FIELDSERVICE BULLETIN S) D+D1s122,006 Adjustment Procedure 1, Switch off the digitizer. 2. Remove the right side panel. 3. Unplug bus connection and power connection of the IP-transport unit. 4. Open four quick-action closures and remove the IP- transport unit. Keep the IP-transport unit in a safe place. 5. Put the cassette lift (1) carefully out of the way. Swivel it behind the metal plate. 6. Insert a small size cassette (1). 7. Move it firmly to the right limitation of the cassette holder (2). Now it is inevitable to move the left clamping mechanism (A) of the cassette towards the cassette until it touches it. Never proceed to the next step before the clamping mechanism has been moved towards the cassette! Section 13/2 Type 5155 Field Service Bulletin 11 ‘S) FIELDSERVICE BULLETIN DD+DIS122.00E 8. Lower the cassette holder (A) by turning the red wheel (1). 9. Lower it until the upper edge of the IP Alignment (B) approximately reaches the level of the upper edge of the guide plate (C). 10. Duting the adjustment process the cassette has to be pressed constantly with one hand towards the right limitation of the cassette holder (1). Field Service Bulletin 11 Type 5155 ‘Section 13/3 FIELDSERVICE BULLETIN S) D+D1s122,006 Check the position of the shank of the cassette opener (A) with the cassette pressed towards the right limitation of the cassette holder. Ifit either pushes tightly to the cassette or leaves some space between cassette opener and cassette, the position of the cassette opener has to be adjusted. In the perfect position, the shank of the cassette opener (A) softly touches the cassette. 111. Bring it to the perfect position by screwing the adjustment screw (1) either clockwise or counterclockwise. 12. Turn the red wheel (Figure 3 (1)) up and down several times, to check the function and the adjustment of the cassette opener. The result is satisfactory, if the cassette holder won't loose the cassette lid 13. If safety laquer at hand: add some safety laquer to the adjustment screw. 14. Close the ADC Solo again and switch on the digitizer. [@8~ Remember: This adjustment is only necessary with digitizers of the series 1102 ~ 1215. Section 1374 Type 5155 Field Service Bulletin 11 Meoicat Imacine Fieldservice CSO sence Bulletin Order-No.: DD+DIS247.99E October 99 ADC 70 1 Peco QFIH7 MA Type 5140 ADC Compact Type 5145 ADC Solo Type 5155 This document replaces DD+DIS125.99E and DD+DIS230.99E Please file this document in section 13 of your technical documentation. Year 2000 Readiness of ADC — Systems General ‘To make ADC systems year 2000 ready, 2 CD-ROMs containing the required updates, have been created. Together with the installation instructions and additional information they can be ordered under: EB+4406.2000 OSC This package is also included in the software upgrade for ADC70 (Order number: EB+ 4406.0666). The following chapters show how to make the different ADC Systems year 2000 ready. ADC 70 System: ‘Software Modules: The following software versions are year 2000 ready. All other ADC 70 System software ‘components are not tested for year 2000 readiness and therefore have to be replaced by the modules mentioned below to achieve year 2000 readiness. * ADG 70 Digitizer: CHM 2 ADH.A.1.4.10 VME > ADCA2.1.10 * ADG 70 Processing Station PS5000 MIMOSA SW > PS5.A.0,7.08 Operating system 2 SunOS 5.5 (SUNA0400), Solaris 2.5 Operating system updates year 2000 updates for Solaris 2.5" * For the installation procedure see appendix 1 of this documentation. printed in Germany AGFA FIELDSERVICE-BULLETIN D+DIS247.99E Note 1 Note 2: Note 3: 22 * ADC 70 1D-Station Id-Station SW 2 AID.A1.1.07 Operating System Dos The date on the ADC 70 ID-Station has to be changed manually on the 01-01-2000 because DOS jumps to the date 01-01-1970. Please change the date on the ID-Station in the following way: * Go to the Service Menu of the ADC 70 ID-Station application. * Select “date and time”. «Enter the correct date in the following manner: 01-01-2000 (the year “2000” has to be entered in four digits). + Leave the ADC 70 ID-Station software and go to “DOS"-level. + Enter the command date. + Enter date in the following manner: 01-01-2000 (the year “2000” has to be entered in four digits, otherwise DOS jumps to 01-01-1970). «Reboot the ID-Station. As you probably will not be on site the 1" of January 2000 please advice the customer to do solill The ADC 70 ID-Station software versions currently released have never been released to run under any MS-Windows environment. Therefore they never have been tested for year 2000 readiness in that environment. Consequently AGFA cannot guarantee that the ID-Station- ‘SW runs properly in that environment and is able to manage the leap to year 2000. It date and time on the Processing Station are changed and the Station is rebooted afterwards, it comes up with time zone set to “PST” (Pacific Standard Time). This is @ general bug in Solaris 2.5 together with SUN Sparc20 hardware and has nothing to do with non-compliance to year 2000. The Processing Station has to be rebooted a second time. Then the correct time and time zone are set. Availability Al the software components mentioned above (including the year 2000 updates) will be available in one package from October 1999 on. They can be ordered with spare part number: ———Ee EB+4406.0666 ADC Compact System Software Modules The following software-versions are year 2000 ready. All other ADC Compact System software components are not tested for year 2000 readiness and therefore have to be replaced by the modules mentioned below. * ADC Compact Digitizer Digitizer SW > COP_1215/ COPA1215 + ADC Compact Processing Station software a) MIMOSA SW DIPS1003 Operating system = SunOS 5.5 (SUNA0403), Solaris 2.5 Operating system updates year 2000 updates for Solaris 2.5" * For the installation procedure see appendix 1 of this documentation. Section 13/2 Types 5140, 5145, 5155 15.10.1999 DD+DIS247.99E FIELDSERVICE-BULLETIN b) MIMOSA SW > VIPS1005 Operating system = SunOS 5.6 (SUNA0506), Solaris 2.6 Operating system updates year 2000 patches for Solaris2.6* * For the installation procedure see appendix 2 of this documentation. * ADC Compact Preview & ID-Station Prid-Station SW = PRID 1.1.02 Operating System Windows 95 + year 2000 updates for Win95 + Internet Expl.5* Windows NT4.0 + year 2000 update for WinNT4.0 with Service Pack 5 ** * For the installation procedure see appendix 3 of this documentation. ** For the installation procedure see appendix 4 of this documentation. 3.2 Availability The ADC Compact Digitizer has to be upgraded to COP_1215 / COPA1215 or higher to be year 2000 ready. The Digitizer software is available on AGFA Digimail and from the spare parts stock under the following spare part numbers: COP_1215/COPA1215: CM+9.5145.1050.2 The ADG Compact Processing Station and the ADC Compact Preview & |D-Station have never been released and delivered with an application software lower than DIPS.1.0.03 and PRID 1.1.02, respectively. To make the Processing Station ready for year 2000 the Solaris updates have to be installed, to make PRID ready for year 2000 the Win95 or WinNT updates have to be installed. These updates are available from October 1999 on. The order number is: EB+4406.2000 ADC Solo System 4.1 Software Modules The following Software-Versions are year 2000 ready. All other ADC Solo System software ‘components are not tested for year 2000 compliance and therefore have to be replaced by the modules mentioned below. * ADC Solo Digitizer Digitizer SW 2 SOLB1008 * ADC Solo Processing Station software a) MIMOSA SW = DIPS1003 Operating system = SunOS 5.5 (SUNA0403), Solaris 2.5 Operating system updates year 2000 updates for Solaris 2.5" * For the installation procedure see appendix 1 of this documentation. 15.10.1999 Types 5140, 5145, 5155 Section 13/3 FIELDSERVICE-BULLETIN D+DIS247.99E b) MIMOSA SW > VIPS1005 Operating system = SunOS 5.6 (SUNA0506), Solaris 2.6 Operating system updates year 2000 updates for Solaris 2.6" * For the installation procedure see appendix 2 of this documentation. * ADC Solo Preview & ID-Station Prid-Station SW 2 PRID 1.1.02 Operating System Windows 95 + year 2000 updates for Win95 + Internet Expl.5* Windows NT4.0 + year 2000 update for WinNT4.0 with Service pack 5 + Internet Expl.5** * For the installation procedure see appendix 3 of this documentation. * For the installation procedure see appendix 4 of this documentation. 4.2 Availability The ADC Solo Digitizer has never been released and delivered with a software lower than SOLB1008. Therefore, the digitizer is year 2000 ready and needs no upgrade. The ADC Solo Processing Station and the ADC Solo Preview & ID-Station have never been released and delivered with a software lower than DIPS1003 and PRID1102 respectively. To make the Processing Station ready for year 2000 the Solaris updates have to be installed, to make PRID ready for year 2000 the Win95 or WinNT updates have to be installed. These updates are available from October 1999 on. . The order number is: EB+4406.2000 | Section 13/4 Types 5140, 5145, 5155 15.10.1999 DD+D18247.99E Appendix 1 Appendix 1 Year 2000 Patches for the Operating System Solaris 2.5 (MIMOSA version PS5.A.0.7.06 or DIPS 1003) General Information Solaris2.5 is used as operating system for the PS5000 (Version PS5.A.0.7.06) and DIPS1003 ‘software. Please apply this update only for Solaris2.5! The Solaris updates are language independent and only contained on CD 2. The folder Solaris 2.5 on the y2K CD-ROM contains: 1)_install-bet Here you can find installation information on the Solaris 2.5 patches 2) Solaris2.5-y2k-patch.tar This is the compressed patch file for Solaris 2.5 The Solaris updates for y2k included on the CD are based on the results of the SUN test tool "SUN SCAN 2000 - version 2.2". Proparations Stop all currently running applications * select Maintenance in the Controller Menu + PS5000: select 2 -> select 8 > select 2 DIPS1003: leave the Maintenance Menu with ctrl. + ¢ Installation * move mousepointer to the grey background and press right mousebutton start a terminal window by selecting Program -> Terminal a terminal window pops up insert the CD-ROM into the CD-ROM drive move mousepointer to the window and enter the following commands enter cir entercat version enter showrev -p enter volcheck enter cd /edrom/cdron0/y2kSUNSolaris/Solaris2.5 enter cp Solaris2.5-y2k-patch.tar.gz /tmp/. enter cd /tmp enter gunzip Solaris2.5-y2k-patch.tar.gz enter tar -xvf Solaris2.5-y2k-patch.tar enter su enter adcroot enter . /doit if the CD-ROM file manager has opened automatically, close it eject CD-ROM reboot the workstation end of installation page 1 DD+D18247.99E Appendix 2 Appendix 2 Year 2000 Patches for the Operating System Solaris 2.6 (MIMOSA versions > VIPS 1005) General Information Solaris2.6 is used as operating system for software > VIPS1005. Please apply this update only for Solaris2.6! The Solaris updates are language independent and only contained on CD 2. The folder Solaris 2.6 on the y2K CD-ROM contains: 1) install-bet Here you can find installation information on the Solaris 2.6 patches 2) Solaris2.6-y2k-patch.tar This is the compressed patch file for Solaris 2.6 The Solaris updates for y2k included on the CD are based on the results of the SUN test tool "SUN SCAN 2000 - version 2.2". Preparations Stop all currently running applications * select Maintenance in the Controller Menu + select 3-> select 9-> select 2 leave the Maintenance Menu with ctrl. +¢ Installation move mousepointer to the grey background and press right mousebution start a terminal window by selecting Program -> Terminal a terminal window pops up insert the CD-ROM into the CD-ROM drive move mousepointer to the window and enter the following commands enter cir enter cat version enter showrev -p enter volcheck enter. cd /cdrom/cdrom0 /y2kSUNSolaris/Solaris?.6 enter cp Solaris2.6-y2k-patch.tar.gz /tmp/. enter cd /tmp enter gunzip Solaris2.6-y2k-patch.tar.gz enter tar -xvf Solaris2.6-y2k-patch.tar enter su enter adcroot enter . /doit if the CD-ROM file manager has opened automatically, close it eject CD-ROM reboot the workstation end of installation page 2 DD+D18247.99E Appendix 3 Appendix 3 Year 2000 Patches for the Operating System Windows 95 General Information 1. CommonWin98 folder In this map you can find 2 executables which upgrade a Win95 system. Both files are language independent. W95setup.exe will install Windows 95 Service Pack 1 Update. This is only necessary when you have Win9Sa installed on your system (check in: Start>Settings>Control Panel>System>System Properties/General). y2kvdhep.exe will update MS DUN 1.3 or WinSock 2.0 version of VDHGP.386. This utlity will check if you have one of the 2 components installed and then will update them. If you did not install these Windows components in the past, you will get the following message: (setup cannot update the Ms DUMI.3 or Winsock?.0 version of VDHCP.386. If you install either of these updates in the future, you vill need to re-install this update). These components are not required for normal operation of the PRID-Station. However, if you want to install these components in the future, you'l have to install the update with y2kvdhcp.exe as well. 2.1 1ES subfolder In this map you will find ieSsetup.exe which allows you to install Internet Explorer 5.0 This version is needed to be Y2K compliant concerning your WEB browser. 2.2 Win95 folder In this folder you will find w95y2k.exe which allows you to perform your language specific Winds updates to be Y2K compliant. Preparations Stop all currently running applications Installation ‘step a) Installation of Windows 95 Service Pack 1 Update Note: this step is only necessary if Win95a is installed on your system (otherwise skip step a and continue with step b): insert CD-ROM in CD-ROM drive open the Win85 Explorer and select the CD-ROM drive select folder CommonWin9s double-click on W95setup.exe This will install Windows 95 Service Pack 1 Update. Do you wish to cont inue? click on yes. agree to the licence agreements, click on yes * copying files * Installation of Windows 95 Service Pack 1 Update completed successfully. * Continue with step b. page 3 Appendix 3 p+Di8247.99 step b) Update MS DUN 1.9 of WinSock 2.0 version of VDHCP.386 insert CD-ROM in CD-ROM drive open the Wings Explorer and select the CD-ROM drive select folder CommonWingS double-click on y2kvdhep.exe Note: if you get the message (setup cannot update the MS DUNI.3 or Winsock2.0 version of VDHCP.386. If you install either of these updates in the future, you will need to re-install this update) olick OK. and continue with step c. ‘+ agree to the licence agreements, click on yes + copying files + end of installation step b; continue with step c. ‘step c) Installation of update year 2000 support for Windows 95, make sure that the CD-ROM is stil in the CD-ROM drive open the Wing Explorer and select the CD-ROM drive select your language select Win95 double-click on w9Sy2k.oxe agree to the licence agreements, click on yes copying files you are requested to reboot your computer, click on yes the computer reboots logon as usual end of installation year 2000 support for Windows 95; continue with step d. step d) Installation of Internet Explorer 5 make sure the y2k CD-ROM is still in your CD-ROM drive select the CD-ROM drive in the Win95 Explorer select your language select IE5 double-click on TESsetup.exe agree to the licence agreements, click on next the window Windows Update: Internet Explorer and Internet tools appears select Install now - typical set of components, click on next copying files you are requested to reboot your computer, click on finish the computer reboots logon as usual the window jindows Update appears; just wait unti the installation of the components is finished. ‘+ end of installation Internet Explorer 5; end of installation year 2000 updates for PRID-Station. page 4 DD+D18247.99E Appendix 4 Appendix 4 Year 2000 Patches for the Operating System Windows NT 4.0 General Information The WinNT folder contains sp5i386.exe which is the WinNT 4.0 upgrade to service pack 5. Running the SP5 module is required each time you install new hardware. Proparations Stop all currently running applications Installation a) Installation of Service Pack 5 insert CD-ROM in CD-ROM drive open the WinNT Explorer and select the CD-ROM drive select your language ‘select WinNT double-click on sP5i386.exe agree to the licence agreements, deselect the second box (choice of returning to SP3), click on next copying files you are requested to reboot your computer, click on finish the computer reboots logon as usual end of installation Service Pack 5 b) Installation of Internet Explorer 5 make sure the y2k CD-ROM is still in your CD-ROM drive select the CD-ROM drive in the WinNT Explorer select your language select IES double-click on TESsetup.exe agree to the licence agreements, click on next the window Windows Update: Internet Explorer and Internet tools appears select Install now - typical set of components , click on next copying files you are requested to reboot your computer, click on finish the computer reboots logon as usual the window Windows Update appears; just wait until the installation of the components is finished. * end of installation Internet Explorer, end of installation year 2000 updates for PRID-Station page 5 DD+D18247.99E Appendix 5 Appendix 5 Layout of the CD's. This set of 2 CD's contains all necessary files to upgrade a PC with Win95, Win/NT and Sun's workstation equiped with Solaris 2.5 and 2.6 Note: The Solaris updates are language independent and only contained on CD 2. Directory structure of the CD's = cpt lo S 8 7 Commonvings TE Commoriwings EG Engand © @ Denmark 15 2 wnss @ Went 5G Fiance gis wns QB Wient SG Germany ies Wins WirhT 2B hay Bis Bwns WinNT © Fotugel @ Went EG Span EG p2kSUNSolatis is a Solais2 5 B Wes BD Solein2.6 @ Went page 6 Mepica Imacine Fieldservice CSO sper Bulletin Order-No.: DD+DIS263.99E November 1999 Lm AA ADC SOLO 1 eco vty Hat Type 5155 Please file this document in section 13 of your technical documentation ADC Solo Software Version Sol_1108 + Patch SOLB1108 available now Cassificato When? 1 General ee es ee ee x | «x x 1.1 Order Number: SOL_1108 + Patch SOLB1108 CM+9.5155.1050.1 1.2 Scope of Delivery * SOL_1108 4 floppy disks (1 x harddisk formatter floppy* (boot floppy), 3 x application program floppies) + SOLB1108 1 floppy disk * 1 empty floppy disk * 1 upgrade instructions (DD+DIS262.99E) * 1 instructions for the adjustment of the side wall / cassette unit (DD+DIS197.99E) * Due to wrong usage, from now on the boot floppy is named "harddisk formatter floppy". pate 1.3 Year 2000 Readiness SOL_1108 and Patch SOLB1108 are completely year 2000 ready. 2 What is new in SOL_1108 and Patch SOLB1108 24 Technical Specification * perceptible improvements concerning througput are implemented. + the temperature in the VME-Rack is measured every 10 minutes. If 45°C is exceeded, the warning 20844 is put to the info counter. 20644 is counted once every transition from below 45°C. If 55°C is exceeded, the service error 20645 is displayed and the machine is locked. 20645 is removed, when the temperature drops below 55°C. + startupfinitialisation procedure: if required and possible, cassettes and IPs, which are in the digitizer during start-up are scanned, and the cassette is automatically ejected. * erasure time is now dependent on the voltage selector. printed in Germany AGFA FIELDSERVICE-BULLETIN S * the new erasure-Ctrl board F.8.5155.6420.2 is now supported in addition to the old one F.8.51556430.0. Check of temperature sensor on erasure-Cirl board F.8.5155.6420.2 is done after the initialisation procedure is finished. ‘+ before start of scanning the alignment finger is moved some steps away from IP. the release contains the ‘old’ network components: NET.PRG and DCM.PRG. + Patch SOLB1108: enclosing CAM.PRG: reducing the belt drive speed during ejection of a cassette. enclosing ALN.PRG: reducing the likelihood of an IP-Jam during the alignment of the cassette unit * remote service is implemented now (HTTP). Access via LAN or Service Host (modem) Prerequisites: Netscape Web-Browser D+D18263.996 2.2. User Interface ‘* jams: pictograph is now displayed. * checks/check IOBUS tests of all IOBUS nodes are implemented. ‘+ diagnostics of Erasure-Ctrl board is now implemented 3 Important Remarks «© to.avoid any formatting, the ‘format’ program is delivered no more. ‘format’ would cause a complete loss of the test images. Section 13/2 ‘ADC SOLO 15.11.1999 Mepica Imacine Fieldservice CSO sper Bulletin Order-No.: DD+DIS269.99E November 1999 34 TL ADC System 1 Pstaoeuinat Types 5145, 5155 Please file this document in se n 13 of your technical document: Workaround for “No Auto-Detection of Cassettes” Problem Cassette auto-detection does not work any more after Service Pack 5 has been installed on the PRID station. This happens only if the PC has a Pentium Ill processor inside. Reason The current Java runtime version (classes.jar) has problems when run together with Service Pack 5 and Pentium Ill processors. Workaround ‘There are two Workarounds responding to that problem. Perform only one of the following actions: 3.1. Copying the file “classes jar” 3.2 Change the Target line in the Properties Window Copying the file “classes.jar” Note: The file classes jar can be downloaded from the mailbox. Copy the file “classes jar” to the directory “c:\prid”: Restart the program. printed in Germany AGFA FIELDSERVICE-BULLETIN D+D18269.996 3.2 Change the Targe (On your desktop, you can find the PRID icon (see arrow). + Glick the right mouse button once to open a pop-up menu. * click on properties (see arrow). Create Shotxk Delete Renae Section 13/2 ‘ADC System 23.11.1999 DD+DIS269.99E Gus) FIELDSERVICE-BULLETIN The “prid Properties” - window opens. iar Gove Shou | pan Fone Pid i Target ype: Aplication Tergetlocation: bin Faget [bnivew 228 at, loom a pi e Stat in Shortt key: lun Normal wirdow The Target — line shows the following command: C:\prid\javalbin\jrew.exe -mx40m -cp .\classes.jar;.\dicom jar prid The command “jrew.exe” is responsible for the “no auto-detection of the cassette” problem. ‘+ the way to avoid this problem is just to remove the “w” in this “jrew.exe” -command (remove “w” and click “apply”) The Run — line shows “Normal window”. If you want to change this, you may use “maximised” as setting Do never use “minimised”, because the auto-detection of the cassettes won't work then. 23.11.1999 ADC System Section 1373 FIELDSERVICE-BULLETIN D+D18269.996 After the adjustment, the start-up command in the Target-line should look as follows: C:\prid\javalbin\jre.exe -mx40m -cp .\classes jar;.\dicom.jar prid fo Tape: inWeene mxtOrn-cp classes iar: \deom ar pid Winner With this setting the system should work properly. The only disadvantage is that, whenever the PRID application is started, a DOS-window appears on the screen as well. This DOS-window remains on the screen, but the Preview- and the ID-window are in the foreground. So, the Customer usually has no idea that the DOS- window is there. Only if both windows (Preview and ID) are minimised, the DOS-window can be seen. As soon as PRID is closed, the DOS-window disappears from the screen. 4 Solution The problem will be solved in the next release of PRID software. Section 13/4 ‘ADC System 23.11.1999 Mepicat Imacine Fieldservice CSO Srervione Bulletin Order i November 1999 IN ADC Compact 1 Pieoo QG48G MAI Type 5145 ADC Solo Type 5155 Please file this document in section 13 of your Technical Documentation Jumper Configuration of (GS310) VME-Harddisk ADCC/ADCS Before installing a new harddisk CM+7.0486.1260.0 after a harddisk crash, check if the jumper configuration of the new HDD iis correct. Due to production reasons the jumper configuration of the harddisks may vary. ‘The correct jumper configuration is shown in the figure below. correct jumper configuration printed in Germany AGFA Mepica Imacine Fieldservice CSO Srervione Bulletin Order-No.: DD+DIS283.99E Dec. 1999 mL ADC Compact 1 Peco HEME MAt Type 5145 ADC Solo Type 5155 Please file this document in section 13 of your technical documentation Lubricated ball bearing introduced for Galvo in ADCC / ADC Solo Problem: Early wear of the galvo. Reason: Unsufficient lubrication of the ball bearing of the galvo. Solution: Installation of a modified galvo with a lubricated ball bearing CM+9.5145.2040.1 (including installation instructions for ADC Compact and ADC Solo). Itis recommended to remove the galvo only, ifthe limiting values of the galvo monitoring in the infocounter are exceeded as shown in the example below. offset: 230 amplitude counts: >60 4.7 Galvanometer Monitoring Maximum peak-to-peak offset counts: 30, amplitude counts: 60 Date Time cycles Offset Amplitude 12-Sept-1999 11:29:15 3 37 62 After the removal of the galvo, you have to adjust the laserbeam as described in the installation instructions. [G@GS™ tis possible that the adjustment screws of the galvo are defective, so it is advisable to hold a galvomount CM+9.5145.2910.2 on stock. printed in Germany AGFA FIELDSERVICE-BULLETIN D+018283.996 After the adjustment procedure you have to calibrate all formats. 5, _ See section 12 of your technical documentation ADC Compact or ADC Solo. ADC Compact: ES To avoid calibration problems with format 35X34 cm HR, it is compulsory to load COPA1215 Defect Label Fil in the form and send it together with the defect galvo to: AGFA Munich Retourenstelle Tegemseer Landstr. 161 81536 Munich for the attention of Mr. Hopfinger Section 13/2 5145/5155 01.12.1999 Mepicat Imacinc Fieldservice CSO™ Smee Bulletin Order-No.: DD+DIS050.00E February 2000 A |_| ADC Solo tran 0 Type 5155 Introduction of the Modification Kit "Opener Spring" at the Side Wall of the Cassette Un The installation of the “opener spring" —_[Gassifeation When? must be carried out on all ADC Solo Se [rim Sn | [SS Ew digitizers: = x Problem The lid of the cassette cannot be opened. Although an IP is inside the cassette, the error message 22D40 is displayed: Meaning of 22D40: User Fault, Input of cassette without IP in Input buffer. The user is requested to remove the cassette and insert an IP. Reason The pawl of the swivel plate cannot take hold of the lid during the opening process. The lid remains closed. The IP transport unit moves up and the suction cups try unsuccessfully to suck on the lid, which causes the error message. Soll nm Installation of a return spring at the side wall of the cassette unit in order to draw back the pawl of the swivel plate to its home position. Order Numb Modification kit "opener spring” CM+9.5155.9210.0 Scope of Delivery ‘1x retum spring (greased leg spring) 1 x screw (hexagon head 5mm) 1x HW-modification floppy 1 x installation instructions Installation ex Works ‘The modification is installed ex works with the following machines: Serial Number: 1233, 1234, 1235, 1236, 1238, 1239, 1240, 1241, > 1243 printed in Germany AGFA Mepicat Imacinc Fieldservice CSO saeisneor Bulletin Order-No.: DD+DIS082.00E March 2000 a ADC Compact 1 Piece QL.CZ0 MAI Type 5145 ADC Solo Type 5155 Please file this document in section 13 of your technical documentation. New Language Floppy for ADC-Compact and ADC-Solo Version COPL1102 (Chassifcation 1 General A floppy disk containing a new version of language files (COPL1102) for the user interface is available now. After the installation the following languages are available: Danish, German, English, Spanish, Finnish, French, Italian, Dutch, Norwegian, Portuguese, ‘Swedish Order Number: Version COPL1102 -- CM#9.5145,0923.0 2 Hardware and Software Requirements. No special hardware requirements, ADC-Compact Software > COP_1111, ADG-Solo Software > SOL_1008 3 Installation Select Service Menu Install from floppy Language files. Follow the online instructions. 4 Known Bugs in COPL1102 + ADC-Compact displays the ADC-Solo menu of the keyoperator after the language is fixed. This problem is gone after a reset. «The "Destination not ready" message is not always centered properly. 5 Installation ex Works ‘The language files are installed ex works with the following software: type 5155: SN> 1245, 1246, 1253 - 1256, 1259, 1264, > 1268 printed in Germany ———— —— AGFA Meoicat Imacine Fieldservice CSO speuiseer" Bulletin Order-No.: DD+DIS205.99E October 99 1 Piece QFSKT MAI ADC System Type 5145, 5155 Please file this document in section 13 of your technical documentation ADC Compact/Solo. New PC-Hardware for PRID - Station Since September 1999, a new hardware configuration for the PRID — Station is delivered. The new configuration of the PRID - PC is as follows : * Type: COMPAQ DESKPRO EN SFF 6450+ + Processor : Pentiumill / 450/100 MHz - 512KB L2 Cache - 256MB RAM + HardDisk 10GB ULTRA ATA * CD-ROM IDE SLIMLINE CD-ROM 24x- * FloppyDrive 1.4MB + Video Embedded ATI RAGE PRO TURBO 2X AGP GRAPHICS with 4MB SGRAM (MAX 8MB) © Monitor : 7 + Network. Embedded 10/100 TX INTEL WOL 24 UTP PCI NIC * Audio Integrated ESS 1869 FULL DUPLX 16BIT AUDIO WITH INTERN. SPKR + Case Number of slots: 1 PCI / 1PCL-ISA / 3BAYS ‘+ Heat emission (Watts): -PC <100W = Monitor (Compaq 17"V75)* << 115W. - Monitor (Compaq 17" V700) ** < 130 W * phase-out model ** follow-up model to V75 printed in Germany Ed ————SSSSSSSS=_ AGFAS FIELDSERVICE-BULLETIN D+DIS205.99 Dimensions (WxHxD / cm): -PC 31.8 x 9.0.x 37.1 - Monitor (Compaq 17"V75)* 42.1 x 43.5 x 43.6 - Monitor (Compaq 17" V700)** 42.4 x 44.4 x 43.1 + Weight: (kg) -PC approx. 9.1 kg - Monitor (Compaq 17" V75)* 22.0 kg - Monitor (Compaq 17" V700) ** 18.5 kg * Software : COMPAQ RESTORE CD + WIN/NT 4.0 + MS Service Pack 5 * phase-out model ** follow-up model to V75 Section 1372. ‘ADC System 26.10.1999 MED Technical CSO. Documentation Order No.: DD+DIS217.98E ADC Solo Ss stem NK * 1 Piece Q7WGY Mat INSTALLATION PLANNING and Specifications 1st edition Hardware Version ADCS 99.02 ADC Solo Preview- / Processing Digitizer ID- Station Station Type 5155 / 100 Type 4406 / 821 Type LASP6 / 009 Base: VME Base: PC. Base: Ultra Sparc 10 The Installation Planning Instructions are separately available. Order No: DD+DIS217.98E printed in Germany AGFA} Caution: This system uses high voltage. Please observe the respective safety regulations. These instructions describe adjustments and routines which must only be performed by qualitfied technical personnel. Note: Electrical connections and repairs must only be made by authorised electricians. Mechanical connections and repairs must only be made by authorised technicians. CE Declaration: According to the medical regulations the CE Declaration (CE Conformity) becomes void if the product is changed without prior consent of the manufacturer! This applies to all parts and not only to the safety relevant parts! We reserve the right to change data and characteristics in the light of technical progress. DD+DISo98.99E Installation Planning Section 14 List of contents Part 1: Installation plannin System overview Machine dimensions / Access for repair and maintenance. ‘ADC Solo Digitizer os sn 1 Station. PRID. Proview Station (PC)... a Processing Station (Uitra Sparc 10). Hardcopy printer. Electrical connections of the system components Mains connection: Connection to an outiet Connection cable ADC Solo Digitizer. ID - Tablet... Transport path for ADC Solo Digitizer Transport path for other ADC Solo System Components. Ambient conditions of the System component ADC Solo Digi Part 2: Network planning ... Dedicated network for ADC Solo System. Integration into an existing / new network. Part 3: Specifications ... Delivery modalitie Minimum Hard- and Software requirements Type overview Scope of delivery . Connection cables of the individual system components. Electrical Data: Power consumption Leakage current toward earth connection Packing dimensions: Weights: Climatic data. Safety regulations Checklists for the responsible installation person. For Technical data of the commercially available devices as PCs and Workstations please refer to the corresponding user manuals! 14.06.1999 5155 / 100 Section 14/1 DD+DISo98.99E Installation Planning Part 1: Installation planning ‘System overview S18514CM.COR 14.06.1999 5155 / 100 Section 14/1

You might also like