 700 700
HIT-V/HAS -HCR [N/mm] 800 800 800 800 800 700
HIT-V/HAS 5.8 [N/mm] 400 400 400 400 400 400
Yield HIT-V 8.8 [N/mm] 640 640 640 640 640 640
strength fyk HIT-V/HAS -R [N/mm] 450 450 450 450 450 450
HIT-V/HAS -HCR [N/mm] 600 600 600 600 600 400
Stressed HAS [mm] 32,8 52,3 76,2 144 225 324
cross-
section As HIT-V [mm] 36,6 58,0 84,3 157 245 353
Moment of HAS [mm] 27,0 54,1 93,8 244 474 809
resistance
W HIT-V [mm] 31,2 62,3 109 277 541 935

Material quality
Part Material
Strength class 5.8, A5 > 8% ductile
Threaded rod
steel galvanized 5 m,
HIT-V(F), HAS 5.8
(F) hot dipped galvanized 45 m,
Strength class 8.8, A5 > 8% ductile
Threaded rod
steel galvanized 5 m,
HIT-V(F) 8.8
(F) hot dipped galvanized 45 m,
Stainless steel grade A4, A5 > 8% ductile
Threaded rod
strength class 70,
HIT-V-R, HAS-R
1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, 1.4529; 1.4565
Threaded rod
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
HIT-V-HCR, HAS-HCR
M24: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, hot dipped galvanized,
Washer
Stainless steel, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
ISO 7089
High corrosion resistant steel, 1.4529; 1.4565
Strength class 8,
steel galvanized 5 m,
hot dipped galvanized 45 m,
Nut
Strength class 70, stainless steel grade A4,
EN ISO 4032
1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, high corrosion resistant steel,
1.4529; 1.4565

676 10 / 2012
Hilti HIT-ICE
with HIT-V / HAS

Anchor dimensions
Anchor size M8 M10 M12 M16 M20 M24

Anchor rod

M12x110

M16x125

M20x170

M24x210
M10x90
M8x80
HAS, HAS-E,
HAS-R, HAS-ER
HAS-HCR

Anchor embedment depth [mm] 80 90 110 125 170 210


Anchor rod
Anchor rods HIT-V (-R / -HCR) are available in variable length
HIT-V, HIT-V-R, HIT-V-HCR

Setting
installation equipment
Anchor size M8 M10 M12 M16 M20 M24
Rotary hammer TE 2 TE 16 TE 40 TE 50
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

Setting instruction

Dry and water-saturated concrete, hammer drilling

a)

10 / 2012 677
Hilti HIT-ICE
with HIT-V / HAS

a) Note: Manual cleaning for element sizes d 16mm and embedment depth hef 10 d only!
Brush bore hole with required steel brush HIT-RB
For detailed information on installation see instruction for use given with the package of the product.

Curing time for general conditions


Hilti technical data
Temperature Curing time before anchor Working time in which anchor
of the base material can be fully loaded tcure can be inserted and adjusted tgel
32 C 35 min 1 min
21 C 45 min 2,5 min
16 C 1h 5 min
4 C 1h 15 min
- 7 C 6h 1h
- 18 C 24 h 1,5 h
- 23 C 36 h 1,5 h

678 10 / 2012
Hilti HIT-ICE
with HIT-V / HAS

Setting details
Hilti technical data
Anchor size M8 M10 M12 M16 M20 M24
Nominal diameter of
d0 [mm] 10 12 14 18 24 28
drill bit
Effective anchorage
hef [mm] 80 90 110 125 170 210
and drill hole depth
Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness
b)
100 mm
Diameter of clearance
df [mm] 9 12 14 18 22 26
hole in the fixture
Minimum spacing smin [mm] 40 50 60 80 100 120
Minimum edge
cmin [mm] 40 50 60 80 100 120
distance
Critical spacing for
scr,sp 2 ccr,sp
splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


c) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N 1.5 hef
b)
failure
c)
Torque moment Tinst [Nm] 10 20 40 80 150 200

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) h: base material thickness (h hmin)
b) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
c) This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.

10 / 2012 679
Hilti HIT-ICE
with HIT-V / HAS

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given by
Hilti.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Hilti technical data
Anchor size M8 M10 M12 M16 M20 M24
HAS 5.8 [kN] 11,1 17,6 25,4 48,1 74,8 106,8
HIT-V 5.8 [kN] 12,0 19,3 28,0 52,7 82,0 118,0
HIT-V 8.8 [kN] 19,3 30,7 44,7 84,0 130,7 188,0
NRd,s HAS (-E)-R [kN] 12,4 19,8 28,6 54,1 84,1 120,2
HIT-V-R [kN] 13,9 21,9 31,6 58,8 92,0 132,1
HAS (-E)-HCR [kN] 17,7 28,2 40,6 76,9 119,6 106,8
HIT-V-HCR [kN] 19,3 30,7 44,7 84,0 130,7 117,6

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Hilti technical data
Anchor size M8 M10 M12 M16 M20 M24
Typical embedment depth
80 90 110 125 170 210
hef,typ [mm]
0
N Rd,p Temperature range I [kN] 8,4 11,2 16,8 21,4 36,4 45,4

680 10 / 2012
Hilti HIT-ICE
with HIT-V / HAS

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Hilti technical data
Anchor size M8 M10 M12 M16 M20 M24
0
N Rd,c [kN] 17,2 20,5 27,7 33,6 53,3 73,2

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,1 a)
fB,p = (fck,cube/25N/mm) 1 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = 1

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on concrete cone resistance


fh,N = 1

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

10 / 2012 681
Hilti HIT-ICE
with HIT-V / HAS

Influence of reinforcement
hef [mm] 80 90 100
fre,N = 0,5 + hef/200mm 1
a) a)
0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Hilti technical data
Anchor size M8 M10 M12 M16 M20 M24
HAS 5.8 [kN] 6,6 10,6 15,2 28,8 44,9 64,1
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8
VRd,s HAS (-E)-R [kN] 7,5 11,9 17,1 32,4 50,5 72,1
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5
HAS (-E)-HCR [kN] 10,6 16,9 24,4 46,1 71,8 64,1
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9

Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k=2
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20 M24
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 18,7 27,0 36,6

682 10 / 2012
Hilti HIT-ICE
with HIT-V / HAS

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


Anchor size M8 M10 M12 M16 M20 M24
0,05 (hef / d)
1,68
f hef = 2,39 2 2,07 1,58 1,82 1,91

10 / 2012 683
Hilti HIT-ICE
with HIT-V / HAS

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

684 10 / 2012
Hilti HIT-ICE
with HIT-V / HAS

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Hilti technical data
Anchor size M8 M10 M12 M16 M20 M24
Embedment depth hef,typ = [mm] 80 90 110 125 170 210
Base material thickness hmin= [mm] 110 120 140 161 218 266
Tensile NRd: single anchor, no edge effects
HIT-V 5.8
HIT-V 8.8
[kN] 8,4 11,2 16,8 21,4 36,4 45,4
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, no edge effects, without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Hilti technical data
Anchor size M8 M10 M12 M16 M20 M24
Embedment depth hef,typ = [mm] 80 90 110 125 170 210
Base material thickness hmin= [mm] 110 120 140 161 218 266
Edge distance c = cmin= [mm] 40 50 60 80 100 120
Tensile NRd: single anchor, min. edge distance (c = cmin)
HIT-V 5.8
HIT-V 8.8
[kN] 5,2 7,0 10,4 13,8 23,5 30,7
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
HIT-V 5.8
HIT-V 8.8
[kN] 3,7 5,3 7,3 11,5 17,2 23,6
HIT-V-R
HIT-V-HCR

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


(load values are valid for single anchor)
Hilti technical data
Anchor size M8 M10 M12 M16 M20 M24
Embedment depth hef,typ = [mm] 80 90 110 125 170 210
Base material thickness hmin= [mm] 110 120 140 161 218 266
Spacing s = smin= [mm] 40 50 60 80 100 120
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
HIT-V 8.8
[kN] 5,9 7,8 11,5 14,8 24,9 31,9
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4
HIT-V 8.8 [kN] 12,0 18,4 27,2 36,4 61,0 75,7
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 75,7
HIT-V-HCR [kN] 12,0 18,4 27,2 36,4 61,0 70,9

10 / 2012 685
Hilti HIT-ICE
with HIS-(R)N

Hilti HIT-ICE with HIS-(R)N


Injection mortar system Benefits

Hilti - suitable for non-cracked concrete


HIT-ICE C 20/25 to C 50/60
296 ml cartridge - high loading capacity
- suitable for dry and water
saturated concrete
- odourless resin
Statik mixer
- low installation temperature
(range -23 C to +32 C)

HIS-(R)N sleeve

PROFIS
Small edge
Corrosion Anchor
Concrete distance
resistance design
and spacing
software

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Screw strength class 8.8
- Base material thickness, as specified in the table
- Embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Installation temperature range -18C to +32C

Embedment depth and base material thickness for the basic loading data. Mean ultimate
resistance, characteristic resistance, design resistance, recommended loads.
Anchor size M8 M10 M12 M16 M20
Embedment depth [mm] 90 110 125 170 205
Base material thickness [mm] 120 150 170 230 270

Mean ultimate resistance a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N
Hilti technical data
Anchor size M8 M10 M12 M16 M20
Tensile NRu,m HIS-N [kN] 27,3 48,2 61,0 105,6 114,5
Shear VRu,m HIS-N [kN] 13,7 24,2 41,0 62,0 57,8

686 10 / 2012
Hilti HIT-ICE
with HIS-(R)N

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N


Hilti technical data
Anchor size M8 M10 M12 M16 M20
Tensile NRk HIS-N [kN] 24,2 36,1 45,8 79,2 94,7
Shear VRk HIS-N [kN] 13,0 23,0 39,0 59,0 55,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N


Hilti technical data
Anchor size M8 M10 M12 M16 M20
Tensile NRd HIS-N [kN] 11,5 17,2 21,8 37,7 45,1
Shear VRd HIS-N [kN] 10,4 18,4 26,0 39,3 36,7

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N


Hilti technical data
Anchor size M8 M10 M12 M16 M20
Tensile Nrec HIS-N [kN] 8,2 12,3 15,6 26,9 32,2
Shear Vrec HIS-N [kN] 7,4 13,1 18,6 28,1 26,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-ICE injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +70 C +43 C +70 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

10 / 2012 687
Hilti HIT-ICE
with HIS-(R)N

Materials
Mechanical properties of HIS-(R)N
Hilti technical data
Anchor size M8 M10 M12 M16 M20
HIS-N [N/mm] 490 490 460 460 460
Nominal Screw 8.8 [N/mm] 800 800 800 800 800
tensile
strength fuk HIS-RN [N/mm] 700 700 700 700 700
Screw A4-70 [N/mm] 700 700 700 700 700
HIS-N [N/mm] 410 410 375 375 375
Yield Screw 8.8 [N/mm] 640 640 640 640 640
strength fyk HIS-RN [N/mm] 350 350 350 350 350
Screw A4-70 [N/mm] 450 450 450 450 450
Stressed HIS-(R)N [mm] 51,5 108,0 169,1 256,1 237,6
cross-
section As Screw [mm] 36,6 58 84,3 157 245
Moment of HIS-(R)N [mm] 145 430 840 1595 1543
resistance W Screw [mm] 31,2 62,3 109 277 541

Material quality
Part Material
a)
internally threaded sleeves C-steel 1.0718,
HIS-N steel galvanized 5m
b)
internally threaded sleeves
stainless steel 1.4401 and 1.4571
HIS-RN
a) related fastening screw: strength class 8.8, A5 > 8% Ductile
steel galvanized 5m
b) related fastening screw: strength class 70, A5 > 8% Ductile
stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362

Anchor dimensions
Anchor size M8 M10 M12 M16 M20
Internal sleeve
M8x90 M10x110 M12x125 M16x170 M20x205
HIS-(R)N
Anchor embedment depth [mm] 90 110 125 170 205

Setting
installation equipment
Anchor size M8 M10 M12 M16 M20
Rotary hammer TE 2 TE 16 TE 40 TE 50
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

688 10 / 2012
Hilti HIT-ICE
with HIS-(R)N

Setting instruction

Dry and water-saturated concrete, hammer drilling

a)

a) Note: Manual cleaning for HIS-(R)N M8 and HIS-(R)N M10 only!


Brush bore hole with required steel brush HIT-RB
For detailed information on installation see instruction for use given with the package of the product.

10 / 2012 689
Hilti HIT-ICE
with HIS-(R)N

Curing time for general conditions


Hilti technical data
Temperature Curing time before anchor Working time in which anchor
of the base material can be fully loaded tcure can be inserted and adjusted tgel
32 C 35 min 1 min
21 C 45 min 2,5 min
16 C 1h 5 min
4 C 1h 15 min
- 7 C 6h 1h
- 18 C 24 h 1,5 h
- 23 C 36 h 1,5 h

690 10 / 2012
Hilti HIT-ICE
with HIS-(R)N

Setting details
Hilti technical data
Anchor size M8 M10 M12 M16 M20
Nominal diameter of
d0 [mm] 14 18 22 28 32
drill bit
Diameter of element d [mm] 12,5 16,5 20,5 25,4 27,6
Effective anchorage
hef [mm] 90 110 125 170 205
and drill hole depth
Minimum base
a) hmin [mm] 120 150 170 230 270
material thickness
Diameter of clearance
df [mm] 9 12 14 18 22
hole in the fixture
Thread engagement
hs [mm] 8-20 10-25 12-30 16-40 20-50
length; min - max
Minimum spacing smin [mm] 40 45 55 65 90
Minimum edge
cmin [mm] 40 45 55 65 90
distance
Critical spacing for
scr,sp 2 ccr,sp
splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


a) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N 2 ccr,N
concrete cone failure
Critical edge distance
b)
for concrete cone ccr,N 1.5 hef
failure
c)
Torque moment Tinst [Nm] 10 20 40 80 150

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) h: base material thickness (h hmin)
b) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
c) This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.

10 / 2012 691
Hilti HIT-ICE
with HIS-(R)N

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given by
Hilti.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Hilti technical data
Anchor size M8 M10 M12 M16 M20
HIS-N [kN] 17,4 30,7 44,7 80,3 74,1
NRd,s
HIS-RN [kN] 13,9 21,9 31,6 58,8 69,2

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Hilti technical data
Anchor size M8 M10 M12 M16 M20
Embedment depth hef [mm] 90 110 125 170 205
0
N Rd,p Temperature range I [kN] 11,5 17,2 21,8 37,7 45,1

692 10 / 2012
Hilti HIT-ICE
with HIS-(R)N

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Hilti technical data
Anchor size M8 M10 M12 M16 M20
0
N Rd,c [kN] 20,5 27,7 33,6 53,3 70,6

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,1 a)
fB,p = (fck,cube/25N/mm) 1 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = 1

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

Influence of embedment depth on concrete cone resistance


fh,N = 1

10 / 2012 693
Hilti HIT-ICE
with HIS-(R)N

Influence of reinforcement
hef [mm] 80 90 100
fre,N = 0.5 + hef/200mm 1
a) a)
0.9 0.95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Hilti technical data
Anchor size M8 M10 M12 M16 M20
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
VRd,s
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

Design concrete pryout resistance VRd,cp = lower value a) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size M8 M10 M12 M16 M20
Non-cracked concrete
0
V Rd,c [kN] 12,4 19,6 28,2 40,2 46,2

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

694 10 / 2012
Hilti HIT-ICE
with HIS-(R)N

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


Anchor size M8 M10 M12 M16 M20
f hef = 1,38 1,21 1,04 1,22 1,45

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

10 / 2012 695
Hilti HIT-ICE
with HIS-(R)N

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Hilti technical data
Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 90 110 125 170 205
Base material thickness hmin= [mm] 120 150 170 230 270
Tensile NRd: single anchor, no edge effects

HIS-(R)N [kN] 11,5 17,2 21,8 37,7 45,1

Shear VRd: single anchor, no edge effects, without lever arm


HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Hilti technical data
Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 90 110 125 170 205
Base material thickness hmin= [mm] 120 150 170 230 270
Edge distance c = cmin= [mm] 40 45 55 65 90
Tensile NRd: single anchor, min. edge distance (c = cmin)

HIS-(R)N [kN] 6,1 8,8 11,3 19,1 25,5

Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm

HIS-(R)N [kN] 4,2 5,5 7,6 10,8 17,2

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


(load values are valid for single anchor)
Hilti technical data
Anchor size M8 M10 M12 M16 M20
Embedment depth hef = [mm] 90 110 125 170 205
Base material thickness hmin= [mm] 120 150 170 230 270
Spacing s = smin= [mm] 40 45 55 65 90
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)

HIS-(R)N [kN] 7,7 11,2 14,1 23,8 29,9

Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIS-N [kN] 10,4 18,4 26,0 39,3 36,7
HIS-RN [kN] 8,3 12,8 19,2 35,3 41,5

696 10 / 2012
Hilti HIT-ICE
with HIS-(R)N

10 / 2012 697
Hilti HIT-ICE
with rebar

Hilti HIT-ICE with rebar


Injection mortar system Benefits

Hilti - suitable for non-cracked concrete


HIT-ICE C 20/25 to C 50/60
296 ml cartridge - high loading capacity
- suitable for dry and water
saturated concrete
- high corrosion resistant
Statik mixer - odourless resin
- low installation temperature
(range -23 C 32 C)
rebar BSt 500 S

PROFIS
Small edge Variable
Anchor
Concrete distance embedment
design
and spacing depth
software

Basic loading data (for a single anchor)


All data in this section applies to For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Installation temperature range -18C to +32C

Embedment depth a) and base material thickness for the basic loading data. Mean
ultimate resistance, characteristic resistance, design resistance, recommended loads.
Hilti technical data
Anchor size 8 10 12 14 16 20 25
Typical embedment depth [mm] 80 90 110 125 125 170 210
Base material thickness [mm] 110 120 145 165 165 220 275
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.

Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500S
Hilti technical data
Anchor size 8 10 12 14 16 20 25
Tensile NRu,m BSt 500 S [kN] 20,2 28,3 40,0 51,8 63,6 84,6 105,8
Shear VRu,m BSt 500 S [kN] 14,7 23,1 32,6 44,1 57,8 90,3 141,8

698 10 / 2012
Hilti HIT-ICE
with rebar

Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Hilti technical data
Anchor size 8 10 12 14 16 20 25
Tensile NRk BSt 500 S [kN] 15,1 21,2 30,0 38,9 47,7 63,4 79,4
Shear VRk BSt 500 S [kN] 14,0 22,0 31,0 42,0 55,0 86,0 135,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Hilti technical data
Anchor size 8 10 12 14 16 20 25
Tensile NRd BSt 500 S [kN] 7,2 10,1 14,3 18,5 22,7 30,2 37,8
Shear VRd BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0

Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Hilti technical data
Anchor size 8 10 12 14 16 20 25
Tensile Nrec BSt 500 S [kN] 5,1 7,2 10,2 13,2 16,2 21,6 27,0
Shear Vrec BSt 500 S [kN] 6,7 10,5 14,8 20,0 26,2 41,0 64,3
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.

Service temperature range


Hilti HIT-ICE injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.

Maximum long term Maximum short term


Base material
Temperature range base material base material
temperature
temperature temperature
Temperature range I -40 C to +40 C +43 C +70 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.

10 / 2012 699
Hilti HIT-ICE
with rebar

Materials
Mechanical properties of rebar BSt 500S
Hilti technical data
Anchor size 8 10 12 14 16 20 25
Nominal
tensile BSt 500 S [N/mm] 550 550 550 550 550 550 550
strength fuk
Yield
[N/mm] 500 500 500 500 500 500 500
strength fyk
Stressed
cross- BSt 500 S [mm] 50,3 78,5 113,1 153,9 201,1 314,2 490,9
section As
Moment of
resistance BSt 500 S [mm] 50,3 98,2 169,6 269,4 402,1 785,4 1534
W

Material quality
Part Material
rebar Geometry and mechanical properties according to DIN 488-2:1986 or
BSt 500 S E DIN 488-2:2006

Setting
installation equipment
Anchor size 8 10 12 14 16 20 25
Rotary hammer TE 2 TE 16 TE 40 TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser

Setting instruction

Dry and water-saturated concrete, hammer drilling

700 10 / 2012
Hilti HIT-ICE
with rebar

a)

a) Note: Manual cleaning for element sizes d 16mm and embedment depth hef 10 d only!
Brush bore hole with required steel brush HIT-RB
For detailed information on installation see instruction for use given with the package of the product.

Curing time for general conditions


Hilti technical data
Temperature Curing time before anchor Working time in which anchor
of the base material can be fully loaded tcure can be inserted and adjusted tgel
32 C 35 min 1 min
21 C 45 min 2,5 min
16 C 1h 5 min
4 C 1h 15 min
- 7 C 6h 1h
- 18 C 24 h 1,5 h
- 23 C 36 h 1,5 h

10 / 2012 701
Hilti HIT-ICE
with rebar

Setting details
Hilti technical data
Anchor size 8 10 12 14 16 20 25
Nominal diameter of
d0 [mm] 12 14 16 18 20 25 32
drill bit
Effective anchorage
hef [mm] 80 90 110 125 125 170 210
and drill hole depth
Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness
a)
100 mm
Minimum spacing smin [mm] 40 50 60 70 80 100 125
Minimum edge
cmin [mm] 40 50 60 70 80 100 125
distance
Critical spacing for
scr,sp 2 ccr,sp
splitting failure

1,0 hef for h / hef 2,0

Critical edge distance


b) ccr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3
for splitting failure

2,26 hef for h / hef 1,3

Critical spacing for


scr,N 2 ccr,N
concrete cone failure
Critical edge distance
for concrete cone ccr,N 1.5 hef
c)
failure

For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) h: base material thickness (h hmin)
b) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.

Simplified design method


Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given by
Hilti.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two
anchors or more than one edge distance. The influencing factors must then be considered for each edge
distance and spacing. The calculated design loads are then on the save side: They will be lower than the
exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design
software PROFIS anchor)
702 10 / 2012
Hilti HIT-ICE
with rebar

The design method is based on the following simplification:


No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.

For more complex fastening applications please use the anchor design software PROFIS Anchor.

Tension loading

The design tensile resistance is the lower value of


- Steel resistance: NRd,s
- Combined pull-out and concrete cone resistance:
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0

fB f1,N f2,N f3,N fh,N fre,N


0
- Concrete cone resistance: NRd,c = N Rd,c

- Concrete splitting resistance (only non-cracked concrete):


NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
0

Basic design tensile resistance

Design steel resistance NRd,s


Hilti technical data
Anchor size 8 10 12 14 16 20 25
NRd,s BSt 500 S [kN] 20,0 30,7 44,3 60,7 79,3 123,6 192,9

Design combined pull-out and concrete cone resistance


NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
Hilti technical data
Anchor size 8 10 12 14 16 20 25
Typical embedment depth
80 90 110 125 125 170 210
hef,typ [mm]
0
N Rd,p Temperature range I [kN] 7,2 10,1 14,3 18,5 22,7 30,2 37,8

Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Hilti technical data
Anchor size 8 10 12 14 16 20 25
0
N Rd,c [kN] 17,2 20,5 27,7 33,6 33,6 53,3 73,2

Influencing factors

Influence of concrete strength on combined pull-out and concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
0,1 a)
fB,p = (fck,cube/25N/mm) 1 1,02 1,04 1,06 1,07 1,08 1,09
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

10 / 2012 703
Hilti HIT-ICE
with rebar

Influence of embedment depth on combined pull-out and concrete cone resistance


fh,p = 1

Influence of concrete strength on concrete cone resistance


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of embedment depth on concrete cone resistance


fh,N = 1

Influence of edge distance a)


c/ccr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
c/ccr,sp
f1,N = 0,7 + 0,3c/ccr,N
0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1
f1,sp = 0,7 + 0,3c/ccr,sp

f2,N = 0,5(1 + c/ccr,N)


0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.

Influence of anchor spacing a)


s/scr,N
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
s/scr,sp
f3,N = 0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.

Influence of reinforcement
hef [mm] 80 90 100
fre,N = 0.5 + hef/200mm 1
a) a)
0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.

704 10 / 2012
Hilti HIT-ICE
with rebar

Shear loading

The design shear resistance is the lower value of


- Steel resistance: VRd,s
- Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c
fB f f h f4 f hef fc
0
- Concrete edge resistance: VRd,c = V Rd,c

Basic design shear resistance

Design steel resistance VRd,s


Hilti technical data
Anchor size 8 10 12 14 16 20 25
VRd,s BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0

Design concrete pryout resistance VRd,cp = lower value a) of k NRd,p and k NRd,c
k=2
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance

Design concrete edge resistance VRd,c = V0Rd,c fB f f h f4 f hef fc


Anchor size 8 10 12 14 16 20 25
Non-cracked concrete
0
V Rd,c [kN] 5,9 8,6 11,6 15,0 18,7 27,0 39,2

Influencing factors

Influence of concrete strength


Concrete strength designation
C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60
(ENV 206)
1/2 a)
fB = (fck,cube/25N/mm) 1 1,1 1,22 1,34 1,41 1,48 1,55
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length

Influence of angle between load applied and the direction perpendicular to the free edge
Angle 0 10 20 30 40 50 60 70 80 90

1
f =
(cos V )2 + sin V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5

Influence of base material thickness


h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5
{h/(1,5 c)} 1
1/2
fh = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00

10 / 2012 705
Hilti HIT-ICE
with rebar

Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.

Influence of embedment depth


Anchor size 8 10 12 14 16 20 25
0,05 (hef / d)
1,68
f hef = 2,39 2,00 2,07 1,98 1,58 1,82 1,79

Influence of edge distance a)


c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.

Combined tension and shear loading


For combined tension and shear loading see section Anchor Design.

Precalculated values
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.

706 10 / 2012
Hilti HIT-ICE
with rebar

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Hilti technical data
Anchor size 8 10 12 14 16 20 25
Embedment depth hef,typ = [mm] 80 90 110 125 125 170 210
Base material thickness hmin= [mm] 110 120 142 161 165 220 274
Tensile NRd: single anchor, no edge effects

BSt 500 S [kN] 7,2 10,1 14,3 18,5 22,7 30,2 37,8

Shear VRd: single anchor, no edge effects, without lever arm

BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


Hilti technical data
Anchor size 8 10 12 14 16 20 25
Embedment depth hef,typ = [mm] 80 90 110 125 125 170 210
Base material thickness hmin= [mm] 110 120 142 161 165 220 274
Edge distance c = cmin= [mm] 40 50 60 70 80 100 125
Tensile NRd: single anchor, min. edge distance (c = cmin)

BSt 500 S [kN] 4,6 6,4 9,2 12,0 14,4 20,5 27,2

Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm

BSt 500 S [kN] 3,7 5,3 7,3 9,5 11,5 17,2 25,0

Design resistance: concrete C 20/25 fck,cube = 25 N/mm


(load values are valid for single anchor)
Hilti technical data
Anchor size 8 10 12 14 16 20 25
Embedment depth hef,typ = [mm] 80 90 110 125 125 170 210
Base material thickness hmin= [mm] 110 120 142 161 165 220 274
Spacing s = smin= [mm] 40 50 60 70 80 100 125
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)

BSt 500 S [kN] 5,2 7,2 10,1 13,0 15,5 21,5 27,6

Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm

BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 50,6 63,4

10 / 2012 707
Hilti HIT-HY 70

Hilti HIT-HY 70 injection mortar for masonry


Injection mortar system Benefits
Hilti HIT- - chemical injection fastening for all
HY 70 330 ml type of base materials:
foil pack
- hollow and solid
(also available
- clay bricks, sand-lime bricks,
as 500 ml
normal and light weight concrete
and 1400 ml blocks, aerated light weight
foil pack) concrete, natural stones
- two-component hybrid mortar
Mixer
- rapid curing
- versatile and convenient handling
HIT-V rod - flexible setting depth and
fastening thickness
HAS, HAS-E rod - small edge distance and anchor
spacing
HIT-IC internal - mortar filling control with HIT-SC
threaded sleeve sleeves
HIS-RN sleeve - suitable for overhead fastenings
- in-service temperatures:
HIT-SC short term: max.80C
composite
long term: max 50C
sleeve

Autoclaved PROFIS
Variable High
aerated Fire Corrosion Anchor
Concrete embedment Solid brick Hollow brick corrosion
concrete resistance resistance design
depth resistance
software

Approvals / certificates
Description Authority / Laboratory No. / date of issue
European Technical Approval DIBt, Berlin ETA-09/0265 / 2009-09-28
Allgemeine bauaufsichtliche
Zulassung DIBt, Berlin Z-21.3-1830 / 2011-12-01
(national German approval)
a)
Fiche technique SOCOTEC SOCOTEC, Paris YX 0047 06.2012
Fire test report MFPA, Leipzig PB III/B-07-157 / 2012-03-03
Assessment report (fire) warringtonfire WF 166402 / 2007-10-26

Basic loading data (for a single anchor)


All data in the table below applies to
Load values valid for holes drilled with TE rotary hammers in hammering mode
Correct anchor setting (see instruction for use, setting details)
Steel quality of fastening elements: see data below
Steel quality for screws for HIT-IG, HIT-IC and HIS-N: min. strength 5.8 / HIS-RN: A4-70
Threaded rods of appropriate size (diameter and length) and a minimum steel quality of 5.6 can be used
Base material temperature during installation and curing must be between -5C through +40C
708 10 / 2012
Hilti HIT-HY 70

(Exception: solid clay bricks (e.g. Mz12): +5C till 40C)

Recommended loads a) Frec for brick breakout and pull out in [kN]
Solid masonry: HIT-HY 70 with HIT-V, HAS, HAS-E and HIT-IC
HIT-V, HAS, HAS-E HIT-IC
Anchor size
Base Setting M6 M8 M10 M12 M8 M10 M12
material depth
[mm]
Solid clay brick
Mz12/2,0 Nrec [kN] - 1,0 1,7 1,7 1,7 1,7 1,7
DIN 105/
EN 771-1
fb 12 N/mm
b) Vrec [kN] - 1,0 1,7 1,7 1,7 1,7 1,7
80
c) c) c) c) c) c)
Nrec [kN] - 3,0 3,0 3,0 3,0 3,0 3,0
Germany,
Austria, c) c) c) c) c) c)
Vrec [kN] - 3,0 3,0 3,0 3,0 3,0 3,0
Switzerland
Solid sand-
lime brick Nrec [kN] - 1,0 1,7 1,7 1,7 1,7 1,7
KS 12/2,0
DIN 106/
EN 771-2 Vrec [kN] - 1,0 1,7 1,7 1,7 1,7 1,7
fb 12 N/mm
b)

80
d) d) d) d) d) d)
Nrec [kN] - 3,0 3,0 3,0 3,0 3,0 3,0

Germany,
Austria, Vrec [kN] - 3,0
d)
3,0
d)
3,0
d)
3,0
d)
3,0
d)
3,0
d)

Switzerland
a) Recommended load values for German base materials are based on national regulations.
b) fb = brick strength
c) Values only valid for Mz (DIN 105) with brick strength 29 N/mm, density 2,0 kg/dm, minimum brick size NF
(24,0cm x 11,5cm x 7,1cm), not covered by national German approval Z-21.3-1830 / 2009-01-20
d) Values only valid for KS (DIN 106) with brick strength 23 N/mm, density 2,0 kg/dm, minimum brick size NF
(24,0cm x 11,5cm x 7,1cm), not covered by national German approval Z-21.3-1830 / 2009-01-20

10 / 2012 709
Hilti HIT-HY 70

Recommended loads a) Frec for brick breakout and pull out in [kN]
Solid masonry: HIT-HY 70 with HIT-V, HAS, HAS-E and HIT-IC
HIT-V, HAS, HAS-E HIT-IC
Anchor size
Base Setting M6 M8 M10 M12 M8 M10 M12
material depth
[mm]
Aerated
concrete PPW
2-0,4
Nrec [kN] - 0,5 0,6 0,6 0,6 0,6 0,6
DIN 4165/
EN 771-4
fb b) 2 N/mm 80

Vrec [kN] - 0,1 0,1 0,2 0,2 0,4 0,4


Germany,
Austria,
Switzerland
Lightweight
concrete acc. Nrec [kN] - 1,0 1,0 1,5 1,5 1,5 1,5
TGL
(haufwerks- 80
poriger
Leichtbeton), Vrec [kN] - 1,0 1,0 1,5 1,5 1,5 1,5
Germany
a) Recommended load values for German base materials are based on national regulations.
b) fb = brick strength

Basic loading data (for a single anchor)


All data in the table below applies to
Load values valid for holes drilled with TE rotary hammers in sensitive hammering mode
Correct anchor setting (see instruction for use, setting details)
Steel quality of fastening elements: see data above;
Steel quality for screws for HIT-IG: min. strength 5.8
Threaded rods of appropriate size (diameter and length) and a minimum steel quality of 5.6 can be used

710 10 / 2012
Hilti HIT-HY 70

Recommended loads a) Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-V, HAS, HAS-E and HIT-IC
HIT-V, HAS, HAS-E HIT-IC
Anchor size M6 M8 M10 M12 M8 M10 M12

Base Setting
HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC
depth
material 12x 16x 16x 18x 16x 18x 22x 22x
[mm]
Nrec [kN] 0,3 0,4 0,4 0,8 - - - -
50
HlzB 6 Vrec [kN] 0,3 0,4 0,4 0,4 - - - -
DIN 105/ Nrec [kN] - 0,8 0,8 0,8 0,8 0,8 0,8 0,8
EN 771-1 80
Vrec [kN] - 0,8 0,8 0,8 0,8 0,8 0,8 0,8
fb b) 6 N/mm
Nrec [kN] - 0,8 0,8 0,8 - - - -
100
Vrec [kN] - 0,8 0,8 0,8 - - - -

Germany, Nrec [kN] - 0,84 0,84 0,8 - - - -


130
Austria, Vrec [kN] - 0,8 0,8 0,8 - - - -
Switzerland
Nrec [kN] - 0,91 0,91 0,8 - - - -
160
Vrec [kN] - 0,8 0,8 0,8 - - - -
Nrec [kN] 0,6 0,8 0,8 0,8 - - - -
50
Hlz 12 Vrec [kN] 0,6 0,8 0,8 0,8 - - - -
DIN 105/ Nrec [kN] - 1,0 1,0 1,0 1,0 1,0 1,0 1,0
EN 771-1 80
fb b) 12 N/mm Vrec [kN] - 1,0 1,0 1,0 1,0 1,0 1,0 1,0
Nrec [kN] - 1,54 1,54 1,54 - - - -
100
Vrec [kN] - 1,4 1,4 1,4 - - - -
Nrec [kN] - 1,68 1,68 1,54 - - - -
Germany, 130
Austria, Vrec [kN] - 1,4 1,4 1,4 - - - -
Switzerland
Nrec [kN] - 1,82 1,82 1,54 - - - -
160
Vrec [kN] - 1,4 1,4 1,4 - - - -
a) Recommended load values for German base materials are based on national regulations.
b) fb = brick strength

10 / 2012 711
Hilti HIT-HY 70

Recommended loads a) Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-V, HAS, HAS-E and HIT-IC
HIT-V, HAS, HAS-E HIT-IC
Anchor size M6 M8 M10 M12 M8 M10 M12
Settin
Base g HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC
material depth 12x 16x 16x 18x 16x 18x 22x 22x
[mm]
Nrec [kN] 0,5 0,7 0,7 0,7 - - - -
50
Vrec [kN] 0,5 0,7 0,7 0,7 - - - -
KSL 12
DIN 106/ Nrec [kN] - 1,4 1,4 1,4 1,4 1,4 1,0 1,0
EN 771-2 80
Vrec [kN] - 1,4 1,4 1,4 1,4 1,4 1,0 1,0
fb b) 12 N/mm
Nrec [kN] - 1,4 1,4 1,4 - - - -
100
Vrec [kN] - 1,4 1,4 1,4 - - - -

Germany, Nrec [kN] - 1,44 1,44 1,4 - - - -


130
Austria, Vrec [kN] - 1,4 1,4 1,4 - - - -
Switzerland
Nrec [kN] - 1,56 1,56 1,4 - - - -
160
Vrec [kN] - 1,4 1,4 1,4 - - - -
a) Recommended load values for German base materials are based on national regulations.
b) fb = brick strength

712 10 / 2012
Hilti HIT-HY 70

Recommended loads a) Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-V, HAS, HAS-E and HIT-IC
HIT-V, HAS, HAS-E HIT-IC
Anchor size M6 M8 M10 M12 M8 M10 M12
Settin
Base g HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC
material depth 12x 16x 16x 18x 16x 18x 22x 22x
[mm]
Nrec [kN] 0,3 0,5 0,5 0,5 - - - -
50
Vrec [kN] 0,3 0,5 0,5 0,5 - - - -
Hbl 2
DIN 18 151/ Nrec [kN] - 0,5 0,5 0,5 0,5 0,5 0,5 0,5
EN 771-3 80
Vrec [kN] - 0,5 0,5 0,5 0,5 0,5 0,5 0,5
fb b) 2 N/mm
Nrec [kN] - 0,7 0,7 0,7 - - - -
100
Vrec [kN] - 0.6 0.6 0.6 - - - -

Germany, Nrec [kN] - 0.72 0.72 0,7 - - - -


130
Austria, Vrec [kN] - 0,6 0,6 0,6 - - - -
Switzerland
Nrec [kN] - 0,78 0,78 0,7 - - - -
160
Vrec [kN] - 0,6 0,6 0,6 - - - -
Hbl 4
DIN 18 151/ Nrec [kN] 0,4 0,6 0,6 0,6 - - - -
EN 771-3 50
fb b) 4 N/mm Vrec [kN] 0,4 0,6 0,6 0,6 - - - -

Nrec [kN] - 0,8 0,8 0,8 0,8 0,8 0,8 0,8


Germany, 80
Austria,
Vrec [kN] - 0,8 0,8 0,8 0,8 0,8 0,8 0,8
Switzerland
Hbn 4
DIN 18 153/ Nrec [kN] 0,4 0,6 0,6 0,6 - - - -
EN 771-3 50
fb b) 4 N/mm Vrec [kN] 0,4 0,6 0,6 0,6 - - - -

Nrec [kN] - 0,8 0,8 0,8 0,8 0,8 0,8 0,8


Germany, 80
Austria,
Switzerland Vrec [kN] - 0,8 0,8 0,8 0,8 0,8 0,8 0,8

a) Recommended load values for German base materials are based on national regulations.
b) fb = brick strength

10 / 2012 713
Hilti HIT-HY 70

Recommended loads a) Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-V, HAS, HAS-E and HIT-IC
HIT-V, HAS, HAS-E HIT-IC
Anchor size M6 M8 M10 M12 M8 M10 M12
Settin
Base g HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC
material depth 12x 16x 16x 18x 16x 18x 22x 22x
[mm]

Brique creuse Nrec [kN] - 0,5 0,5 0,5 0,5 0,5 0,5 0,5
80
C40 Vrec [kN] - 1,0 1,0 1,0 1,0 1,0 1,0 1,0
NF-P 13-301/
EN 771-1 Nrec [kN] - 0,5 0,5 0,5 - - - -
100
fb b) 4 N/mm Vrec [kN] - 1,0 1,0 1,0 - - - -
Nrec [kN] - 0,5 0,5 0,5 - - - -
130
Vrec [kN] - 1,0 1,0 1,0 - - - -
France Nrec [kN] - 0,5 0,5 0,5 - - - -
160
Vrec [kN] - 1,0 1,0 1,0 - - - -

Parpaing creux Nrec [kN] - 0,7 0,7 0,7 0,7 0,7 0,7 0,7
80
B40 Vrec [kN] - 1,5 1,5 1,5 1,5 1,5 1,5 1,5
NF-P 14-301/
EN 771-3 Nrec [kN] - 0,7 0,7 0,7 - - - -
fb b) 4 N/mm 100
Vrec [kN] - 1,5 1,5 1,5 - - - -
Nrec [kN] - 0,7 1,2 1,2 - - - -
130
Vrec [kN] - 1,5 1,7 1,7 - - - -

France Nrec [kN] - 0,7 1,2 1,2 - - - -


160
Vrec [kN] - 1,5 1,7 1,7 - - - -
a) Recommended load values for French base materials are based on national regulations.
b) fb = brick strength

714 10 / 2012
Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-
HY 70 with HIT-SC and HIT-V, HAS, HAS-E and HIT-IC
Values in brackets: mean ultimate loads Fu,m [kN]:
HIT-V, HAS, HAS-E HIT-IC
Anchor size M6 M8 M10 M12 M8 M10 M12
Settin
Base g HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC
material depth 12x 16x 16x 18x 16x 18x 22x 22x
[mm]
Nrec [kN] 0,9 (4,2) 1,1 1,1 (4,9) 1,25 - - - -
50
Mattone Vrec [kN] 1,2 (5,8) 1,2 1,2 1,2 - - - -
Alveolater 50 Nrec [kN] 1,1 (5,0) 1,5 1,5 1,7 1,5 (7,0) 1,7 1,7 1,7
80
EN 771-1 Vrec [kN] 1,2 (5,3) 1,2 1,2 1,2 1,2 1,2 2,0 2,0
fb 16 N/mm
b)
Nrec [kN] - 1,5 1,5 1,7 - - - -
100
Vrec [kN] - 1,2 1,2 1,2 - - - -
Nrec [kN] - 2,3 (10,4) 2,3 2,8 - - - -
130
Vrec [kN] - 1,2 1,2 1,2 - - - -
Italy Nrec [kN] - 2,3 2,3 2,8 - - - -
160
Vrec [kN] - 1,2 1,2 1,2 - - - -
Nrec 0,65
0,65 0,65 0,65 - - - -
50 [kN] (2,9)
Vrec [kN] 1,3 (5,7) 1,3 1,3 (6,6) 1,3 - -
Nrec
1,0 (5,0) 1,0 1,0 (6,8) 1,0 1,0 1,0 1,0 1,0 (4,5)
Doppio uni 80 [kN]
EN 771-1 Vrec [kN] 1,3 (6,1) 1,9 1,9 (8,5) 1,9 1,9 1,9 2,0 2,0
fb 27 N/mm
b) N rec
- 1,0 1,0 1,0 - - - -
100 [kN]
Vrec [kN] - 1,9 1,9 1,9 - - - -
Nrec 2,0
- 2,0 2,0 - - - -
Italy 130 [kN] (12,1)
Vrec [kN] - 1,9 1,9 1,9 - - - -
Nrec
- 2,0 2,0 2,0 - - - -
160 [kN]
Vrec [kN] - 1,9 1,9 1,9 - - - -
Nrec [kN] 0,6 (2,7) 0,7 (3,3) 0,7 1,0 0,7 1,0 1,0 1,0 (5,2)
Foratino 4 Fori 80
Vrec [kN] 0,9 0,9 0,9 0,9 0,9 0,9 1,0 1,0
EN 771-1 N [kN] - 0,7 0,7 1,0 - - - -
rec
fb 7 N/mm
b) 100
Vrec [kN] - 0,9 0,9 0,9 - - - -
Nrec [kN] - 1,5 (6,7) 1,5 1,9 - - - -
130
Vrec [kN] - 0,9 0,9 0,9 - - - -
Italy N rec [kN] - 1,5 (7,3) 1,5 1,5 - - - -
160
Vrec [kN] - 0,9 0,9 1,0 - - - -
a) Recommended load values with consideration of a global safety factor global = 3,0: Frec = FRk / global
b) fb = brick strength

10 / 2012 715
Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-
HY 70 with HIT-SC and HIT-V, HAS, HAS-E and HIT-IC
Values in brackets: mean ultimate loads Fu,m [kN]:
HIT-V, HAS, HAS-E HIT-IC
Anchor size M6 M8 M10 M12 M8 M10 M12
Settin
Base g HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC
material depth 12x 16x 16x 18x 16x 18x 22x 22x
[mm]
Nrec 0,35 0,45
Mattone rosso 0,45 0,45 - - - -
[kN] (1,7) (2,0)
EN 771-1 50
fb 26 N/mm
b) Vrec [kN] - - - - - -
Nrec
0,5 (2,9) 0,5 (2,1) 0,5 (3,3) 0,6 0,5 0,6 0,6 (4,2) 0,6
[kN]
80
Italy Vrec [kN] - - - - - - - -

Blocchi cem 2 Nrec [kN] 1,0 (5,8) 1,25 (6,6) 1,25 1,25
Fori 50
EN 771-3 Vrec [kN] 1,5 (7,2) 1,5 1,5 1,5
fb 8 N/mm
b)

Nrec [kN] 1,0 (4,6) 1,25 (6,8) 1,25 1,25 1,25 1,25 1,25 (5,6) 1,25
80
Italy Vrec [kN] 1,5 (7,1) 2,0 2,0 2,0 2,0 2,0 2,0 2,0
a) Recommended load values with consideration of a global safety factor global = 3,0: Frec = FRk / global
b) fb = brick strength

Recommended loads a) Frec for brick breakout and pull out in [kN]
Solid masonry: HIT-HY 70 with HIT-V, HAS, HAS-E and HIT-IC
c)
HIT-V, HAS, HAS-E or Rebar
Anchor size
Settin Rod M8 Rod M10 Rod M12 Rod M14 Rod M16
Base g or or or or or
d) d) d) d) d)
material depth Rebar 8 Rebar 10 Rebar 12 Rebar 14 Rebar 16
[mm]
Nrec [kN] 0,9 - - - -
80
Vrec [kN] 0,9 - - - -
Volcanic rock Nrec [kN] - 1,2 - - -
(Tufo) 100
EN 771-3 Vrec [kN] - 1,2 - - -
fb b) 4,3 N/mm Nrec [kN] - - 1,5 - -
120
Vrec [kN] - - 1,5 - -

Italy Nrec [kN] - - - 1,8 -


140
Vrec [kN] - - - 1,8 -
Nrec [kN] - - - - 2,1
160
Vrec [kN] - - - - 2,1
a) Recommended load values with consideration of a global safety factor global = 3,0: Frec = FRk / global
b) fb = brick strength
c) Minimum base material thickness h = setting depth + 50mm.
d) Drill bit diameters for rebars BSt 500S:
8: d0=12mm; 10: d0=14mm; 12: d0=16mm; 14: d0=18mm; 16: d0=20mm;

716 10 / 2012
Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-
HY 70 with HIT-SC and HIT-V, HAS, HAS-E and HIT-IC
Values in brackets: mean ultimate loads Fu,m [kN]:
HIT-V, HAS, HAS-E HIT-IC
Anchor size M6 M8 M10 M12 M8 M10 M12
Settin
Base g HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC
material depth 12x 16x 16x 18x 16x 18x 22x 22x
[mm]
Nrec 0,5 0,5 0,5
Hueco doble 0,5 - - - -
[kN] (2,6) (2,0) (2,4)
EN 771-1 50
fb 4 N/mm
b)
0,9
Vrec [kN] 0,9 0,9 0,9 - - - -
(4,2)
Nrec 0,7 0,9 0,9 0,9 1,1
1,1 1,1 1,1
[kN] (3,1) (3,8) (4,0) (4,0) (6,3)
80
Spain 1,0 1,0
Vrec [kN] 1,0 1,0 1,0 1,0 1,7 1,7
(4,8) (4,5)
Nrec 0,5
0,7 0,7 0,7 - - - -
Termoarcilla [kN] (3,1)
EN 771-1 50
1,2
fb 22 N/mm
b)
Vrec [kN] 1,2 1,2 1,2 - -
(5,5)
Nrec 0,5 1,1 1,3
1,1 1,3 1,1 1,3 1,3
[kN] (2,4) (5,2) (5,8)
80
Spain 1,2
Vrec [kN] 1,2 1,2 1,2 1,2 1,2 2,0 2,0
(5,6)
Nrec 0,8 0,8
Ladrillo cara 0,8 0,8
[kN] (4,5) (3,6)
vista 50
EN 771-1 1,5 1,6
Vrec [kN] 1,6 1,6
fb 42 N/mm (6,9) (8,6)
b)

Nrec 1,9 2,3


0,8 1,9 1,9 2,3 2,3 2,3
[kN] (8,5) (10,4)
80
Spain 2,0
Vrec [kN] 1,5 2,0 2,0 2,0 2,0 2,0 2,0
(12,4)

Clinker medi- Nrec 0,7 0,7


0,7 0,7 - - - -
terraneo EN [kN] (3,3) (3,1)
50
771-1 1,5 1,6
Vrec [kN] 1,6 1,6 - - - -
fb 78 N/mm
b)
(6,4) (7,8)
Nrec 1,8 1,8 2,1
0,7 1,8 2,1 2,1 2,1
[kN] (8,0) (8,3) (9,7)
80
1,4 2,0 2,0
Spain Vrec [kN] 2,0 2,0 2,0 2,0 2,0
(6,4) (9,5) (14,4)
a) Recommended load values with consideration of a global safety factor global = 3,0: Frec = FRk / global
b) fb = brick strength

10 / 2012 717
Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-V, HAS, HAS-E and HIT-IC
HIT-V, HAS, HAS-E HIT-IC
Anchor size M6 M8 M10 M12 M8 M10 M12
Settin
Base g HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC
material depth 12x 16x 16x 18x 16x 18x 22x 22x
[mm]

Concrete Nrec
Block 0,3 0,8 1,1 2,0 - - - -
[kN]
EN 771-3 50
fb 7,0 N/mm
b)

L x H x B [mm] Vrec [kN] 1,0 1,6 2,0 2,0 - - - -


440 x 215 x 215

Nrec
0,3 0,8 1,1 2,0 - - - -
[kN]
(Shell thickness 80
48 mm)
Great Britain Vrec [kN] 1,0 1,6 2,0 2,0 - - - -

Nrec
Concrete 0,4 0,6 0,7 1,5 - - - -
[kN]
Block 50
EN 771-3
fb 7 N/mm
b)
Vrec [kN] 0,9 1,7 1,7 1,7 - - - -
L x H x B [mm]
440 x 215 x 138
Nrec
0,4 0,6 0,7 1,5 - - - -
[kN]
(Shell thickness
48 mm) 80
Great Britain Vrec [kN] 0,9 1,7 1,7 1,7 - - - -

Concrete
Block
EN 771-3 Nrec
0,5 0,8 0,9 0,9 - - - -
fb 7 N/mm
b) [kN]
L x H x B [mm]
440 x 215 x 112
50

(Shell
thickness 48 Vrec [kN] 1,1 1,3 1,3 1,3 - - - -
mm)
Great Britain

a) Recommended load values with consideration of a global safety factor global = 3,0: Frec = FRk / global
b) fb = brick strength

718 10 / 2012
Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-V, HAS, HAS-E and HIT-IC
HIT-V, HAS, HAS-E HIT-IC
Anchor size M6 M8 M10 M12 M8 M10 M12
Settin
Base g HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC
material depth 12x 16x 16x 18x 16x 18x 22x 22x
[mm]

Dense
Concrete
EN 771-3 Nrec [kN] 1,5 2,5 2,5 2,5 - - - -
fb 14 N/mm
b)

L x H x B [mm]
440 x 215 x 100 50

Vrec [kN] 1,3 2,5 2,5 2,5 - - - -


Great Britain

Dense Nrec [kN] 1,5 2,5 2,5 2,5


Concrete
EN 771-3 50
fb 14 N/mm
b)
Vrec [kN] 1,3 2,5 2,5 2,5
L x H x B [mm]
440 x 215 x 140
Nrec [kN] 1,5 3,0 3,0 3,0 3,0 3,0 3,0 4,0
80
Great Britain Vrec [kN] 1,3 2,5 2,5 2,5 2,5 2,5 3,0 3,0

Thermalite/ Nrec [kN] 0,7 0,8 0,8 0,8 - - - -


Celcon
50
EN 771-3
fb 6 N/mm
b) Vrec [kN] 0,5 0,6 0,6 0,6 - - -
L x H x B [mm]
440 x 100 x 215
Nrec [kN] 1,3 1,5 1,5 1,7 1,5 1,7 1,7 1,7
80
Great Britain Vrec [kN] 0,9 1,0 1,0 1,0 1,0 1,0 1,2 1,2

Nostell Red Nrec [kN] 1,0 2,0 2,0 2,0


Multi
50
EN 771-3
fb 70 N/mm
b)
Vrec [kN] 1,5 3,0 3,0 3,0
L x H x B [mm]
215 x 102 x 65
Nrec [kN] 1,0 3,0 3,0 3,0 3,0 3,5 3,5 3,5
80
Great Britain Vrec [kN] 1,5 3,0 3,0 3,0 3,0 3,0 3,0 3,0

a) Recommended load values with consideration of a global safety factor global = 3,0: Frec = FRk / global
b) fb = brick strength

10 / 2012 719
Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-V, HAS, HAS-E and HIT-IC
HIT-V, HAS, HAS-E HIT-IC
Anchor size M6 M8 M10 M12 M8 M10 M12
Settin
Base g HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC
material depth 12x 16x 16x 18x 16x 18x 22x 22x
[mm]
London yellow Nrec
Multi Stock 1,0 1,3 1,3 1,7 - - - -
[kN]
EN 771-3 50
fb 16 N/mm
b)
Vrec [kN] 1,4 1,9 1,9 1,9 - - - -
L x H x B [mm]
215 x 100 x 65
Nrec
2,0 3,0 3,0 3,0 3,0 3,0 3,0 4,0
[kN]
80
Vrec [kN] 1,4 2,5 2,5 2,5 2,5 2,5 3,0 3,0
Great Britain
a) Recommended load values with consideration of a global safety factor global = 3,0: Frec = FRk / global
b) fb = brick strength

Recommended loads a) Frec for brick breakout and/or pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-V, HAS, HAS-E and HIT-IC
HIT-V, HAS, HAS-E HIT-IC
Anchor size
Base Setting Base M6 M8 M10 M12 M8 M10 M12
material depth material
[mm]
Dense
Concrete
EN 771-3 Nrec [kN] - 2,5 2,5 2,5 - - -
fb 14 N/mm
b)

L x H x B [mm] 80
440 x 215 x 100

Vrec [kN] - 2,5 2,5 3,0 - - -

Great Britain
Dense
Concrete
c) c) c)
EN 771-3 Nrec [kN] - 3,5 4,0 4,5 - - -
fb 14 N/mm
b)

L x H x B [mm]
440 x 215 x 140 80

Vrec [kN] - 2,5 2,5 3,0 - -

Great Britain
a) Recommended load values with consideration of a global safety factor global = 3,0: Frec = FRk / global
b) fb brick strength
c) The minimum value of brick break out and/or pull out given in the table and of pull out of one brick is decisive.

720 10 / 2012
Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-V, HAS, HAS-E and HIT-IC
HIT-V, HAS, HAS-E HIT-IC
Anchor size M6 M8 M10 M12 M8 M10 M12
Settin
Base g HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC
material depth 12x 16x 16x 18x 16x 18x 22x 22x
[mm]

Nrec
Fire light brick 0,5 0,5 0,5 0,8 - - - -
[kN]
Scoria Blend 50
fb 16 N/mm
b)

L x H x B [mm] Vrec [kN] 1,0 1,5 1,5 1,5 - -


230 x 110 x 119
Nrec
1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8
[kN]
(Shell thickness 80
19 mm) Vrec [kN] 1,25 2,0 2,0 2,0 2,0 2,0 2,0 2,0
Australia

Nrec
0,6 0,6 0,6 0,6 - - - -
Hollow Block [kN]
fb 15 N/mm
b) 50
L x H x B [mm] Vrec [kN] 1,0 1,5 1,5 1,5 - - - -
390 x 190 x 190

Nrec
0,6 0,9 0,9 1,7 0,9 1,7 1,7 1,7
[kN]
(Shell thickness 80
30 mm)
Australia Vrec [kN] 1,25 2,0 2,0 2,0 2,0 2,0 2,0 2,0

Nrec
Clay common 1,5 1,5 1,5 1,5 - - - -
[kN]
(Standard) 50
fb 84 N/mm
b)

L x H x B [mm] Vrec [kN] 2,0 2,0 2,0 2,0 - - - -


230 x 110 x 76
Nrec
2,0 3,0 3,0 3,0 3,0 4,0 4,0 4,0
[kN]
(Shell thickness 80
20 mm)
Vrec [kN] 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0
Australia
a) Recommended load values with consideration of a global safety factor global = 3,0: Frec = FRk / global
b) fb = brick strength

10 / 2012 721
Hilti HIT-HY 70

Recommended loads a) Frec for brick breakout and pull out in [kN]
Solid masonry: HIT-HY 70 with HIT-V, HAS, HAS-E and HIT-IC
HIT-V, HAS, HAS-E HIT-IC
Anchor size
Base Setting M6 M8 M10 M12 M8 M10 M12
material depth
[mm]

Clay common
(Dry pressed) Nrec [kN] - 2,5 3,0 4,0 2,5 3,0 4,0
fb 25 N/mm
b)

L x H x B [mm]
80
230 x 110 x 76

Vrec [kN] - 2,0 2,0 2,0 2,0 2,0 2,0


Australia

Calduran
Solid sand-lime c) c) c) c) c)
Nrec [kN] - - 2,5 3,0 3,0 3,0 4,0
brick
fb 22 N/mm
b)

L x H x B [mm] 80
437x198x100

Vrec [kN] - - 3,0 4,0 3,0 3,0 4,0


Netherlands

Calduran
Solid sand-lime c) c) c) c) c)
Nrec [kN] - - 2,5 3,0 3,0 3,0 4,0
brick
fb 22 N/mm
b)

L x H x B [mm] 80
437x298x215

Vrec [kN] - - 3,0 4,0 3,0 3,0 4,0


Netherlands

a) Recommended load values with consideration of a global safety factor global = 3,0: Frec = FRk / global
b) fb = brick strength
c) The minimum value of brick break out and/or pull out given in the table and of pull out of one brick is decisive.

722 10 / 2012
Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-V, HAS, HAS-E and HIT-IC
HIT-V, HAS, HAS-E HIT-IC
Anchor size M6 M8 M10 M12 M8 M10 M12
Settin
Base g HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC
material depth 12x 16x 16x 18x 16x 18x 22x 22x
[mm]

Wienerberger Nrec [kN] 1,0 1,25 1,25 1,25 - - - -


Powerbrick 50
fb 41 N/mm
b)

L x H x B [mm] Vrec [kN] 1,5 2,0 2,0 2,0 - - - -


285x135x135
Nrec [kN] 1,5 1,75 1,75 2,0 1,75 2,0 2,0 2,0
80
Belgium Vrec [kN] 1,5 3,0 3,0 3,0 3,0 3,0 4,0 4,0

Wienerberger Nrec [kN] 0,5 0,75 0,75 1,0 - - - -


Thermobrick
50
fb 21 N/mm
b)

L x H x B [mm] Vrec [kN] 1,0 1,25 1,25 1,25 - - - -


285x135x138
Nrec [kN] 1,5 1,75 1,75 1,75 1,75 1,75 1,75 1,75
80
Belgium Vrec [kN] 1,5 2,0 2,0 2,0 2,0 2,0 2,5 2,5

Concrete
hollow brick
fb 6 N/mm
b)
Nrec [kN] 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5
L x H x B [mm]
600x500x92
50

Vrec [kN] 0,5 0,75 0,75 0,75 0,75 0,75 1,0 1,0
(Shell thickness
15 mm) Finland

Leca typ 3
Nrec [kN] - 2,0 2,0 2,0 2,0 2,0 2,0 2,0
EN 771-3
fb 3,0 N/mm
80

Vrec [kN] - 1,2 1,2 1,2 1,2 1,2 2,0 2,0


Sweden

a) Recommended load values with consideration of a global safety factor global = 3,0: Frec = FRk / global
b) fb = brick strength

10 / 2012 723
Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-V, HAS, HAS-E and HIT-IC
Values in brackets: mean ultimate loads Fu,m [kN]:
HIT-V, HAS, HAS-E HIT-IC
Anchor size M6 M8 M10 M12 M8 M10 M12
Settin
Base g HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC
material depth 12x 16x 16x 18x 16x 18x 22x 22x
[mm]
Concrete 1,25 1,5 1,5 2,0
block Nrec [kN] - - - -
(8,1)
fb 23 N/mm
b)
50
L x H x B [mm] 1,25 1,5 1,5 1,5
Vrec [kN] - - - -
390 x 190 x 120 (6,7) (11,4)
1,25 1,5 1,5 2,0 1,5 2,0 2,0 2,0
Nrec [kN]
(9,0) (10,3) (9,2) (12,1)
(Shell thickness 80
25 mm) 1,25 1,5 1,5 1,5 1,5 1,5 2,0 2,0
Vrec [kN]
Japan (7,1) (11,4) (15,9)
Spancrete
(Hollow Core
Slab) 1,25 2,0 2,0 2,5 2,5 2,5 2,5
Nrec [kN] -
fb 83 N/mm
b) (8,5) (15,0) (13,9) (19,3)
L x H x B [mm]
1000 x1000 x125 50

1,25 2,5 2,5 2,5 2,5 2,5 3,0


(Shell thickness Vrec [kN] -
(7,0) (12,0) (21,3) (28,1)
27,5 mm)
Japan

Aereted
concrete block
fb 6 N/mm
b)

L x H x B [mm]
1900 x 600 x 100 1,25 1,75 1,75 2,0
Nrec [kN] - - - -
(8,1) (8,6)
Special application:
through fastening
HIT-SC HIT-SC
x85 x50
130

0,75 1,00 1,00 1,00


Vrec [kN] - - - -
(6,3) (9,2)
100

Japan
a) Recommended load values with consideration of a global safety factor global = 3,0: Frec = FRk / global
b) fb = brick strength

724 10 / 2012
Hilti HIT-HY 70

Recommended loads a) Frec for brick breakout and pull out in [kN]
Solid masonry: HIT-HY 70 with HIT-V, HAS, HAS-E and HIT-IC
Values in brackets: mean ultimate loads Fu,m [kN]:
HIT-V, HAS, HAS-E HIT-IC
Anchor size
Base Setting M6 M8 M10 M12 M8 M10 M12
material depth
[mm]

Aereted 0,75
Nrec [kN] - - - 0,75 - -
concrete (4,0)
50
block 1,0
fb 6 N/mm
b)
Vrec [kN] - - - 1,0 - -
(8,6)
LxHxB
[mm] 1,5 1,75 1,75
1900 x 600 x 100 Nrec [kN] - - 1,75 -
(7,3) (7,4) (8,0)
80
0,75 1,0 1,0 1,0
Japan Vrec [kN] - - -
(4,2) (4,7) (4,6) (5,8)
a) Recommended load values with consideration of a global safety factor global = 3,0: Frec = FRk / global
b) fb brick strength

Design
Influence of joints:

If the joints of the masonry are not visible the recommended load Nrec has to be reduced with the factor j = 0.75.

If the joints of the masonry are visible (e.g. unplastered wall) following has to be taken into account:
The recommended load Nrec may be used only, if the wall is designed such that the joints are to be
filled with mortar.
If the wall is designed such that the joints are not to be filled with mortar then the recommended load
Nrec may be used only, if the minimum edge distance cmin to the vertical joints is observed. If this
minimum edge distance cmin can not be observed then the recommended load Nrec has to be reduced
with the factor j = 0.75.

The decisive resistance to tension loads is the lower value of Nrec (brick breakout, pull out) and Nmax,pb (pull
out of one brick).

Pull out of one brick:

The allowable load of an anchor or a group of anchors in case of pull out of one brick, Nmax,pb [kN], is given in the
following tables:

Clay bricks: All other brick types:


Nmax,pb brick breadth bbrick [mm] Nmax,pb brick breadth bbrick [mm]
[kN] 80 120 200 240 300 360 [kN] 80 120 200 240 300 360
brick 240 1,1 1,6 2,7 3,3 4,1 4,9 brick 240 0,8 1,2 2,1 2,5 3,1 3,7
length length
300 1,4 2,1 3,4 4,1 5,1 6,2 300 1,0 1,5 2,6 3,1 3,9 4,6
lbrick lbrick
[mm] 500 2,3 3,4 5,7 6,9 8,6 10,3 [mm] 500 1,7 2,6 4,3 5,1 6,4 7,7

10 / 2012 725
Hilti HIT-HY 70

Nmax,pb = resistance for pull out of one brick


lbrick = length of the brick
bbrick = breadth of the brick

Nmax,pb
lbrick bbrick

For all applications outside of the above mentioned base materials and / or setting conditions
site tests have to be made for the determination of load values.
Due to the wide variety of natural stones site tests have to be made for determine of load values.

Materials
Material quality HAS
Part Material
Threaded rod Strength class 5.8, A5 > 8% ductile
HAS-(E) steel galvanized 5 m
Threaded rod Stainless steel grade A4, A5 > 8% ductile strength class 70, 1.4401;
HAS-(E)R 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Washer Steel galvanized,
ISO 7089 Stainless steel, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 8,
steel galvanized 5 m
Nut Strength class 70, stainless steel grade A4,
EN ISO 4032 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, high corrosion resistant steel,
1.4529; 1.4565

Material quality HIT-A


Part Material
HIT-AC rod Carbon steel strength 5.8; galvanized to min. 5 m
HIT-ACR rod Stainless steel, grade A4-70; 1.4401; 1.4404; 1.4571
HIT-AN rod Carbon steel strength 3.6; galvanized to min. 5 m

Material quality sleeves


Part Material
HIT-IG sleeve Carbon steel 1.0718; galvanized to min. 5 m
HIT-IC sleeve Carbon steel; galvanized to min. 5 m
HIT-SC sleeve PA/PP

726 10 / 2012
Hilti HIT-HY 70

Setting
Installation equipment
Anchor size M6 M8 M10 M12
Rotary hammer TE2 TE16
Other tools blow out pump, set of cleaning brushes, dispenser

Setting instruction in solid base materials

10 / 2012 727
Hilti HIT-HY 70

Setting details: hole depth h0 and effective anchorage depth in solid base materials

Setting details HIT-AC, HIT-V, HIT-V, HAS, HAS-E, HAS-R


Anchor size HIT-V HIT-V, HAS, HAS-E, HAS-R
M8 M10 M12 M8 M10 M12 M16
Nominal diameter of
d0 [mm] 10 12 14 10 12 14 18
drill bit
Effective anchorage
hef [mm] 80 80 80 80 90 110 125
depth
Hole depth h0 [mm] 85 85 85 85 95 115 130
Minimum base
hmin [mm] 115 115 115 110 120 140 170
material thickness
Diameter of clearance
df [mm] 9 12 14 9 12 14 18
hole in the fixture
a)
Minimum spacing smin [mm] 100 100 100 100 100 100 100
Minimum edge
a) cmin [mm] 100 100 100 100 100 100 100
distance
Torque moment Tinst [Nm] 5 8 10 5 8 10 10
Filling volume [ml] 4 5 7 4 6 10 15
a) In case of shear loads towards a free edge: cmin = 200 mm
A distance from the edge of a broken brick of cmin = 200 mm is recommended, e.g. around window or door frames.

HIT-IC HIS-N/RN

728 10 / 2012
Hilti HIT-HY 70

Setting details HIT-IC


Anchor size HIT-IC HIS-N/RN
M8 M10 M12 M8 M10 M12
Nominal diameter of
d0 [mm] 14 16 18 14 18 22
drill bit
Effective anchorage
hef [mm] 80 80 80 90 110 125
depth
Hole depth h0 [mm] 85 85 85 95 115 130
Minimum base
hmin [mm] 115 115 115 120 150 170
material thickness
Diameter of clearance
df [mm] 9 12 14 9 12 14
hole in the fixture
Length of bolt min. 8 min. 10 min 12
hS [mm] min. 10 max. 75
engagement max.20 max.25 max.30
a)
Minimum spacing smin [mm] 100 100 100 100 100 100
Minimum edge
a) cmin [mm] 100 100 100 100 100 100
distance
Torque moment Tinst [Nm] 5 8 10 5 8 10
Filling volume [ml] 6 6 6 6 10 16
a) In case of shear loads towards a free edge: cmin = 20 cm
A distance from the edge of a broken brick of cmin = 20 cm is recommended, e.g. around window or door frames.

10 / 2012 729
Hilti HIT-HY 70

Setting instruction in hollow base material using 330 ml foil pack

730 10 / 2012
Hilti HIT-HY 70

Setting details: hole depth h0 and effective anchorage depth in hollow base materials
HAS / HIT-V with HIT-SC

HIT-V, HAS

Setting details HIT-V / HAS with sieve sleeve


Anchor size M6 M8 M10 M12
Sieve sleeve HIT SC 12x50 12x85 16x50 16x85 16x50 16x85 18x50 18x85 22x50 22x85
Nominal diameter of
d0 [mm] 12 12 16 16 16 16 18 18 22 22
drill bit
Effective anchorage
hef [mm] 50 80 50 80 50 80 50 80 50 80
depth
Hole depth h0 [mm] 60 95 60 95 60 95 60 95 60 95
Minimum base
hmin [mm] 80 115 80 115 80 115 80 115 80 115
material thickness
Diameter of clearance
df [mm] 7 7 9 9 12 12 14 14 14 14
hole in the fixture
a)
Minimum spacing smin [mm] 100 100 100 100 100 100 100 100 100 100
Minimum edge
a) cmin [mm] 100 100 100 100 100 100 100 100 100 100
distance
Torque moment Tinst [Nm] 3 3 3 3 4 4 6 6 6 6
Filling volume [ml] 12 24 18 30 18 30 18 36 30 55

10 / 2012 731
Hilti HIT-HY 70

Setting details: hole depth h0 and effective anchorage depth in hollow base materials
HIT-IC with HIT-SC

HIT-IC

Setting details HIT-IC with sieve sleeve


HIT-IC
Anchor size
M8 M10 M12
Sieve sleeve HIT SC 16x85 18x85 22x85
Nominal diameter of
d0 [mm] 16 18 22
drill bit
Effective anchorage
hef [mm] 80 80 80
depth
Hole depth h0 [mm] 95 95 95
Minimum base
hmin [mm] 115 115 115
material thickness
Diameter of clearance
df [mm] 9 12 14
hole in the fixture
Length of bolt
hS [mm] min. 10 max. 75
engagement
a)
Minimum spacing smin [mm] 100 100 100
Minimum edge
a) cmin [mm] 100 100 100
distance
Torque moment Tinst [Nm] 3 4 6
Filling volume [ml] 30 36 45
a) In case of shear loads towards a free edge: cmin = 20 cm
A distance from the edge of a broken brick of cmin = 20 cm is recommended, e.g. around window or door frames.

732 10 / 2012

You might also like