15 ZUBADAN 5HP
-11oC Power INV 3HP
capacity (kW)
ZUBADAN 4HP
P
10 INV 5H
Heating
-25oC -20oC -15oC -7oC 0oC -25oC -20oC -15oC -10oC -5oC 0oC
Outdoor-air temperature at intake duct
Enhanced Comfort
The Flash Injection circuit improves start-up and recover from the defrosting operation. A newly introduced defrost operation control also improves
defrost frequency. These features enable the temperature to reach the set temperature more quickly, and contribute to maintaining it at the
desired setting.
Quick Start-up
Operation at +2C outdoor temperature Operation at -20C outdoor temperature
Discharged air
temperature reaches 50oC
ZUBADAN rises quickly, (in stable condition) ZUBADAN rises quickly,
45C in 10min Stable 45C in 20min
15 15
13kW with 45C indoor 13kW with 45C indoor
19min 20min 30min
air outlet temperature 10min air outlet temperature
capacity (kW)
10 10
45 oC in 19min 45 oC in 30min
Heating
Heating
0 0
0 5 10 15 20 0 10 20 30
Operation time (min) Operation time (min)
ZUBADAN Defrost Control and Faster Recovery from Defrost Operation Field Test Results: Office building in Asahikawa, Hokkaido, Japan
Operation data for 25 Jan. 2005 Operation data for 2 Dec. 2004
60 C 60 C Indoor outlet temp.
40 C 40 C
30 C 30 C
20 C 20 C Room temp. Installation
Room temp.
10 C example
10 C
Outdoor temp.
0 C
18:00 20:00 22:00 0:00 2:00 4:00 6:00 0 C
-10 C
Outdoor temp. -10C
-20 C 8:00 10:00 12:00 14:00 16:00 18:00 20:00 22:00
-30 C
ZUBADAN Defrost Control maintained a maximum interval
Reduced defrosting operation time
of 150 minutes between defrosting operations at outdoor
from 4 to 3 minutes.
temperatures of approximately -20C and 0C.
83
ErP Lot 10 Compliant with High Energy-efficiency Achieving SEER/SCOP
Rank A and A+
Powerful heating yet annaully high energy efficiency in both cooling and heating, achieving rank A and A+.
SEER SEER SEER
A A SCOP A SCOP
SCOP
A A+ A+
Minimum SEER 3.6 5.1 5.5 5.5 5.1
Minimum SCOP 3.4 3.7 4.0 4.0 3.5
A
Indoor Outdoor
Power Heat Interchanger (HIC)
HEX HEX
receiver
B
LEV B LEV A
LEV C
A Heat B
interchanger Injection Compressor
Refrigerant (HIC)
flow Flash Injection Circuit
The Mr. Slim model of the ZUBADAN Series is equipped with Mitsubishi Electrics Mollier Chart Image Representing Flash Injection
Circuit Operation
original Flash Injection Circuit, which is comprised of a bypass circuit and heat
interchanger (HIC). The HIC transforms rerouted liquid refrigerant into a gas-liquid
state to lower compression load. This process ensures excellent heating perfor-
mance even when the outdoor temperature drops very low.
LEV B
In traditional units, when the outdoor temperature is low, the volume of refrigerant
circulating in the compressor decreases due to the drop in refrigerant pressure LEV A LEV C
and protection from overheating due to high compression, thereby reducing heat-
ing capacity. The Flash Injection Circuit injects refrigerant to maintain the refriger-
ant circulation volume and compressor operation load, thereby maintaining heating
capacity.
84
PEDZ-SHW JA SERIES Please fill out the requested information
Please fill out the requested information
PUHZ-SHW80/112VHA *optional
PEAD-RP71/100/125JA(L)Q PUHZ-SHW112/140YHA
*optional *optional
100/125
JAQ
Optional