Positive Material Identification

Test Report Sheet 1 of 1

Project : Report No. : PMI-625-01


Customer - Wilhelm Ref. Doc./ Rev. :
Part No. / Rev. : - Fmc Ref. Doc./ Rev. :
Ref. Dwg. No. & Rev. : - Surface Condition : as machined
Description : - Date Examined : 30-Sep-15
Customer P.O. No. : - Analyzer Type : Thermo Scientific Niton XL2 800 XRF Analyzer
Production Order : - Serial No. : 65153
Sales Order : - Reference CRM : Inconel 625
Work Order No. : - Serial No. : PMI-625-01

Position/ Elemental Composition, %


o.

Ref. Dwg. Joint/ Weld No. Alloy Name/ ID Disposition


N

Location
m

Cr Ni Mo Nb Fe Cu Ti
Ite

Refer to the downloaded data from the


1 - - Clad Surface Inconel 625 Accepted
PMI instrument attached on this report.

SERIAL NO.: PMI-625-01

LOT NO.: -

Remark/s:
1.Refer to the downloaded data from the PMI instrument attached on this report.

Examined by: Reviewed by: Approved by:

QC Inspector QA/QC Manager Customer Rep./ TPI


Name/ Sign/ Date Name/ Sign/ Date Name/ Sign/ Date
Rev. 0, 27 Feb 2012
Positive Material Identification F753-S1-01

Test Report Sheet 1 of 1

MTP COMPLEX COMPONENTS W/IN SUBSEA


ACTUATOR WELD OVERLAY CLADDING AND
Project : PWHT OF SUBSEA SCTUATOR PARTS FROM Report No. : PMI-141400163-321400459
FREE ISSUED AISI 8630 MATERIAL Ref. Doc./ Rev. : 753- W1 REV 1
Customer : JEP PRECISION ENGINEERING PTE LTD : --
Structure/ Part No. : PART NO.: JSC12-10081138 / HEAT NO.: N/A Surface Condition : as-cladded
Ref. Dwg. No. & Rev. : 10000739129 REV 01 Date Examined : 11-Dec-14
Description : BONNET 2-1/16'' ACTUATOR CLAD Analyzer Type : Thermo Scientific Niton XL2 800 XRF Analyzer
(FINAL P/N# 10080163) Serial No. : 65153
Customer P.O. No. : P000010160 Reference CRM : 1.25Cr-0.5Mo (UNS K11572)
Work Order No. : 321400459 Serial No. : 35J-10182010-IARM-P

Position/ Elemental Composition, %


o.

Ref. Dwg. Joint/ Weld No. Alloy Name/ ID Disposition


N

Location
m

Cr Ni Mo Nb Fe Cu Ti
Ite

10000739129 Refer to the downloaded data from the


1 REV 01
321400459 Clad Surface Inconel 625 Accepted
PMI instrument attached on this report.

S/N NO.: 4500547950-30-105

Remark/s:
1.Refer to the downloaded data from the PMI instrument attached on this report.

Examined by: Reviewed by: Approved by:

TEO MOHANRAJ
QC Inspector QA/QC Manager Customer Rep./ TPI
Name/ Sign/ Date Name/ Sign/ Date Name/ Sign/ Date
Rev. 0, 27 Feb 2012