You are on page 1of 2

Networked Access Controller

Rosslares VeritraxTM Networked Access Control System: 255 panels (510 Doors)
Control. System of networked HW Controllers & Client/Server Enterprise PC Software.

GENERAL SYSTEM DESCRIPTION LED Indicators


Ideal for System Inspection
and Test
Rosslares VeritraxTM, is a networked access control system for medium
scale applications handling up to 10,000 right holding users, and 510 Locking
doors. A system may be comprised of up to 255 networked AC-215 Door with
Two Keys
Access Control Units (ACUs) driven by Rosslares powerful, flexible and Ventilated
easy to use PC Enterprise software. Side Panel

The VeritraxTM system provides the flexibility of connecting multiple door


Space for
networks across several communications platforms including RS-485, Labelling
Ethernet TCP/IP LAN, and PSTN Modem. (Zone and
SECURE Door Name)
Each VeritraxTM ACU subnets, consisting of 1 or more ACUs, may be Hinged Door
connected to a PC running the VeritraxTM AS-215 Server PC Software for for higher
anti-vandal
continuous event monitoring, or periodically for batch downloading of resistance
event data, administration and maintenance. Other PCs on the network
may connect to the server by running the VeritraxTM AS-215 Client PC
Software. The system provides an ideal, modular, expandable, and
flexible solution for commercial and institutional needs. Figure 1: AC-215 Enclosure Hardware
TM
Veritrax system runs on Microsoft Windows 98/Me and NT/2000/XP
operating systems. It is ideal for an enterprise scale application PS-14 Regulated AC/DC Tamper
deployment, utilizing a Client/Server architecture, allows access to Power Supply with Backup Switch for
Battery Charger Housing
multiple local or remote door networks, from multiple PC terminals within Closure
a local network.

AC-215 NETWORKED DOOR CONTROLLER


The VeritraxTM AC-215 ACU is a total solution for the creation of a Speaker / Bell
network of door controllers. Whatever configuration your application Unit for Alarms
requires, VeritraxTM lets you easily design and install a system optimized
to suit your needs. Each ACU automatically supports both 1 door (In/Out) Wire Strain
Releif
and 2 Door (In/Out, In/In and Out/Out) configurations (See Figure 3). This
provides maximum flexibility for securing your growing enterprise.
Mounted
AC215-
The complete hardware unit (See Figure 2) is housed in a rugged, hinged Main PCB
metal enclosure that is lockable and tamper protected. The enclosure is
compatible with Rosslares PS-14 Power Supply/Charger module, and
Wiring
provides externally visible status LEDs for Power, backup battery voltage Opeining
status, and power failure. Also included is a special sound unit for audible
signals such as alarms, doors reminders and a doorbell.
Inside the ACU enclosure, pre-installed components include an AC-AC
power transformer, a power supply/charger unit with tabbed battery Sealed
AC to AC
Lead-Acid Type
connectors, a special Bell Unit for audible signals such as alarms, door Transformer
Rechargeable
reminders, and doorbell, the main ACU PCB, space for a Sealed Lead Battery
Acid backup battery, and a tamper switch. Figure 2: AC-215 Hardware Platform
This means that installation only requires the connection of peripheral Single Door Single Door Two Door
keypads/card readers, door strikes/monitors, AC power, and optionally, to 1 Reader 2 Readers 2 Readers
a data network.
Overall the unit is self contained and ready for installation without the
need to source and assemble numerous system parts. This allows you to
concentrate your valuable time on designing and installing the system.

GLUE-LESS DOOR LOGIC IN NETWORK

The VeritraxTM AC-215 ACU provides seamless integration with


Rosslare's range of Proximity Card Readers, PIN keypads, Prox+PIN IN IN OUT IN IN
READER READER READER READER READER
readers, Smart Card Readers, RFID User Cards and tags.
The AC-215 is also compatible with Biometric and Fingerprint readers,
Facial and Voice recognition units, and all standard Wiegand 26 or Clock
and Data devices. Figure 3: AC-215 Configurations
Copyright Rosslare Enterprises Ltd 1999-2004
Networked Access Controller Unit
GENERAL DATA :
ID- 8Way Connector
Type of Unit: Medium Scale Networked Access Controller DIP Switch for Bell Unit
Product Availability: Available Speaker (Bell)
No. of Networks: 1 to 8
Out 2 COM. Out 1 COM.
No. of Panels Per Network: 1 to 32 Input 2 Input 1
Out 2 N.O Out 1 N.O
Output 2 Out 1 N.C Output 1
No. of Doors Per Network: 1 to 64 Out 2 N.C
In 2 <-> In 1 < - >
No. of Readers/Keypads per ACU: (One Door In/OUT or 2 Door In/In) In 1 <+>
In 2 <+>
Supported Door Logic: Programmable per reader as IN or Out or None
Access Rights User Capacity: 5000 or 10,000 (w/ MD-16 Memory Upgrade*)
Non Access Rights User Capacity: 20,000 or 40,000 (w/ MD-16 Memory Upgrade*)
Off Line ACU History Event Memory: 5000 or 10,000 (w/ MD-16 Memory Upgrade*) Access Control Access Control
Rdr. 2 +12Vdc Rdr. 1 Tamper
Reader 2 Reader 1
Event Memory Retention Power Loss: All System and User settings and Data Rdr. 2 - GND Rdr.1 LED
Non Volatile Local Memory each ACU D0 D1
D1 D0
# Access Levels: 128 Rdr.2 LED Rdr. 1 - GND
# Time Zones (Groups): 32 Rdr. 2 Tamper Rdr. 1 +12Vdc

# Holiday Dates: 64
Compatible Reader Protocols: Clock & Data, or Wiegand 26 Bits
Anti-Passback (Hard/Soft) YES Out 2A COM. Out 1A COM.
Input 2A Out 2A N.O Out 1A N.O
Input 1A
Real Anti-Passback: Valid for Two Readers on one ACU Output 2A Out 2A N.C Out 1A N.C Output 1A
Timed Anti-Passback: Valid on Each Reader (0 to 250 min) In 2A < - > In 1A < - >
In 2A <+> In 1A <+>
Global Anti-Passback: YES, Valid on all panels on all networks.
Programmable Auto Relock: YES, Based on Door Monitor or Timer
Extended Door Unlock Time: YES, Based on User Definition (Handicapped..)
Man Trap: YES, Based on Door Monitor to Enable Reader
First Person Delay: YES, on Automatic Door Unlock
RS485-
Output Activation: Timed, Toggled, or Input Follower RS232- Communications
INPUT
System Alarms: System registers various alarms. Communications Direct Wiring
POWER
Direct Wiring
Multiple Facility Codes: 4-max
Inputs: 4 Inputs - Single Door Configuration: Figure 4. AC-215 Main Controller Board
1) REX, 2) Monitor, 3) Tamper, 4) General Aux
4 Inputs - Two Door Configuration:
1) REX1 2) Monitor1 3) REX2 4) Monitor2 ELECTRICAL DATA:
Relay Outputs: 4 Outputs - Single Door Configuration: ACU Power Supply Voltage: 12V DC Regulated
1) Lock, 2) Alarm, 3) Aux 4) General Aux - From OEM Power Supply PS-14
4 Outputs - Two Door Configuration: ACU Power Supply Max Current: 500 mA input Current Limited
1) Lock1, 2) Alarm1, 3) Lock2 4) Alarm2 - From OEM Power Supply PS-14
ACU Maximum Input Current: Standby Load: 125 mA @ 12V DC
COMMUNICATIONS DATA: Max Load: 325 mA @ 12V DC

ACU Communications Method: RS-232 / RS-485 Half Duplex Max Current for PROX Readers: 150 mA@ 12V DC for Each Prox Reader

ACU Communications Data Rate: 57,600 Bits Per Second Max Current for Mag Stripe Readers: 150 mA@ 12V DC for Each Prox Reader

Dial-Up Remote Modem Support: YES, Supports Remote Modem Subnet (OEM MD-N33) Max Current for Keypad: 150 mA@ 12V DC for Each Keypad

TCP/IP Remote LAN Support: YES, Supports Remote TCP/IP Subnet (OEM MD-N32) Supports Heated Readers: YES, 12 V DC @150 mA

Remote Firmware Upgrade Support: YES, ACU Firmware may be changed by PC: 64 K with Maximum Current for Lock Strike: ACU Relay Supports up to 30V 5A
Bootstrap Loader and FLASH memory architecture.
RS-485 Network Bus Distance (Max): 1200 m Belden Shielded Pairs ELECTRICAL DATA POWER PCB << PS-14 >>:
Requires a Class 2 Transformer: Transformer Input 220 / 110 VAC
50/60 Hz to 16 Volt AC Output
INDICATIONS & MMI DATA:
Unregulated AC Input Power: 16 Volt AC (From Transformer)
ACU LED Visual Indicators: 8 - LEDs
Regulated DC Power Output: 12 Volt DC with 500 mA current Limit.
1) Data Rx
Backup Rechargeable Power: Yes, Supports 12V Lead Acid (SLA-Type)
2) Data Tx
Rechargeable Cell with on-board Charger
3) Relay Output 1
4) Relay Output 2 (PS-14 ) Auxiliary Power Output: PS-14 has 12V/2A for door strike and/or
5) Relay Output 1A Auxiliary output
6) Relay Output 2A Low Battery Status Monitoring: By Open Collector Output
7) Reader 1 Mode
8) Reader 2 Mode AC Power Loss Monitoring: By Open Collector Output

(MD-14) PS LED Visual Indicators: 3 - LEDs


PHYSICAL DATA:
1) Input Power
2) Low Battery ACU Board Dimensions [mm] 102 mmh x 116 mmw x 30 mmd
3) Power Failure Recommended Enclosure(mm)Space 200 * 170mm 11 in h 12 in x 3.5 in d
Audible Speaker Connection: Yes, Tones ( Siren, Bell and Chime Reminder) Weight [kg] 190g
Internal Sound and Tone Generator: Siren Prog.. to Activate on Alarm Events 2.4 KG w/Enclosure
Bell Prog.. to Activate on Selected Input 1 Kg PCB 2 Kg + Enc
Chime Prog.. to Activate on Access Events
Door Monitor and Ajar Warning Installation Indoor Installation Only.
8-WAY DIP Switch: For ACU Addressing, Type and Baud Rate
INTERNATIONAL STANDARDS:
2-Way Switch: For Setting RS-485 or RS-232
Hardware Supervised Readers: Reader Tamper Input and Reader LED control Standards Approvals UL 294 / FCC/
Reader Cut Detection Alarms. CE CENELEC

Supervised Lock: YES, By Chime, Timer Monitor

Copyright Rosslare Enterprises Ltd 1999-2004